HomeMy WebLinkAboutSite Certifications - 02/04/20225265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 • GallowayUS.com December 27, 2021 Wes Lamarque Water Utilities Engineering City of Fort Collins 222 Laporte Avenue Fort Collins, CO 80524 RE: Timbervine Second Filing Drainage Certification Dear Wes, Please find this letter to accompany the Overall Site and Drainage Certification for the Timbervine Second Filing project, originally issued March 24, 2017. A punch walk was performed on November 2nd, 2018 to observe the completion of items identified within the certification checklist. Present at the punch walk were representatives from the City, the Owner, and the Owner’s Engineer. A punch list of outstanding items needing to be addressed for completion of the Certification was issued by the Engineer on November 12, 2018. I personally have reviewed the original Certification and walked the project site on December 27, 2021 to verify that those outstanding items have been addressed. Please find below responses to those items as outlined within the punch list and a brief description of how those were addressed. Item 1 - Existing side yard swale: re-grade to drain from sidewalk chase to existing riprap. Revegetate and provide temporary sediment and erosion control within the re-graded swale until the new vegetation has matured. A primary concern will be minor rill and gulley erosion within the re-graded swale during irrigation season (i.e., local homeowners water their lawns). Response: The swale has been regraded to establish positive drainage from the sidewalk chase to the existing riprap at the swale to the east. A concrete pan has been installed along the swale. Vegetation has been properly established within and along the re-graded swale. Temporary erosion control measures have been removed given presence of established vegetation. Item 2 - Existing side yard swale: re-grade to drain from sidewalk chase to existing riprap. Revegetate and provide temporary sediment and erosion control within the re-graded swale until the new vegetation has matured. A primary concern will be minor rill and gulley erosion within the re-graded swale during irrigation season (i.e., local homeowners water their lawns). Response: The swale has been regraded to establish positive drainage from the sidewalk chase to the existing riprap at the swale to the east. A concrete pan has been installed along the swale. Vegetation has been properly established within and along the re-graded swale. Temporary erosion control measures have been removed given presence of established vegetation. Item 3 - Existing side yard swale: re-grade to drain from sidewalk chase to existing riprap. Revegetate and provide temporary sediment and erosion control within the re-graded swale until the new vegetation has matured. A primary concern will be minor rill and gulley erosion within the re-graded swale during irrigation season (i.e., local homeowners water their lawns). Response: The swale has been regraded to establish positive drainage from the sidewalk chase to the existing swale to the south. A concrete pan has been installed along the swale. Vegetation has been properly established within and along the re-graded swale. Temporary erosion control measures have been removed given presence of established vegetation. Wes Lamarque 2/4/2022 Timbervine Second Filing Drainage Certification December 27, 2021 Galloway & Company, Inc. Page 2 of 2 Item 4 - Existing Modular Block Pavers (MBPs): the existing sections along the centerlines of Pilsner Street and Pale Ale Street have settled. These sections need to raised to grade and reinstalled. It is recommended that the contractor performing this work be certified by the Interlocking Concrete Paver Institute (ICPI). Response: Modular Block Paver sections have been re-graded and re-installed to address settlement along Pilsner Street and Pale Ale Street. Item 5 - Existing MBPs: the existing sections along Sour Street, Shandy Street and Pint Street were cleaned/reset/etc. and accepted by the City of Fort Collins. Wes and I walked the pavers along Shandy Street and Pint Street. These pavers require additional filler material (i.e. No. 8 stone) between the pavers. Response: Fill stone has been installed between pavers as needed in areas mentioned at Shandy and Pint Streets. Thank you for your review of this Overall Site and Drainage Certification. Should you have any questions, please do not hesitate to contact me 970.800.3300. Sincerely, GALLOWAY Donald B. Cecil, P.E. Senior Civil Project Engineer 970.800.3300 DonaldCecil@GallowayUS.com 1 Wes Lamarque From:Herman Feissner <HermanFeissner@gallowayus.com> Sent:Monday, November 12, 2018 11:52 AM To:Wes Lamarque Cc:Patrick McMeekin; Rob Van Uffelen; James Prelog Subject:SPHLV01.01 - Timbervine | November 2nd, 2018 Site Visit Follow-Up Attachments:SPHLV01.01_Site Visit_Exhibit.pdf Hello Patrick and Wes, Thank you meeting on-site November 2nd, 2018 to observe and discuss the condition of several existing storm drain improvements. Included with this message is a document illustrating the specific areas we observed and discussed. The numbers shown below match the numbers shown on sheets G1, G2 and G3. 