HomeMy WebLinkAboutGrading Plans - 07/01/2025X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXX XX XX 100'-0" T.O. SHEATH 7' - 10" WI N D O W W E L L WI N D O W W E L L PROPOSED PATIO PROPOSED PORCH DN SETBACK 5' - 0" SETBACK 5' - 0" SE T B A C K 15 ' - 0 " SE T B A C K 5' - 0 " EXISTING GARAGE PROPERTY LINE ALLEY GAS METER HOSE BIB HOSE BIB ROOF LINE ABOVE EXISTING FENCE DS DS DS DS • SOILS ENGINEER SHALL REVIEW SOILS CONDITIONS DURING OPEN HOLE INSPECTION. STRUCTURAL ENGINEER TO VERIFY SOIL CONDITIONS MEET ASSUMED CONDITIONS FOR STRUCTURAL CALCULATIONS. • VERIFY LOCATIONS OF EXISTING UTILITIES BEFORE PROCEEDING WITH EXCAVATIONS. • ALL GRADING AND CONC. PAVING SHALL SLOPE AWAY FROM THE BUILDING. • IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN ADEQUATE DRAINAGE THROUGHOUT THE SITE DURING THE PROCESS OF EXCAVATION AND GRADING. THE GRADE SHALL BE MAINTAINED IN SUCH CONDITION THAT IT IS WELL DRAINED AT ALL TIMES. • ADJACENT STREETS AND PARKING AREA SHALL BE KEPT FREE OF MUD & DEBRIS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF MUD AND DEBRIS AT THE END OF EACH DAY. • THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS TO REMAIN FROM DAMAGE. DAMAGED ITEMS SHALL BE REPLACED, REPAIRED OR RESTORED BY CONTRACTOR AT NO COST TO THE OWNER. IF, IN THE OPINION OF THE CONTRACTOR, EXISTING IMPROVEMENTS TO REMAIN WILL BE DAMAGED OR REQUIRE REMOVAL TO ACCOMPLISH CONSTRUCTION, CONTRACTOR SHALL INCLUDE THE COST OF REPAIR OR REPLACEMENT IN BASE BID. • ALL IMPROVEMENTS ON PUBLIC PROPERTY SHALL CONFORM WITH THE LOCAL RULES, REGULATIONS AND ORDINANCES. GENERAL SITE NOTES: LIVING ROOM DINING KITCHEN PRIMARY BEDROOM BATH POWDER PORCH WINDOW WELL PATIO LOUNGE BEDROOM BEDROOM BATH UTILITY LAUNDRY WINDOW WELL WINDOW WELL IMPERVIOUS SURFACE AREA CALCULATION EXISTING PROPERTY PROPERTY AREA IMPERVIOUS AREA IMPERVIOUS AREA % PROPOSED ADDITION 5,600 SF 1,274 SF 23% 5,600 SF 1,905 SF 34% INCREASE IN IMPERVIOUS AREA 0 SF 631 SF 11% NOTE: THIS ARCHITECTURAL SITE PLAN IS FOR GENERAL ORIENTATION PURPOSES ONLY. SEE CIVIL AND LANDSCAPE DRAWINGS BY OTHERS FOR ADDITIONAL INFORMATION. 419 Canyon Ave Suite 200, Fort Collins, Colorado 80521 970.224.1191 | www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. CHECKED BY: DRAWN BY: COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE REVISIONS No.Description Date VAUGHT FRYE LARSON ARONSON TM JH, TM NOT FOR CONSTRUCTION FOR REFERENCE ONLY A R C H I T E C T U R E + I N T E R I O R S STRUCTURAL ENGINEER: PEN ENGINEERING, INC. (720) 347-0054 wthompson@pen-engineeringllc.com www.pen-engineeringllc.com CONTACT: WAYNE THOMPSON GENERAL CONTRACTOR: LAMAR VALLEY CRAFSTMAN 2620 BRUSH CREEK DRIVE FORT COLLINS, CO 80528 PHONE: (970) 690-8526 barry@lamarvalleycraftsman.com CONTACT: BARRY SCHRAM 5/ 3 0 / 2 0 2 5 5 : 1 5 : 3 6 P M 5/30/2025 5:15:36 PM C: \ U s e r s \ t a y l o r \ D o c u m e n t s \ H a m b r i g h t R e s i d e n c e - W O R KS H A R E _ t a y l o r 9 U 2 C 7 . r v t A0.1 ARCHITECTURAL SITE PLAN THE HAMBRIGHT RESIDENCE 508 EDWARDS ST FORT COLLINS, CO 80524 CONSTRUCTION SET 05-02-2025 2024-19 TRUE NORTH 1/8" = 1'-0"1 ARCHITECTURAL SITE PLAN 2 ISOMETRIC FLOOR PLAN - MAIN FLOOR 3 ISOMETRIC FLOOR PLAN - LOWER FLOOR CONSTRUCTION SET 05-20-2025 FINISHED AREA Name Area LOWER LEVEL ADDITION 216 SF LOWER LEVEL REMODEL 785 SF MAIN LEVEL ADDITION 216 SF MAIN LEVEL REMODEL 787 SF 2005 SF FLOOR AREA ANALYSIS (SQ FT): TOTAL ZONING INFO: 5,600 SF SITE AREA = 0.13 ACRES OLD TOWN DISTRICT - MEDIUM 05-20-2025 Crafts Resub Lot 13 Blk 11 B2504402 Grading/Stormwater Plan Accepted (Building Permit Released) Accepted by: Date: Dan Mogen 07/01/2025