Loading...
HomeMy WebLinkAboutSite Certifications - 11/03/2025Page 1 OVERALL SITE and DRAINAGE CERTIFICATION Commercial, Multi-Family and Subdivision Certification Form and Checklist Project Name: Date: Building Permit Numbers: (Commercial or multi-family) Per the requirement in Fort Collins Stormwater Criteria Manual (FCSCM) Chapter 3, Section 3.0 to certify as- built construction to the approved drainage and grading plans, please fill in all applicable items in this Certification Form for Commercial, Multi-Family and Overall Single Family sites. NOTE: several items must be verified during construction. A copy of the approved grading plan must be submitted with the as-built grading plan. (As-built elevations must be written in red next to the approved elevations.) •Use “Yes” for items completed as described. •Use “N/A” for items that are not applicable to the site being certified. •If any blanks are “No,” attach an explanation referencing the item number below. Attach an explanation or description of the as-built condition for any items listed or for anything not listed but shown on the approved construction plans. Provide an as-built redline or Mylar drawing with the following: I.Water Quality and Quantity Detention Basin - FCSCM Ch. 6 and 7 For multiple detention basins on a site, provide the following for each basin separately: A. Volume: As-built topographic verification is attached at 1-foot (or less) contour intervals and volume verification calculations for the water quality capture volume and the 100-year detention storage volume. 1. Detention basin topography was prepared by a professional land surveyor registered in the state of Colorado. 2.Both proposed and as-built contours are shown on the same plan sheet (dashed lines for proposed and solid lines for as-built). 3.All critical spot elevations as shown on the approved construction plans have been verified and the as-built elevations are shown on the plan sheet. 4.Stage-storage-discharge tables are provided on a separate document. 5.Verification that designed drain time is in compliance with Colorado Revised Statute § 37-92- 602(8) is attached and has been uploaded to the Statewide Compliance Portal (tinyurl.com/COCompliancePortal) for approval. Uploaded documents must include: a.The cover sheet from the approved drainage report b.The stamped certification page from the approved drainage report c.As-built topographic survey d.Stamped certification page from the Overall Site & Drainage Certification e.PDF output from the Stormwater Detention and Infiltration Design Data Speadsheet 11/19 Bucking Horse Filing Five 10/29/2025 B2501500 and B2501839 N/A N/A N/A N/A N/A N/A Detention and WQ is existing and not a part of this project Grading/Stormwater Certification Accepted (Certificat e of Occupancy Released) Accepted by: Date : ☐ Escrow was held for CO and is now released we SW - DEREK LUTZ 11/03/2025 MA240135 Page 2 B.Water Quality and Quantity Detention Basin Grading: Attached is as-built verification that there is a minimum 2% positive fall into the concrete trickle pans or flow-line(s) from all areas in the bottom of the detention pond. If there is a “soft pan” in the flow-line, all areas still must meet the minimum 2% grade requirement. 1.Low Flow: Choose one of the following detention basin low flow options as applicable: a. Turf swale for low flow path in detention basin. There is a minimum 2% grade in the flow-line(s) of the detention basin. The flattest as-built grade is . b.Concrete pan for low flow in detention basin. There is a concrete pan installed that meets the grades as shown on the approved construction plans. (Show as-built spot elevations.) c.Soft pan for low flow in detention basin. •Verify and document the soft pan material gradation, trench width and depth - to be verified during construction by engineer. Picture documentation is preferred or engineer’s statement of visual inspection and compliance. (Choose one below.) o There is a soft pan with an underdrain installed that meets the design on the approved construction plans. (Show the underdrain grades, bedding material, geotextile, spot elevations, bends, cleanouts, etc.) o There is soft pan installed without an underdrain but there is a type A or B soil. The soil type must be documented by supplying verification from a registered professional geotechnical engineer. NOTE: Spot elevations are to be within 0.2 ft. +/-. 2. Side Slopes: The as-built side slopes of the detention basin have been calculated and are shown. Indicate the side slope with an arrow and a numerical value (e.g., 6.25:1). The maximum slope allowed is 4:1. Small areas of 3:1 may be acceptable, but slopes steeper than 3:1 must be stabilized or re- graded. Provide documentation if a variance was granted for steeper slopes during the design process. 3.Spillway: The following items must be field verified: a.The location of the spillway is indicated on the as-built plan. b.The width of the spillway is indicated on the as-built plan. c.The elevation(s) of the spillway is shown on the as-built plan. d.A concrete ribbon defines the location and grade of the spillway. e.There is downstream scour protection in the spillway as per the construction plans. Indicate type: (riprap size “D50” gradation and bedding type, geotextile, buried riprap with inches of bury, etc.). f.There are no obstructions in the spillway, such as trees, bushes, sidewalks, landscape features, rocks, etc. 11/19 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Page 3 4.Outlet Structure: a.The orifice plate for the approved release rate is installed with the correct size and location of the orifice. b.The orifice plate for the water quality outlet is installed with the correct hole size, number of rows and columns of holes. c.The bottom hole on both the water quality and quantity outlets are at the bottom of the plate so no water ponds in front of the plate. d.The well screen is the correct material and is installed as shown on the construction plans. e.100-year overflow grate elevation is . (Elev. A on detail D-46) f.The top elevation of the water quality capture volume is . (Elev. B on detail D-46) g.Overflow grate is made of the correct material, has the correct bar spacing, is hinged at the top and bolted at the bottom. h.The bottom of the outlet box has no obstructions or misalignments that will cause it to retain runoff water and is sloped at 2% towards outlet. II.Channels/Swales - FCSCM Ch. 8, Sec. 2.0 and Ch. 9, Sec. 5.0 A. Capacity: The as-built capacity of all the major channels and swales has been verified. They meet or exceed capacity requirements shown in the approved drainage study for this project. 1.All swales are located within the drainage easements as shown on the construction plans. 2.Longitudinal slopes and side-slopes (cross-sections) have been verified. Design criteria requires longitudinal slopes of 2% min. (on vegetated swales) and side-slopes no steeper than 4:1. If these criteria are not met, the certification engineer will write a justification and propose mitigation for each instance or have the issues corrected. If variances to these criteria have previously been approved and are shown on the construction plans, no justification is needed. 3.As-built spot elevations on channels/swales are shown that correspond to spot elevations shown on the approved construction plans. 