1 – Existing side yard swale: re-grade to drain from sidewalk chase to existing riprap. Revegetate and provide temporary sediment and erosion control within the re-graded swale until the new vegetation has matured. A primary concern will be minor rill and gulley erosion within the re-graded swale during irrigation season (i.e., local homeowners water their lawns). 2 – Existing side yard swale: re-grade to drain from sidewalk chase to existing riprap. Revegetate and provide temporary sediment and erosion control within the re-graded swale until the new vegetation has matured. A primary concern will be minor rill and gulley erosion within the re-graded swale during irrigation season (i.e., local homeowners water their lawns). 3 – Existing side yard swale: re-grade to drain from sidewalk chase to existing riprap. Revegetate and provide temporary sediment and erosion control within the re-graded swale until the new vegetation has matured. A primary concern will be minor rill and gulley erosion within the re-graded swale during irrigation season (i.e., local homeowners water their lawns). 4 – Existing Modular Block Pavers (MBPs): the existing sections along the centerlines of Pilsner Street and Pale Ale Street have settled. These sections need to raised to grade and reinstalled. It is recommended that the contractor performing this work be certified by the Interlocking Concrete Paver Institute (ICPI). 5 – Existing MBPs: the existing sections along Sour Street, Shandy Street and Pint Street were cleaned/reset/etc. and accepted by the City of Fort Collins. Wes and I walked the pavers along Shandy Street and Pint Street. These pavers require additional filler material (i.e. No. 8 stone) between the pavers. This list covers the areas we discussed during the site visit. Once the improvements mentioned above are complete and accepted, I understand the City of Fort Collins will approve the Overall Site and Drainage Certification and support transfer of the improvements to the local Homeowners Association or similar entity. Please reply to this message stating that you agree with the above list or with corrections and/or additions. Galloway Herman Feissner, PE SR. CIVIL PROJECT ENGINEER 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 O 970.800.3300 HermanFeissner@GallowayUS.com GallowayUS.com COLORADO | CALIFORNIA | UTAH Nationally Recognized. Locally Preferred. March 24th, 2017 Wes Lamarque City of Fort Collins Stormwater Utility 222 Laporte Avenue Fort Collins, Colorado 80524 RE: Timbervine Second Filing Drainage Certification Wes, This letter accompanies the Overall Site and Drainage Certification (see attached). Some sections of this document require additional explanation. Those sections are referenced below. I.Water Quality and Quantity Detention Basin Certification - FCSCM Vol.2, Ch.10 A.Volume- N/A B.Water Quality and Quantity Detention Basin Grading: The grades are ±1.5%, which is consistent with the approved Utility Plans (dated: 09/2015). 1.Low Flow: The engineer did not observe the soft bottom pan installation. 2.Side Slopes: N/A 3.Spillway Certification: The observed obstructions are minimal and include a few small caliper diameter trees. 4.Outlet Structure Certification: The orifice plate is installed ±0.61’ above the pipe invert. The approved design shows an orifice pale 061’ above the pipe invert. II.Channels/Swales - FCSCM Vol.1, Ch.7, Sect.3&4 A.Capacity: 1. The swales were approved with flatter longitudinal slopes (e.g., 0.30%). III.Storm Pipes (aka storm drains) - FCSCM Vol.1, Ch.6, Sec. 4 A.Storm Drain Pipe Capacity: 1. The engineer was not present during the installation to verify ALL storm drain pipe sizes and materials. A reasonable effort was made to confirm material types and pipe sizes where visible (e.g., at an FES). 2. The storm drain design was approved with flatter slopes (i.e., 0.20%). B.Storm Drain Pipe Installation Requirements: The responses in this section are N/A. The engineer was not present during the storm drain installation to reasonably answer this section for ALL storm drain installed with this project. IV.Concrete Pans - FCSCM Vol.1, Ch.7, Sec.4.1.3.4 A.Construction/Installation: 4. The engineer did not observe the concrete pan construction to confirm the reinforcement. V.Storm Drain Inlets - FCSCM Vol.1, Ch.6, Sec. 3 A.Construction/Installation: N/A Revised December 27, 2021 - See Revisions in Red 5. The inlet sizes are not labeled on the drawing; however, each was checked in the field and confirmed to be the correct size. 6. The Inlet covers are stenciled with “NO DUMPING DRAINS TO RIVERS” VI.Culverts - FCSCM Vol.2, Ch.9 A.Construction/Installation: N/A VII.Sub-Drains A.Construction/Installation: The engineer was not present during construction to verify the sub-drain construction an installation. This applies for items 1 through 6 of this section. VIII.Curb Cuts A.Construction: N/A IX.Sidewalk Culverts & Chases A.Construction/Installation: N/A X.Site Grading A.Construction: 1. Grading activity of some common areas, which are associated with the current phase of development, is on-going. The grading in these areas should not affect the drainage infrastructure. 