HomeMy WebLinkAboutSite Certifications - 10/01/2021 (4)8/16 Page 1
OVERALL SITE and DRAINAGE CERTIFICATION
Commercial, Multi-Family and Subdivision Certification Form and Checklist
Project Name:
Date:
Building Permit Numbers:
(Commercial or multi-family)
Per the requirement in Fort Collins Stormwater Criteria Manual (FCSCM) Volume 1, Section 6.11, please fill in
all applicable items in this Certification Form for Commercial, Multi-Family and Overall Single Family sites.
NOTE: several items must be verified during construction. A copy of the approved grading plan must be
submitted with the as-built grading plan. (As-built elevations must be written in red next to the approved
elevations.)
•Use “Yes” for items completed as described.
•Use “N/A” for items that are not applicable to the site being certified.
•If any blanks are “No,” attach an explanation referencing the item number below.
Attach an explanation or description of the as-built condition for any items listed or for anything not listed but
shown on the approved construction plans.
Provide an as-built redline or Mylar drawing with the following:
I.Water Quality and Quantity Detention Basin Certification - FCSCM Vol.2, Ch.10
For multiple detention basins on a site, provide the following for each basin separately:
A. Volume: As-built topographic verification is attached at 1-foot (or less) contour intervals and
volume verification calculations for the water quality capture volume and the 100-year detention storage
volume.
1. Detention basin topography was prepared by a professional land surveyor registered in the state
of Colorado.
2.Both proposed and as-built contours are shown on the same plan sheet (dashed lines for
proposed and solid lines for as-built).
3.All critical spot elevations as shown on the approved construction plans have been verified and
the as-built elevations are shown on the plan sheet.
4.Stage-storage-discharge tables are provided on a separate document.
5.Verification that designed drain time is in compliance with Colorado Revised Statute § 37-92-
602(8) is attached and has been uploaded to the Statewide Compliance Portal
(tinyurl.com/COCompliancePortal) for approval. Uploaded documents must include:
a.The cover sheet from the approved drainage report
b.The stamped certification page from the approved drainage report
c.As-built topographic survey
d.Stamped certification page from the Overall Site & Drainage Certification
e.PDF output from the Stormwater Detention and Infiltration Design Data Speadsheet
Brookfield Second Replat
September 20, 2021
N/A
N/A
N/A
N/A
N/A
N/A
City of Fort Collins Approved Plans Approved by: Date:
Grading/Stormwater Certification Accepted
(Certificate of Occupancy Released)
Accepted by:
Date :
☐ Escrow was held for CO and is now released
Grading/Stormwater Plan Accepted
(Building Permit Released)
Accepted by:
Date :
Utility (Water/Sewer) Plan Approved
(Building Permit Released)
Approved by:
Date :
Fort Collins Utilities R edlines
Please contact me to discuss re visions
or questions prior to resubmitting.
dmogen@fcgov.com or 970-305-7944
Reviewed by:
Date :
we
Dan Mogen
10/01/2021
4
8/16 Page 2
B.Water Quality and Quantity Detention Basin Grading: Attached is as-built verification that there is
a minimum 2% positive fall into the concrete trickle pans or flow-line(s) from all areas in the bottom of
the detention pond. If there is a “soft pan” in the flow-line, all areas still must meet the minimum 2%
grade requirement.
1.Low Flow: Choose one of the following detention basin low flow options as applicable:
a. Turf swale for low flow path in detention basin.
There is a minimum 2% grade in the flow-line(s) of the detention basin. The flattest as-built grade
is .
b.Concrete pan for low flow in detention basin.
There is a concrete pan installed that meets the grades as shown on the approved construction
plans. (Show as-built spot elevations.)
c.Soft pan for low flow in detention basin.
•Verify and document the soft pan material gradation, trench width and depth - to be verified
during construction by engineer. Picture documentation is preferred or engineer’s statement of
visual inspection and compliance. (Choose one below.)
o There is a soft pan with an underdrain installed that meets the design on the approved
construction plans. (Show the underdrain grades, bedding material, geotextile, spot elevations,
bends, cleanouts, etc.)
o There is soft pan installed without an underdrain but there is a type A or B soil. The soil
type must be documented by supplying verification from a registered professional geotechnical
engineer.
NOTE: Spot elevations are to be within 0.2 ft. +/-.
2. Side Slopes: The as-built side slopes of the detention basin have been calculated and are shown.
Indicate the side slope with an arrow and a numerical value (e.g., 6.25:1). The maximum slope allowed
is 4:1. Small areas of 3:1 may be acceptable, but slopes steeper than 3:1 must be stabilized or re-
graded. Provide documentation if a variance was granted for steeper slopes during the design process.
3.Spillway Certification: The following items must be field verified:
a.The location of the spillway is indicated on the as-built plan.
b.The width of the spillway is indicated on the as-built plan.
c.The elevation(s) of the spillway is shown on the as-built plan.
d.A concrete ribbon defines the location and grade of the spillway.
e.There is downstream scour protection in the spillway as per the construction plans. Indicate
type: (riprap size “D50” gradation and bedding type, geotextile, buried
riprap with inches of bury, etc.).
f.There are no obstructions in the spillway, such as trees, bushes, sidewalks, landscape
features, rocks, etc.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8/16 Page 3
4.Outlet Structure Certification
a.The orifice plate for the approved release rate is installed with the correct size and location of
the orifice.
b.The orifice plate for the water quality outlet is installed with the correct hole size, number of
rows and columns of holes.
c.The bottom hole on both the water quality and quantity outlets are at the bottom of the plate
so no water ponds in front of the plate.
d.The well screen is the correct material and is installed as shown on the construction plans.
e.100-year overflow grate elevation is . (Elev. A on detail D-46)
f.The top elevation of the water quality capture volume is . (Elev. B on detail
D-46)
g.Overflow grate is made of the correct material, has the correct bar spacing, is hinged at the
top and bolted at the bottom.
h.The bottom of the outlet box has no obstructions or misalignments that will cause it to retain
runoff water and is sloped at 2% towards outlet.