4.All permanent erosion control measures are installed as shown on the approved construction plans (e.g., drop structures, riprap, TRMs, etc.). (Include pictures and verification of the materials used as part of this verification.) 5.All pans, curbs, storm pipes or other appurtenances appropriately tie into each other in the system. (Pictures at tie-in points suggested.) 6.The minimum freeboard is provided for all channels and swales as shown on the approved construction plans or as identified in the approved drainage study. (Show the freeboard provided on the cross-sections as on the construction plan set or attached as separate documentation.) 7.The low flow portion of all channels or swales is clear of obstructions. (No landscaping, trees, shrubs, sod, etc. infringe on the low flow portion of channels or swales.) 11/19 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A No major swales are a part of this project Page 4 III.Storm Pipes (aka storm drains) - FCSCM Ch. 9, Sec. 4.0 A. Storm Drain Pipe Capacity: The as-built capacity of all pipes installed on this project has been verified and meets or exceeds the capacity requirements shown in the approved drainage study for this project. 1.All storm drain pipe sizes and materials have been verified and are in conformance with the approved construction plans. (Indicate on the plan and profile sheets that they have been verified.) Material and size substitutions must be approved prior to installation. If a pipe size or material was changed during construction, the certification engineer must attach the approval documents or supply them with this certification. Approval documents must include a calculation documenting the capacity equivalency (equal or greater) of the substituted size. 2.The longitudinal slope of the pipe is as shown on the approved construction plans. The acceptable minimum slope is 0.4%. All slopes flatter than the designed slope on the construction plans must be justified with capacity calculations on an attached sheet. 3.The as-built invert elevations have been verified and are shown on the plan and profile sheets of the approved construction plans. B.Storm Drain Pipe Installation Requirements: All pipes are installed in accordance with the approved construction plans and construction specifications. 1.The minimum cover requirements for all pipes have been met as shown on the approved construction plans. These will be called out in critical locations. 2.All encasements and clearances as specified on the approved construction plans have been met. 3.Any specific joint types or construction methods specified on the approved construction plans have been met. (List on a separate sheet and attach to this certification.) IV.Concrete Pans - FCSCM Ch. 8, Sec. 2.0 A. Construction/Installation: All concrete pans have been constructed in accordance with the approved construction plans. 1.The concrete pans are the correct size/width as shown on the approved construction plans. 2.The longitudinal slopes of the pans are as shown on the approved construction plans. The certification engineer must justify or mitigate longitudinal slopes less than the minimum of 0.4% unless a flatter slope was approved and is shown on the approved construction plans. Provide mitigation or justification by separate document. 3.The cross-section of the pan is as shown on the construction plans. (Specifically, the pan cross- section is “V” shaped and meets the side slope shown on the detail.) 4.The concrete pans are a minimum of 6 inches thick without reinforcement and a minimum of 4 inches thick with a minimum of 6X6-W14xW14 reinforcement per detail D20B and D20C. (Provide documentation of the reinforcement used if different than shown on the details or on the approved construction plans.) 5.The spot elevations shown on the concrete pan(s) have been verified and are shown on the as- built drawings. 11/19 Yes Yes Yes Yes Yes Yes N/A N/A Yes Yes Yes N/A N/A Yes A short section of curb along the northern boundary is shown with a slope of 0.3%. This area is fairly minimal and not expected to cause issues concrete pans are curb and gutter, not crosspans Page 5 V. Storm Drain Inlets - FCSCM Ch. 9, Sec. 3.0 A. Construction/Installation: All storm drain inlets have been constructed in accordance with the approved construction plans and construction specifications. 1.The size and type of inlets are consistent with the inlets shown on the approved construction plan. Indicate by writing “Verified” on each inlet on the plan sheet or list on a separate document the inlet number(s), type and size (length). If the inlet installed is other than the one on the approved construction plan detail sheet, provide the name and source of the detail with justification for equal or better capacity. 2.The size of the inlet opening is consistent with the approved detail. (Check height and width.) 3.The elevation of the grate (if applicable) is at the elevation shown on the street profile or as indicated by a spot elevation on the construction plans. 4.The as-built invert elevations of all pipes entering and leaving the inlet are shown on the plan and profile sheets within construction tolerance of 0.2 feet. If substantially different, provide justification and capacity calculations to show the capacity is not affected or propose mitigation. 5.The as-built size of the inlet box is as shown on the construction plans or an explanation or justification is attached. 6.All Type C, R, 13 and 16 inlet covers are stenciled or stamped with the following designation (or an equivalent): NO DUMPING – DRAINS TO POUDRE RIVER. VI.Culverts - FCSCM Ch. 9, Sec. 4.0 A. Construction/Installation: All culverts have been constructed and/or installed in accordance with the approved construction plans and construction specifications. 1.All culvert sizes have been verified as indicated on the as-built construction plans as correct. 2.The culvert material type for all culverts installed is as on the approved construction plans and is indicated on the as-built plans. 3.The as-built invert “in and out” elevations have been verified and are indicated on the as-built construction plans. 4.The culvert headwalls or wing walls have been installed as shown on the approved construction plans. Headwalls or wing walls may be needed in the as-built conditions onsite if the slopes adjacent to the culvert are greater than 4:1. Please note areas needing stabilization in the certification narrative. An alternative to consider is a turf reinforcement mat (TRM). VII.Sub-Drains A. Construction/Installation: All sub-drains shown on the construction plans have been installed in accordance with those plans and the construction specifications. Sub-drains installed with the sanitary sewer are to be verified on the sanitary sewer plan and profile sheets of the construction plans. (NOTE: Indicate any sub-drains installed after the plans were approved on the as-built plans.) 1.The size of the sub-drains are as approved on the construction plans and are indicated on the as- built plans. 2.The type of sub-drain, in particular the perforated and non-perforated sections of the drain, are as indicated on the approved construction plans. 11/19 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes N/A No subdrains are proposed Page 6 3.The cover requirements per the construction plans are provided. 