November 6, 2015
Wes Lemarque
City of Fort Collins
700 Wood Street
Fort Collins, CO
Re: Feeders Supply Record Drawings
Mr. Lemarque:
City of Ft. Collin roved Plans
Approved By
Date 1Z-II-16
s
;2-u-ice wu-
This letter is to serve as an overall site certification for the Feeder Supply site
improvements and the multi -story residential building. The restaurant building
improvements and expansions are not included in this certification. All information
provided in this letter and on the record drawing plans you have received is based on a
several field surveys completed by Washburn Land Surveying on August 12, September
22 and October 19, 2015.
The LID swale on the northwest side of the building was constructed within construction
tolerances of the design plans elevations and will function as intended. Photos of the
construction of the LID swale are included at the end of this letter. All storm on site is
private and elevations were verified with the Washburn surveys. The permeable pavers
were installed on site and photos of the installation process are also provided at the end of
this letter.
The finished floor elevations of the lowest floor of the building along Willow were
constructed at or within 0.05' of the design elevation. The garage elevations and all curb
and gutter (private) on site were constructed within acceptable construction tolerances.
The south portion of the driveway (nearest Linden) has not been constructed and will be
completed with the restaurant expansion. All of the private drive that is required for
emergency access has been constructed. There appears to be (based on the field survey)
sufficient slope away from the building to allow runoff to adequately flow in the direction
as intended by the original design plans.
If you have and questions,or need additional information for this certification, please call
me.
Sincerely,
Patricia Kroetch, P.E.
I i;_III e 1 LI ID Shale: I.%c:n ation
Figure 2 I.ID Swale: Subdrain Installation
No Text
Figure 5 LID Swale: Inflow Pipe Installation
Fi--urc 6 LID Shale: \'iee from Willmc
Figure 7 LID Swale: View from Private Drive
Figure 9: Subgrade Preparation for Pacers
Figure 10: Liner & Drainage Course Installation for Pavers
i;!ure 12: Completed Drainage Couece
Figure 13: Leveling Course Installation
Figure 13: Payer Installation
Fort��ins
COMMERCIAL, MULTI -FAMILY AND SUBDIVISION
CERTIFICATION FORM & CHECKLIST
(Overall Site Drainage)
Feeders Supply -
(Project Name)
11/6/15
(Date)
(For Commercial or Multi -family, please list any applicable building permit numbers)
Please fill in all applicable items in this Certification Form for Commercial, Multi -Family and Overall Single Family
sites. A copy of the approved grading plan must be submitted with the as -built grading plan. (It is preferred to
have the as -built elevations written in red next to the approved elevations)
Use "OK" for items checked or actual numbers for items verified/surveyed in the field.
Use "N/A" for items that are not applicable to the site that is being certified.
Please provide an As -Built Redlined or Mylar drawing showing the following:
A. Detention, Drainage Facilities, and Common Open Spaces
1. Pond Certification No detention or water quality pond on this site.
— Provide Topographic Records (grading certification with as —built spot elevations) and Volume
Verification Calculations. Show both the proposed and as -built elevations on the same plan sheet.
— Provide Pond Cross -Sections and Spot Elevations (especially @ Pond Embankment and Pond Flow Line)
— Positive Fall to Pan (if applicable)
— General Pond Grading including all Side -Slopes
— Invert Elevation
— Forebay Construction and Elevation
— Spillway Weir (Location, Elevation, Height, Opening Width)
— Placement and size of riprap or alternative permanent erosion control measures
— Orifice Plate and/or Water Quality Outlet Structure Installation
— Water Quality Capture Volume (Volume Required, Volume Provided and Water Surface Elevation)
— Berm and Embankment Compaction Level
— Subsurface Media for Water Quality Ponds and Swales
12/12/2014 Revision —Page 1 of
2. Swales No swales on this site
— Location (are they within easement?)
— Dimension and Cross -Section Verification
— Longitudinal Slopes and Side -Slopes
— Spot Elevations
— Permanent Erosion Control Measures (drop structures, riprap, lining)
— Tie-in to Storm Lines, Pans, Curbs, or other appurtenances
— Required Minimum Freeboard, Provided Freeboard
— Landscaping Infringement on Flow Line?