II.Channels/Swales - FCSCM Vol.1, Ch.7, Sect.3&4
A. Capacity: The as-built capacity of all the major channels and swales has been verified. They meet
or exceed capacity requirements shown in the approved drainage study for this project.
1.All swales are located within the drainage easements as shown on the construction plans.
2.Longitudinal slopes and side-slopes (cross-sections) have been verified. Design criteria requires
longitudinal slopes of 2% min. (on vegetated swales) and side-slopes no steeper than 4:1. If these
criteria are not met, the certification engineer will write a justification and propose mitigation for each
instance or have the issues corrected. If variances to these criteria have previously been approved and
are shown on the construction plans, no justification is needed.
3.As-built spot elevations on channels/swales are shown that correspond to spot elevations
shown on the approved construction plans.
4.All permanent erosion control measures are installed as shown on the approved construction
plans (e.g., drop structures, riprap, TRMs, etc.). (Include pictures and verification of the materials used
as part of this verification.)
5.All pans, curbs, storm pipes or other appurtenances appropriately tie into each other in the
system. (Pictures at tie-in points suggested.)
6.The minimum freeboard is provided for all channels and swales as shown on the approved
construction plans or as identified in the approved drainage study. (Show the freeboard provided on
the cross-sections as on the construction plan set or attached as separate documentation.)
7.The low flow portion of all channels or swales is clear of obstructions. (No landscaping, trees,
shrubs, sod, etc. infringe on the low flow portion of channels or swales.)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Yes
Yes
N/A
N/A
N/A
8/16 Page 4
III.Storm Pipes (aka storm drains) - FCSCM Vol.1, Ch.6, Sec. 4
A. Storm Drain Pipe Capacity: The as-built capacity of all pipes installed on this project has been
verified and meets or exceeds the capacity requirements shown in the approved drainage study for this
project.
1.All storm drain pipe sizes and materials have been verified and are in conformance with the
approved construction plans. (Indicate on the plan and profile sheets that they have been verified.)
Material and size substitutions must be approved prior to installation. If a pipe size or material was
changed during construction, the certification engineer must attach the approval documents or supply
them with this certification. Approval documents must include a calculation documenting the capacity
equivalency (equal or greater) of the substituted size.
2.The longitudinal slope of the pipe is as shown on the approved construction plans. The
acceptable minimum slope is 0.4%. All slopes flatter than the designed slope on the construction plans
must be justified with capacity calculations on an attached sheet.
3.The as-built invert elevations have been verified and are shown on the plan and profile sheets of
the approved construction plans.
B.Storm Drain Pipe Installation Requirements: All pipes are installed in accordance with the
approved construction plans.
1.The minimum cover requirements for all pipes have been met as shown on the approved
construction plans. These will be called out in critical locations.
2.All encasements and clearances as specified on the approved construction plans have been met.
3.Any specific joint types or construction methods specified on the approved construction plans
have been met. (List on a separate sheet and attach to this certification.)
IV.Concrete Pans - FCSCM Vol.1, Ch.7, Sec.4.1.3.4
A. Construction/Installation: All concrete pans have been constructed in accordance with the
approved construction plans.
1.The concrete pans are the correct size/width as shown on the approved construction plans.
2.The longitudinal slopes of the pans are as shown on the approved construction plans. The
certification engineer must justify or mitigate longitudinal slopes less than the minimum of 0.4% unless
a flatter slope was approved and is shown on the approved construction plans. Provide mitigation or
justification by separate document.
3.The cross-section of the pan is as shown on the construction plans. (Specifically, the pan cross-
section is “V” shaped and meets the side slope shown on the detail.)
4.The concrete pans are a minimum of 6 inches thick without reinforcement and a minimum of 4
inches thick with a minimum of 6X6-W14xW14 reinforcement per detail D20B and D20C. (Provide
documentation of the reinforcement used if different than shown on the details or on the approved
construction plans.)
5.The spot elevations shown on the concrete pan(s) have been verified and are shown on the as-
built drawings.
One section of concrete pan in northwest corner of site has settled to 0.1% slope
There is no documentation on how they were built
One section of concrete pan in northwest corner of site has settled to 0.1% slope
but there is no observable standing water to appears to still be functioning.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
No
Yes
N/A
Yes
8/16 Page 5
V. Storm Drain Inlets - FCSCM Vol.1, Ch.6, Sec. 3
A. Construction/Installation: All storm drain inlets have been constructed in accordance with the
approved construction plans.
1.The size and type of inlets are consistent with the inlets shown on the approved construction
plan. Indicate by writing “Verified” on each inlet on the plan sheet or list on a separate document the
inlet number(s), type and size (length). If the inlet installed is other than the one on the approved
construction plan detail sheet, provide the name and source of the detail with justification for equal or
better capacity.
2.The size of the inlet opening is consistent with the approved detail. (Check height and width.)
3.The elevation of the grate (if applicable) is at the elevation shown on the street profile or as
indicated by a spot elevation on the construction plans.
4.The as-built invert elevations of all pipes entering and leaving the inlet are shown on the plan
and profile sheets within construction tolerance of 0.2 feet. If substantially different, provide
justification and capacity calculations to show the capacity is not affected or propose mitigation.
5.The as-built size of the inlet box is as shown on the construction plans or an explanation or
justification is attached.
6.All Type C, R, 13 and 16 inlet covers are stenciled or stamped with the following (or an
equivalent) designation: NO DUMPING – DRAINS TO POUDRE RIVER.
VI.Culverts - FCSCM Vol.2, Ch.9
A. Construction/Installation: All culverts have been constructed and/or installed in accordance with
the approved construction plans.
1.All culvert sizes have been verified as indicated on the as-built construction plans as correct.
2.The culvert material type for all culverts installed is as on the approved construction plans and is
indicated on the as-built plans.
3.The as-built invert “in and out” elevations have been verified and are indicated on the as-built
construction plans.
4.The culvert headwalls or wing walls have been installed as shown on the approved construction
plans. Headwalls or wing walls may be needed in the as-built conditions onsite if the slopes adjacent to
the culvert are greater than 4:1. Please note areas needing stabilization in the certification narrative.
An alternative to consider is a turf reinforcement mat (TRM).