2. Acknowledged. The majority of the lots in Phases 1 and 4 should have lot plans. Phases 2 and 3, are in the process of being overlot graded. XI.Riprap - FCSCM Vol.1, Ch.7, Sec.4.4.4.3 A.Construction: N/A XII.Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7 A.Construction: N/A XIII.Post-Construction Site Cleanup - FCSCM Vol.3, Ch.7 A.Construction: At the time of observation, construction of the townhomes and single-family homes is on-going; therefore, construction debris may occasionally be present and is routinely cleaned-up. XIV.Certification of Other Permanent BMPs - FCSCM Vol.2, Ch.8, Sec.2 & FCSCM Vol.2, Ch.12 XV.Certification of LID and Water Quality Facilities - FCSCM Vol.3, Ch.4 See attached Contractor Portion XVI.Certification and Erosion Control Measures Construction activity is on-going. The temporary erosion control measures are the responsibly of the SWMP Administrator. Grading activities were observed as complete on 12.27.2021. Grades are in general conformance with the grading plan. Temporary measures have been removed from the site as observed on 2021.12.27 Grading activities were observed as complete on 12.27.2021. Grades are in general conformance with the grading plan. YES (2021.12.27) YES (2021.12.27) YES (2021.12.27) Donald B. Cecil, P.E. donaldcecil@gallowayus.com 970.800.3300 Galloway & Company, Inc. 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 5265 Ronald Reagan Blvd., Ste 210 Johnstown, CO 80534 5013 PROPOSED CONTOUR 93 EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED PAN EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES PROPOSED STORM INLET 2.0% (47.42) EXISTING SPOT ELEVATION PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) PROPOSED RIGHT OF WAY LOT TYPE PERMEABLE PAVER KEYMAP E. VINE DR. S. TIM BERLINE RD. TIMBERVINE # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 MATCHLINE-SEE SHEET G2 MATCHLINE-SEE SHEET G3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND:NOTES: 1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION. 2.REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION. 3.ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4800 OR 4900 FEET (96.97 = 4896.97 AND OR 00.71 = 4900.71). 4.CONTOURS SHOWN OUTSIDE OF STREET R.O.W. ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET R.O.W. ARE FINISHED GRADE. 5.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR LANDSCAPE AREAS. 6.SEE DETAIL SHEETS FOR LOT TEMPLATES. 7.4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED. 8.WALLS SHOWN FOR GRADING PURPOSES ONLY, TO BE STRUCTURALLY DESIGNED BY OTHERS IF NECESSARY. 9.SEE SECTION 3.4.1 OF LANDUSE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 10. ALL DISTURBED AREAS SHALL BE REVEGITATED PER THE APPROVED LANDSCAPE PLAN. 11. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE INDIVIDUAL FOOTPRINTS ARE DETERMINED. 32.50 @ 0.45% 20.3 LF @ 0.50% REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: AUGUST 31, 2016 3 08/31/2016 Record Drawings JEP 23.8 LF @ 0.97% 35.12 34.92 19.7 LF @ 1.02% 36.33 36.56 33.84 33.57 40.3 LF @ 0.67% .46% 0.46% 0.40% KEYMAP E. VINE DR. S. TIM BERLINE RD. TIMBERVINE # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 MATCHLINE-SEE SHEET G1 MATCHLINE-SEE SHEET G3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED PAN EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES PROPOSED STORM INLET 2.0% (47.42) EXISTING SPOT ELEVATION PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) PROPOSED RIGHT OF WAY LOT TYPE PERMEABLE PAVER 1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION. 2.REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION. 3.ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4800 OR 4900 FEET (96.97 = 4896.97 AND OR 00.71 = 4900.71). 4.CONTOURS SHOWN OUTSIDE OF STREET R.O.W. ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET R.O.W. ARE FINISHED GRADE. 5.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR LANDSCAPE AREAS. 6.SEE DETAIL SHEETS FOR LOT TEMPLATES. 7.4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED. 8.WALLS SHOWN FOR GRADING PURPOSES ONLY, TO BE STRUCTURALLY DESIGNED BY OTHERS IF NECESSARY. 9.SEE SECTION 3.4.1 OF LANDUSE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 10. ALL DISTURBED AREAS SHALL BE REVEGITATED PER THE APPROVED LANDSCAPE PLAN. 11. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE INDIVIDUAL FOOTPRINTS ARE DETERMINED. NOTES: 32.70 32.57 1.33% 0.50% 4 03/24/2017 Record Drawings JEP 0.90% ±50' WIDE SPILLWAY CREST ELEV.