Loading...
HomeMy WebLinkAboutLot Certifications - 06/06/2014 (6)I City of F ort Collins CERTIFICATION OF LOT GRADING Utilities electric. stormwater. wastewater. water 700 Wood St PO Box 580 Fort Collins, CO 80522 970.221.6700 970 221.6619 fax . 970.224 6003 TOO utilitiesnafcgov Com . tcgovoorrvutilities Pursuant to City Code 26 6-544 and City Land Use Code S 3.2.2 (e) Date, June 6.2014 Permit Application No BP1306145 GO r �bcN Address 5709 Coppervein Street Lot 2 Block 2 Subdivision: Kechter Crossing Planned Land Division [,(Print) Steven M. Strickling , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins. Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date). June 2. 2014 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one)- ❑ The elevations and drainage patterns of the IoVsite are in substantial conformance with the City approved drainage and grading plan for the property (information attached) SEE NOTE p/The elevations and drainage patterns of the IoVsite as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the approved drainage plan. SEE NOTE. 10056 Brisbane Lane. Littleton. CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site. including but not limited to drawings of the IoVsite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners). written information/explanation of discrepancies, and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970) 221-6700 Rev 1.27,12 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property civas enaineerina June 6.2014 FORT COLLINS UTILITIES 700 Wood Street Fort Collins, Colorado 80521 Re. Lot 2, Block 2. Kechter Crossing Planned Land Division Certification of Lot Grading The elevations and drainage patterns for Lot 2. Block 2, Kechter Crossing Planned Land Division are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned Land Division with one minor exception. The high point locations in the rear yard are approximately 10 feet from the rear property line instead of on the rear property line as shown on the Final Grading Plan. This is because the rear property line elevations are approximately 0.4 feet to 0.9 feet lower than those shown on the Final Grading Plan, due to the elevations of the concrete pan in Outlot B, constructed as part of the subdivision drainage infrastructure improvements. Since Lot 2, Block 2 is a Type A draining lot, the high point elevations were located approximately 10 feet in from the rear property line in order to provide the minimum 2% slope in the side yard swales draining to the front yard. It is our professional opinion that this exception is not significant and will still allow for stormwater drainage to be consistent with the City approved Final Grading Plan. Sincerely, CIVAS E Steven I Principal 10056 Brisbane Lane - Littieton - CO -80130 teH 720-240-58M -fax 720-223-6092 IEOVE R ELEVATION AN SUrveyin% Inc. 6841 SOUTH YOSEM/TE STREET 1100 CENTENNIAL, CO 80112 NAGE CERTIFICATE NO. 14—K TIMBERLINE ROAD eaMNam u 4' CONCRETE PAN - u.0 70.0043.7 +3s s U.E. — ♦� �4".4� BEaM US N Q j 45.0 45.2 N 44.7 sx az 649 �I d Z 44, 2 44.3 '� i 8,408 SQFP p 5.3 1]x ALL_4 N♦5A ♦. 1-2ew b 44.1 +1 v1 45.5 95. es V ♦ 46.1 Zj 4 3 Tex m Z (DRANACE CERTIFICATION #S7O9 M1 N P,I,SSEO ON W-02-2014_) Y7 NE OF UIS 1 GLIHOUSE TOF=4946.78 ^� PROPOSEDFHOUSE ]J�x � 44. 6.0 215 N IN ORANAGE PATTERN ' In ESTA9L SHED YET.) I COVO aaza PORCH 3.6 x sno 4 R� 6y • 9% My CONC. DRIVE 44.5x 91 2.9 ` 432 VCANT. . N � ♦4.2N IS' U.E.43.B1N � �1 SI 425 =4 4 ' .. 24.5A 4.5' WALK - 6. B.M. 5.6' BEE/LAWN 'OP &1CN OF CURB LOW IINf COPPERVEIN STREET 53' R.O.W. PRO 0 SJI�QOR _9 '• � YAA 0 20 40 `.33.4 Q 11 SCALE 1"=20' PREPARED FOR: MERITAGE HOMES DA •'(' LOT 2, BLOCK 2, KECHTER CROSSING PLANNED LAND DIVISION. COUNTY OF LARIMER. STATE OF COLORADO; ALSO KNOWN AS: 5709 COPPER VEIN STREET. ELEVATION AND DRAINAGE CERTIFICATE II HEREBY CERTIFY THAT THE GRADING AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN. AND TO THE BEST OF MY KNOWLEDGE AND BELIEF, ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE MEASURED TO THE NEAREST 0.1 FEET. THERE IS SUBSTANTIAL POSITIVE SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND THE GRADING AND DRAINAGE PATTERNS SUBSTANTIALLY MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN, DATED 03-22-13 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WINO OR WATER OR OTHER FACTORS. DRAINAGE DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS, LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS SURVEY MAY NOT ACCURATELY DEPICT THE GRADING AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY. THIS DOCUMENT IS NOT AN IMPROVEMENT LOCATION CERDFIGTE OR WID SURY PUT, THE ABOVE STATEMENT WES NOT WARRANT THIS PROPERTY TO BE FREE FROM INSTANCES OF STANOINC OR SLOW CHURNING WATER ARMY FRO! THE FOUNDATION.