VII.Sub-Drains
A. Construction/Installation: All sub-drains shown on the construction plans have been installed in
accordance with those plans. Sub-drains installed with the sanitary sewer are to be verified on the
sanitary sewer plan and profile sheets of the construction plans. (NOTE: Indicate any sub-drains installed
after the plans were approved on the as-built plans.)
1.The size of the sub-drains are as approved on the construction plans and are indicated on the as-
built plans.
2.The type of sub-drain, in particular the perforated and non-perforated sections of the drain, are
as indicated on the approved construction plans.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
N/A
N/A
N/A
Yes
Yes
Yes
8/16 Page 6
3.The cover requirements per the construction plans are provided.
4.The cleanouts have been installed at the locations shown on the construction plans and are
accessible for cleaning. (Cleanouts can be buried a maximum of 6 inches deep with their locations
marked.)
5.The backfill materials for sub-drains are as shown on the approved construction plans. (This
includes the type, depth and width.)
6.The geo-textile liner completely wraps the sub-drain and the permeable backfill material unless
shown otherwise on the approved construction plans. (Sub-drain pipe wrapped in a sock filter material
is accepted only if approved prior to installation.)
VIII.Curb Cuts
A. Construction: All curb cut openings are constructed in accordance with the approved construction
plans.
1.The size (width) of the curb cut opening is as shown on the approved construction plans.
2.The curb cut openings tie into a downstream swale, pipe, or other appurtenances with a smooth
transition and there no obstructions such as riprap or sod impeding the flow downstream of the curb
cut.
IX.Sidewalk Culverts & Chases
A. Construction/Installation: All sidewalk culverts have been installed at the locations shown on the
approved construction plans.
1.The size (width and length) of the culverts are as shown on the approved construction plans.
2.The cover plate is a minimum 5/8-inch galvanized plate bolted to a galvanized angle iron per the
detail shown on the approved construction plans or per the City’s detail.
3.The sidewalk culvert invert “in and out” elevations have been verified and are indicated on the
as-built plans.
4.The sidewalk culvert opening is as shown on the approved construction plans or per the City’s
detail.
5.There is a smooth transition both on the inlet and outlet ends of the sidewalk culvert with no
obstructions such as riprap or sod impeding the flow into or out of the sidewalk culvert.
X. Site Grading
A. Construction: All common open spaces have been graded in accordance with the approved
construction plans.
1.The grading on all common open spaces bordering private lots has been verified as correct and
the as-built rear lot corner elevations have been shown on the as-built plans.
There is no documentation on how they were built
There is no documentation on how they were built
The sidewalk culverts into rain gardens are 2' wide instead of 4' wide, however, are only required to convey low flows and 2'
wide is sufficient for that purpose. Major flows bypass the rain garden and bioswales entirely.
See below
See documentation from contractor.
See documentation from contractor.
Yes
Yes
N/A
N/A
N/A
N/A
No
No
Yes
Yes
Yes
Yes
Yes
Yes
8/16 Page 7
2.The as-built contours for “overlot grading” are shown on the as-built construction plans for all
common open spaces, tracts, outlots, etc. If not in compliance, please attach a narrative describing the
situation for noncompliance and when it may be corrected. An escrow for overlot grading may be
required. (NOTE: Residential Lot Grading Certification is a separate process from this Overall Site
Certification. It is understood that residential lots will be brought to final grade once the foundation is
backfilled so they may be lower than the plan shows at this Overall Site Certification stage.)
3.All turf reinforcement mats (TRMs) have been installed as shown on the approved construction
plans and the slopes are stabilized.
XI.Riprap - FCSCM Vol.1, Ch.7, Sec.4.4.4.3
A. Construction: All riprap has been installed in the locations and sizes indicated on the approved
construction plans.
XII.Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7
A. Construction: All fabric has been installed in the locations and sizes indicated on the approved
construction plans.
1.All fabric was installed per the details on the approved construction plans.
XIII.Post-Construction Site Cleanup - FCSCM Vol.3, Ch.7
A. Construction: All construction debris and obstructions of any kind have been removed from
drainage paths.
1.All construction debris has been removed except in staging area(s).
2.All ruts have been smoothed out in all construction areas.
3.All areas needing reseeding have been identified and future stabilization goals have been
coordinated with the Erosion Control Inspector and in accordance with FCSCM Vol.2 Chapter 12. Note
the area needing stabilization in the narrative.
XIV.Certification of Other Permanent BMPs - FCSCM Vol.2, Ch.8, Sec.2 & FCSCM Vol.2, Ch.12
A.The construction of channel drop structures is in accordance with the approved plan both in
location, horizontal dimensions and cross-section.
XV.Certification of LID and Water Quality Facilities - FCSCM Vol.3, Ch.4
A.Attached are the During Construction Inspection Checklist for Low Impact Development (LID) and
other items to be verified during construction, along with pictures and other required documentation.
Site is now stabilized with vegetation
This could not be located by the contractor as construction occurred several years ago.Best available information provided by contractor
N/A
Yes
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
8/16 Page 8
XVI. Certification and Erosion Control Measures
A. All temporary erosion control measures shall be removed upon stabilization. If at the time of preparing
this certification there are any erosion control measures still remaining on the site, please note them in
the narrative and verify that they need to remain at this time. If in doubt as to the need for any control
measure, please consult with the Erosion Control Inspector at 970-221-6700.
XVII.Statement of Compliance
A. This certification is signed and stamped. By signing this form, the engineer(s) attests that he/she has
visited and observed the site, and to the best of his/her knowledge, the as-built conditions of the drainage
facilities are as described in the above form and in the enclosed as-built plans.
B.Failure to properly disclose all known information could result in the rejection of this certification and
prevent the release of any and all Stormwater Utility permit holds on Building Permits and/or Certificates
of Occupancy within this development.