3. Pioes
X Size and Type
X Slopes (As -Built and comparison to 0.4% Minimum)
— Pipe Capacity Calculations (if slopes are significantly altered from design)
X Invert Elevations
X Installation and Backfill
X Cover
Not Verified Encasement and Clearance from other nearby utility lines
Not VerifiedJointsType and construction
4. Concrete Pan Channels
X
— Size
X Slope
X Cross Section
Not Verified Thickness
X Elevations
Fort Collins
12/12/2014 Revision — Page 2 of 5
5. Inlets
X Size and Type
X Size of Opening (or name of Standard Detail used)
Grate Elevation
X Invert Elevation
X Box Size
6. Street Cross -Pans
X_
Size
A
Type
X
Grade
X
Elevations
—
Cross -Sectional Depth
—
Tie-in to Curb and Gutter
7. Culverts No Culverts on site
— Size
— Type
— Invert Elevations
— Headwalls or Wing Walls
8. Sub -Drains
X
Size
X Type (Perforated/Solid)
X Cover
2L Backfill
FCfty of
ort Collins
12/12/2014 Revision — Page 3 of 5
City of
Fort Collins
X Geo-Textile Liners
— Clean -Outs
9. Curb cuts There are no curb cuts on this site
— Size
— Tie-in to Swale, Pipe or other appurtenances
10. Common open Spaces There are no common open spaces on this site
— Overall grading contours of open spaces
— Spot elevations adjacent to private lots (property corners)
B. Low Impact Development (LID) Certification
1. LID Technique Specific Checklists (see attached)
X Permeable Interlocking Concrete Pavers (complete if technique utilized on site)
A Bioretention Cells (complete if technique utilized on site)
C. Grading Certification
1. Certification of Grade Elevations
x Minimum Opening Elevations Verified finished floor elevations
— Top of Foundation Elevations
11�4 Comparison to 100-year Water Service Elevations
ra Comparison to Freeboard Elevations and Base Floodplain Elevations— BFE
2. Verification of Site Grading
X Engineer to evaluate site grading compliance with the approved grading plan.
X As -built elevations are to be redlined onto the approved grading plan sheet showing the as -built spot
elevations next to the design spot elevations so compliance can be verified and documented.
12/12/2014 Revision — Page 4 of 5
City
FortS
D. Post -Construction Site Cleanup
1. Permanent BMP Measures
X Construction Debris Clean -Up (In particular debris affecting the drainage)
X Smoothing of Ruts in all Construction Areas
X Reseeding of all Areas Affected by Construction Activities (Usually enforced by the City's Erosion
Control Inspector but the engineer certifying the site needs to notify the contractor if areas are not
seeded) Only applies to LID Swale, all other areas paved
E. Statement of Comollance
This certification is signed and stamped and by signing this form the Engineer(s) attests that they have
inspected the site and to the best of their knowledge the as -built conditions of the drainage facilities are as
described in the above form and in the As -Built plans enclosed.
Failure to properly disclose all known information could result in the rejection of this certification and
prevent the release of any and all Stormwater Utility permit holds on Building Permits and/or Certificates of
Occupancy within this development.
F. Signature and Stamp by a Colorado Registered Professional Engineer
Engineers contact information:
Patricia Kroetch
(Name)
tricia@northstardes ign i nc.com
(Email address)
970-686-6939
(Telephone number)
North Star Design, Inc.
(Company Name)
700 Automation Drive, Unit 1, Windsor, CO
(Company Address)
PE STAMP
12/12/2014 Revision — Page 5 of 5
Foty of
rtes �r
Construction Inspection Checklist for Permeable Interlocking Concrete Pavers
Item/Activity Yes I No I N/A Documentation/Submittal Requirements
Excavation
Post -excavation infiltration rates arc consistent with
design infiltration capacity (for" or partial
infiltration" designs)
x
Irapermeable Liner
Impermeable liner meets design specifications
x
Lmliernicable liner attached to concrete perimeter wall
X
Impermeable liner is not exposed
x
Any Penetrations of the impermeable liner have been
sealed and checked for water -tightness.
x
Concrete
Cut -Off Wall
Meets Specifications for:
X
- Dimensions
- Reinforcement
- Footings
Underdrain
System
Underdrain pipe is per design secifcations
x
At least one cleanout is provided per underdrain lateral
x
Cleanout pipe is not perforated
Cleanouts covers are installed and watertight
Underdrain is NOT wrapped in geotextile fabric
x
Underdrain orifice plate installed
at outlet structure
x
Underdrain integrity tested after backfilling using TV
and/or water test
X
Aggregate
Base coarse e.. #2/4 has 90% fractured faces
X
Beddingcoarse e.. #89 is thorou hl washed
X
Subbase materials are installed and compacted according
to manufacturer specifications
I x
Protection During Construction
12/122014 Revision - Page I of 2
PICP area is protected from construction site sediment,
including runoff from the upstream catchment and FX
construction equipment traffic.
Close Out
Upstream catchment is stabilized prior to diverting runoff
into PICP system _ x
Of
Crcy' �
I V122014R.vm.n- Page 2 of2
C rt Collins
Construction Inspection Checklist forte LID Swale
Item/Activity Yes I No I N/A Documentation/Submittal Requirements
Excavation
Heavy equipment did not travel over bioretention cell
during excavation
X
Bottom of cell was "ripped" after excavation
x
I
Photograph before/after "ripping".
