Loading...
HomeMy WebLinkAboutLot Certifications - 11/20/2007 (9)Utilities electric a stormwater • wastewater . water CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: August 17, 2006 Permit Application No. B0407283 Address: 4014 South Lemav Avenue, Unit #2 Lot: Block: Subdivision: The Greens at Collindale P.U.D., First Replat (,(Print) Wayne G Thompson , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or someone under my direct supervision, and verify construction of all stormwater facilities and grading is complete, and the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date) August 1, 2006 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for sto rainage consistent with the approved drainage plan. SEEN P,O,,.REC•<•., ST TM �' Z •� Zt 35177 By: (signature, PE stamp) 3521 West Eisenhower Blvd, Loveland, Colorado (address of signing g party) nin a NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lottsite showing the approved design and as - built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written infomrationlexplanation of discrepancies, etc. to: Fort Collins Utilities (870) 221-6700 700 Wood Street Fort Collins, CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property Rev. 1H/n6 , Land.mar �� Engineering August 17, 2006 Project No. ACEQUA-4EQ-03-328 Re: Lot 2, The Greens at Collindale, Fort Collins 4014 South Lemay Avenue, Unit #2 Permit No. B0407283 To Whom It May Concern: The grading along the north lot line of this house is approximately 1% from the front of the lot to the rear. This drainage is different from the original plan because the highpoint along the side lot line was removed. Since the adjacent house is complete and a window well exists near the proposed highpoint, the enforcement of that highpoint would result in a drainage condition where the water is directed toward the window well. Therefore, we agreed with the decision to drain toward the rear of the lot and have thus approved the grading for this lot. Sincerely Landmark Wayne Thompson Colorado P.E. 35177 ��p REG�SQ G. THO , 3 177 SOT PLAN LOT 2, THE GREENS OF COLLINDALE P.U.D. FIRST REPLAT PRIVATE DRIVE, FT. COLLINS, COLORADO XXXX.XX = LOT CORNER ELEVATION PER GRADING PLAN XXX.XX X = EXTERIOR GRADE ELEVATION PER GRADING PLAN F.F. = FINISHED FLOOR ELEVATION NOTE: FINISHED GRADE AT FOUNDATION SHALL BE 8" LOWER THAN T.O.F. LOT 2 6,652 SO. FT. gr4d, )uCV �fr �o(. u (� Z F A = 15'51'18" R = 125.00' T = 17.41' L = 34.59' low,pY41�Y�I�� NOTES � Cf,GT IG Uf r.0 fla 1. THIS PLOT PLAN IS BASED ON INFORMATION PROVIDED BY THE OWNER/CONTRACTOR. THE OWNER/CONTRACTOR SHALL VERIFY ALL LOT DIMENSIONS, SETBACK INFORMATION, EASEMENT MOTHS, GRADING ELEVATIONS AND THE PROXIMITY TO EXISTING STRUCTURES WITH THE GOVERNING AUTHORITY AND OR COVENANTS. 2. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO EXTERIOR FOUNDATION CORNERS. 3. THE CONTRACTOR SHALL VERIFY ELEVATIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY VARIATION TO THIS PLAN SHALL BE REPORTED TO LANDMARK ENGINEERING LTD. IMMEDIATELY. 4. THE CONTRACTOR SHALL NOT ENCROACH ON ADJACENT PROPERTY WITHOUT PERMISSION FROM THE AFFECTED PROPERTY OWNERS. 5. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS: A MINIMUM SLOPE OF 5'% IS REQUIRED FOR THE FIRST 10 FEET AND THEN A MINIMUM SLOPE OF 2% IS REQUIRED THEREAFTER, Ltt ENGINEERS/ARCHITECTS/PLANNERS/SURVEYORS 3521 West Eisenhower Blvd., Loveland, Colorado 80537 (970) 667-6286 Denver (303) 629-7124 Fax (970) 667-6298 REVISED: 11 /09/0, TLE: PLOT PLAN, L2, THE GREENS AT COLLINDALE CLIENT: ACE QUALITY HOMESJACEQUA-4E4J-03--623 1" = 20' 1 DATE: JULY 14, 2004