XVIII.Signature and Stamp by a Colorado-Registered Professional Engineer
Engineer’s contact information:
Name:
Email:
Phone:
Company:
Address:
PE Stamp
7/14/219/20/21
Daniel J. Weber
danny@northernengineering.com
(970)-568-5418
Northern Engineering Services
301 N. Howes St., Suite 100
Fort Collins, CO, 80521
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+0012+0013+0014+0015+0016+0017+0018+00
8" WATER
STA.=15+37.98
TOP=4891.63
STA.=15+27.98
INV.= 4888.59
8" PVC SANITARY
CONTRACTOR TO
VERIFY LOCATION PRIOR
TO CONSTRUCTION
1.72'
STA.=10+33.01
INV.= 4887.80
6" SANITARY
SERVICE
(APPROXIMATE
LOCATION)
EXISTING
GROUND
PROPOSED
GRADE
37.94 LF
24" RCP
@ 1.68%
MH
A
2
ST
A
1
1
+
4
8
.
9
4
RI
M
4
8
9
6
.
3
±
IN
V
.
I
N
4
8
9
1
.
0
1
(
N
)
IN
V
.
I
N
4
8
9
1
.
4
3
(
W
)
IN
V
.
O
U
T
4
8
9
0
.
9
1
(
S
)
102.09 LF 24" RCP @ 0.41%
MH
A
3
ST
A
1
2
+
5
1
.
0
3
RI
M
4
8
9
6
.
8
±
IN
V
.
I
N
4
8
9
1
.
6
3
(
N
)
IN
V
.
I
N
4
8
9
2
.
1
3
(
E
)
IN
V
.
O
U
T
4
8
9
1
.
4
3
(
S
)
177.67 LF
18" RCP
@ 0.60%
MH
A
4
ST
A
1
4
+
2
8
.
7
0
RI
M
4
8
9
7
.
7
±
IN
V
.
I
N
4
8
9
2
.
8
0
(
N
)
IN
V
.
I
N
4
8
9
3
.
2
0
(
E
)
IN
V
.
O
U
T
4
8
9
2
.
7
0
(
S
)
89.28 LF
18" RCP
@ 0.60%
MH
A
5
ST
A
1
5
+
1
7
.
9
8
RI
M
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
3
.
3
3
(
W
)
IN
V
.
I
N
4
8
9
2
.
8
3
(
N
E
)
IN
V
.
O
U
T
4
8
9
3
.
3
3
(
S
)
47.34 LF
12" RCP
@ 0.60%
AR
E
A
I
N
L
E
T
A
6
w
/
S
N
O
U
T
ST
A
1
5
+
6
5
.
3
2
FL
.
E
L
4
8
9
8
.
7
±
IN
V
.
I
N
4
8
9
4
.
6
9
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
6
9
(
W
)
IN
V
.
I
N
4
8
9
6
.
5
0
(
S
)
IN
V
.
O
U
T
4
8
9
3
.
6
2
(
E
)
185.54 LF
12" HDPE
@ 0.60%
AR
E
A
I
N
L
E
T
A
7
ST
A
1
7
+
5
0
.
8
6
FL
.
E
L
4
9
0
0
.
1
±
IN
V
.
O
U
T
4
8
9
5
.
8
0
(
E
)
EX
M
H
A
1
ST
A
1
0
+
1
1
.
0
6
RI
M
4
8
9
5
.
7
±
IN
V
.
I
N
4
8
8
9
.
7
9
(
N
)
IN
V
.
I
N
4
8
8
9
.
5
1
(
W
)
IN
V
.
O
U
T
4
8
8
8
.
1
1
(
S
)
PUBLIC
STORM
SEWER
PRIVATE
STORM
SEWER
ROW
100-YR HGL
99.94 LF 24" RCP @ 0.38%
MH
A
1
.
5
ST
A
1
0
+
4
9
.
0
0
RI
M
4
8
9
5
.
8
±
IN
V
.
I
N
4
8
9
0
.
5
3
(
N
)
IN
V
.
O
U
T
4
8
9
0
.
4
3
(
S
)
TIE INTO EXISTING
STORM DRAIN
5-UNIT
CONDO
(TOWNHOME STYLE)
5-UNIT
CONDO
(TOWNHOME STYLE)
5-UNIT
CONDO
(TOWNHOME STYLE)
TO
W
N
H
O
M
E
6-UNIT
CONDO
(TOWNHOME STYLE)
G
G
G
E
E
E
E
E
G
E
G
E
E
G
E
E
G
G
G
EE
G
E
G
E G
S
S
W
UD
W
W
T T
TT
D
D
C.O.
C.O.
C.O.
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
BLDG 9 BLDG 8
BLDG 35
LOT 1
LOT 2
BLDG 10
51' ROW
30'
FL-FL
89.28 LF
18" RCP
@ 0.60%
MH A5
STA 15+17.98
N: 106304.03
E: 215183.01AREA INLET A6 w/ SNOUT
STA 15+65.32
N: 106305.18
E: 215135.69
185.54 LF
12" HDPE
@ 0.60%
AREA INLET A7
STA 17+50.86
N: 106306.85
E: 214950.15
SANITARY LINE A
SEE SHEET SS1
STORM DRAIN A5
SEE SHEET ST3
47.34 LF
12" RCP
@ 0.60%
STORM DRAIN A6
SEE SHEET ST3
6-UNIT
CONDO
(TOWNHOME STYLE)
6-
U
N
I
T
TO
W
N
H
O
M
E
6-UNIT
CONDO
(TOWNHOME STYLE)
G
G
G
G
G
E
E
E
E
E
E
E
E
E
G
G
G
G
E
E
E
E
G
G
EG
E G
S
W
S
W
S
W
W
W
W
W
W
W T
T
D
D
LOT 4
BLDG 36
BLDG 35
LOT 1
LOT 2
LOT 3
LOT 5
LOT 6
LOT 7
LOT 8
TRACT B
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
51' ROW
30'
FL-FL
MH A4
STA 10+00.00
N: 106214.77
E: 215180.84
88.09 LF 12" RCP @ 0.50%
AREA INLET A4-1
STA 10+88.09
N: 106212.64
E: 215268.91
STORM DRAIN A
SEE THIS SHEET
36.66 LF
8" PVC
@ 0.50%
MH A4-2
STA 11+26.37
N: 106201.05
E: 215305.20
101.85 LF
8" PVC
@ 0.50%
AREA INLET A4-3
STA 12+28.22
N: 106099.29
E: 215309.44
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+50 10+00 11+00 12+00 12+50
EXISTING
GROUND
PROPOSED
GRADE
88.09 LF
12" RCP
@ 0.50%
MH
A
4
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
7
.
