HomeMy WebLinkAboutLot Certifications - 03/30/1995AIRES ASSOCIATES Formerly Resource Consultants & Engineers (RCE) March 16, 1995 Mr. Basil Hamdan City of Fort Collins Stormwater Utility 235 Mathews Fort Collins, Colorado 80521 Re: Lot 139,-Huntington=Hills—_Filing23;- Dear Basil: o� t' As required by the hold placed on the certification of'occupancy, we have observed the back yard Swale and surveyed the elevations of the backyard property corners. The Swale has been completed and will drain storm water between lots 127/139 and 126/140 to the drainageway. The lower section of the Swale is less than 2 percent slope and a drain was installed. Please refer to enclosed picture. The elevation of the northwest property corner is 4952.7 and the southwest is.4951.6. The northwest corner is 0.2 foot higher than planned and the southwest corner. is 1.6 foot higher than planned. The northwest corner fits the surround grade. The southwest corner was raised when the sanitary sewer manhole was raised to provide more slope for the Swale south of the property corner. It is our recommendation to release the hold placed on this lot since the contractor did a good job to adequately drain the lot. If you have any questions, please call. Sincerely, Ayres Associates, formerly (Resource Consultants & Engineers Paul R. Barker, P.E. Manager, Civil Engineering PRB:sp Owen Ayres & Associates, Inc. Engineers/Scientists/Surveyors HAMD-38.LTR 3665 JFK Parkway, Building 2, Suite 300, P.O. Box 270460, Fort Collins, CO 80527 34-0236.00 ' (303) 223-5556, Denver Metro (303) 572-1806, FAX (303) 223-5578 Printed on recycled paper BACKYARD DRAINAGE SWALES BEHIND LOTS 1389 139, & 140.