HomeMy WebLinkAboutLot Certifications - 02/13/2015Utilities City electric. stormwater. wastewater. water Of Fort oowoost PO Box 580 Collins Fort Collins, CO 60522 F 970.221.6700 970.221.6619619 fax . 970 224 6003 TOO utilitiesio2fcgoy.com . rcgovcotWutdities CERTIFICATION OF LOT GRADING Pursuant to City Code 2fi 6-544 and City Land Use Code § 3.2.2 (e) Date: January 12, 2015 �F= Permit Application No. B1402980 COrtGa��d z/��zvtS Address: 5715 Crossview Drive Lot: 1 Block: 10 _ Subdivision: Kechter Crossing Planned Land Division (,(Print) Steven M. Strickling , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): January 6. 2015 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. V The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off tea manner consistent with the approved drainage plan. SEE NOTE. tt I q� l�12�2w3;• By (signature,yPE stamp) 10056 Brisbane Lane. Littleton, CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, including but not limited to drawings of the IoUsite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written information/explanation of discrepancies, and other information necessary to confirm the above certification to: Fort Collins Utilities 700 wood street Fort Collins, CO 80521 (970) 221.6700 Rev 1127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property CIVAS engineering January 12, 2015 FORT COLLINS UTILITIES 700 Wood Street Fort Collins, Colorado 80521 Re: Lot 1, Block 10, Kechter Crossing Planned Land Division Certification of Lot Grading The elevations and drainage patterns for Lot 1, Block 10, Kechter Crossing Planned Land Division are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned Land Division, with one minor exception. A side yard swale was constructed in the westerly side yard. The side yard swale discharges into Common Area C at the northwest property corner and then flows to the west to a 15' diameter culvert under the sidewalk in Common Area C as shown on the approved Final Grading Plan. The approved Final Grading Plan does not indicate a side yard Swale, but instead indicates the side yard surface draining to the west and directly to a swale in Common Area C. This swale conveys flows to the north to the above mentioned 15" diameter culvert. Since Lot 1, Block 10 is indicated as a Type B draining lot, and since drainage from the side yard of Lot 1, Block 10 to the 15' diameter culvert is maintained, it is our professional opinion that this exception is not significant and will still allow for stormwater drainage to generally be consistent with the City approved Final Grading Plan. Sincerely, A Steven M. Principal 10056 Brisbane Lane • utneton • CO •80130 tel 720-240-5882 -tax 720-223-6092 Z v J Z< w -4 z 1jL Na -0 Z ' I N rn / N N J; f rr`I rf�r B10-L1 B10-L2 B B TF=4943.50 TF=4943.00 PAD=4942.0 PAD=4942.00 I i J• O to OD V A C.1 N zz r 0 G�—ImD�O m c/)DDDNmtnc/i—a�—,vD—+��fl1NDN m� mpmrmrmm2—xDz0�1 mmr mpprm�mmm?m�m� �mmr ppm p-,Z�OOCOZrr)—n �� c»xv Z DZ i z pzo > A> 0 DOK V)LnMmmO�-;Oz�vvpim OZM— (A1 z rn 0fnD�� ZCI+fC>>� Z=i m xmp� -IxDm mpi9rm0 <O20n D zm�pCrp-OUZ Z cn A�Z v-nM rnZz��osr" �m� �7zNo� iM;mo Cz�Z'D ��z n!leg, Inc. ..._ 6841 SOUTH YOSEMITE STREET #100 CENTENNIAL, CO 80112 41 ACcolwoll t \ . • j 1 / 3T . 88.6 r — T902 SQF T a.8 3 m 1. 46..2 a n5n5 TOF=4942.63 CONC. DRIVE wxK 4' ,! FTF , 4%9 15U.E. 415L Ad.a 1, 5.5' TT1EE/LAWN COMM. 39.7 (NO DRNNAGE PATTERN 2U ESDINQSHm NEf.) OF D HOUSE IR BACK OF CURD OW FINE PROBE 0 SO _' r; Enn D zD 40 �1s.•- ` P t2 SCALE V-20' PREPARED FOR: MERRAGE HOMES DA 11 LOT 1, BLOCK 10. KECHTER CROSSING PLANNED LAND DIVISION, COUNTY OF LARIMER, STATE OF COLORADO: ALSO KNOWN AS:5715 CROSSMEW DRIVE ELEVATION AND DRAINAGE CERTIFICATE I HEREBY CERTIFY THAT THE ELEVATION AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF. ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE MEASURED TO THE NEAREST 0.1 FEET. THERE IS SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND THE ELEVATION AND DRAINAGE PATTERNS MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PUN, DATED 06-11-14 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRAINAGE DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS. LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS SURVEY MAY NOT ACCURATELY DEPICT THE ELEVATION AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY. INK DOCUMENT K NOF AN NPROAD'ENT L TloN aRl w OR URD SURr PUT. M MKMf STAR DDES NOT 1/M Nff INK PROPpRY 10 w PIR[ E IRST, OF SYNIDING OR A pWNNG NMRR . MW M IWNMTWR,