7
±
IN
V
.
I
N
4
8
9
2
.
8
0
(
N
)
IN
V
.
I
N
4
8
9
3
.
2
0
(
E
)
IN
V
.
O
U
T
4
8
9
2
.
7
0
(
S
)
AR
E
A
I
N
L
E
T
A
4
-
1
ST
A
1
0
+
8
8
.
0
9
FL
.
E
L
4
8
9
7
.
8
±
IN
V
.
I
N
4
8
9
3
.
9
7
(
E
)
IN
V
.
O
U
T
4
8
9
3
.
6
4
(
W
)
PRIVATE
STORM
SEWER
PUBLIC
STORM
SEWER
ROW
AR
E
A
I
N
L
E
T
A
4
-
3
ST
A
1
2
+
2
8
.
2
2
FL
.
E
L
4
8
9
8
.
0
±
IN
V
.
O
U
T
4
8
9
4
.
6
6
(
N
)
101.85 LF
8" PVC
@ 0.50%
MH
A
4
-
2
ST
A
1
1
+
2
6
.
3
7
RI
M
4
8
9
8
.
2
±
IN
V
.
I
N
4
8
9
4
.
1
5
(
S
)
IN
V
.
O
U
T
4
8
9
4
.
1
5
(
W
)
36.66 LF
8" PVC
@ 0.50%
100-YR HGL
8" W8" W8" W8" W
15
"
S
S
8"
W
12" SS 12" SS12" SS12" SS12" SS12" SS
H2
O
TOWNHOME
6-
U
N
I
T
CO
N
D
O
(T
O
W
N
H
O
M
E
S
T
Y
L
E
)
(T
O
W
N
H
O
M
E
S
T
Y
L
E
)
(T
O
W
N
H
O
M
E
S
T
Y
L
E
)
TOWNHOME
GGGGGGGG EEEEEEEE
EEEEEEEEE GGGGGGGGGGG
G
E
EE
EG
G
E
G
Pe
r
P
h
a
s
e
1
R
e
c
o
r
d
D
r
a
w
i
n
g
0
1
/
2
0
0
3
:
St
o
r
m
L
i
n
e
b
u
i
l
t
t
o
t
h
i
s
6
'
M
H
3
D
;
s
t
o
r
m
li
n
e
b
u
i
l
t
f
r
o
m
t
h
i
s
M
H
3
D
s
o
u
t
h
a
n
d
we
s
t
o
n
l
y
.
S W
S W
S
W
S
W WWWWWWWWW
Pe
r
T
S
T
U
t
i
l
i
t
y
P
l
a
n
C
-
3
1
2
o
f
4
6
:
wa
t
e
r
l
i
n
e
c
r
o
s
s
i
n
g
#
8
Pe
r
T
S
T
U
t
i
l
i
t
y
P
l
a
n
C
-
3
1
2
o
f
4
6
:
wa
t
e
r
l
i
n
e
c
r
o
s
s
i
n
g
#
1
0
=
d
e
f
l
e
c
t
e
d
T
D
D D
D
LO
T
4
BLDG 36
LO
T
1
LO
T
2
LO
T
3
LO
T
5
LO
T
6
LO
T
7
LO
T
8
LO
T
9
LO
T
1
0
LO
T
1
1
LO
T
1
2
NORTHERN LIGHTS DRIVE
EXISTING
STORM DRAINTIE INTO EXISTING
24" RCP STORM
STORM DRAIN A3
SEE SHEET ST3
STORM DRAIN A4
SEE THIS SHEET
37.94 LF
24" RCP
@ 1.68%
MH A2
STA 11+48.94
N: 105935.10
E: 215174.05
102.09 LF 24" RCP @ 0.41%
177.67 LF 18" RCP @ 0.60%
MH A4
STA 14+28.70
N: 106214.77
E: 215180.84
51
'
R
O
W
30
'
F
L
-
F
L
PROPERTY
CORNER
N:105937.28
E:215189.61
MH A3
STA 12+51.03
N: 106037.16
E: 215176.53
MH A1.5
STA 10+49.00
N: 105835.19
E: 215171.63
99.94 LF 24" RCP @ 0.38%
EXMH A1
STA 10+11.06
N: 105797.26
E: 215170.71
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
KEYMAP
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVER
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DEC
K
DEC
K
DECK
DECK
COVER
E
D
ENTR
Y
ENTR
Y
COVER
E
D
DECK
COVER
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTRY
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
ST1
PL
A
N
A
N
D
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
A
&
A
4
A.
M
o
r
s
e
A.
B
o
e
s
e
1"
=
5
0
'
14
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
LEGEND:
NOTES:
W
G
T
E/T/C
S
W
SS
E
F
STORM DRAIN LINE A
PROFILE SCALE:PROFILE SCALE:
STORM DRAIN LINE A4
PROFILE SCALE:
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
STORM A
STORM
A4
LI
N
E
MA
T
C
H
ST
A
14
+
5
0
LINE
MATCH STA
14+50
1
1
RECORD DRAWING
UD
STORM DRAIN A2
SEE THIS SHEET
90.00 LF 12" HDPE @ 0.50%
AREA INLET A2-2.1
STA 10+90.00
N: 106028.64
E: 215028.91
MH A2-2
STA 10+00.00
N: 105938.67
E: 215026.72
BLDG 12
BLDG 13
LO
T
9
LO
T
1
0
BLDG 14
D
C.O.
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+0012+0013+00
47.21 LF
30"x19" ELLIPTICAL RCP
@ 0.74%
100.17 LF 24" HDPE @
0
.
7
6
%
STA.=10+10.00
INV.= 4887.09
8" PVC SANITARY
8" WATER
LOWERING PER DETAIL 203
STA.=10+20.00
TOP=4889.80
18" MIN
EXISTING
GROUND
PROPOSED
GRADE
85.37 LF
12" HDPE
@ 0.50%
MH
A
2
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
6
.
