HomeMy WebLinkAboutLot Certifications - 06/01/1995FOUNDATION II- ConsuIting' ENGINEERING Engineers, Ltd. June 1, 1995 Commission No.: 1892-02-06-04 Rossi Homes, Inc. 5900 Colby Street Fort Collins, Colorado 80525 RE: Lot 119, Huntington Hills Second Filing (327 Brinn Court), Fort Collins, Colorado Gentlemen: We have visually inspected the existing home at the above referenced address. This inspection was performed on May 31, 1995. The home consists of a split level, wood frame and brick veneer structure constructed on a relatively steep slope to the south. Inspection of the home indicates little damage to the foundation system. Cracking of drywall has appeared around the stairs. However, it is our understandingthat the stair walls were not properly isolated.. Isolation of the stair system should correct this problem. In addition, the basement slab appears to be capped over the walk -out basement wall. To prevent future damage, we recommend the slab be cut clear through approximately twelve (12) inches out from the foundation at the walk -out area. To correct poor drainage on the north side of the home, we recommend construction of a concrete slab from the foundation to the property line, full width of_the house. The slab should be warped to provide drainage along the property line to the rear. A twenty-four (24) inch wide by.. four (4) inch deep concrete pan should extend from the slab along the north property line, then approximately twenty (20) feet along the west property line. A similar pan should extend east along the north property line to the sidewalk. We recommend graveling the remainder of the yard north of the drive and north of the back patio. North -facing downspouts shall drain to the new pan. Currently, the back patio has heaved, causing negative drainage. This should be corrected by replacing the patio and releveling the deck. The downspout at the south front corner of the garage has been placed underground, daylighting several feet from the property line. This pipe should be solid, rigid pipe extending to the property line at 1/8 inch per foot. 100 East 3rd Street 0 Loveland, Colorado 80537 •'R (303) 663-0138 Y . J June 1, 1995 Commission No.: Page 2 1892-02-06-04 The garage door jambs are restraining the slab from moving vertically. These jambs should be cut short 1-1/211. This inspection consisted of visual observation only, made solely to determine the structural integrity of the described building. Neither the inspection nor the report is intended to cover mechanical, electrical or architectural features of the building inspected. If you have an uest', ' "".&9 se ,feel free to call. Y Y 4 1,5�� R#�� Respectfully i a` J 23841 �E ; Kevin W. Patterson,3A FOUNDATION ENGINEERIN T-N ,ENGINEERS, LTD. KWP/jlb 0 G