4.The cleanouts have been installed at the locations shown on the construction plans and are accessible for cleaning. (Cleanouts can be buried a maximum of 6 inches deep with their locations marked.) 5.The backfill materials for sub-drains are as shown on the approved construction plans. (This includes the type, depth and width.) 6.The geo-textile liner completely wraps the sub-drain and the permeable backfill material unless shown otherwise on the approved construction plans. (Sub-drain pipe wrapped in a sock filter material is accepted only if approved prior to installation.) VIII.Curb Cuts A. Construction: All curb cut openings are constructed in accordance with the approved construction plans and construction specifications. 1.The size (width) of the curb cut opening is as shown on the approved construction plans. 2.The curb cut openings tie into a downstream swale, pipe, or other appurtenances with a smooth transition and there no obstructions such as riprap or sod impeding the flow downstream of the curb cut. IX.Sidewalk Culverts & Chases A. Construction/Installation: All sidewalk culverts have been installed at the locations shown on the approved construction plans. 1.The size (width and length) of the culverts are as shown on the approved construction plans. 2.The cover plate is a minimum 5/8-inch galvanized plate bolted to a galvanized angle iron per the detail shown on the approved construction plans or per the City’s detail. 3.The sidewalk culvert invert “in and out” elevations have been verified and are indicated on the as-built plans. 4.The sidewalk culvert opening is as shown on the approved construction plans or per the City’s detail. 5.There is a smooth transition both on the inlet and outlet ends of the sidewalk culvert with no obstructions such as riprap or sod impeding the flow into or out of the sidewalk culvert. X. Site Grading - FCSCM Ch. 8 A. Construction: All common open spaces have been graded in accordance with the approved construction plans. 1.The grading on all common open spaces bordering private lots has been verified as correct and the as-built rear lot corner elevations have been shown on the as-built plans. 11/19 N/A Yes Yes N/A Yes Yes Yes Yes Yes sidewalk culverts are private and installed as grated style No curb cuts are proposed Page 7 2.The as-built contours for “overlot grading” are shown on the as-built construction plans for all common open spaces, tracts, outlots, etc. If not in compliance, please attach a narrative describing the situation for noncompliance and when it may be corrected. An escrow for overlot grading may be required. (NOTE: Residential Lot Grading Certification is a separate process from this Overall Site Certification. It is understood that residential lots will be brought to final grade once the foundation is backfilled so they may be lower than the plan shows at this Overall Site Certification stage.) 3.All turf reinforcement mats (TRMs) have been installed as shown on the approved construction plans and the slopes are stabilized. XI.Permanent Erosion Control BMPs - FCSCM Ch. 9, Sec. 7.0 A. Construction: All permanent erosion control BMPs have been installed per the approved construction plans. 1.All riprap has been installed in the locations and sizes indicated on the approved construction plans. 2.All fabric has been installed in the locations and sizes indicated on the approved construction plans. a.All fabric was installed per the details on the approved construction plans. XII.Post-Construction Site Cleanup - FCSCM Ch. 3, Sec. 2.0 A. Construction: All construction debris and obstructions of any kind have been removed from drainage paths. 1.All construction debris has been removed except in staging area(s). 2.All ruts have been smoothed out in all construction areas. 3.All areas needing reseeding have been identified and future stabilization goals have been coordinated with the Erosion Control Inspector and in accordance with FCSCM Vol.2 Chapter 12. Note the area needing stabilization in the narrative. XIII.Certification of LID and Water Quality Facilities - FCSCM Ch. 7 A.Attached are the During Construction Inspection Checklist for Low Impact Development (LID) and other items to be verified during construction, along with pictures and other required documentation. B.Attached is verification of the rain garden and/or sand filter flat surface area(s) and ponding volume(s). This verification includes survey of critical elevations. C.Attached is verification of the underground infiltration required volume(s), weir elevations, orifices, inspection ports and filtering fabric. This verification includes survey of critical elevations. D.All visible LID design features were verified as part of the engineer's site visit. 11/19 N/A N/A Yes Yes N/A Yes Yes N/A N/A N/A N/A N/A N/A substantial as-built spot elevations have been provided to indicate site has been graded to meet the engineering intention all disturbed areas to be landscaped no LID proposed with project 11/19 Page 8 XIV.Certification of Other Permanent BMPs A.The construction of other permanent BMPs not specifically addressed in this certification is in accordance with the approved plan. This may include grade control structures, rundowns, bridges, stream access/improvements, etc. Please specify other permanent BMPs included on this site: XV. Certification and Erosion Control Measures - FCSCM Ch. 3 A. All temporary erosion control measures shall be removed upon stabilization. If at the time of preparing this certification there are any erosion control measures still remaining on the site, please note them in the narrative and verify that they need to remain at this time. If in doubt as to the need for any control measure, please consult with the Erosion Control Inspector at erosion@fcgov.com. XVI.Statement of Compliance - FCSCM Ch. 3 A. This certification is signed and stamped. By signing this form, the engineer(s) attests that he/she has visited and observed the site, and to the best of his/her knowledge, the as-built conditions of the drainage facilities are as described in the above form and in the enclosed as-built plans. B.Failure to properly disclose all known information could result in the rejection of this certification and prevent the release of any and all Stormwater Utility permit holds on Building Permits and/or Certificates of Occupancy within this development. XVII. Signature and Stamp by a Colorado-Registered Professional Engineer Engineer’s contact information: Name: Email: Phone: Company: Address: PE Stamp N/A Stephanie Thomas stephanie.thomas@epsgroupinc.com 970-568-5412 EPS Group 301 N. Howes Street Suite 100 Fort Collins, CO 80521 10/29/25 MARCH 2025 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH BUCKING HORSE FILING FIVE - MINOR AMENDMENT PROJECT TEAM: EPS Group, Inc. Cassandra Ungerman, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE ENGINEER GEOTECHNICAL ENGINEER Earth Engineering Company, Inc. Lester Litton, PE 4396 Greenfield Drive Windsor, Colorado 80550 (970) 545-3908 SHEET INDEX BEING A REPLAT OF LOT 3, BLOCK 4 AND A PORTION OF LOT 2, BLOCK 4, BUCKING HORSE FILING ONE LOCATED IN THE NORTHWEST QUARTER OF SECTION 20, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO EPS Group, Inc. Tharen Helgerson, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970)221-4158 SITE SURVEYOR UTILITY PLANS FOR CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R CS1 COVER SHEET CS2 - CS3 GENERAL & CONSTRUCTION NOTES EX1 EXISTING CONDITIONS & DEMOLITION PLAN PV1 PAVING PLAN GRADING SHEETS OG1 OVERALL GRADING PLAN G1 - G2 GRADING PLAN UTILITY SHEETS U1 UTILITY PLAN ST1 STORM DRAIN 9 PLAN & PROFILE DETAIL SHEETS D1 - D3 DETAILS DRAINAGE SHEETS EC1 EROSION CONTROL EXHIBIT EC2 EROSION CONTROL DETAILS DR1 DRAINAGE EXHIBIT Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 CS1 CO V E R S H E E T 1 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. EPS Group, Inc. assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: PROJECT BENCHMARKS: PROJECT LOCATION S. T I M B E R L I N E R O A D GRE A T W E S T E R N R A I L R O A D MIL E S H O U S E A V E . E. DRAKE ROAD FIELD SURVEY BY: Earth Engineering Consultants, Inc Geotechnical Exploration Report Bucking Horse Development - Southeast Project No. 1122025C Date: July 19, 2012 SUBSURFACE EXPLORATION BY: Additional Survey Information: Northern Engineering, Services Project No. 687-002 Date: July 18, 2014 Washburn Land Surveying, Inc.Washburn Land Surveying, Inc. WS Project No. 2012-003 WS Project No. 2020-004 Date: February 24, 2012 Date: July 14, 2020 Washburn Land Surveying, Inc.Washburn Land Surveying, Inc. WS Project No. 2012-003 WS Project No. 2021-0060 Date: August 24, 2015 Date: March 4, 2022 PROJECT DATUM: NAVD 88 BENCHMARK #1: CITY OF FORT COLLINS BENCHMARK 4-07 SOUTHWEST CORNER OF TIMBERLINE RD. AND BEAR MOUNTAIN DR. DUE NORTH OF NEW POLICE BUILDING ON THE SOUTHWEST CORNER OF A CATCH BASIN. ELEVATION = 4942.84 BENCHMARK #2: CITY OF FORT COLLINS BENCHMARK 17-92 300 FEET SOUTH OF THE SOUTHWEST CORNER OF EAST DRAKE RD. AND TIMBERLINE RD. IN THE TOP OF AN IRRIGATION STRUCTURE. ELEVATION = 4938.70 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.185' BASIS OF BEARING: THE SOUTH LINE OF THE SOUTHWEST ONE-QUARTER OF SECTION 20, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH PRINCIPAL MERIDIAN, MONUMENTED ON THE WEST END BY A 2.5" ALUMINUM CAP IN RANGE BOX MARKED "CITY OF FORT COLLINS 2001 LS 17497" AND ON THE EAST END BY A 3.25" ALUMINUM CAP IN A RANGE BOX MARKED "JR ENGINEERING 2005 PLS 37963", WHICH, ACCORDING TO THE PLAT OF SIDEHILL - FILING TWO, BEARS S89°26'35"E A DISTANCE OF 2641.77'. TRAFFIC ENGINEER Matt Delich, PE Delich Associates 2272 Glen Haven Drive Loveland, Colorado 80538 (970) 669-2061 RVi Planning + Landscape Architecture Shelley LaMastra, PLA 506 S. College Avenue, Unit A Fort Collins, CO 80524 (970) 484-8855 Bucking Horse, LLC Gino Campana 3702 Manhatten Ave., Suite 201 Fort Collins, CO 80526 (970) 229-5900 PLANNER/ LANDSCAPE ARCHITECT DEVELOPER/APPLICANT APPROVED: City Engineer:Approved Sheets Date Water & Wastewater Utility Approved Sheets Date Stormwater Utility Approved Sheets Date Park Planning and Development Approved Sheets Date Traffic Operations Approved Sheets Date Environmental Planner Approved Sheets Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: GAS-----------------Xcel Energy-----------------------------Cory Thelen (970) 225-7843 ELECTRIC--------City of Fort Collins Light & Power--Rob Irish (970) 224-6167 CABLE-------------Comcast----------------------------------Marcus Petty (720) 275-0572 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 WASTEWATER--City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 STORMWATER-City of Fort Collins Utilities----------- Wes Lamarque (970) 416-2418 1 RE C O R D D R A W I N G CT P 08 . 1 9 . 2 0 2 5 REC O R D D R A W I N G I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25 2 RE C O R D D R A W I N G SJ T 10 / 2 9 / 2 5 S F S W F S S W SS SS SS SS SS SSW F S W S W E E E E E E E E E E E E E E E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C S S S W W W W FD C F R.T.U. 19 21 22 509 SF GARAGE 1 168 SF STORAGE 2 131 SF OFFICE 3 28 29 UP X X X X X X X X X X X X X X X X X X X X X X X X X XX X X X X X X X X X W W W S S HYD CC C C S HYDS C C E E E E G GG G G CT V CTV CT V CT V W W W SS SS SS SS E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CT V CT V CT V CT V CT V CTV CTV CTV CTV CTV CTV CTV CTV E CTV CTV CTV W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS G G G G E E E E E E W W W W W W W W F 3 CY 3 CY tras h rec y c ±45 L.F. OF FIRE SERVICE AND VALVE TO BE REMOVED PLUG AT MAIN ±4800 S.F. OF CONCRETE TO BE REMOVED EXISTING TRANSFORMER TO BE RELOCATED EXISTING COMMUNICATIONS PEDESTAL TO BE RELOCATED WATER SERVICE TO BE REUSED EXISTING COMMUNICATIONS PEDESTAL TO BE RELOCATED ± 54 L.F. OF EXISTING COMMUNICATIONS LINE TO BE RELOCATED ± 44 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED ± 64 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED ± 60 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED ± 90 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED EXISTING TRASH ENCLOSURES TO BE REMOVED ± 48 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED EXISTING PARKING STRIPING TO BE REMOVED ± 69 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED / / / / / / / //////////////////// ± 45 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED EXISTING PARKING STRIPING TO BE REMOVED ADA STALL STRIPING TO BE REMOVED GRE A T W E S T E R N R A I L R O A D EXISTING BUILDING EXISTING BUILDING EXISTING 4" SANITARY SERVICE EXISTING ELECTRIC / TELEPHONE / CABLE EXISTING TRANSFORMER EXISTING TRANSFORMER EXISTING TELECOM PEDESTAL (TYP.) EXISTING TREES TO REMAIN (TYP.) EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING TREES TO REMAIN (TYP.) EXISTING FIRE HYDRANT EXISTING 5' SIDEWALK EXISTING STORM LINE EXISTING SIDEWALK CULVERT EXISTING 1.5" WATER METER AND CURB STOP TO BE RELOCATED EXISTING 6" FIRE SERVICE EXISTING 1.5" WATER METER AND CURB STOP TO BE RELOCATED EXISTING 8" WATER LINE EXISTING 6" SANITARY SERVICE / / / / / / / /////////////////////////////////////////////// EXISTING FENCE // /////////////////////////// ////////////////////////// EXISTING PARKING STRIPING TO BE REMOVED EXISTING FENCE ///////////////////////////// / / //////////////////////////// // / ///////////////////////////////// //////// / / / / / / / / / /////////////////// EXISTING FIRE HYDRANT EXISTING 6" SANITARY SERVICE ///////////////////////////////////////// EXISTING LIGHT (TYP.) EXISTING ELECTRIC LINE EXISTING 6' SIDEWALK 26' FL - F L //////////// ±20 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED AND REPLACED ±17 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED AND REPLACED ////////// EXISTING 26' EMERGENCY ACCESS EASEMENT TO BE VACATED BY THIS PLAT EXISTING BUILDING ENVELOPES/EASEMENT EXCLUSION TO BE VACATED BY THIS PLAT EXISTING 8" SANITARY SEWER EXISTING TRASH ENCLOSURE EXISTING CURB CUT EXISTING DETENTION POND 3 (BUCKING HORSE) EXISTING CURB CUT EXISTING BUILDING ENVELOPES/EASEMENT EXCLUSION TO BE VACATED BY THIS PLAT EXISTING 26' EMERGENCY ACCESS EASEMENT TO BE VACATED EXISTING CURB CUT EXISTING CURB CUT EXISTING CURB CUT EXISTING TRASH ENCLOSURE EXISTING 24' EMERGENCY ACCESS EASEMENT TO BE VACATED BY THIS PLAT ±140 L.F. SAWCUT EXISTING SOFT PAN ±645 S.F. OF CONCRETE TO BE REMOVED /////////////// ± 26 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED ±115 S.F. OF CONCRETE TO BE REMOVED ±385 S.F. OF CONCRETE TO BE REMOVED ±147 S.F. OF CONCRETE TO BE REMOVED ±122 S.F. OF CONCRETE TO BE REMOVED ±316 S.F. OF CONCRETE TO BE REMOVED EXISTING 25' EMERGENCY ACCESS EASEMENT TO BE VACATED BY THIS PLAT EXISTING 20' EMERGENCY ACCESS EASEMENT TO BE VACATED BY THIS PLAT ±141 S.F. OF CONCRETE TO BE REMOVED EXISTING 26' EMERGENCY ACCESS EASEMENT TO BE VACATED BY