3
±
IN
V
.
I
N
4
8
9
1
.
0
1
(
N
)
IN
V
.
I
N
4
8
9
1
.
4
3
(
W
)
IN
V
.
O
U
T
4
8
9
0
.
9
1
(
S
)
MH
A
2
-
2
ST
A
1
1
+
4
7
.
3
7
RI
M
4
8
9
7
.
9
±
IN
V
.
I
N
4
8
9
3
.
3
2
(
W
)
IN
V
.
I
N
4
8
9
3
.
3
2
(
N
)
IN
V
.
O
U
T
4
8
9
2
.
6
2
(
E
)
AR
E
A
I
N
L
E
T
A
2
-
3
ST
A
1
2
+
3
2
.
7
4
FL
.
E
L
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
5
.
9
8
(
W
)
IN
V
.
O
U
T
4
8
9
3
.
7
5
(
E
)
AR
E
A
I
N
L
E
T
A
2
-
1
ST
A
1
0
+
4
7
.
2
1
FL
.
E
L
4
8
9
6
.
6
±
IN
V
.
I
N
4
8
9
1
.
8
6
(
W
)
IN
V
.
I
N
4
8
9
4
.
5
6
(
N
)
IN
V
.
O
U
T
4
8
9
1
.
7
8
(
E
)
PUBLIC
STORM
SEWER
PRIVATE
STORM
SEWER
ROW
100-YR HGL
12
"
S
S
12
"
S
S
H2O
S
W
UD UD
W
MH A2
STA 10+00.00
N: 105935.10
E: 215174.05
AREA INLET A2-3
STA 12+32.74
N: 105940.74
E: 214941.38 STORM DRAIN A
SEE SHEET ST1
AREA INLET A2-1
STA 10+47.21
N: 105936.24
E: 215126.86
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
47.21 LF
30"x19" ELLIPTICAL RCP
@ 0.74%
85.37 LF
12" HDPE
@ 0.50%
100.17 LF 24" HDPE @ 0.76%
MH A2-2
STA 11+47.37
N: 105938.67
E: 215026.72
BLDG 12
BLDG 13
LOT 11
LOT 12
BLDG 14
DD
S
8"
W
12
"
S
S
BR
O
O
K
F
I
E
L
D
D
R
I
V
E
MH A2-2
BLDG 12
LOT 9
LOT 10
LOT 11
45° BEND W/ C/O A2-2.3
STA 12+12.82
N: 106040.31
E: 214908.07
45° BEND W/ C/O A2-2.2
STA 11+12.81
N: 106037.88
E: 215008.05
22.82 LF
8" PVC
@ 0.40%
100.01 LF 8" PVC @ 0.40%27.09 LF
8" PVC
@ 0.40%AREA INLET A2-2.1
STA 10+90.00
N: 106028.64
E: 215028.91
C.O.
C.O.
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+0012+0013+0014+0014+50
90.00 LF
12" HDPE
@ 0.50%
EXISTING
GROUND
PROPOSED
GRADE
27.09 LF
8" PVC
@ 0.40%
22.82 LF
8" PVC
@ 0.40%
100.01 LF
8" PVC
@ 0.40%
MH
A
2
-
2
ST
A
1
1
+
4
7
.
3
7
RI
M
4
8
9
7
.
9
±
IN
V
.
I
N
4
8
9
3
.
3
2
(
W
)
IN
V
.
I
N
4
8
9
3
.
3
2
(
N
)
IN
V
.
O
U
T
4
8
9
2
.
6
2
(
E
)
AR
E
A
I
N
L
E
T
A
2
-
2
.
1
ST
A
1
0
+
9
0
.
0
0
FL
.
E
L
4
8
9
7
.
4
±
IN
V
.
I
N
4
8
9
3
.
8
8
(
N
W
)
IN
V
.
O
U
T
4
8
9
3
.
7
7
(
S
)
45
°
B
E
N
D
W
/
C
/
O
A
2
-
2
.
2
ST
A
1
1
+
1
2
.
8
1
RI
M
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
3
.
9
7
(
W
)
IN
V
.
O
U
T
4
8
9
3
.
9
7
(
S
E
)
45
°
B
E
N
D
W
/
C
/
O
A
2
-
2
.
3
ST
A
1
2
+
1
2
.
8
2
RI
M
4
8
9
9
.
8
±
IN
V
.
I
N
4
8
9
4
.
3
7
(
N
W
)
IN
V
.
O
U
T
4
8
9
4
.
3
7
(
E
)
12
"
I
N
L
E
T
A
2
-
2
.
4
ST
A
1
2
+
3
9
.
9
1
FL
.
E
L
4
8
9
7
.
0
±
IN
V
.
I
N
4
8
9
4
.
4
8
(
N
E
)
IN
V
.
O
U
T
4
8
9
4
.
4
8
(
S
E
)
PRIVATE STORM SEWER
117.66 LF
4" PVC
@ 1.00%
C/
O
A
2
-
2
.
6
ST
A
1
3
+
7
6
.
3
9
RI
M
4
8
9
8
.
6
±
IN
V
.
O
U
T
4
8
9
5
.
8
4
(
S
)
18.82 LF
4" SLOTTED PVC
@ 1.00%
C/
O
A
2
-
2
.
5
ST
A
1
2
+
5
8
.
7
2
RI
M
4
8
9
7
.
2
±
IN
V
.
I
N
4
8
9
4
.
6
6
(
N
)
IN
V
.
O
U
T
4
8
9
4
.
6
7
(
S
W
)
100-YR HGL
2.24'
H2
O
H2
O
S
S
8" W8" W
HYD
WV
WV
WV
W
8" W8" W
12" SS12" SS12" SS
V.
P
.
12" INLET A2-2.4
STA 12+39.91
N: 106059.92
E: 214889.39
C/O A2-2.5
STA 12+58.72
N: 106075.78
E: 214899.51
18.82 LF
4" SLOTTED PVC
@ 1.00%
C/O A2-2.6
STA 13+76.39
N: 106193.42
E: 214897.06
117.66 LF
4" SLOTTED PVC
@ 1.00%
BROOKFIELD DRIVE
BLDG 11
TRACT A
BLDG 10
C.O.