=4932.8 18.31 LF @ 0.70% 32.50 @ 0.45% 20 LF @ 0.50% REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: AUGUST 31, 2016 REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: MARCH 2017 KEYMAP E. VINE DR. S. TIM BERLINE RD. TIMBERVINE # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 MATCHLINE-SEE SHEET G2 MATCHLINE-SEE SHEET G1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED PAN EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES PROPOSED STORM INLET 2.0% (47.42) EXISTING SPOT ELEVATION PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) PROPOSED RIGHT OF WAY LOT TYPE PERMEABLE PAVER 1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION. 2.REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION. 3.ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4800 OR 4900 FEET (96.97 = 4896.97 AND OR 00.71 = 4900.71). 4.CONTOURS SHOWN OUTSIDE OF STREET R.O.W. ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET R.O.W. ARE FINISHED GRADE. 5.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR LANDSCAPE AREAS. 6.SEE DETAIL SHEETS FOR LOT TEMPLATES. 7.4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED. 8.WALLS SHOWN FOR GRADING PURPOSES ONLY, TO BE STRUCTURALLY DESIGNED BY OTHERS IF NECESSARY. 9.SEE SECTION 3.4.1 OF LANDUSE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 10. ALL DISTURBED AREAS SHALL BE REVEGITATED PER THE APPROVED LANDSCAPE PLAN. 11. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE INDIVIDUAL FOOTPRINTS ARE DETERMINED. NOTES: 1 04/12/2016 Record Drawings JEP 30.81 31.9 LF @ 3.80% 26.6 LF @ 0.41% 32.50 32.61 32.50 REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: MARCH 29, 2016 3 08/31/2016 Record Drawings JEP 32.50 @ 0.45% 20 LF @ 0.50% REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: AUGUST 31, 2016 32.02 0.32% 0.22% 4 03/24/2017 Record Drawings JEP TYP. REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: MARCH 2017 # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 LAKE CANAL RESERVOIR COMPANY APPROVAL CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R KEYMAP E. VINE DR. S. TIM BERLINE RD. TIMBERVINE G4 LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED PAN EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES PROPOSED STORM INLET 2.0% (47.42) EXISTING SPOT ELEVATION PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) PROPOSED RIGHT OF WAY LOT TYPE PERMEABLE PAVER 1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION. 2.REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION. 3.ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4800 OR 4900 FEET (96.97 = 4896.97 AND OR 00.71 = 4900.71). 4.CONTOURS SHOWN OUTSIDE OF STREET R.O.W. ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET R.O.W. ARE FINISHED GRADE. 5.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR LANDSCAPE AREAS. 6.SEE DETAIL SHEETS FOR LOT TEMPLATES. 7.4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED. 8.WALLS SHOWN FOR GRADING PURPOSES ONLY, TO BE STRUCTURALLY DESIGNED BY OTHERS IF NECESSARY. 9.SEE SECTION 3.4.1 OF LANDUSE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 10. ALL DISTURBED AREAS SHALL BE REVEGITATED PER THE APPROVED LANDSCAPE PLAN. 11. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE INDIVIDUAL FOOTPRINTS ARE DETERMINED. NOTES: 4 03/24/2017 Record Drawings JEP TYP. TYP. REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: MARCH 2017 Galloway Job Name:Timbervine 3760 E. 15th Street, Suite 202 Job Number:SPHLV0001.01 Loveland, CO 80538 Date:3/13/2017 Ph: (970) 800-3300 By:J. Prelog Timbervine Detention Pond Volume Calculations: FAA Procedure Based on FAA Procedure, per Federal Aviation Agency "Airport Drainage" Manual Drainage Basin A Design Storm 100 year Composite "C" Factor 0.59 Basin Size 24.68 Release Rate Calculations Allowable Release Rate for Pond 8.70 cfs Rainfall Intensity Calculations Point Hour Rainfall (P1) :2.86 Rainfall Intensity:FortCollinsIDF Volume Calculations Inflow Volume = C * I * A * time (sec) Outflow Volume = Alowable Release Rate * time (sec) Storage Volume = Invflow Volume - Outflow Volume Time t (min) Time t (sec) Intensity I (in/hr) Inflow Vin (ft3) Outflow Vout (ft3) Storage Vstor (ft3) 5.0 300 9.95 43,307 2,610 40,697 10.0 600 7.72 67,201 5,220 61,981 15.0 900 6.52 85,133 7,830 77,303 20.0 1,200 5.85 101,905 10,440 91,465 25.0 1,500 5.19 112,873 13,050 99,823 30.0 1,800 4.52 118,038 15,660 102,378 35.0 2,100 4.25 129,450 18,270 111,180 40.0 2,400 3.97 138,309 20,880 117,429 45.0 2,700 3.70 144,761 23,490 121,271 50.0 3,000 3.42 148,803 26,100 122,703 55.0 3,300 3.14 150,438 28,710 121,728 60.0 3,600 2.86 149,375 31,320 118,055 Maximum Volume (ft3)122,703 Fort Collins Only (120%) 24,541 Required 100-yr Volume 147,244 ft3 Detention Storage Calculations 8214_Rational Calculations.xlsx FAA-100-yr (A)Page 1 of 1 Project:Timbervine