HomeMy WebLinkAboutLot Certifications - 11/20/2007 (13)Cil-v. of Fart C933..ills
I:if': 'i l,:l b �t.i ';�i ii'-: i'i i.�:it • ]l':1 `.i •:. ":'y'...... .b .....
CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and
City Land Use Code § 3.2.2 (e)
Date: July 3.2006
Permit Application No. B0407286
Address: 4014 South Lemay Avenue. Unit #6
Lot: 6 Block:
Subdivision: The Greens at Collindale P.U.D.. First Replat
I,(Print)_ Wayne G Thompson , a Colorado registered professional engineer, verify that the above
referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under
my direct supervision, and verify construction of all stormwater facilities and grading is complete, and
the elevations and drainage patterns shown on the attached drawing(s) which were developed from a
survey performed on (Date) June 12, 2006 , accurately and truly depict the elevations and drainage
patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property. (information attached). SEE NOTE.
Q,'�`fhe elevations and drainage patterns of the lot/site as measured are in general conformance
with the City approved drainage plan with exceptions (information attached). In my professional
judgment the elevations and grading of the lot as constructed is functionally
allow for stormwater drainage consistent with the approved drainage plan.
SEE NOTE. `-`'-
> v .' r�yF
35177
stamp)
(address of signing party)
vG �THo Tc<;
i:t,5 zs
NOTE:
A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design and as -
built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
information/explanation of discrepancies, etc. to:
Fort Collins Utilities (970) 221-6700
700 Wood Street
Fort Collins, CO 80821
Rev. 1/1/a6 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property
ia� E 47--3/ i 1
®Ud.aJla l � Led
ENGINEERS/ARCHITECTS/PLANNERS/SURVEYORS
3521 West Eisenhower Blvd., Loveland, Colorado 80537
(970) 667-6286 Denver (303) 629-7124 Fax (970) 667-6298
`OT PLAN
LOT 6, THE GREENS OF COLLINDALE P.U.D. FIRST REPLAT
PRIVATE DRIVE, FT. COLLINS, COLORADO
XXXX.XX = LOT CORNER ELEVATION PER GRADING PLAN
XXXXX X = EXTERIOR GRADE ELEVATION PER GRADING PLAN
F.F. = FINISHED FLOOR ELEVATION
NOTE: FINISHED GRADE AT FOUNDATION SHALL BE 8" LOWER THAN T.O.F.
LOT 6
5,828
SO. FT.
sw.f e t`✓
ip e
1.170
:d.Lw
s --�
-i
e
,Hi
y 3' DRAINAG UTILITY EASEMENT
SS.T9 st•Id aH-85.00'0' e7•osLr)
"90*00'00"
32.54 �g
—_
21.38 10.06 _ C
o
> 1i
2 �4�
Cd
5 SIOE SETBACK �S[1� CBS T)'11.38
�6
vi
gS/� 10.06 �I
Wt1
XLOT
N.62
�1:0
0
as.z Y \
\�
O
I fl
�ZI I cm 8S.47 24.91 $f. 7:
p
08 0'1
g i. 4 G
?C
z
F� I u$
Zx
� (n
< Zi
00
Q
Wy
0
8.00'
HOLDEN FLAT ROOF
W
��W ll
co 00
y
�,
0
N C VERED ,�
MIN. T.O.F. = 4986.26
a
'
I ORCH
TYPE '8- DRAINAGE
11.96
6.79'--1
ZJW
� ..
<.20.0T I ` � <
o�
4.00 Y
U
a � 0
2.00' 4c
nl
,�
bid<
p
4? I •. ao
W
/
0
C_
22.79'
I
24.25'
m z
O� w
p
07 _
o'y.7� 0
T 4
84.E1
12.$3' 10.06
I[j X
k
_
$�S16E SETBACK—_
_
00
r,
15.06'
59.8T
10 O6'
f0'��
6W`
N 90'00'00" E
3 DRAINAGE k UTILITY EASEMENT_
85.00112's3
0a a°H.H7 oY.11
,4�1.11 a:.•�t!��. Y
—'7
AI7TE 1:5w4c RZ -e'Ad-605
AAI,N s0&Vf YID c,J .xI).vE Z/ Zak.
NOTES
1. THIS PLOT PLAN IS BASED ON INFORMATION PROVIOED.BY THE OWNER/CONTRACTOR. THE
OWNER/CONTRACTOR SHALL VERIFY ALL LOT DIMENSIONS, SETBACK INFORMATION, EASEMENT WIDTHS,
GRADING ELEVATIONS AND THE PROXIMITY TO EXISTING STRUCTURES WITH THE GOVERNING AUTHORITY AND
OR COVENANTS.
2. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO EXTERIOR FOUNDATION
CORNERS.
3. THE CONTRACTOR SHALL VERIFY ELEVATIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY VARIATION
TO THIS PLAN SHALL BE REPORTED TO LANDMARK ENGINEERING LTD. IMMEDIATELY.
4. THE CONTRACTOR SHALL NOT ENCROACH ON ADJACENT PROPERTY WITHOUT PERMISSION FROM THE
AFFECTED PROPERTY OWNERS.
5. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS: A MINIMUM SLOPE OF
5% IS REQUIRED FOR THE FIRST 10 FEET AND THEN A MINIMUM SLOPE OF 2R IS REQUIRED THEREAFTER.
REVISED: 11 /09/0,
PLOT PLAN, L6, THE GREENS AT COLLINDALE
ENT:
ACE
QUALITY
HOMES
ACEQUA-4E8J-03-623
ALE:
1"
= 20,
DATE:
JULY 14, 2004
Nj
I
00! 00 OQ�
LA
:rA
kx�
In
kA
ical oo�: 00' 613 oo c)Q.
co
64 L")
lid
:101
rr\
-z- (,J,%
IJ)
fiv
ri
P',J rA