THIS PLAT //////////// ±20 L.F. OF EXISTING CURB AND GUTTER TO BE REMOVED AND REPLACED EXISTING 26' EMERGENCY ACCESS EASEMENT TO BE VACATED BY THIS PLAT ± 100 S.F. OF CONCRETE TO BE REMOVED RELOCATE EXISTING LIGHT POLE EXISTING VALVE REMOVED EX1 DE M O L I T I O N P L A N EX I S T I N G C O N D I T I O N S & 4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 KEYMAP S T I M B E R L I N E R O A D 19 21 22 509 SF GARAGE1 168 SFSTORAGE2 131 SF OFFICE3 28 29 UP BLACKBIRD DRIVE JE S S U P D R I V E BLUE Y O N D E R WAY EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR SAWCUT EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. EXISTING OVERHEAD UTILITY OHE Additional Survey Information: Northern Engineering, Services Project No. 687-002 Date: July 18, 2014 Washburn Land Surveying, Inc.Washburn Land Surveying, Inc. WS Project No. 2012-003 WS Project No. 2020-004 Date: February 24, 2012 Date: July 14, 2020 Washburn Land Surveying, Inc.Washburn Land Surveying, Inc. WS Project No. 2012-003 WS Project No. 2021-0060 Date: August 24, 2015 Date: March 4, 2022 Earth Engineering Consultants, Inc Geotechnical Exploration Report Bucking Horse Development - Southeast Project No. 1122025C Date: July 19, 2012 CONCRETE TO BE REMOVED 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1-JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.REFER TO LANDSCAPE AND IRRIGATION PLANS FOR ADDITIONAL TREE PROTECTION MEASURES. TREE PROTECTION NOTES: TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 1 RE C O R D D R A W I N G CT P 08 . 1 9 . 2 0 2 5 I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25 S W F S S W SS SS SS SS SS SS W F S W S W E E E E E E E E E E E E E E E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C S S S W W W W FD C R.T.U. 19 21 22 509 SF GARAGE 1 168 SF STORAGE 2 131 SF OFFICE 3 28 29 UP W W W W W X X E E G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E X X X X X X X X X X X X X X X X X X X X X X X XX X X X X X X X X X W W W S S HYD C S HYDS C C E E E E G GG G G CT V CTV CT V CT V W W W SS SS SS SS E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CT V CT V CT V CT V CT V CTV CTV CTV CTV CTV CTV CTV CTV E CTV CTV CTV W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS G G G G G E E E E E E E W W W W W W W W F 3 CY 3 CY tras h rec y c DN A A A A A A A A A A A A A A GRE A T W E S T E R N R A I L R O A D EXISTING BUILDING EXISTING BUILDING EXISTING 4" SANITARY SERVICE TO BE USED EXISTING ELECTRIC / TELEPHONE / CABLE EXISTING TRANSFORMER EXISTING TELECOM PEDESTAL (TYP.) EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING FIRE HYDRANT EXISTING 12" STORM DRAIN PROPOSED STAIRS PROPOSED ACCESS RAMPS PROPOSED ACCESS RAMP PROPOSED ACCESS RAMP PROPOSED ACCESS RAMPS EXISTING VERTICAL CURB AND GUTTER 6' S I D E W A L K 7' S I D E W A L K 7' S I D E W A L K 6' S I D E W A L K 6' S I D E W A L K 6' S I D E W A L K 6' S I D E W A L K EXISTING CURB CUT EXISTING CURB CUT EXISTING CURB CUT EXISTING CURB CUT PROPOSED CURB CUT EXTENSIONEXISTING CURB CUT AND RIPRAP RUNDOWN EXI S T I N G 6 ' S I D E W A L K S T I M B E R L I N E R O A D EXISTING DETENTION POND 3 (BUCKING HORSE) EXISTING 18" STORM DRAIN 24' EMERGENCY ACCESS EASEMENT PROPOSED BUILDING 12 PROPOSED BUILDING 11 FFE=24.67 FFE=24.66 W F S W I G W G E E E E CTV CTV CTV CTV W PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS EXISTING SOFT PAN STORM DRAIN LINE 9 SEE SHEET ST1 24' EMERGENCY ACCESS EASEMENT EXISTING CURB CUT PROPOSED ACCESS RAMP PROPOSED ACCESS RAMP 6' S I D E W A L K 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 20' EMERGENCY ACCESS EASEMENT PROPOSED RAMP ST ST ST ST ST ST ST ST ST 1 9 . 7 0 C.O. C.O. CS C.O. C.O. W HYD CS HYD IRR CONTROL W CS IRR CONTROL WV IRR CONTROL E W D W D C.O. C.O. ELEC SS SS W W W DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS FFE: 24.68 TF (6" ASSUMED ABOVE FFE): 25.18 FFE: 24.61 TF (6" ASSUMED ABOVE FFE): 25.11 OG1 OV E R A L L G R A D I N G P L A N 6 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 KEYMAP S T I M B E R L I N E R O A D 19 21 22 509 SF GARAGE1 168 SFSTORAGE2 131 SF OFFICE3 28 29 UP BLACKBIRD DRIVE JE S S U P D R I V E BLUE Y O N D E R WAY PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.ALL AREAS DEDICATED AS "EMERGENCY ACCESS EASEMENT" SHALL BE CAPABLE OF SUPPORTING MINIMUM 80,000 LB LOAD. 7.ALL CHANNEL DRAINS SHALL BE NDS PRO SERIES CHANNEL DRAIN SYSTEM OR APPROVED EQUAL. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK PROPOSED MINOR AMENDMENT 2 RE C O R D D R A W I N G SJ T 10 / 2 9 / 2 5 REC O R D D R A W I N G I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25 W I W G G ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST 19.70 CS HYDCS HYD IRR CON T R O L IRR CON T R O L WV IRR CON T R O L EW D W D ELE C W W E E E E E E/T/ C E/T/ C E/T/ C E XXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X AA A AA A A A A 24. 5 6 24. 3 3 24.5424.26 23.84 24.10 24.20 24.1 2 24.20 21.38 24 . 0 4 21.4 5 24.00 23 . 3 0 24.2 6 24.00 23.75 23.29 22.10 (2 1 . 2 9 ) (21.02) (20 . 2 5 ) (20.60) (19.8 5 ) 20.72 20. 7 9 24.4 7 24 . 4 7 2. 0 % 1. 5 % 17 . 0 % 6' S I D E W A L K 6' S I D E W A L K 24.67 FFE=24.66 FFE=24.67 21 . 2 6 3. 8 % 0.1%20.80 20.65 20.68 20.71 19.80 (19.73) 24 . 2 9 24. 3 5 0. 7 % 1. 0 % 20.42 20. 3 8 20.40 20.47 20.60 20.58 20 . 5 7 20.5 9 (0 . 9 % ) 1.7 % 1.7 % (23.57)(23.42) 23.08 23.0 4 23.78 23.74 24.1 5 (23.55) 24 . 4 7 24. 4 7 0.5%0.8%23.16 23. 1 6 24.75(24.12)6' SIDEWALK 7' SIDEWALK 1. 5 % 1. 9 % 2. 0 % 2. 0 % 2. 0 % 2. 0 % 4.9% 17 . 4 % 16 . 7 % 8.3% 2.3% 2.0% 2.7% 6' SIDEWALK 6' 8'12' EXISTING CURB CUT AND RUNDOWNS EXISTING BUILDING (23 . 2 1 ) 7.1% 11.8% 2.0% (22 . 0 9 ) (20.34) 0.1%0.3% 2. 2 % (0.5%)(0.5%) (24.49) (24.0 2 ) (23 . 9 8 ) (23 . 9 4 ) 24.6 3 24.3724.06 23.90 2.1 %5.6% 2. 0 % 2. 0 % 6' SIDEWALK 2.2 % 1.6% 2. 1 % 1.0 % 2. 3 % 2. 0 % EXISTING BUILDING 2.0 % JESSUP DRIVE EXISTING CURB CUT AND RUNDOWN PROPOSED ACCESS RAMP (TYP.) (1.0%) (4 . 0 : 1 ) 22 . 9 6 LP (1 . 1 % ) (1 . 1 % ) PROPOSED STORM DRAIN EXISTING FENCES 6' 6' 24.2 2 24. 3 4 24.35 2. 0 % 2. 0 % 2. 0 % 1. 5 % 2. 0 % 23.96 23 . 8 4 23.7 6 24. 0 7 21.2723.89 5: 1 22 . 9 % (2.1%) (2.8 % ) (1 . 4 % ) (3 . 4 % ) (1 . 6 % ) 5. 9 % 24.00 24 . 2 6 21 . 3 6 22.3 0 5 - 5.5" STEPS 22 . 3 1 24.5 6 22.4 222.38 2.0% 24.0 0 23.1 6 23.1 6 24.0 0 24.0 0 24.00 24.0 0 EXPOSE FOUNDATION 23.9 8 24.1 0 24.2 0 GROUT PIPE END INTO EXISTING RETAINING WALL 2. 0 % (1 . 6 % ) (11.60) 9. 1 % 7. 1 % 9. 4 % 5.3% 11 . 1 % 4 - 6.5" STEPS STORM DRAIN LINE 9 SEE SHEET ST1 23.22 23.8 4 23.84 23.96 EXTEND STEM WALL TO A MIN. OF 8" ABOVE ADJACENT FINISH GRADE (TYP. ALL LANDSCAPE AREAS ON THIS SIDE OF BLDG) 23.70 23. 5 7 24. 3 5 24.6 5 24.1 5 24 . 5 7 24.67 24.5 7 24.07 23.5 7 24. 0 6 24. 1 8 23. 6 7 23. 9 9 23.87 21.28 20.54 23.22 23.6 7 19.92 (21 . 1 9 ) 24.56 24.66 24.6 6 22.3 8 24.00 24.00 24.00 24.66 24.66 24. 5 6 24.56 24.5 6 24.66 24.5 6 24.3 5 24.15 24.65 24.3 4 24.50 24.66 24.56 24.5 6 24.1 6 23.5 7 24.0 7 23.89 21.3 8 23.7 0 24.20 24.10 23.67 23.4 9 23.7 4 24.5 6 24.1 0 24.20 24.10 23.34 23.7 6 (20.44) 21.05 21.4 8 (20.26) 21.5 7 7.8%2.9% 7.9% 24' EMERGENCY ACCESS EASEMENT 7.6% 24.19 BUILDING 11 23.4 6 23. 5 0 6. 6 % 6 - 5" STEPS 24' EMERGENCY ACCESS EASEMENT PROPOSED ACCESS RAMP 6 - 5" STEPS PROPOSED 24' X 16' SCOURSTOP 20.47 20.64 20.64 20.52 20.56 (19 . 9 8 ) (19.75) 21.87 (20 . 0 2 ) (19 . 9 3 ) (19 . 9 5 ) 2. 0 % 2. 0 % 1. 8 % 2. 0 % (19.9 9 ) (20.1 5 ) (19 . 