Loading...
HomeMy WebLinkAboutLot Certifications - 09/20/2001 (7)11 /MIRES ASSOCIATES September 7, 2001 Mr. Jay Barber City of Fort Collins Stormwater Utility 70G Wood Street Fort Collins, Colorado 80521 Re: Drainage Certification for!B`uildin`g D; Lot 6A;=Collndale Business"Park Third -Filing Dear Jay, { Qxr—�v/y/a"Mail 'Gfjac�, ✓ We recently surveyed Building D, Lot 6A, Collindale Business Park Third Filing to verify whether the grading met the intent of the approved grading and drainage plan.. Spot elevations -were checked at pertinent locations and compared to the grading plan. The enclosed drawing shows these as -built elevations. In general, the lot and building meet the requirements of the grading and drainage plan and there is positive drainage away from the building on all sides. Survey points were taken - pertinent locations to verify the slope away from the building. The finished floor elevation id 4960.28, which is 0.08 feet higher than the design elevation. The west side of the building slopes to the northwest; the north side of the building slopes to the northeast; the south side of the building slopes to the southeast; and the east side of the building slopes to the northeast. It is my recommendation that the Certificate of Occupancy for this property be released since the Contractor graded the lot to meet design drainage patterns. If you have any questions, please call. Sincerely, Owen Ayres & Christopher Project Eng CLD:sp Enclosure Owen Ayres & Associates, Inc. Engineers/Scientists/Surveyors 3665 JFK Parkway, Building 2, Suite 200, P.O. Box 270460, Fort Collins, CO 80527 (970) 223-5556, Denver Metro (303) 572-1866, FAX (970) 223-5578 Printed on recycled paper - BARB9C.DOC 32-0495.00 O h� 001 00• 0 OOh DSO Q co N O LL '... t0 `^ O • v �� n Y z co co Z LL _ H I m LL 000 0 tr°j ro0 � �� h