Project Location:Fort Collins, Colorado Date: 3/13/2017 Calculations By:H. Feissner Pond Description:Detention Pond A User Input Cell:Blue Text Design Point:FES B3 Design Storm:WQCV Required Volume:3100 ft3 4929.02 ft Design Storm:10-year Required Volume:0 ft3 4928.00 ft Design Storm:1st 100-year Required Volume:145964 ft3 4932.68 ft Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4927.94 0 0.0 0 0 0 0 4928.00 0 0.1 0 0 0 0 0.0 4929.00 8364 1.0 4182 4182 2788 2788 0.1 4930.00 19591 1.0 13977 18159 13585 16373 0.4 4931.00 39580 1.0 29586 47745 29006 45379 1.0 4932.00 65147 1.0 52364 100109 51836 97215 2.2 4933.00 78282 1.0 71714 171823 71614 168829 3.9 Detention Pond A Stage-Storage Calculations (As-Built) Required Volume Water Surface Elevation Average End Area Method:Conic Volume Method: 1st 100-year 4927 4928 4929 4930 4931 4932 4933 4934 0 20000 40000 60000 80000 100000 120000 140000 160000 180000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Detention Pond Galloway Job Name: 3760 E. 15th Street, Suite 202 Job Number: Loveland, CO 80538 Date: Ph: (970) 800-3300 By: Timbervine Detention Pond Volume Calculations: FAA Procedure Based on FAA Procedure, per Federal Aviation Agency "Airport Drainage" Manual Drainage Basin B Design Storm 100 year Composite "C" Factor 0.59 Basin Size 14.51 Release Rate Calculations Allowable Release Rate for Pond 7.84 cfs Rainfall Intensity Calculations Point Hour Rainfall (P1) :2.86 Rainfall Intensity:FortCollinsIDF Volume Calculations Inflow Volume = C * I * A * time (sec)+Vout (Pond A) Outflow Volume = Alowable Release Rate * time (sec) Storage Volume = Invflow Volume - Outflow Volume Time t (min) Time t (sec) Intensity I (in/hr) Inflow Vin (ft3) Outflow Vout (ft3) Storage Vstor (ft3) 5.0 300 9.95 28,267 2,352 25,915 10.0 600 7.72 45,034 4,704 40,330 15.0 900 6.52 58,268 7,056 51,212 20.0 1,200 5.85 70,814 9,408 61,406 25.0 1,500 5.19 79,922 11,760 68,162 30.0 1,800 4.52 85,592 14,112 71,480 35.0 2,100 4.25 94,963 16,464 78,499 40.0 2,400 3.97 102,822 18,816 84,006 45.0 2,700 3.70 109,254 21,168 88,086 50.0 3,000 3.42 114,259 23,520 90,739 55.0 3,300 3.14 117,838 25,872 91,966 60.0 3,600 2.86 119,818 28,224 91,594 Maximum Volume (ft3)91,966 Fort Collins Only (120%)18,393 100%WQCV 32,409 ft3 Required 100-yr Volume +100%WQCV 142,768 ft3 Detention Storage Calculations 8214_Rational Calculations.xlsx FAA-100-yr (B)Page 1 of 2 Project:Timbervine Project Location:Fort Collins, Colorado Date: 3/13/2017 Calculations By:H. Feissner Pond Description:Detention Pond B User Input Cell:Blue Text Design Point:POND B OUTLET STRUCTURE Design Storm:WQCV Required Volume:29309 ft3 4929.02 ft Design Storm:10-year Required Volume:0 ft3 4927.00 ft Design Storm:1st 100-year Required Volume:142768 ft3 147243 4932.14 ft Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4926.94 0 0.0 0 0 0 0 4927.00 0 0.1 0 0 0 0 0.0 4928.00 18339 1.0 9170 9170 6113 6113 0.1 4929.00 26881 1.0 22610 31780 22475 28588 0.7 4930.00 33012 1.0 29947 61727 29894 58482 1.3 4931.00 38645 1.0 35829 97555 35792 94274 2.2 4932.00 44723 1.0 41684 139239 41647 135921 3.1 4933.00 51537 1.0 48130 187370 48090 184011 4.2 Detention Pond B Stage-Storage Calculations (As-Built) Required Volume Water Surface Elevation Average End Area Method:Conic Volume Method: 1st 100-year 4926 4927 4928 4929 4930 4931 4932 4933 4934 0 20000 40000 60000 80000 100000 120000 140000 160000 180000 200000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Detention Pond Project:Timbervine Project Location:Fort Collins, Colorado Date: 3/13/2017 Calculations By:H. Feissner Pond Description:Detention Ponds A & B (Combined) User Input Cell:Blue Text Design Point:POND B OUTLET STRUCTURE Design Storm:WQCV Required Volume:32409 ft3 4929.00 ft Design Storm:10-year Required Volume:0 ft3 4927.00 ft Design Storm:1st 100-year Required Volume:290012 ft3 4932.46 ft Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4926.94 0 0.0 0 0 0 0 4927.00 0 0.1 0 0 0 0 0.0 4928.00 18339 1.0 9170 9170 6113 6113 0.1 4929.00 35245 1.0 26792 35962 26336 32449 0.7 4930.00 52603 1.0 43924 79886 43635 76085 1.7 4931.00 78226 1.0 65414 145300 64992 141077 3.2 4932.00 109871 1.0 94048 239348 93601 234678 5.4 4933.00 129819 1.0 119845 359193 119706 354384 8.1 Detention Ponds A and B | Combined Stage-Storage Calculations (As-Built) Required Volume Water Surface Elevation Average End Area Method:Conic Volume Method: 1st 100-year 4926 4927 4928 4929 4930 4931 4932 4933 4934 0 50000 100000 150000 200000 250000 300000 350000 400000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Detention Pond Galloway Job Name:Timbervine 3760 E. 15th Street, Suite 202 Job Number:SPHLV0001.01 Loveland, CO 80538 Date:3/13/2017 Ph: (970) 800-3300 By:J. Prelog ORIFICE PLATE AT OUTLET PIPE WORKSHEET Orifice Plate using Headwater above opening and Q=cA(2gH)^.5 C= 0.65 QMAJOR allowable release rate:7.84 cfs Summary of Available Pipe Releases 100-yr