9 9 ) 23. 6 5 23.60 2. 7 % 1.7 % 2. 0 % 1.1% 2. 3 % 0. 7 % 0. 6 % 1. 4 % 1. 3 % (1 . 3 % ) (2 . 2 % ) 23.66 23.8 6 22 . 2 6 7' SIDEWALK 2. 9 % 21.9 8 4.5 % 4. 2 % 23.78 24.0 7 1. 5 % 1. 5 % 9. 6 % 23.17 21 . 2 0 21. 2 4 21. 2 9 24.1 7 24.1 7 24. 6 7 24. 6 7 24. 6 6 21 . 3 3 OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) 23 . 6 3 24.00 23.83 23.9423.9 0 9. 7 % 7. 6 % 9. 6 % 2.2 % 2.3% 7. 4 % 19.92 49 2 4 . 0 8 AB 492 3 . 9 7 AB 492 3 . 8 4 AB 49 2 4 . 0 9 AB 49 2 4 . 2 3 AB49 2 4 . 2 4 AB 49 2 4 . 1 1 AB 49 2 4 . 0 6 AB 492 3 . 8 1 AB 4923.97 AB 49 2 4 . 0 7 AB 492 3 . 9 1 AB 49 2 3 . 9 3 AB 49 2 3 . 7 7 AB 49 2 4 . 0 4 AB 49 2 4 . 0 4 AB 492 4 . 5 1 AB 492 4 . 5 5 AB492 4 . 4 7 AB 49 2 4 . 4 8 AB49 2 4 . 4 7 AB 49 2 4 . 3 4 AB 4924 . 2 6 AB 492 4 . 4 0 AB 492 4 . 7 5 AB 492 4 . 3 7 AB 492 4 . 2 3 AB 492 4 . 4 0 AB 492 4 . 4 4 AB 492 4 . 2 8 AB 492 0 . 8 3 AB 492 0 . 6 4 AB49 2 0 . 5 9 AB 49 2 0 . 5 6 AB4920 . 6 0 AB 492 0 . 7 5 AB 492 0 . 7 7 AB 49 1 9 . 5 4 AB 49 1 9 . 4 5 AB 49 1 9 . 2 3 AB 491 9 . 2 8 AB4919.2 0 AB 491 9 . 2 6 AB 491 9 . 6 0 AB 491 9 . 7 2 AB 4921.24 AB 4923 . 7 0 AB 49 2 1 . 2 5 AB 49 2 0 . 9 0 AB 4922.18 AB 492 3 . 7 9 AB 492 3 . 3 6 AB 4923.72 AB 49 2 4 . 2 1 AB 49 2 4 . 3 2 AB 4924.52AB 4924.46AB 492 4 . 3 6 AB492 4 . 2 8 AB 49 2 4 . 0 2 AB 49 2 3 . 9 9 AB 492 4 . 0 5 AB4924 . 1 0 AB 492 3 . 7 1 AB 49 2 3 . 8 7 AB 4923.84 AB 492 3 . 6 8 AB 4923 . 5 0 AB 4923.48AB 49 2 3 . 0 6 AB 49 2 3 . 0 8 AB492 3 . 2 0 AB 4923.3 6 AB 49 2 3 . 4 3 AB49 2 3 . 7 1 AB49 2 3 . 8 3 AB 49 2 3 . 8 6 AB 492 4 . 3 3 AB 49 2 4 . 5 7 AB 4924 . 6 0 AB 492 4 . 3 4 AB 492 4 . 5 9 AB 49 2 4 . 2 1 AB 492 4 . 5 7 AB 492 3 . 8 0 AB49 2 3 . 7 9 AB 4921 . 3 5 AB 492 2 . 5 9 AB 492 4 . 1 0 AB 492 4 . 2 7 AB 4924.48 AB 4923.62 AB 4923 . 9 4 AB49 2 3 . 7 8 AB 49 2 3 . 1 3 AB 49 2 3 . 7 3 AB49 2 3 . 6 8 AB49 2 4 . 1 8 AB 492 4 . 3 8 AB49 2 4 . 3 8 AB 49 2 4 . 1 9 AB 492 3 . 3 9 AB 49 2 3 . 9 7 AB 492 3 . 1 8 AB 49 2 2 . 6 3 AB 492 3 . 8 8 AB 49 2 3 . 9 9 AB 492 3 . 4 5 AB 4923 . 3 7 AB 49 2 3 . 2 4 AB49 2 2 . 9 9 AB 49 2 2 . 9 1 AB 49 2 4 . 1 6 AB 492 4 . 2 5 AB 492 3 . 9 5 49 2 3 . 2 2 AB 49 2 3 . 4 5 AB49 2 3 . 4 8 AB 492 0 . 7 2 AB 492 1 . 3 2 AB 492 1 . 2 5 AB 492 0 . 6 4 AB 492 2 . 5 5 AB 49 2 2 . 2 6 AB 49 2 0 . 6 3 AB 492 0 . 6 3 AB 49 2 1 . 2 5 AB 4920.42 AB 4920.38 AB 492 0 . 6 5 AB 49 2 1 . 2 5 AB 49 1 9 . 3 7 AB 49 1 9 . 4 4 AB 491 9 . 3 9 AB 491 9 . 4 9 AB 49 2 1 . 3 5 AB 492 0 . 7 4 AB 4919.91 AB 49 2 0 . 3 2 AB492 1 . 7 1 AB 4921 . 6 6 AB 49 2 4 . 4 9 AB 4924.55AB 4924.5 7 AB 49 2 4 . 5 5 AB 49 2 2 . 1 4 AB 4921.53 AB 49 2 1 . 3 8 AB 4921 . 9 2 AB 49 2 1 . 0 6 AB 4921.02 AB 49 2 0 . 9 3 AB 49 2 0 . 7 8 AB 49 2 0 . 3 2 AB 492 0 . 2 5 AB 492 1 . 7 2 AB 492 0 . 3 4 AB 49 2 0 . 3 7 AB 492 3 . 9 7 AB 492 3 . 8 0 AB 49 2 4 . 0 0 AB 492 3 . 7 3 AB 492 3 . 7 7 AB 49 2 3 . 7 9 AB 1.2%0.6%1.1% 1.2% 0.4% 0.8% 492 3 . 5 4 AB 4923 . 2 6 AB 4923.21 AB 4923.44 AB 492 3 . 5 8 AB 4916.1 3 AB 49 2 2 . 9 5 AB 492 3 . 3 6 AB 4923 . 0 2 AB 492 2 . 8 5 AB 491 9 . 8 0 AB 0.3% 6.0 % 5. 1 % 4.8% 3.5%1.4% 2.0% 2.0% 3.1% 10.8%17.3% 2.0 % 2. 9 % PROPOSED 5" CHANNEL DRAIN 492 4 . 5 2 AB 49 2 3 . 7 7 AB 49 2 3 . 7 8 AB 492 4 . 0 8 AB 49 2 4 . 4 1 AB 492 3 . 8 2 AB 492 3 . 8 5 AB 49 2 4 . 5 4 AB 492 4 . 4 9 AB 492 4 . 1 5 AB FFE: 24.68 TF (6" ASSUMED ABOVE FFE): 25.18 FFE: 24.63 TF (6" ASSUMED ABOVE FFE): 25.11 6" PER BUILDING DESIGN 1.4% 11 . 4 % 6.2 % 8.3 % 6. 8 % 3. 7 % 6.8% 4.5% G1 GR A D I N G P L A N 7 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MA T C H L I N E - S E E S H E E T G 2 Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 KEYMAP S T I M B E R L I N E R O A D 19 21 22 509 SF GARAGE1 168 SFSTORAGE2 131 SF OFFICE3 28 29 UP BLACKBIRD DRIVE JE S S U P D R I V E BLUE Y O N D E R WAY PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.ALL AREAS DEDICATED AS "EMERGENCY ACCESS EASEMENT" SHALL BE CAPABLE OF SUPPORTING MINIMUM 80,000 LB LOAD. 7.ALL CHANNEL DRAINS SHALL BE NDS PRO SERIES CHANNEL DRAIN SYSTEM OR APPROVED EQUAL. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK PROPOSED MINOR AMENDMENT 2 RE C O R D D R A W I N G SJ T 10 / 2 9 / 2 5 REC O R D D R A W I N G I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25 G GST ST ST ST ST ST ST ST ST ST ST ST CS W HYD W CS IRR CON T R O L WV IRR CON T R O L D W D W W W W E E E E E E E/T/ C E/T/ C E/T/ C XX X X XXXXXX UP 3 CY 3 CY trash recyc DN AA A A A AA 24.20 24.1 2 24.20 6' S I D E W A L K 24.67 24.67 21.76 FFE=24.67 FFE=24.67 21 . 2 6 20.65 20.68 20.71 20.70 20.68 19.80 (19.73) (19.73) 20.2 0 (20.73) 21.45 (21.23)22.14 22. 6 1 24. 3 5 0. 7 % 1. 0 % 20.42 20. 3 8 20.40 20.47 1.7 % 1.7 % (1 . 1 % ) (1 . 3 % ) (1 . 2 % ) 20.53 20.4 8 20. 4 7 20.5 0 22.3 2 21.8 4 2.5% 1.1% 23. 6 3 23 . 5 1 23 . 3 7 24.35 24.67 23.92 24 . 6 0 24. 6 7 24 . 5 9 (23.57)(23.42) 23.08 23.0 4 23.78 23.74 24.1 5 (23.55) 24 . 4 7 24. 4 7 0.5%0.8%23.16 23. 1 6 24.2 3 24.2 8 3.5 % 8.4%24.75(24.12) 1. 7 % 1. 8 % 1. 7 % 1. 5 % 1. 9 % 17 . 4 % 8.3% 2.0% 2.7%2.3 % 2. 0 % 4.5% 2.1% 2.1% (1.4 % ) 12' EXISTING CURB CUT AND RUNDOWNS 0.3% 2. 0 % 6' SIDEWALK 2.0 % EXISTING BUILDING JESSUP DRIVE JE S S U P D R I V E PROPOSED ACCESS RAMP (TYP.) PROPOSED ACCESS RAMP (TYP.) 21.23 2.1% 1. 4 % 3.6% 2. 8 % (24 . 5 6 ) (24.3 3 ) (23.1 6 ) (2 3 . 8 1 ) (21.97) (22.14) (3.0:1 ) (3 . 0 : 1 ) (4 . 0 : 1 ) (2.2%) (1.1%) (1.0%) (4 . 0 : 1 ) (3 . 9 : 1 ) (3 . 9 : 1 ) (1. 8 % ) (2.6% ) (1. 8 % ) EXISTING DETENTION POND 3 (BUCKING HORSE) EXISTING TRASH ENCLOSURE 22 . 9 6 LP 10' (1 . 1 % ) (1 . 1 % ) (1 . 1 % ) (1 . 1 % ) PROPOSED STORM DRAIN 2. 0 % 23 . 8 4 23.7 6 24. 0 7 21.27 GROUT PIPE END INTO EXISTING RETAINING WALL 2. 0 % (1 . 6 % ) 3.6 % 23.41 22 . 7 6 24. 4 7 23 . 2 2 23.73 24. 4 5 24.44 23. 6 8 24.2 8 24 . 5 4 24.88 (11.60) 23.08 9. 1 % 7. 1 % 9. 4 % 3 - 5" STEPS 1.5%1.3% STORM DRAIN LINE 9 SEE SHEET ST1 23.22 23.8 4 23.84 23.96 EXTEND STEM WALL TO A MIN. OF 8" ABOVE ADJACENT FINISH GRADE (TYP. ALL LANDSCAPE AREAS ON THIS SIDE OF BLDG) 23.70 23. 5 7 24. 3 5 24.6 5 24.1 5 24 . 5 7 24.67 24.5 7 24.07 23.5 7 24. 0 6 24. 1 8 23. 6 7 23. 9 9 23.87 21.28 20.54 20.67 21.12 (20.25) 21.62 21.9222.05 22.68 23. 2 0 24 . 5 7 24. 5 6 24 . 5 9 24 . 6 7 24. 6 7 23.22 23.6 7 23.7 6 23.9 9 23.32 24' EMERGENCY ACCESS EASEMENT 23.4 6 23. 5 0 6. 6 % PROPOSED ACCESS RAMP (TYP.) 8.5% 5.8% 24' EMERGENCY ACCESS EASEMENT 5.5 % 5.6% 6.4%23.2 0 24.6 7 22 . 8 4 6 - 5" STEPS BUILDING 12 7.2% PROPOSED ACCESS RAMP PROPOSED 24' X 16' SCOURSTOP 20.52 20.56 20.5 9 20.57 20.49 (20.1 7 ) (20.3 9 ) (20.7 1 ) (20.34) 21.4 1 1. 8 % 2. 0 % (19.9 9 ) (20.1 5 ) (19 . 9 9 ) 1. 4 % 1. 3 % 1. 6 % 0. 9 % 1. 0 % 2. 0 % 2. 0 % 24.1 8 23 . 8 6 23.66 23.8 6 22 . 2 6 1.8% 26' EMERGENCY ACCESS EASEMENT 7' SIDEWALK 2. 9 % DRAIN SWALE THROUGH HANDICAP RAMP EXTEND STEM WALL TO A MIN. OF 8" ABOVE ADJACENT FINISH GRADE (TYP. ALL LANDSCAPE AREAS ON THIS SIDE OF BLDG) 23.78 24.0 7 1. 5 % 1. 5 % 9. 6 % 23.17 PROPOSED 5" CHANNEL DRAIN (SEE NOTE 7) PROPOSED 5" CHANNEL DRAIN (SEE NOTE 7) 24.4 5 24.3 7 1.5% 24.0 1 23 . 8 3 23.65 OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) 21 . 2 9 21 . 2 0 21. 2 4 21. 2 9 24.1 7 24.1 7 24. 6 7 24. 6 7 22. 8 8 24. 6 6 24. 6 3 24. 6 3 24. 6 4 21 . 3 3 21.23 2.2 % OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 7) 23.9423.9 0 24.63 24 . 6 5 9. 7 % 5. 7 % 23 . 9 1 24. 6 7 7. 6 % 9. 6 % 2.2 % 3. 0 % 19.92 492 4 . 4 0 492 4 . 4 4 4921.24 AB 4923 . 7 0 AB 49 2 1 . 2 5 AB 49 2 0 . 9 0 AB 4922.18 AB 492 3 . 