Loading...
HomeMy WebLinkAboutLot Certifications - 11/19/2009 (2) Utit i ties electric • storin�vater • wastewater • water City of Fort Collins CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) 6� Date: November 16, 2009 `3 3of7 Permit Application No. b Address: 2526 Parkfront Drive Units A-D Lots: 21-24 Block: n/a Subdivision: Rigden Farm, 7" Filing I, Michael Shawn Brake, a Colorado registered Professional Engineer and Land Surveyor, have personally inspected the above referenced property in the City of Fort Collins, Colorado, and verify that construction of all stormwater facilities and grading there is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on November 3, 2009, accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): he elevations and drainage patterns of the lot are in substantial conformance with the City approved drainage and grading plan or revised grading plan for the property (information attached). SEE NOTE. ❑ The elevations and drainage patterns of the lot as measured are in general conformance with the City approved drainage plan or revised grading plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot as constructed is functionally adequate and will allow for stormwater drainage consistent with the approved drainage plan. SEE NOTE. By: M1cha I Sh n rake, E-PLS 28262 JR Engineering 2620 East Prospect Road, Suite 190 Fort Collins.. CO 8055 NOTE: A COMPLETE certification must be submitted, including but not limited to drawings of the lot/site showing the approved design or revised design and as-built surveyed elevations of all structures and drainage and grading features(e.g.swales,retaining walls, lot corners),written information/explanation of discrepancies,etc.to: Fort Collins utilities(970)221-6700 700 Wood Street Fort Collins,CO 80521 At Least Two Weeks Prior To Requesting A Certificate Of Occupancy For The Property 5 7 (g� 18•a I A Westrian Company 1g 2 N' 2620 East Prospect Road • Ft Collins, CO 80525 (970-491-9888•Fax (970)491—9984•www)rengireering.com I J 1�'•oHP � `•�,�o o "�O �ry DRAINAGE CERTIFICATION 3, � �,� RIGDEN FARMS 7TH FILING WW=19.4 LOT: 21-24 BLOCK: N/A i 9 1 ADDRESS: 2526 PARKFRONT DR. (A—D) Q18 5 '. WW=19.4 1 5 CITY: FORT COLLINS COUNTY: LARIMER �86 TOS=19.4 LOT 21 J STATE: COLORADO TOF=19.7 c FF=20.0 MODEL: TOWNHOME BUILDING NO. 3 THE ATTACHED DRAWING SHOWS THE ELEVATIONS AND DRAINAGE PATTERNS THAT ARE THE REGISTERED PROFESSIONAL ENGINEERS CERTIFIED FINDINGS OF THE FOR THE LOT 22 19 5 PIROPERDTY ANDNARER NDES GENERAL CONFBORMANCECTO TDHE TOS=19.4 19.2 3 TOF=19.7 � APPROVED DRAINAGE AND GRADING PLAN EXCEPT AS FF=20.0 NOTED. THE ELEVATIONS AS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE OF THE SURVEY E WW=19.3 DUE TO NATURAL AND/OR ARTIFICIAL ACTIONS. 1 8. MICHAEL SHAWN BRAKE. PE—PLS 2826 a WW=19 3 FOR AND ON BEHALF QS OF JR ENGINEERING LLC. o ,.N 1 7.0 N ABo TOS=19.0 LOT 23 17 o �8� TOF=19.5 20 10 0 20 INFORMATION RECORDED ON: 1-0 0� -�%` N FF=19.9 J; J 18.1 1 TOP OF FOUNDATION: AS NOT •• STEPS w SCALE: 1 = 20' FINISHED FLOOR: AS NOTED £ A N Q�. V)Q LOT 24 WINDOW WELL: AS NOTED TOS-18.7 � LEGEND: TOP OF SLAB: AS NOTED TOF=19.3 p DESIGN N FF=19.7 �0i STEP SPOT ELEVATION AS BUILT WW=18.8 Y 1j.3 %°� p E Q •. m NO. REVISION BY DATE c Z � N 0 �S O CONC. WALKCN �6 5 _ TRENCH DRAIN —�_ GRATE=17.5 j = FLOWLINE=16.5 o % PRUDENTIAL PRIME PROPERTIES PARK FRONT DRIVE INLET FLOWLINE=15.6 KEY MAP PROJECT p: 39572.00 DRAWN BY: MIRE DATE: 11-16-09 NOT TO SCALE ' X