Water Surface Elev:4932.46 ft Pipe Dia Area Head H Q Inv Elev at Outlet Struct:4926.94 ft Outfall Pipe at centroid avail out Outlet Pipe at Structure:24 in (in)(sf)(ft)(cfs) 12 0.79 5.02 9.17 15 1.23 4.90 14.16 18 1.77 4.77 20.12 24 3.14 4.52 34.82 30 4.91 4.27 52.88 36 7.07 4.02 73.89 Q=cA(2gH)^.5 C=0.65 Iteration process Q 7.84 cfs c 0.65 Hhead 4.52 ft Needed Area 0.71 sf Using Area- determine Ao 0.71 sf Apipe 3.14 sf theta 4.06 rad Ao-calc'd 0.71 sf m -0.44 ft distance above(+) or below(-) center H 0.56 ft Height above pipe invert úû ùêë é ÷ø öçè æ÷ø öçè æ+úû ùêë é ÷ø öçè æ -=2cos*2sin2 2 qq p qp rrAApipeo ÷ø öçè æ=2cosqrm mrH+= 8214_Rational Calculations.xlsx Major Orifice Page 1 of 1 # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 SOFT BOTTOM PAN ORIFICE PLATE DETAIL PERMEABLE PAVER OUTFALL INTERLOCKING CONCRETE PAVER CROSS SECTION BIORETENTION / BIOSWALE CROSS SECTION 1 2 3 4 CLAY CUTOFF WALL5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R 4926.80 4929.10 4930.10 4932.95 2.30 4.00 4.00 1.00 1-1/2 6 1 (FT) (FT) (FT) (IN) (FT) 4926.94 4929.26 4930.21 4 03/24/2017 Record Drawings JEP Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.035 Channel Slope 0.46 % Left Side Slope 4.00 ft/ft (H:V) Right Side Slope 4.00 ft/ft (H:V) Bottom Width 4.00 ft Discharge 3.06 ft³/s Results Normal Depth 0.41 ft Flow Area 2.31 ft² Wetted Perimeter 7.37 ft Hydraulic Radius 0.31 ft Top Width 7.27 ft Critical Depth 0.24 ft Critical Slope 0.03082 ft/ft Velocity 1.33 ft/s Velocity Head 0.03 ft Specific Energy 0.44 ft Froude Number 0.42 Flow Type Subcritical GVF Input Data Downstream Depth 0.00 ft Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 ft Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 0.41 ft Critical Depth 0.24 ft Channel Slope 0.46 % Design Point 3 Swale_AB 3/13/2017 5:04:19 PM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page Design Point 3 Swale_AB GVF Output Data Critical Slope 0.03082 ft/ft 3/13/2017 5:04:19 PM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.035 Channel Slope 0.23 % Left Side Slope 4.00 ft/ft (H:V) Right Side Slope 4.00 ft/ft (H:V) Bottom Width 4.00 ft Discharge 25.78 ft³/s Results Normal Depth 1.42 ft Flow Area 13.82 ft² Wetted Perimeter 15.75 ft Hydraulic Radius 0.88 ft Top Width 15.40 ft Critical Depth 0.83 ft Critical Slope 0.02210 ft/ft Velocity 1.87 ft/s Velocity Head 0.05 ft Specific Energy 1.48 ft Froude Number 0.35 Flow Type Subcritical GVF Input Data Downstream Depth 0.00 ft Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 ft Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.42 ft Critical Depth 0.83 ft Channel Slope 0.23 % Design Point 5 Swale_AB 3/13/2017 5:03:54 PM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page Design Point 5 Swale_AB GVF Output Data Critical Slope 0.02210 ft/ft 3/13/2017 5:03:54 PM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.035 Channel Slope 0.30 % Left Side Slope 4.00 ft/ft (H:V) Right Side Slope 4.00 ft/ft (H:V) Bottom Width 4.00 ft Discharge 31.17 ft³/s Results Normal Depth 1.46 ft Flow Area 14.41 ft² Wetted Perimeter 16.06 ft Hydraulic Radius 0.90 ft Top Width 15.70 ft Critical Depth 0.91 ft Critical Slope 0.02151 ft/ft Velocity 2.16 ft/s Velocity Head 0.07 ft Specific Energy 1.54 ft Froude Number 0.40 Flow Type Subcritical GVF Input Data Downstream Depth 0.00 ft Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 ft Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.46 ft Critical Depth 0.91 ft Channel Slope 0.30 % Design Point 6 Swale_AB 3/13/2017 5:03:21 PM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page Design Point 6 Swale_AB GVF Output Data Critical Slope 0.02151 ft/ft 3/13/2017 5:03:21 PM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.035 Channel Slope 0.54 % Left Side Slope 4.00 ft/ft (H:V) Right Side Slope 4.00 ft/ft (H:V) Discharge 4.21 ft³/s Results Normal Depth 0.80 ft Flow Area 2.54 ft² Wetted Perimeter 6.57 ft Hydraulic Radius 0.39 ft Top Width 6.38 ft Critical Depth 0.59 ft Critical Slope 0.02799 ft/ft Velocity 1.66 ft/s Velocity Head 0.04 ft Specific Energy 0.84 ft Froude Number 0.46 Flow Type Subcritical GVF Input Data Downstream Depth 0.00 ft Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 ft Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 0.80 ft Critical Depth 0.59 ft Channel Slope 0.54 % Critical Slope 0.02799 ft/ft Design Point 13 Swale_AB 3/13/2017 5:01:36 PM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 1of1Page 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 9+5010+0011+0011+50 (4933.2) 4934.10 24'' RCP 16.65 LF @ 0.20% STA=10+16.65 INLET A2-1 2'X2' AREA INLET TBC=4933.13 INV OUT (24" E)=4928.46 DEPTH=4.67 STA=11+73.36 (STORM A) STA=10+00.00 STORM A2 SDMH A2 5'Ø FLAT TOP MH RIM=4934.10 INV IN (18" N)=4928.62 INV IN (24" W)=4928.42 INV OUT (24" S)=4928.42 DEPTH=5.67 PROPOSED GROUND EXISTING GROUND 4928.69 4928.62 4928.62 4928.62 15.78 LF @ 0.44% 4910 4915 4920 4925 4930 4935 4940 4910 