HomeMy WebLinkAboutLot Certifications - 07/11/2013 (3)GI'tj/ f Utilities
electric stormwater. wastewater . water
700 Wood St.
Fort'Colli.hs'''.POBox ins,
Fort Collins, CO 80522
910.221.6700
970.221.6619 fax - 970.224.6003 TDD
utilities&CgoKcom . fcgov.00m/utiiities
CERTIFICATION OF LOT GRADING
Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e)
Date:., - _ July 11,_2013
-- — -= LOT UNIT RESIDENCE GARAGE
Permit Application No. twelve (12) permit Vs, see table to right 19 19 B1206378 ' . 61206435 .
Address: 3827 Precision _Drive, Units 19-24 20 20 B1206389 B1206442.
- - -- 21 21 B1206385 B1206443
Lot 19-24 Block: N.A. 22 22 -.B120638'6 B1206444
Subdivision:. -. _ Brookfield_ 23 23 B12063-M$O. B12064.45
24 24 B1206374 B1206436
I,(PMO- Nicholas W; Haws - _ - , a Colorado registered professional. engineer, verify that the
above referenced, property in the City of' Fort Collins., Colorado, has been inspected by me or an appropriately
qualified professional .under my direct superdision,. and verify that construction of all stormwater facilities and grading
is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed
from a survey performed on (Date):. July_ 3;-_2013 _ _ , accurately and truly depict the elevations and
drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
❑ The elevations and drainage patterns of the lottsite are in substantial conformance with the City approved
drainage and grading plan for the property (information attached).. SEE NOTE.
The elevations and drainage-pattems of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the tottsite as constructed are functionally adequate and equivalent to the specifically approved
drainage plan, and will affect stormwater drainage on and off the lottsite in a. manner consistent with the
approved drainage plan. SEE NOTE.
p
NOTE �Q • Wl . tiS
Engineers certification is limited strictly to
conformance with the Approved Plan, and implies ?'
-nothing regarding the adequacy of the original V 3
design included therewith. Additionally, the
certification of conformance with the approved
Drainage Plan of Record is commensurate with the
level of detail provided with the original design "
drawing (attached hereto). F�
By
(signature, PE stamp) .
200 S. College - Ave., Suite 10 80524..
- (address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request fora Certificate of Occupancy for the lottsite,
including but not .limited to drawings of the loti'ste.showing the approved design and as -built surveyed elevations of all structures,
drainage and grading features (e.g., swales, retaining walls, lot corners), written Informationle_xplanation of discrepancies, and other
Information necessary to confirm the above certification to:
Fort Collins 11811t1ies (976) 221-6700
700 Wood Street
Fort Collins, CO. 80521
At Least -Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property
Rev. 2009
0
IMPROVEMENT LOCATION CERTIFICATE .
FOR
LANDMARK CONSTRUCTION
LEGAL DESCRIPTION: LOTS 19-24, BROOKFIELD,
CITY OF FORT COLLINS, LARIMER COUNTY, STATE OF COLORADO,
ADDRESS: 3827 PRECISION DRIVE, UNITS 19,24
��. � ` PRECISION DIVE y.
---- ---------- �— .
__ — ---=----------------------------- ------
---- -------------------
-----------.--
- S89"07131"E 144.00'
32.0D' 20.00' 20.00' 20.0020.00' Ir I32.00'
AWr
tsa' wu P2-STORY..p 6 zv .97
BA S STONE
w/BASEMENT
cc fV CRcm CO 03—
CD
_L -oi- $ -a3—, o �rF=r�—
zv
Z2 �
10
°r•,
'• ���� N 's I "`
'a t0�' G • 20.a za.Y • 9�C a3 rt
_ _
AVA — _
- O
'r 3.00
00
g
E'n ff
GARAGE -- GARAGE
o �j
N
a j JI �
' ` 2�;I °
r�:o°s_► Ij
1 S=Go, Pro r rr- I I .
q
26.00' 23.00' 23.00' I 23.00' 23.60'
NB9°0T31"W 144.00'
LOT' 19 O T 20 LOT 21 LOT 22 LOT M LOT 2g
NOTE:
BUILDER AND HOMEOWNERS SHALL KEEP
SIDEWALK CULVERTS CLEAN AND FREE FROM 20 10 0 Y0
OBSTRUCTIONS. OPEN DRAINING CONDITION LEGEND
'SHALL BE MAINTAINED IN PERPETUITY. 1•._ Y0' WINDOW WELL
1 HEREBY CERTIFY THAT TIC SURVEY WAS PREPARED FOR LANDMARK CONSTRUCTION AND THAT IT IS NOT A LAND SURVEY
PLAT OR WROVEYMENrSURVEY PLAT. AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE BU40MG.
V
OR OTHER FUTURE IMPROVEMENT (DIES. I FURTHER CERnFYTHAT BIPROVflgNLS ON THE ABOVE DESCRIBED PARCEL ON
THISCATS: MARCH 0. 2012 EXCEPT UTILITY CONNECTIONS ARE ENTIRELYWTTHON THE BOUNDARIES OP THE PARCEL. EXCEPT
PR MBES BY BMROVEMEN S ON ANYADJO NINE
O RT
••
AS SHOWN. THAT THERE ARE NO ENCROACBABRS UPON THE DESCRIBED
PRE]WBES. EXCEPT AS INDICATED AND TWITTMERE ONO APPARENT EVU ENCE OR SIGN OF ANY EASEMENT CROSSING OR
SUROEINNG ANY PART OF SAID PARCEL. EkCEPTAS NOTED.
:Ry 3707 Z; _
NOTICE:
•••.� f\
`. � • :
AOCQRDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN
THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVEN. MAY ANY
.ACTION SASED UPON ANY DEFECT IN THE SURVEY BE COMMENCED MORE THAN TEN YEARS AFTER THE
.DATE OF THE CERTIFICATION SHOWN HEREON.
NOTICE: ALL. BEARINGS: DISTANCES. AND EASEMENTS ARE PER THE SUBDIVISION PLAT UNLESS OTHERWISE NOTED.
-
ERIC R. SMITH. .
COLORADO PIS. NO. 37W
LANDMARK CONSTRUCTION BROOKFIELD
NO. - REVISION _ BY -DATE
r NORTHERN
_
ENGINEERING
i - . _
xxscear w.s.s to s-ont woxtt<:» rn s>c at a:» — -
rm cr.•.:aa..m sxza ...+.ca..'e.ss� i ' PROJECT O N4003 .. .. DRAWN By, MAK DATE: 7$13
C-3 1912
�3)'i )U 1
---------------------------- —
' 1
—___-- —
dWQMM% LANE E
Y I 1 # d fit}�� si
1
gL ► ti , .
J.
r r Lae
^ _ g +a: s; Ijfit Ise'
m
m tiii+
co I I t;
I a � �{ !
i e BaiLa
a Ti+iiii" r
Will
n — z
VAYW
,
e � . MATCHUNE SEE'SHEET m
O BROOKFIELD .
0 -
- FINAL GRADING AND EROSION CONTROL PLAN ::s: