Loading...
HomeMy WebLinkAboutGrading Plans - 06/23/2025TRI-PEAKS 306 E. Elizabeth St. • Fort Collins • Colorado • 80524 office (970) 232-9482 cthew@tri-peaks.com June 12, 2025 City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, CO 80521 Re: Drainage Memorandum 1616 S. Whitcomb Street Fort Collins, CO 80526 We are pleased to submit this letter to for the analysis of 1616 S. Whitcomb located in Fort Collins Colorado. In general this is a summary of the stormwater impacts associated with the proposed site improvements shown on the attached Site/Grading Plan. The 1616 S. Whitcomb Residence site (referred herein as “site”) is situated 300 feet south of Prospect Ave on the East side of S. Whitcomb Street. This site is also known as Lot 89 of the Arthur C. Shelly 3rd Subdivision. The planned improvements on the site consist of the demolition of the existing structure and construction of a new single-family residence utilizing the existing foundation with the addition/expansion of the residence placed over a crawlspace. Removals and additions to the concrete hard surfacing of sidewalks and patios to support the structure are shown as planned. The existing site is located in the Spring Creek Drainage Basin and is a 7200 square foot lot/parcel. The site drains via overland flow to the east and west with a “Type B” grading per the Fort Collins Stormwater Criteria Manual (FCSCM). The roofline of the existing structure similarly drained east and west split at the centerline peak of the residence. Drainage along the front of the site then flows north via the roadway infrastructure, and in the back of the site flows are directed south along an existing retaining wall through the back of adjacent lots. The proposed site improvements as shown in the Site/Grading Plan were found to increase the Overall Site Impervious area of the site by 792 square feet. The peak of the residence is proposed to be rotated shedding flows north/south with the proposed gutters intended to direct the majority of the proposed roof drainage to the front to the lot. An analysis to the back of the lot was performed and it would found to decrease the impervious area drained to the east by 92 square feet. Gutter direction and downspouts are shown on the Site/Grading Plan to direct flows as intended. Grading/Stormwater Plan Accepted (Building Permit Released) Accepted by: Date : Dan Mogen 06/23/2025 LOT 89, ARTHUR C SHEELY 3RD, FTC Permit B2501887 N 89°59'00" W 102.01' (M) N 0 0 ° 0 8 ' 2 5 " E 6 9 . 8 9 ' ( M ) N 89°55'26" W 102.63' (M) S 0 0 ° 2 2 ' 0 0 " E 7 0 . 0 0 ' ( R ) 31 5 . 0 0 ' ( R ) N 90°00'00" W 101.83' (R) N 90°00'00" W 102.28' (R) N 0 0 ° 0 0 ' 0 0 " W 7 0 . 0 0 ' ( R ) 52 . 0 ' 24.0' 52 . 0 ' 24.0' 10 . 6 ' 7. 3 ' 30.1' EXISTING RESIDENCE ON FOUNDATION TO BE REPLACED FF = 5020.4 1248 S.F. SO U T H W H I T C O M B S T R E E T 50 ' R I G H T O F W A Y ( P L A T ) 10' UTILITY EASEMENT (PLAT) WO O D F E N C E L I E S +/ - 1 . 3 ' N O R T H O F PA R C E L L I N E CH A I N L I N K F E N C E LI E S + / - 0 . 4 ' S O U T H OF P A R C E L L I N E CH A I N L I N K F E N C E LI E S + / - 0 . 6 ' S O U T H OF P A R C E L L I N E CH A I N L I N K F E N C E LI E S + / - 0 . 3 ' N O R T H OF P A R C E L L I N E CH A I N L I N K F E N C E LI E S + / - 0 . 3 ' N O R T H OF P A R C E L L I N E CONCRETE WALL WITH CHAIN LINK FENCE LIES +/- 1.2' EAST OF PARCEL LINE LOT 89 THE ARTHUR C. SHEELY THIRD SUBDIVISION RECEPTION NO. 686675 (1954) 12 . 5 ' 30.3' EXISTING CONC. DRIVE AND SIDEWALK 645 S.F. TO REMAIN/ BE REPLACED 30.2' 4. 0 ' EXISTING CONC. WALK AND STEPS TO BE REMOVED 121 S.F. PROPOSED ADDITION ON CRAWLSPACE FF TO MATCH 520 S.F. 13.0' 40 . 0 ' 13.0' PROPOSED CONC. PATIO @ FF ELEV. 325 S.F. EX.F.G.=5017.9 EX.F.G.=5017.2 EX.F.G.=5017.6 EX.F.G.=5017.9 EX.F.G.=5019.1 EX.F.G.=5019.1 EX.F.G.=5019.4 EX.F.G.=5019.4 21.0' 24 . 0 ' 12.0' 3.0' 5. 0 ' STEPS AS NEEDED 15 S.F. 30.2' 4. 0 ' PROPOSED WALK AND ENTRYWAY 121 S.F.4. 0 ' EX I S T I N G S I D E W A L K 68 S . F R E M O V A L 17 . 0 ' 4.0' 4. 0 ' 9.0' 20 . 0 ' EX I S T I N G S I D E W A L K AN D R O L L O V E R C U R B / G U T T E R 10 . 6 ' 35.0' 7. 4 ' 10 . 6 ' GUTTER PROPOSED PEAK EXISTING ROOF DRAINAGE REMOVED FROM BACK YARD 624 S.F. GUTTER GUTTER GUTTER GUTTER EX I S T I N G P E A K ADDITIONAL (HATCHED) DRAINAGE AREA TO BACK YARD (EAST) 532 S.F. DR A W N B Y : FI E L D D A T E : PR O J E C T N O . : CL I E N T : DW G . D A T E : S OF H E E T 30 6 E . E L I Z A B E T H S T R E E T FO R T C O L L I N S C O L O R A D O (9 7 0 ) 2 3 2 - 9 4 8 2 ct h e w @ t r i - p e a k s . c o m TR I - P E A K S L L C CL T W2 4 - 1 2 7 8- 1 3 - 2 0 2 4 2- 1 8 - 2 0 2 5 IS R A E L B R O N E R 1 1 BRONER SITE/GRADING PLAN , SITE INFO: LOT 89, ARTHUR C SHEELY 3RD, FTC 1616 SOUTH WHITCOMB STREET, FORT COLLINS, COLORADO 80526. OWNER: ISREAL BRONER ISBRONER@GMAIL.COM EXISTING IMPERVIOUS AREA: RESIDENCE:1,248 S.F. WALK/DRIVEWAY 834 S.F. TOTAL 2,082 S.F. PROPOSED IMPERVIOUS AREA: REPLACED RESIDENCE 1,248 S.F ADDITION 520 S.F. PATIO/STEPS 340 S.F WALK/DRIVEWAY/ENTRYWAY 766 S.F. TOTAL 2,874 S.F. NET IMPERVIOUS AREA: 792 S.F. SETBACKS: NORTH / SIDE: 5 FT. REAR / EAST SIDE: 15 FT. SOUTH / SIDE: 5 FT. FRONT / WEST SIDE: 20 FT. DS DS DS BACK YARD (EAST) IMPERVIOUS AREA: EXISTING ROOF REMOVAL 624 S.F ADDITIONAL IMP. AREA (HATCHED)532 S.F NET -92 S.F. Grading/Stormwater Plan Accepted (Building Permit Released) Accepted by: Date: Dan Mogen 06/23/2025 Permit B2501887