HomeMy WebLinkAboutSite Certifications - 09/19/1994Engineering Consultants
209 S. Me[drum
Fort Collins, Colorado 80521
303/482-5922
FAX: 303/482-6368
Mr. Glen Schlueter
Cityof Fort Collins
Stormwater Utility
235 Mathews
Fort Collins, CO 80522
Re:. a; Burns Ranch at Quail Ridge
Second Filing Drainage Certification
RBD Job No. 394-007
Dear Glen:
e:;1
v
September 19, 1994
KO> us
Please find enclosed sheet 9 of 12 of the Burns Ranch at Quail Ridge Second Filing Utility Plan.
The blue print, contains redlined elevations of the field as -built informationgathered on the storm
sewer system. The as -built slopes of the storm sewer system exceed the minimum designed pipe
slopes and thus the system is anticipated to function as intended.
The curb inlet erosion control gravel inlet filters have. been installed in accordance with the
Utility Plan requirements.
The drainage swale reshaping downstream of the storm sewer system has been regraded,
reseeded, erosion control blankets installed,. and thus now meets all of the requirements of the
design intent.
The roadside swale adjacent (parallel) to Overland Trail has been regraded, reseeded, erosion
control .bales installed, vegetation established, and thus now meets all of the requirements of the
original design.
In summary, the drainage components of this project have been installed in accordance with the
design intent and I hereby certify that the improvements installed should function in an
acceptable manner.
Please issue your departments approval of this project to the City of Fort Collins Building
Department so that additional building permits may be issued on this project. Thank you for
your time and consideration of this matter.
Sincerely,
RBD Inc.
Kevin W. Gingery, 7E.
Denver3031458-5526