Bottom of cell is flat and level
X
Photograph
Excavated area is protected/surrounded by
sediment/runoff control BMPs during construction
X
I
I
Photograph
Inlet
Inlet invert elevation is at least 3 inches above
containment wall/berm
X
Measure/record distance between inlet and top of
containment walllberm
Upstream catchment drains to inlet
x
Foreba
Forebay is installed according to esign specifications
X
Forebay has flat. concrete bottom
Outlet Structure/Overflow
Outlet structure/overflow elevation is confirmed
X
Measure/record distance from overflow to top of
media filter
Im ermeable Liner
Impermeable Iincr meets design specifications
X
Impermeable liner attached to concrete perimeter wall
X
Impermeable liner is not exposed
X
UnJerdrain
System
Underdrain pipe is per design specifications
At least one cleanout is provided per underdrain lateral
X
Cleanout pipe is not perforated
Cleanouts covers are installed and watertight
Underdrrun is NOT wrapped in eotextile fabric
X
Undcrdrain orifice late installed at outlet structure
X
Underdrain integrity tested after backfilling using TV
and/or water test
X
12/12/2014 Revision - Page 1 or2
Filter Media
Filter media composition is per design specifications
X
Filter media was "machine mixed" by supplier prior to
delivery
X
Filtcr media installed Flat and level
X
Other Structural
Components
Containment wall/berm is continuous and level X
Landscaping
Final landscaping does NOT include sod
x
Final landscaping (wood/rock mulch) is Flat and level
x
Vegetation is planted according to Landscape design
specifications ecifications
X
Verify that weed barrier is not installed
X
Temporary irrigation installed
X
If N/A, then verify that permanent irrigation is
installed to establish/maintain vegetation
Close Out
Upstream catchment stabilized prior to diverting runoff
into bioretention cell I
X
12/12120W Revision -Page 2 of2
RECORD DRA W/lVG
\ \ \ \ n rMa<a F.
�E9EN0 - Mzcan KvxYN. j
,
A.
sxu
o Ea EttE w AVNAu MwYrn r EamNFs m
zo zo to .o pa Y
\ \ E°C LM V RNp6R 11 Mtl'PdC S CattVFs � m
rwwEax
vnw030 IxRGA NI®
,/ \ YSY r corvErz P.x
`\ ♦ \`,\ EpSnryt FOR J `` \ Enmlc n Mixn¢ vmc
� s
y g'b'Ybs4 <mcPMM
A.E PEXNEAME PXwn', Y
WSiA AS H.A,aID
LID DETAIL
scue: "-to'
RECORD DRAWING NOTES -
`[/\//\,,•`�Wa,wwi \ \ E .Y[VO G, WONRWPTII[tD BI f(flB/dl' m
sNiEmv ae/?/iS 9/r9/u.ao rryl9As. AfAW
\ SrA9 rc3vE NC AC!➢IS M,B�/1]'fOt HF
AEpRI(Y? 9R MWNIAm
n� \ 1 .4NA mIE6Y NROfI/p1'6ALW N/IK.CS
\ aevaNf .w+PoK9 aa+s rae 9[nnucrsm.fu ,N �
`' t� maw ¢3YiY NrmYANN 5 $
\® o
wi \ TOP a s*EPs= esua, or. v S r S-
\. s,EPs- .. BOTTOM OF SR =V.es 2
$9.X9 67, LK
\ N Y m
�'e •\ Y \' \ Y \ \ V
vi o o`
olvi
`• \ SEKIX>im M p S*Sps MM \\ \6 ` i ` fA ` NXXPC/➢ Mwo \
NXvon.NLs � ♦ ro RMAW
` ARP pXWCKR \' O 9E.•\i mR ``,`♦ E_
\ \
\ ♦ ` W
s/ s /J it
FnS,WE W�Fi � , ` fL Z
\ wiOEPEX'.AiN
\\ M3G ,0 Ntl1 OMI.P ' ••r'' y �% MwEEni�G ry
Z Z �yOR
tab
Z
kPjV/ ^LU
Y/ Mn faNOQT � Q
�x\ ♦ j � C7
AS
i
a _
cwcuif e ? _ ¢YsvcMAPEk PUN,�I' / SHEET
P,V. CONiMi MYNEEWNY i � / L.L
CALL NOI1FlCA O t\ / Nrnm NNv m ! r
CENTEMRR M aF COLORADO _ /
1-800-922-1987 %,'i ° o�6p
Cy E-BUSMf55 YAK W IpVAX(E �' 4 OF 11
EfPYPE .a we Y0.AYC YN fxc.Avnn: 'q'! — rxMY\c ♦ J /
IM ,NF Y.VdYIY w IMOERpiplNp (� jj SYISnNE PAPpNG ' /
fWM ununf2 .' `J iXu sTXRs �/ Job NY.