HomeMy WebLinkAboutLot Certifications - 02/13/2015Utilities
City
electric. stormwater. wastewater. water
Of
Fort
oowoost
PO Box 580
Collins
Fort Collins, CO 60522
F
970.221.6700
970.221.6619619 fax . 970 224 6003 TOO
utilitiesio2fcgoy.com . rcgovcotWutdities
CERTIFICATION OF LOT GRADING
Pursuant to City Code 2fi 6-544 and City Land Use Code § 3.2.2 (e)
Date:
January 12, 2015
�F=
Permit Application
No. B1402980
COrtGa��d z/��zvtS
Address:
5715 Crossview Drive
Lot:
1 Block: 10 _
Subdivision: Kechter Crossing Planned Land Division
(,(Print) Steven M. Strickling , a Colorado registered professional engineer, verify that the above
referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified
professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete,
and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey
performed on (Date): January 6. 2015 , accurately and truly depict the elevations and drainage patterns as
they existed on the date of the survey. Based on this information, I certify that (check one):
The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
V The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved
drainage plan, and will affect stormwater drainage on and off tea manner consistent with the
approved drainage plan. SEE NOTE.
tt I q� l�12�2w3;•
By
(signature,yPE stamp)
10056 Brisbane Lane. Littleton, CO 80130
(address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including but not limited to drawings of the IoUsite showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written
information/explanation of discrepancies, and other information necessary to confirm the above certification to:
Fort Collins Utilities
700 wood street
Fort Collins, CO 80521
(970) 221.6700
Rev 1127112 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
CIVAS
engineering
January 12, 2015
FORT COLLINS UTILITIES
700 Wood Street
Fort Collins, Colorado 80521
Re: Lot 1, Block 10, Kechter Crossing Planned Land Division
Certification of Lot Grading
The elevations and drainage patterns for Lot 1, Block 10, Kechter Crossing Planned Land Division
are in general conformance with the City approved Final Grading Plan for Kechter Crossing
Planned Land Division, with one minor exception. A side yard swale was constructed in the
westerly side yard. The side yard swale discharges into Common Area C at the northwest property
corner and then flows to the west to a 15' diameter culvert under the sidewalk in Common Area
C as shown on the approved Final Grading Plan. The approved Final Grading Plan does not
indicate a side yard Swale, but instead indicates the side yard surface draining to the west and
directly to a swale in Common Area C. This swale conveys flows to the north to the above
mentioned 15" diameter culvert. Since Lot 1, Block 10 is indicated as a Type B draining lot, and
since drainage from the side yard of Lot 1, Block 10 to the 15' diameter culvert is maintained, it
is our professional opinion that this exception is not significant and will still allow for stormwater
drainage to generally be consistent with the City approved Final Grading Plan.
Sincerely,
A
Steven M.
Principal
10056 Brisbane Lane • utneton • CO •80130
tel 720-240-5882 -tax 720-223-6092
Z
v
J
Z<
w -4
z
1jL
Na -0 Z ' I
N rn
/ N N
J;
f
rr`I
rf�r
B10-L1 B10-L2
B B
TF=4943.50 TF=4943.00
PAD=4942.0
PAD=4942.00 I i
J•
O to OD V A C.1 N zz r
0 G�—ImD�O
m
c/)DDDNmtnc/i—a�—,vD—+��fl1NDN m�
mpmrmrmm2—xDz0�1 mmr
mpprm�mmm?m�m� �mmr
ppm p-,Z�OOCOZrr)—n �� c»xv Z
DZ i z pzo > A> 0
DOK V)LnMmmO�-;Oz�vvpim OZM—
(A1 z rn 0fnD�� ZCI+fC>>� Z=i m
xmp� -IxDm mpi9rm0 <O20n
D zm�pCrp-OUZ Z
cn A�Z v-nM rnZz��osr" �m�
�7zNo� iM;mo Cz�Z'D ��z
n!leg, Inc.
..._
6841 SOUTH YOSEMITE STREET #100
CENTENNIAL, CO 80112
41
ACcolwoll
t \
. • j 1 /
3T . 88.6 r —
T902 SQF T
a.8 3
m 1. 46..2 a
n5n5
TOF=4942.63
CONC. DRIVE wxK
4' ,!
FTF ,
4%9
15U.E.
415L Ad.a 1,
5.5' TT1EE/LAWN
COMM.
39.7
(NO DRNNAGE PATTERN
2U ESDINQSHm NEf.)
OF
D HOUSE
IR BACK OF CURD
OW FINE
PROBE 0 SO
_' r;
Enn
D zD 40 �1s.•- ` P t2
SCALE V-20' PREPARED FOR: MERRAGE HOMES DA 11
LOT 1, BLOCK 10. KECHTER CROSSING PLANNED LAND DIVISION, COUNTY OF LARIMER, STATE OF COLORADO:
ALSO KNOWN AS:5715 CROSSMEW DRIVE
ELEVATION AND DRAINAGE CERTIFICATE
I HEREBY CERTIFY THAT THE ELEVATION AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY
OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF.
ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE
MEASURED TO THE NEAREST 0.1 FEET. THERE IS SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND
THE ELEVATION AND DRAINAGE PATTERNS MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PUN, DATED
06-11-14 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE
OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRAINAGE
DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS. LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS
SURVEY MAY NOT ACCURATELY DEPICT THE ELEVATION AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY.
INK DOCUMENT K NOF AN NPROAD'ENT L TloN aRl w OR URD SURr PUT.