4915 4920 4925 4930 4935 4940 9+0010+0011+0012+0013+0014+00 PROPOSED GROUND EXISTING GROUND 100 YR HGL (4932.6) 4928.00 (4933.0) 4933.77 (4933.2) 4933.97 (4932.8) 4934.14 (4933.1) 4934.15 (4933.3) 4933.65 PROPOSED GROUND EXISTING GROUND STA=10+00.00 FES A 24" FES INV IN (24" NE)=4928.01 24'' RCP 55.23 LF @ 0.20% STA=10+55.23 SDMH A1 5'Ø FLAT TOP MH RIM=4934.21 INV IN (24" N)=4928.19 INV OUT (24" SW)=4928.12 DEPTH=6.09 24'' RCP 118.13 LF @ 0.20% STA=10+00.00 (STORM A2) STA=11+73.36 STORM A SDMH A2 5'Ø FLAT TOP MH RIM=4934.10 INV IN (18" N)=4928.62 INV IN (24" W)=4928.42 INV OUT (24" S)=4928.42 DEPTH=5.67 18'' RCP 58.66 LF @ 0.20% STA=12+32.02 INLET A3 5' CDOT TYPE R INLET TBC=4933.62 INV IN (18" NW)=4928.74 INV OUT (18" S)=4928.74 DEPTH=4.88 STA=12+62.50 INLET A4 5' CDOT TYPE R INLET TBC=4933.68 INV IN (18" NW)=4928.80 INV OUT (18" SE)=4928.80 DEPTH=4.88 18'' RCP 33.72 LF @ 0.20% STA=12+96.32 AREA INLET A5 2'X2' AREA INLET TBC=4933.77 INV OUT (18" SE)=4928.87 DEPTH=4.90 18'' RCP 30.48 LF @ 0.21% STA=12+55.22 TOP=4924.50 SANITARY CROSSING STA=12+43.63 TOP=4927.10 WATER CROSSING STA=11+21.36 INV=4925.28 SANITARY CROSSING STA=11+07.96 TOP=4926.54 WATER CROSSING STA=12+86.45 INV=4924.76 SANITARY CROSSING 2.9' COV. 2.9' COV. 18" MIN. 18" MIN. 32.33 LF @ 0.12% 118.91 LF @ 0.38% 34.98 LF @ 0.57% 56.28 LF @ 0.37% 54.13 LF @ 0.09% 4928.62 4928.62 4928.62 4928.83 4928.83 4929.03 4929.03 4929.07 4928.174928.17 4928.12 # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 08/31/1509.11.15 STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN A2 10+00.00 10+16.65 50 5 KEYMAP E. VINE DR. S. TIM BERLINE RD. TIMBERVINE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN A 10+00.00 12+96.32 50 5 LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES MAY NOT BE SHAPED UNLESS OTHERWISE NOTED. REFER TO PLAN VIEW FOR SHAPED MANHOLES. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS10 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER AND STORM. 12. SEE SHEET EX01 FOR EXISTING BOUNDARY CORNER COORDINATES. T S E SAN WTR GAS PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING TELEPHONE PROPOSED ELECTRIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS 8" INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: MARCH 29, 2016 1 04/12/2016 Record Drawings JEP 4910 4915 4920 4925 4930 4935 4940 4945 4910 4915 4920 4925 4930 4935 4940 4945 9+50 10+00 11+00 12+00 12+50 100 YR HGL STA=10+00.00 FES B 24" FES INV IN (24" E)=4927.01 24'' RCP 50.92 LF @ 0.35% STA=10+50.95 INLET B1 5' CDOT TYPE R INLET TBC=4931.98 INV IN (24" E)=4927.19 INV OUT (24" W)=4927.19 DEPTH=4.79 STA=11+00.95 INLET B2 5' CDOT TYPE R INLET TBC=4931.98 INV IN (24" E)=4927.37 INV OUT (24" W)=4927.37 DEPTH=4.61 24'' RCP 79.87 LF @ 0.35% STA=11+80.82 FES B3 24" FES INV OUT (24" W)=4927.65 24'' RCP 50.00 LF @ 0.36% STA=10+62.93 TOP=4925.48 WATER CROSSING STA=10+88.95 INV=4922.91 SANITARY CROSSING (4932.9) 4926.96 (4932.4) 4932.06 (4932.6) 4932.49 (4932.4) 4933.06 2.5' COV. 18" MIN. PROPOSED GROUND EXISTING GROUND PROPOSED GROUND EXISTING GROUND 2.7' COV. 4926.98 4927.684927.68 4927.72 4927.72 4927.94 80.25 LF @ 0.27% 53.52 LF @ 0.07% 48.49 LF @ 1.44% 4910 4915 4920 4925 4930 4935 4940 4910 4915 4920 4925 4930 4935 4940 9+0010+0011+0011+50 100 YR HGL 2.0' COV. 18" MIN. STA=10+35.00 TOP=4923.42 WATER CROSSING STA=10+00.00 INLET SO3-2 5' CDOT TYPE R INLET TBC=4928.98 INV OUT (24" W)=4925.16 DEPTH=3.82 STA=10+25.00 (STORM SO3) STA=10+25.00 STORM SO3 SDMH SO3 4'Ø FLAT TOP MH RIM=4929.95 INV IN (24" N)=4925.04 INV IN (24" E)=4925.04 INV IN (24" W)=4925.04 INV OUT (24" S)=4925.04 DEPTH=4.91 24'' RCP 25.00 LF @ 0.50% STA=10+50.00 INLET SO3-1 5' CDOT TYPE R INLET TBC=4928.98 INV OUT (24" E)=4925.16 DEPTH=3.82 24'' RCP 25.00 LF @ 0.50% STA=10+15.91 INV=4919.88 SANITARY CROSSING PROPOSED GROUND EXISTING GROUND (4931.1) 4928.98 (4931.7) 4928.98 4925.10 4925.10 4925.10 4925.10 4925.53 4925.50 27.48 LF @ 1.46% 26.81 LF @ 1.60% # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 08/31/1509.11.15 STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN SO3 10+00.00 10+50.00 50 5 KEYMAP E. VINE DR. S. TIM BERLINE RD. TIMBERVINE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN B 10+00.00 11+80.82 50 5 LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES MAY NOT BE SHAPED UNLESS OTHERWISE NOTED. REFER TO PLAN VIEW FOR SHAPED MANHOLES. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS10 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER AND STORM. 