C.O.
C.O.
C.O.
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
KEYMAP
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVER
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DEC
K
DEC
K
DECK
DECK
COVER
E
D
ENTR
Y
ENTR
Y
COVER
E
D
DECK
COVER
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTRY
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
ST2
PL
A
N
A
N
D
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
A
2
&
A
2
-
2
A.
M
o
r
s
e
A.
B
o
e
s
e
1"
=
5
0
'
15
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
STORM DRAIN LINE A2
PROFILE SCALE:PROFILE SCALE:
STORM DRAIN LINE A2-2
PROFILE SCALE:PROFILE SCALE:
STORM
A2-2, A2-2.1
STORM
A2
LEGEND:
NOTES:
W
G
T
E/T/C
S
W
SS
E
F
1
RECORD DRAWING
CT
V
X
S
W
12'' INLET A5-1
STA 10+55.01
N: 106329.42
E: 215231.81
6.28 LF
4" PVC
@ 0.40%
22.5° BEND W/ C/O A5-1-1
STA 10+06.28
N: 106334.09
E: 215227.60
43.53 LF
4" SLOTTED PVC
@ 0.40%
12'' INLET A5-1
STA 10+55.01
N: 106329.42
E: 215231.81
51
'
R
O
W
30
'
F
L
-
F
L
BLDG 35
STORM DRAIN A-5
SEE THIS SHEET
STORM DRAIN A
SEE SHEET ST1
C|O A5-1-2
STA 10+49.82
N: 106377.56
E: 215229.81
D
D
C.O.
C.O.
C.O.
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+2510+0011+00
43.53 LF
4" SLOTTED PVC
@ 0.40%
6.28 LF
4" PVC
@ 0.40%
EXISTING
GROUND
PROPOSED
GRADE
C|
O
A
5
-
1
-
2
ST
A
1
0
+
4
9
.
8
2
RI
M
4
8
9
6
.
9
±
IN
V
.
O
U
T
4
8
9
4
.
9
0
(
S
)
22
.
5
°
B
E
N
D
W
/
C
/
O
A
5
-
1
-
1
ST
A
1
0
+
0
6
.
2
8
RI
M
4
8
9
6
.
9
±
IN
V
.
I
N
4
8
9
4
.
7
3
(
N
)
IN
V
.
O
U
T
4
8
9
4
.
7
3
(
S
E
)
12
'
'
I
N
L
E
T
A
5
-
1
ST
A
1
0
+
5
5
.
0
1
FL
.
E
L
4
8
9
7
.
5
±
IN
V
.
I
N
4
8
9
2
.
5
6
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
7
0
(
N
W
)
IN
V
.
O
U
T
4
8
9
2
.
5
6
(
S
W
)
PRIVATE STORM SEWER
1.78'
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+50 10+00 11+00 11+50
55.01 LF
8" PVC
@ -0.50%
EXISTING
GROUND
PROPOSED
GRADE
6.04 LF
8" PVC
@ 0.50%
DR
Y
W
E
L
L
A
5
-
2
ST
A
1
0
+
6
1
.
0
5
GR
A
T
E
/
R
I
M
.
E
L
4
8
9
8
.
2
±
SU
M
P
4
8
8
3
.
1
2
IN
V
.
O
U
T
4
8
9
2
.
5
3
(
S
W
)
MH
A
5
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
3
.
3
3
(
W
)
IN
V
.
I
N
4
8
9
2
.
8
3
(
N
E
)
IN
V
.
O
U
T
4
8
9
3
.
3
3
(
S
)
12
'
'
I
N
L
E
T
A
5
-
1
ST
A
1
0
+
5
5
.
0
1
RI
M
4
8
9
7
.
5
±
IN
V
.
I
N
4
8
9
2
.
5
6
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
7
0
(
N
W
)
IN
V
.
O
U
T
4
8
9
2
.
5
6
(
S
W
)
PRIVATE
STORM
SEWER
PUBLIC
STORM
SEWER
ROW
ST
A
1
0
+
5
5
.
0
1
RI
M
4
8
9
7
.
5
±
S
S
W
S
UD
W
W
W
W
51' R
O
W
30' FL-
F
L
BLDG 35
LOT
1
LOT
2
12'' DRAIN BASIN A5-1
STA 10+55.01
N: 106329.42
E: 215231.81
STORM DRAIN A
SEE SHEET ST1
MH A5
STA 10+00.00
N: 106304.03
E: 215183.01
DRYWELL A5-2
STA 10+61.05
N: 106332.21
E: 215237.17
STORM DRAIN A-5-1
SEE THIS SHEET
STORM DRAIN A6
SEE THIS SHEET
55.01 LF
8" PVC
@ -0.50%
6.04 LF
8" PVC
@ -0.50%
D
D
D
C.O.
C.O.
C.O.
12
"
S
S
12
"
S
S
W
S
S
W
W
UD UD
W
W
W
W
W
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
SANITARY LINE A
SEE SHEET SS1
AREA INLET A3-1
STA 10+53.09
N: 106035.87
E: 215229.61
STORM DRAIN A
SEE SHEET ST1
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
BLDG 36
LOT 8
LOT 11
LOT 12
TRACT B
53.09 LF
12" RCP
@ 0.50%
MH A3
STA 10+00.00
N: 106037.16
E: 215176.53
D
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+50 10+00 11+00
53.09 LF
12" RCP
@ 0.50%
EXISTING
GROUND
PROPOSED
GRADE
MH
A
3
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
6
.
8
±
IN
V
.
I
N
4
8
9
1
.
6
3
(
N
)
IN
V
.
I
N
4
8
9
2
.
1
3
(
E
)
IN
V
.
O
U
T
4
8
9
1
.
4
3
(
S
)
AR
E
A
I
N
L
E
T
A
3
-
1
ST
A
1
0
+
5
3
.
0
9
FL
.
E
L
4
8
9
7
.
1
±
IN
V
.
I
N
4
8
9
5
.
0
0
(
E
)
IN
V
.