7 9 AB 492 3 . 3 6 AB 4923.72 AB 49 2 4 . 2 1 AB 49 2 4 . 3 2 AB 4924.52AB 4924.46AB 492 4 . 3 6 AB492 4 . 2 8 AB 49 2 4 . 0 2 AB 49 2 3 . 9 9 AB 492 4 . 0 5 AB4924 . 1 0 AB 492 3 . 7 1 AB 49 2 3 . 8 7 AB 4923.84 AB 492 3 . 6 8 AB 4923 . 5 0 AB 4923.48AB 49 2 3 . 0 6 AB 49 2 3 . 0 8 AB492 3 . 2 0 AB 4923.3 6 AB 49 2 3 . 4 3 AB 492 3 . 8 8 AB 49 2 3 . 9 9 AB 492 3 . 4 5 AB 4923 . 3 7 AB 49 2 3 . 2 4 AB49 2 2 . 9 9 AB 49 2 2 . 9 1 AB 49 2 4 . 1 6 AB 492 4 . 2 5 AB 49 2 4 . 5 3 AB 492 3 . 9 5 AB 49 2 4 . 0 5 AB 49 2 4 . 0 8 AB 492 4 . 0 9 AB 49 2 4 . 6 7 AB 49 2 4 . 3 7 AB 49 2 4 . 0 4 AB 49 2 4 . 3 8 AB 49 2 4 . 5 5 AB 49 2 3 . 9 2 AB 4923 . 8 3 AB 49 2 3 . 7 5 AB 49 2 3 . 6 9 AB 49 2 3 . 6 6 AB 49 2 3 . 8 3 AB 49 2 4 . 3 6 AB 492 4 . 3 6 AB 49 2 3 . 7 5 AB 49 2 3 . 7 5 AB 49 2 3 . 7 4 AB 4924.33AB 49 2 4 . 2 4 AB 49 2 3 . 6 6 AB 492 3 . 6 2 AB 4924.2 0 AB 49 2 4 . 2 5 AB 4924.3 3 AB 49 2 3 . 3 7 AB 492 3 . 9 7 AB 49 2 3 . 4 4 AB 492 3 . 4 2 AB 49 2 3 . 2 9 AB 49 2 3 . 3 4 AB 4923.31 AB 49 2 3 . 2 2 AB 49 2 0 . 6 3 AB 492 0 . 6 3 AB 49 2 1 . 2 5 AB 4920.42 AB 4920.38 AB 492 0 . 6 5 AB 49 2 1 . 2 5 AB 492 1 . 1 3 AB 492 0 . 5 4 AB 49 2 0 . 5 7 AB 492 1 . 1 3 AB 49 2 1 . 2 0 AB 49 2 0 . 6 6 AB 49 2 0 . 4 6 AB 49 2 0 . 4 5 AB 4920.45AB 4920.43 AB 492 0 . 6 3 AB 49 2 1 . 2 1 AB 49 2 1 . 1 6 AB 492 0 . 6 1 AB 49 2 1 . 1 8 AB 492 0 . 6 1 AB 49 1 9 . 4 1 AB 49 1 9 . 4 4 AB 491 9 . 7 3 AB491 9 . 8 9 AB 491 9 . 6 1 AB 49 1 9 . 3 7 AB 49 1 9 . 4 4 AB 491 9 . 3 9 AB 491 9 . 4 9 AB 49 2 0 . 3 0 AB 49 2 0 . 2 7 AB 492 0 . 4 7 AB 49 2 0 . 6 2 AB 492 0 . 8 1 AB 492 1 . 1 1 AB 492 1 . 1 6 AB 49 2 1 . 3 5 AB 4921.59 AB 492 2 . 1 6 AB 492 2 . 5 3 AB 49 2 2 . 2 7 AB 49 2 2 . 7 2 AB 49 2 3 . 1 1 AB 4923.11 AB 4923 . 2 5 AB 492 3 . 0 6 AB 49 2 2 . 3 8 AB 49 2 2 . 2 9 AB 492 1 . 9 9 AB49 2 4 . 3 3 AB 492 4 . 4 2 AB 492 2 . 6 7 AB 4921 . 7 9 AB 4921.69 AB 492 0 . 3 4 AB 49 2 0 . 3 7 AB 49 1 9 . 4 5 AB 49 1 9 . 9 1 AB 49 2 0 . 1 7 AB 492 1 . 0 3 AB 492 0 . 6 4 AB 492 0 . 6 0 AB 492 0 . 4 8 AB 492 0 . 3 4 AB 492 0 . 2 4 AB 1.2%0.6%1.1% 0.8% 492 3 . 5 4 AB 492 3 . 5 8 AB 4916.1 3 AB 491 9 . 8 0 AB 0.3%4.4% 1.3% 0.3% 3.0% 2.8 % 1. 6 % 1. 2 % 1.7% 2.0% 3.1% 10.8%17.3% 1.7% 2.0 % 2. 9 % PROPOSED 5" CHANNEL DRAIN PROPOSED 5" CHANNEL DRAIN 492 4 . 5 2 AB 492 3 . 7 1 AB 49 2 3 . 9 0 AB 49 2 4 . 2 7 AB 49 2 4 . 1 4 AB49 2 4 . 2 8 AB 49 2 4 . 2 2 AB 49 2 3 . 7 7 AB 49 2 3 . 7 8 AB 492 4 . 0 8 AB 49 2 4 . 4 1 AB 492 3 . 8 2 AB 492 3 . 8 5 AB 49 2 4 . 5 4 AB 492 4 . 4 9 AB 492 4 . 1 5 AB 49 2 4 . 3 7 AB 49 2 4 . 7 1 AB 49 2 4 . 6 1 AB 49 2 4 . 2 5 AB 49 2 4 . 5 4 AB 49 2 4 . 5 9 AB 49 2 4 . 4 4 AB 49 2 4 . 8 1 AB 49 2 4 . 8 9 AB 49 2 4 . 6 9 AB 492 4 . 5 8 AB 492 4 . 5 6 AB550 8 6 492 4 . 6 1 1 ff FFE: 24.63 TF (6" ASSUMED ABOVE FFE): 25.11 FFE: 24.61 TF (6" ASSUMED ABOVE FFE): 25.11 49 2 4 . 0 0 AB 6" PER BUILDING DESIGN 6" PER BUILDING DESIGN 5.9 % 9. 1 % 0.4% 1.2%1.4%1.4% 11 . 4 % 6.2 % 1.0%1.0%6. 9 % 4. 6 % 7. 6 % 7. 4 % 1. 2 % 8.3 % 6. 8 % 3. 7 % 24.36 G2 GR A D I N G P L A N 8 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MA T C H L I N E - S E E S H E E T G 1 Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 KEYMAP S T I M B E R L I N E R O A D 19 21 22 509 SF GARAGE1 168 SFSTORAGE2 131 SF OFFICE3 28 29 UP BLACKBIRD DRIVE JE S S U P D R I V E BLUE Y O N D E R WAY PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.ALL AREAS DEDICATED AS "EMERGENCY ACCESS EASEMENT" SHALL BE CAPABLE OF SUPPORTING MINIMUM 80,000 LB LOAD. 7.ALL CHANNEL DRAINS SHALL BE NDS PRO SERIES CHANNEL DRAIN SYSTEM OR APPROVED EQUAL. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK PROPOSED MINOR AMENDMENT 2 RE C O R D D R A W I N G SJ T 10 / 2 9 / 2 5 REC O R D D R A W I N G I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25 1 1 UP D A T E D A C C E S S A N D G R A D I N G SJ T 08 / 1 9 / 2 5 ST ST ST ST ST ST ST ST ST 1 9 . 7 0 C.O. C.O. CS C.O. C.O. W HYD CS HYD IRR CONTROL W CS IRR CONTROL WV IRR CONTROL E W D W D C.O. C.O. ELEC SS SS W W W S W F S S W SS SS SS SS SS SSW F S W S W E E E E E E E E E E E E E E E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C S S S W W W W FD C R.T.U. 19 21 22 509 SF GARAGE 1 168 SF STORAGE 2 131 SF OFFICE 3 28 29 UP W W W W W X X G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E X X X X X X X X X X X X X X X X X X X X X X XX X X X X X X X X X W W W S S HYD C S HYDS C C E E E E G GG G G CT V CTV CT V CT V W W W SS SS SS SS E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CT V CT V CT V CT V CT V CTV CTV CTV CTV CTV CTV CTV CTV E CTV CTV CTV W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS G G G G G E E E E E E E W W W W W W W W F 3 CY 3 CY tras h recy c DN A A A A A A A A A A A A A A EXISTING 8" WATER LINE EXISTING 6" SANITARY SERVICE EXISTING ELECTRIC / TELEPHONE / CABLE EXISTING TRANSFORMER EXISTING TRANSFORMER EXISTING 2' SIDEWALK CULVERT EXISTING 6" SANITARY SERVICE CONNECT TO EXISTING ELECTRIC AND CABLE LINES 6' S I D E W A L K EXISTING 6' SIDEWALK EXIST I N G S O F T T R A I L 26' EMERGENCY ACCESS EASEMENT 20' EMERGENCY ACCESS EASEMENT 6' S I D E W A L K EXISTING 15" RCP GRE A T W E S T E R N R A I L R O A D EXISTING BUILDING EXISTING BUILDING EXISTING 4" SANITARY SERVICE EXISTING ELECTRIC / TELEPHONE / CABLE EXISTING TELECOM PEDESTAL (TYP.) EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT W F S W I G W G E E E E CTV CTV CTV CTV W RELOCATED 11 2" WATER METER EXISTING 6" FIRE SERVICE 7' S I D E W A L K 6' S I D E W A L K 7' S I D E W A L K 6' S I D E W A L K 6' S I D E W A L K 6' S I D E W A L K 6' S I D E W A L K RELOCATE EXISTING CURB STOP N:18926.09 E:10528.27 PROPOSED TYPE R INLET PROPOSED 11 2" WATER SERVICE PROPOSED 4' STORM MH CONNECT TO EXISTING SANITARY SERVICE PROPOSED 3 4" WATER METER PROPOSED 6" SANITARY SERVICE PROPOSED BUILDING 11 PROPOSED BUILDING 12 EXISTING DETENTION POND 3 (BUCKING HORSE) EXISTING 2' SOFT PAN PROPOSED 3 4" WATER SERVICE INLET 9-2.6 INV.=4919.96 FG=4923.30 15.95 LF 12" HDPE @ 0.50% BEND 9-2.5 INV.=4919.89 FG=4923.96 11.43 LF 12" HDPE @ 0.50% BEND 9-2.4 w/ CO INV.=4919.83 FG=4924.38 6.44 LF 12" HDPE @ 0.50% 9.37 LF 12" HDPE @ 1.00% INLET 9-2.3-1 INV.=4919.89 FG=4923.67 TEE 9-2.2 INV.=4919.69 FG=4923.98 INLET 9-2.2-1 INV.=4919.79 FG=4923.49 21.10 LF 12" HDPE @ 0.50% 61. 9 0 L F 1 2 " H D P E @ 0 . 5 0 % TEE 9-2.1 INV.=4919.38 FG=4923.98 12.78 LF 12" HDPE @ 1.00% INLET 9-2.1-1 INV.=4919.51 FG=4923.34 31.0 8 L F 12" H D P E @ 0. 5 0 % SANITARY SEWER CLEANOUT N:19197.28 E:10256.62 SANITARY SEWER CLEANOUT N:19236.62 E:10216.91 PROPOSED ELECTRIC AND CABLE LINES CONNECT TO EXISTING TRANSFORMER (PENDING ELECTRIC LOAD ANALYSIS) EXISTING 11 2 " WATER SERVICE PROPOSED 3 4" IRRIGATION METER AND SERVICE TEE 9-2.3 INV.=4919.80 FG=4924.16 EXTEND FIRE SERVICE TO BUILDING CONNECT TO EXISTING WATER SERVICE 24' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT PIPE END 2-2 INV.=4923.64 FG=4923.65 PIPE END 1-2 INV.=4923.58 FG=4923.58 PIPE END 2-1 FG=4923.60 PIPE END 1-1 FG=4923.54 9.00 LF 8" HDPE @ 0.44% 9.01 LF 8" HDPE @ 0.44% 25' EMERGENCY ACCESS EASEMENT PROPOSED TRANSFORMER ELECTRIC METER LOCATION 15.53 LF 12" HDPE @ 5.00% INLET 9-2A INV.