12. SEE SHEET EX01 FOR EXISTING BOUNDARY CORNER COORDINATES. T S E SAN WTR GAS PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING TELEPHONE PROPOSED ELECTRIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS 8" 1 04/12/2016 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: MARCH 29, 2016 4910 4915 4920 4925 4930 4935 4940 4945 4910 4915 4920 4925 4930 4935 4940 4945 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0021+0021+50 18" MIN. 100 YR HGL 2.7' COV. STA=10+00.00 FES SO1 24" FES INV IN (24" NW)=4924.67 STA=11+20.06 SDMH SO2 4'Ø FLAT TOP MH TBC=4930.31 INV IN (24" N)=4924.91 INV OUT (24" SE)=4924.91 DEPTH=5.40 24'' RCP 64.08 LF @ 0.20% 24'' RCP 372.27 LF @ 0.20% STA=15+56.42 SDMH SO4 4'Ø FLAT TOP MH RIM=4932.03 INV IN (24" N)=4925.78 INV OUT (24" S)=4925.78 DEPTH=6.25 24'' RCP 456.36 LF @ 0.20% STA=20+12.78 SDMH SO5 4'Ø FLAT TOP MH RIM=4933.08 INV IN (24" W)=4926.70 INV OUT (24" S)=4926.70 DEPTH=6.38 24'' RCP 90.84 LF @ 0.20% STA=21+03.61 POND B OUTLET STRUCTURE OUTLET STRUCTURE TBC=4929.13 INV OUT (24" E)=4926.88 DEPTH=2.25 24'' RCP 120.06 LF @ 0.20% STA=10+25.00 (STORM SO3) STA=11+84.14 STORM OUTLET SDMH SO3 4'Ø FLAT TOP MH RIM=4929.95 INV IN (24" N)=4925.04 INV IN (24" E)=4925.04 INV IN (24" W)=4925.04 INV OUT (24" S)=4925.04 DEPTH=4.91 STA=20+26.40 TOP=4924.98 WATER CROSSING STA=11+00.68 INV=4919.65 SANITARY CROSSING STA=10+28.25 INV=4919.09 SANITARY CROSSING PROPOSED GROUNDEXISTING GROUND (4925.0) (4931.1) 4930.30 (4931.1) 4929.98 (4931.0) 4930.74 (4931.3) 4931.24 (4931.2) 4931.74 (4930.9) 4932.24 (4931.6) 4932.74 (4932.2) 4933.23 (4932.5) 4933.71 (4932.3) 4933.19 (4932.8) 4929.56 (4931.0) 4930.46 (4931.5) 4930.06 (4931.0) 4930.35 (4931.1) 4930.99 (4931.3) 4931.49 (4931.1) 4931.99 (4931.4) 4932.49 (4931.9) 4932.99 (4932.6) 4933.49 (4932.4) 4933.61 (4932.5) 4932.91 PROPOSED GROUND EXISTING GROUND 4926.94 4926.874926.87 4926.144926.14 4925.10 4925.10 4924.714925.10 4925.10 452.77 LF @ 0.16% 86.80 LF @ 0.08% 62.25 LF @ 0.39%116.24 LF @ 0.13% 4924.864924.86 378.26 LF @ 0.27% # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: SPHLV0001.01 09/11/2015 TIMBERVINE HOLDINGS, LLC. 4801 GOODMAN RD. TIMNATH, CO 80547 08/31/1509.11.15 STA: SCALE: H: 1"=V: 1"= toSTORM OUTLET 10+00.00 21+03.61 50 5 KEYMAP E. VINE DR. S. TIM BERLINE RD. TIMBERVINE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES MAY NOT BE SHAPED UNLESS OTHERWISE NOTED. REFER TO PLAN VIEW FOR SHAPED MANHOLES. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS10 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER AND STORM. 12. SEE SHEET EX01 FOR EXISTING BOUNDARY CORNER COORDINATES. T S E SAN WTR GAS PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING TELEPHONE PROPOSED ELECTRIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS 8" 1 04/12/2016 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY STEWART AND ASSOCIATES DATED: MARCH 29, 2016 Project Description Friction Method Manning Formula Solve For Full Flow Capacity Input Data Roughness Coefficient 0.013 Channel Slope 0.0008 ft/ft Normal Depth 2.00 ft Diameter 24 in Discharge 6.40 ft³/s Results Discharge 6.40 ft³/s Normal Depth 2.00 ft Flow Area 3.14 ft² Wetted Perimeter 6.28 ft Hydraulic Radius 0.50 ft Top Width 0.00 ft Critical Depth 0.90 ft Percent Full 100.0 % Critical Slope 0.00469 ft/ft Velocity 2.04 ft/s Velocity Head 0.06 ft Specific Energy 2.06 ft Froude Number 0.00 Maximum Discharge 6.88 ft³/s Discharge Full 6.40 ft³/s Slope Full 0.00080 ft/ft Flow Type SubCritical GVF Input Data Downstream Depth 0.00 ft Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 ft Profile Description Profile Headloss 0.00 ft Average End Depth Over Rise 0.00 % International Blvd Outfall Pipe_AB at 0.008 ft/ft 3/14/2017 9:17:50 AM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page GVF Output Data Normal Depth Over Rise 100.00 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.00 ft Critical Depth 0.90 ft Channel Slope 0.0008 ft/ft Critical Slope 0.00469 ft/ft International Blvd Outfall Pipe_AB at 0.008 ft/ft 3/14/2017 9:17:50 AM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page Project Description Friction Method Manning Formula Solve For Full Flow Capacity Input Data Roughness Coefficient 0.013 Channel Slope 0.0013 ft/ft Normal Depth 2.00 ft Diameter 24 in Discharge 8.16 ft³/s Results Discharge 8.16 ft³/s Normal Depth 2.00 ft Flow Area 3.14 ft² Wetted Perimeter 6.28 ft Hydraulic Radius 0.50 ft Top Width 0.00 ft Critical Depth 1.02 ft Percent Full 100.0 % Critical Slope 0.00491 ft/ft Velocity 2.60 ft/s Velocity Head 0.10 ft Specific Energy 2.10 ft Froude Number 0.00 Maximum Discharge 8.77 ft³/s Discharge Full 8.16 ft³/s Slope Full 0.00130 ft/ft Flow Type SubCritical GVF Input Data Downstream Depth 0.00 ft Length 0.00 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.00 ft Profile Description Profile Headloss 0.00 ft Average End Depth Over Rise 0.00 % International Blvd Outfall Pipe_AB at 0.0013 ft/ft 3/14/2017 9:16:07 AM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page GVF Output Data Normal Depth Over Rise 100.00 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.00 ft Critical Depth 1.02 ft Channel Slope 0.0013 ft/ft Critical Slope 0.00491 ft/ft International Blvd Outfall Pipe_AB at 0.0013 ft/ft 3/14/2017 9:16:07 AM Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03] 27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page