HomeMy WebLinkAboutLot Certifications - 06/19/2016Date: June 14, 2016 Subdivision: Union Place
Address: 215 Urban Prairie Street
Fort Collins, CO
Lot: 8 Block: 1
Permit Application #: 61506984
Larimer County Parcel #: 97021-17-008
Larimer County Reception #: 20150029089-20090074634
(on development agreement)
I, (print) Kevin E. Forbes a Colorado registered professional engineer, verify that construction
of all stormwater facilities and grading is complete and hereby submit this certification.
Please answer the following questions by initialing the appropriate response. For each question initialed "No," attach an
explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots.
1.
Certification includes attached Stormwater-approved grading plan. (NOTE: City's
No
Yes
Building Department does not approve grading plans).
2.
Certification includes the attached as -built survey dated 6/10/2016 (must be within 60
No
Yes
days of the date the certification is submitted) accurately and truthfully depicting
elevations for:
• Top of foundation/finished floor
• Finished grade on each side of the structure
• Quarter points along each lot line (not more than 50 feet apart)
• Break points/high points
• Swales
• Berms
• Retaining walls
• Air conditioning pads
• Window wells
• Any other appurtenance(s) within an easement
3.
All elevations are within a 0.2 foot tolerance of the approved grading plan.
No
Yes
4.
The top of foundation is at least 6 inches above the highest grade surrounding the
No
Yes
structure.
S.
There is a minimum grade of 5% away from the structure within the first 5 to 10 feet
No
Yes �.
adjacent to the residence.
6.
All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single
No
Yes 4�U
family lots when the swale is draining the runoff from only two adjoining properties)
and are not steeper than 25% (4:1).
7.
All flow lines of stormwater drainage swales are a minimum of 6 inches below the
No
Yes
elevation of ground adjacent to the structure and will direct drainage as shown on the
Stormwater-approved grading plan.
8.
All downspout locations and discharge directions are shown on the as -built survey.
No
Yes
Runoff is directed into an appropriate drainage system or lot line Swale, and it is not
directed onto neighboring properties.
526/16
Page 1
9. A smooth transition (no grade break) is provided to all adjacent properties.
10. The grading of this lot does not adversely affect neighboring properties or City
infrastructure.
11. Landscaping has been completed prior to survey. If not, please indicatewho will be
responsible for completing landscaping: L&CO dcf �Af
12. Final site cleanup has been completed.
13. 1 personally visited the site as part of the certification process, and in my professional
opinion, the as -built survey is an accurate representation of the site conditions.
14. Based on this information, I certify that (check one):
No Yes 4
No Yes
4CYes
No Yes
No Yes
21 The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached).
❑ The elevations and drainage patterns of the lot/site as measured are in general conformance with the
City approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the
specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a
manner consistent with the approved drainage plan.
Name: Kevin E. Forbes
Email: kevinforbes@frii.com
Phone:
Company: Stewart & Associates Inc.
Address: 204 North Link Lane Unit A-8
- Fort Collins, CO 80524
PE Stamp
Sign and date
NOTE: A complete certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including, but not limited to, drawings of the lot/site showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features, written information/explanation of discrepancies, and other
information necessary to confirm the above certification to:
Email (preferred)
WaterUtilitiesEng@fcgov.com
Mailing Address
Fort Collins Utilities
ATTN: Water Utilities Engineering
281 North College Avenue
Fort Collins, CO 80521
Questions?
970-221-6700
Fort Collins
12/15 Page 2
0
"AS -BUILT" GRADING
LOT 8, BLOCK 1, UN/ON PLACE SUBD/V/S10N
215 URBAN PRA/RlE STREET, FORT COLLINS COLOR4DO
JUNE 10, 2016
I
SCALE: 1 " = 20'
r=175.50' 1=36.75'
delta=l2'00'00'
chdN21'15'00N'
36.;
574-74'4
S
^\ ON +� 90,ee
0p. 6
�� / cPi rei3yy g' �Oi gs6
/ ftv o
Z ON so%
z FAMILY
85 9,
DWELLING ff =
tof = 85.4 y
(85.4) ` tmS
J
(83.08) DENOTES PLAN ELEVA770M PER SITE PLAN
83.08 DENOTES ASBUILT SURVEYED ELEVA770N 9000• s"ts
ON DENOTES DOWNSPOUT AND yeti
DIREC770M OF FLOW L1
VO:.•' / r=265.50' 1=55.60'
-� delta=12'00'00'
899 Z : the N21'15'000E
55.50
LAO Prepared by Stewart & Associates. Inc.
s •E t�yi�
i
L
` UNION, PLACI
c�iinttap t�uw
mmRjownm • ,2mom