=4921.26 FG=4923.66 ELECTRIC METER LOCATION 11 2" x 3 4" REDUCER TO BE INSTALLED AFTER CURB STOP PROPOSED 5" CHANNEL DRAIN (NDS PRO SERIES CHANNEL DRAIN SYSTEM OR APPROVED EQUAL) PROPOSED 5" CHANNEL DRAIN (NDS PRO SERIES CHANNEL DRAIN SYSTEM OR APPROVED EQUAL) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 12) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 12) OPTIONAL 5" CHANNEL DRAIN (SEE NOTE 12) 10.49 LF 12" HDPE @ 1.00% AS-BUILT CURB STOP N:18926.28 E:10528.84 AS-BUILT WATER METER N:18929.18 E:10530.34 AS-BUILT WATER RISER N:18938.34 E:10532.90 AS-BUILT CLEANOUT N:18993.31 E:10467.31 AS-BUILT CLEANOUT N:18992.13 E:10466.28 AS-BUILT CURB STOP N:19118.12 E:10322.96 AS-BUILT WATER METER N:19124.65 E:10329.01 AS-BUILT CLEANOUT N:19194.03 E:10258.39 AS-BUILT CURB STOP N:19268.45 E:10152.93 AS-BUILT WATER METER N:19271.93 E:10156.98 AS-BUILT CLEANOUT N:19255.47 E:10221.82 AS-BUILT CLEANOUT N:19253.84 E:10220.60 AS-BUILT CLEANOUT N:19235.96 E:10216.75 3 4" TYPE K COPPER 3 4" TYPE K COPPER 1.5" TYPE K COPPER 3 4" TYPE K COPPER 8" HDPE C900 FIRE LINE EXTENSION TO RISER 4923.58 4921.37 30.5 4 L F @ 5.22% 4919.46 @ 0 . 5 2 % 13.78 LF 13.78 LF @ 0.66% 4919.55 4923.26 61. 3 3 L F @ 0 . 5 9 % 4919.77 @ 0.53% 9.42 LF 4919.82 4923.22 @ 0.53%20.71 LF 4919.88 @ 3.32% 8.44 LF 4920.16 4923.45 @ 0.51% 7.87 LF 4919.92 10.19 LF @ 1.57% 4920.08 15.71 LF @ 0.50% 4920.16 4923.23 4922.85 4923.02 @ 1.54% 11.02 LF 4922.95 4923.37 10.85 LF @ 3.99% U1 UT I L I T Y P L A N 9 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 KEYMAP S T I M B E R L I N E R O A D 19 21 22 509 SF GARAGE1 168 SFSTORAGE2 131 SF OFFICE3 28 29 UP BLACKBIRD DRIVE JE S S U P D R I V E BLUE Y O N D E R WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS STANDARDS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 4.5 FEET TO 5.5 FEET DEPTH FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 12.CHANNEL DRAINS SHALL BE NDS PRO SERIES CHANNEL DRAIN SYSTEM OR APPROVED EQUAL. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV A PROPOSED MINOR AMENDMENT 1 RE C O R D D R A W I N G CT P 08 . 1 9 . 2 0 2 5 2 RE C O R D D R A W I N G SJ T 10 / 2 9 / 2 5 REC O R D D R A W I N G I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25 ST ST ST ST ST ST ST ST ST CS HYD IRRCON T R O L WV IRRCON T R O L D W D C.O . SS DS DS DS DSDS DS DS DS DS E E E E E E/T / C E/T / C X X X X X X X X X X X HYD C S SS E E E E E CT V CT V CT V CT V CT V CT V CT V CT V CT V CT V E CT V CTV CTV W W W W W W SS SS SS SS SS SS SS SS W W W W F A A A A A W I INLET 9-4 STA 12+37.29 N: 19078.84 E: 10338.05 STMH 9-3 STA 11+83.42 N: 19118.08 E: 10301.15 HEADWALL 9-1 STA 10+00.00 N: 19248.38 E: 10430.24 53.87 LF 18" HDPE @ 0.50% GROUT PIPE END INTO EXISTING RETAINING WALL BUILDING 12 JE S S U P D R I V E EXISTING 8" WATER EXISTING SANITARY SEWER EXISTING SIDEWALK CHASE EXISTING STORM DRAIN EXISTING RETAINING WALL EXISTING FENCES EXISTING CURB CUT EXISTING SOFT PAN INLET 9-2 STA 11+37.50 N: 19150.70 E: 10333.46 137.50 LF 18" HDPE @ 2.00% 45.92 LF 18" HDPE @ 2.00% 4905 4910 4915 4920 4925 4930 4935 4940 4945 4905 4910 4915 4920 4925 4930 4935 4940 4945 9+5010+0011+0012+0012+50 IN L E T 9 - 4 ST A 1 2 + 3 7 . 2 9 FL . E L 4 9 2 3 . 5 ± IN V . O U T 4 9 1 9 . 9 2 ( N W ) 53.87 LF 18" HDPE @ 0.50% ST M H 9 - 3 ST A 1 1 + 8 3 . 4 2 RI M 4 9 2 3 . 4 ± IN V . I N 4 9 1 9 . 6 5 ( S E ) IN V . O U T 4 9 1 9 . 6 5 ( N E ) 45.92 LF 18" HDPE @ 2.00% 137.50 LF 18" HDPE @ 2.00% HE A D W A L L 9 - 1 ST A 1 0 + 0 0 . 0 0 IN V . 4 9 1 5 . 9 8 ( S W ) PROPOSED GROUND EXISTING GROUND 100-YR HGL IN L E T 9 - 2 ST A 1 1 + 3 7 . 5 0 IN V . 4 9 1 8 . 7 3 ( S W ) IN V . 4 9 1 9 . 2 3 ( N W ) IN V . 4 9 2 0 . 4 8 ( S E ) IN V . 4 9 1 8 . 7 3 ( N E ) ST1 PL A N & P R O F I L E ST O R M D R A I N 9 10 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 STORM DRAIN 9 PROFILE SCALE: Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 KEYMAP S T I M B E R L I N E R O A D 19 21 22 509 SF GARAGE1 168 SFSTORAGE2 131 SF OFFICE3 28 29 UP BLACKBIRD DRIVE JE S S U P D R I V E BLUE Y O N D E R WAY EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY INLET SCHEDULE: PROPOSED MINOR AMENDMENT INLET SCHEDULE Inlet/Basin ID Inlet Size Grate Type 9-2 Nyloplast 18" Drain Basin 1899CGD 9-2A Nyloplast 12" Standard 1299CGD 9-2.1-1 Nyloplast 12" Standard 1299CGD 9-2.2-1 Nyloplast 12" Standard 1299CGD 9-2.3-1 Nyloplast 12" Standard 1299CGD 9-2.6 Nyloplast 12" Standard 1299CGD 9-4 5' - Type R Per Detail STORM 9 2 RE C O R D D R A W I N G SJ T 10 / 2 9 / 2 5 REC O R D D R A W I N G I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25 56.15 LF 49 2 2 . 9 9 ± 49 2 0 . 0 6 ( S W ) @ 0.73% 138.94 LF @ 1.99% 49 2 3 . 5 4 49 1 9 . 6 5 ( S E ) 49 1 9 . 5 5 ( N E ) RI M : 4 9 2 3 . 5 5 49 1 8 . 9 4 ( S W ) 49 1 9 . 3 0 ( N W ) 49 2 0 . 6 5 ( S E ) 49 1 8 . 9 0 ( N E ) 49 1 6 . 1 4 ( S W ) 43.76 LF @ 1.39% 56.15 LF @ 0.73%138.94 LF @ 1.99% 43.76 LF @ 1.39% F S W I W G W W SS SS SS SS SSSSSS W W W W W W W W F IR F W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SSW F W W E/T/C E/T/C E/T/C E/T/C E/T/C W W W W W FD C FDC FDC FW R.T.U. 19 21 22 509 SF GARAGE 1 168 SF STORAGE 2 131 SF OFFICE 3 28 29 UP W W W W W W W W W W W W W W W W W W W W W W W W X X X E E G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X W UP WF 3 CY 3 CY tras h recy c DN A A A A A A A A A A A A A A A1.2 A5 A3 A4 A2 A6 A1.1 POND 3 STORM DRAIN 9 SEE SHEET ST1 EXISTING CURB CUT EXISTING CURB CUT EXISTING CURB CUT EXISTING CURB CUT A4 A1.2 A1.2 A1.2 A1.2 A1.1 A5 A6 A3 A2 A A DR1 DR A I N A G E E X H I B I T 16 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION LEGEND: PROPERTY BOUNDARY DESIGN POINT PROPOSED STORM SEWER EXISTING STORM INLET PROPOSED CURB & GUTTER 1.REFER TO "DRAINAGE MEMO FOR BUCKING HORSE FILING FIVE - MINOR AMENDMENT DATED FEBRUARY 25, 2025" FOR ADDITIONAL INFORMATION EXISTING STORM MANHOLE D A2 a3 (4:1) PROPOSED MAJOR CONTOUR EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED SLOPE (RISE:RUN)4:1 DRAINAGE BASIN MINOR/MAJOR COEFF. DRAINAGE BASIN ID EXISTING SLOPE (RISE:RUN) EXISTING CONCENTRATED FLOW PROPOSED CONCENTRATED FLOW PROPOSED OVERLAND FLOW NOTES: STEXISTING STORM SEWER Sheet BU C K I N G H O R S E F I L I N G F I V E - M I N O R A M E N D M E N T of 16 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 03/05/25 NORTH ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C10 C100 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q10 (cfs) Q100 (cfs) A1.1 A1.1 1.77 0.60 0.60 0.75 6.8 6.8 5.0 2.8 4.7 13.2 A1.2 A1.2 4.01 0.53 0.53 0.66 13.8 13.8 12.1 4.1 7.1 19.0 A2 A2 0.92 0.26 0.26 0.32 5.0 5.0 5.0 0.7 1.2 3.0 A3 A3 1.70 0.26 0.26 0.32 8.0 8.0 7.5 1.1 1.8 4.8 A4 A4 1.14 0.80 0.80 1.00 5.0 5.0 5.0 2.6 4.4 11.3 A5 A5 1.44 0.72 0.72 0.90 12.8 12.8 7.2 2.1 3.6 11.5 A6 A6 1.19 0.72 0.72 0.90 7.3 7.3 5.0 2.2 3.7 10.6 DETENTION POND SUMMARY SWALE SECTIONS SWALE SUMMARY TABLE Note: Basins A2, A3, A5, and A6 are not being modified with the current project. Values shown are from the previously approved drainage report Note: Pond volumes shown are per the previously approved drainage report and are shown for reference only. No ponds have been modified with the current project. Note: Swales shown are per the previously approved drainage report and are shown for reference only. No swales have been modified with the current project. 2 RE C O R D D R A W I N G SJ T 10 / 2 9 / 2 5 REC O R D D R A W I N G I, Stephanie Thomas, certify all Public Water, Wastewater and Stormwater system improvements shown herein, including any noted changes or revisions, are in general conformance with the design/construction documents, pursuant to this Record Drawing copy of the final Utility Plans. RECORD DRAWING STATEMENT: 10/29/25