HomeMy WebLinkAboutLot Certifications - 11/20/2005LOT GRADING CERTIFICATION
DATE: 14/ 1 5—
ADDRESS: �iOif7` �. `-��i1�r� / ile" o�-I
LOT: BLOCK:
SUBDIVISION: The, Gr>✓ens Co,";hAle,
This certification is signed and stamped by a professional engineer registered in the State of Colorado.
By signing this certification the engineer attests that to the best of his (her) knowledge the surveyed
grading as shown in the enclosed certification is in general compliance with the approved grading plan
for this lot and subdivision as shown on the approved utility plans, dated 111&/Q0
Landmark Engineering Ltd. (970) 667-6286
Engineering/Surveying Firm Name Phone
3521 W. Eisenhower Boulevard
Firm Address
Loveland Colorado 80537
City State Zip Code
Brian J. Hailey
Print Name of Engineer/Surveyor
Signature of Engi
SEAL
r
J .
37105
0NAi EN
PLOT PLAN
LOT 21, THE GREENS OF COLLINDALE P.U.D. FIRST REPLAT
PRIVATE DRIVE, FT. COLLINS, COLORADO
XXXX.XX = LOT CORNER ELEVATION PER GRADING PLAN
XXX.XX X = EXTERIOR GRADE ELEVATION PER GRADING PLAN
T.O.F. = PROPOSED TOP OF FOUNDATION ELEVATION
NOTE: FINISHED GRADE AT FOUNDATION SHALL BE 8" LOWER THAN T.O.F.
J
LOT 21 Jr4 k�_ � v
5,656 SQ. FT.
w
M^
O -.. SIDEWAIdC . r N� .
�9'4.4'1 b'< W 00. aam Y
. tea' _
0, IQI Q
O 13' UTILITY d� '.CON�RE-It a II a, p .
Z DRAINAGE 1� DRIVEWAY, 4 m O
EASEMENT
. S 89'44'11" E 2�FRONT SETBACK 10.00'N6
8.00' $ 10.0 7
''n, 14.00' Room
f,
9� I I t- 0 o I 4g8yB9
SO \\
k O p
00 I I 5.50' GARAGE I
�
�I j�I I Ill
6 I I L_ _ I I W
W W
N III �IC2W
_ .I� I m,
YI
HOLDEN —FLAT I m�
.y a ICI98
TY�BDRA N�El > Iwl
l(n 0 hI
f�l r�l
o�
I •. a
I
IIIjn.sx I�LI
a COVERED O' I I V 3
1J53' 1 0°• PATIO a 13,63'1 7• -
10.25'
to ,�� - 15' REAR SETBACK II
a+ �! n
15' DRAINAGE do UTILITY °' �I
O O1 EASEMENT u olm
53'- 39.50' � 6.9T
a9e� ae S 89'44 11 E 58.00 49B0.45
NOTES: -
1. THIS PLOT PLAN IS BASED ON INFORMATION PROVIDED BY THE OWNER/CONTRACTOR. THE
OWNER/CONTRACTOR SHALL VERIFY ALL LOT DIMENSIONS, SETBACK INFORMATION, EASEMENT WIDTHS.
GRADING ELEVATIONS AND THE PROXIMITY TO EXISTING STRUCTURES WITH THE GOVERNING AUTHORITY AND
OR COVENANTS.
2. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO EXTERIOR FOUNDATION
CORNERS.
3. THE CONTRACTOR SHALL VERIFY ELEVATIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY VARIATION
TO THIS PLAN SHALL BE REPORTED TO LANDMARK ENGINEERING LTD. IMMEDIATELY.
4. THE CONTRACTOR SHALL NOT ENCROACH ON ADJACENT PROPERTY WITHOUT PERMISSION FROM THE
AFFECTED PROPERTY OWNERS.
5. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS: A MINIMUM SLOPE OF "
5x IS REQUIRED FOR THE FIRST 10 FEET AND THEN A MINIMUM SLOPE OF 2% IS REQUIRED THEREAFTER.
REVISED: 9 7 04
TITLE: PLOT PLAN, L21, THE GREENS AT COLLINDALE
@ GION@03D80t a Led
ENGINEERS/ARCHITECTS/PLANNERS/SURVEYORS CLIENT: ACE QUALITY HOMES ACEQUA-4E4K-03-623
3521 Wes} Eisenhower Blvd., Loveland, Colorado 80537
(970) 667-6286 Denver (303) 629-7124.Fox (970) 667-629B SCALE: 1" = 20' DATE: JUNE 8, 2004