O
U
T
4
8
9
2
.
4
0
(
W
)
PRIVATE
STORM
SEWER
PUBLIC
STORM
SEWER
ROW
100-YR HGL
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+00
AR
E
A
I
N
L
E
T
A
6
w
/
S
N
O
U
T
ST
A
?
?
?
FL
.
E
L
4
8
9
8
.
7
±
IN
V
.
I
N
4
8
9
4
.
6
9
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
6
9
(
W
)
IN
V
.
I
N
4
8
9
6
.
5
0
(
S
)
IN
V
.
O
U
T
4
8
9
3
.
6
2
(
E
)
IN
L
E
T
A
6
-
1
ST
A
1
0
+
2
9
.
3
5
RI
M
4
8
9
8
.
0
±
IN
V
.
O
U
T
4
8
9
4
.
8
6
(
S
W
)
28.08 LF
12" RCP
@ 0.60%
100-YR HGL
EXISTING
GROUND
PROPOSED
GRADE
ST
A
1
0
+
0
0
.
0
0
2.68'
S
S
W
S
UD
W
W
W
W
51' R
O
W
30' FL-
F
L
LOT
1
LOT
2
LOT
3
STA 10+00.00
STORM DRAIN A
SEE SHEET ST1
INLET A6-1
STA 10+29.35
N: 106322.88
E: 215158.46
28.08 LF
12" RCP
@ 0.60%
D
D
C.O.AREA INLET A6 w/ SNOUT
STA ???
N: 106305.18
E: 215135.69
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
KEYMAP
COV
E
R
E
D
ENTR
Y
ENTR
Y
COVE
R
E
D
DECK
COV
E
R
E
DENTR
Y
COV
E
R
E
DENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DECK
DEC
K
DEC
K
COV
E
R
E
DENTR
Y
ENTR
Y
COVE
R
E
D
DECK
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DECK
DEC
K
DEC
K
COVE
R
E
D
ENTR
Y
ENTR
Y
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DEC
K
DECK
DEC
K
DEC
K
COVE
R
E
D
ENTR
Y
ENTR
Y
COVE
R
E
D
DEC
K
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENT
R
Y
COV
E
R
E
D
ENT
R
Y
DEC
K
DEC
K
DEC
K
DEC
K
COVE
R
E
D
ENTR
Y
ENT
R
Y
COVER
E
D
DECK
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENT
R
Y
DEC
K
DECK
DECK
DEC
K
COV
E
R
E
D
ENTR
Y
ENTR
Y
COVE
R
E
D
DECK
COV
E
R
E
D
ENT
R
Y
COV
E
R
E
D
ENT
R
Y
COVE
R
E
D
ENT
R
Y
DEC
K
DECK
DEC
K
DEC
K
ST3
PL
A
N
A
N
D
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
A
3
,
A
5
&
A
5
-
1
A.
M
o
r
s
e
A.
B
o
e
s
e
1"
=
5
0
'
16
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
PROFILE SCALE:
STORM
A3
STORM DRAIN LINE A5
PROFILE SCALE:
STORM
A5,
A5-1, A6
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
PROFILE SCALE:
STORM DRAIN LINE A3
LEGEND:
NOTES:
W
G
T
E/T/C
S
W
SS
E
F
STORM DRAIN LINE A6
PROFILE SCALE:
STORM DRAIN LINE A5-1
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
STORM DRAIN A-5
SEE THIS SHEET
CONTRACTOR TO INSTALL AND MAINTAIN
PLUG IN A5 & A5-1 ON NORTHEAST 8"
OUTFALL LINE DURING CONSTRUCTION.
PUMP AND LEGALLY DISPOSE OF
EFFLUENT, THEN REMOVE PLUG AS SOON
AS SITE IS ESTABLISHED
RECORD DRAWING
BR
O
O
K
F
I
E
L
D
D
R
I
V
E
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
LE FEVER DRIVE
UD UD UD UD
HYD
V.P.
LOD
LOD
LOD LOD LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LO
D
LO
D
LOD
LO
D
LOD
STORM DRAIN A
SEE SHEET ST1
STORM DRAIN A
SEE SHEET ST1
STORM DRAIN A5
SEE SHEET ST3
TRACT ETRACT E
BLDG 9 BLDG 8
BLDG 11 BLDG 36
GAR
GAR
LOT 1
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
TRACT A
BLDG 10
GAR
GAR GAR GAR GAR GAR GAR GAR GAR GAR
GAR
GAR
GAR
GAR
GAR
GAR
GAR
GAR
GAR
RAIN
GARDEN
CURB
4.5' WALK
4' WALK
4' WALK
4' WALK
4'
W
A
L
K
4'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.5' WALK
4.
5
'
W
A
L
K
4.5' WALK
BIO SWALE
WITH SOFT
BOTTOM
4.5' WALK
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
DRAINAGE
EASEMENT
DRAINAGE
EASEMENT
C/O
C/O
C/O
C/O
GRATE
INLET
97.04 FL
D
D
C.O.
C.O.
C.O.
C.O.
C.O.
C.O.
23
.
8
%
33.
7
%
25
.
4
%
23
.
9
%
2.1
%
10.4%
7.6%
7.8%
8.
5
%
3.
0
%
11
.
1
%
16
.
2
%
26.6%
13.7%
6.5%
19.4%
14.
4
%
14
.
1
%
15.6%
11.9%
17
.
5
%
8.4%
7.7%
11.0%
13.9%
16.8%
12.8
%
15
.
2
%
9.6
%
15
.
3
%
20.2
%
14
.
7
%
14.3%
13.8%
17.1%
15.8%
12
.
1
%
4.8%
9.
9
%
5.
3
%
10.9%
11.1%
2.3%
2.2%
1.6%
20.9%
12
.
2
%
20.5
%
24.3%
14.1
%
13
.
0
%
18.4%
9.3%
(??
?
)
2.6%
2.9%13.2%
7.3%
8.7%
4.2%
98
.
0
5
FL
97.
7
5
FL
97
.
2
5
FL
97
.
0
6
0.95FL
96.90
FL
FG=2.57
TF=3.24 FG=2.25
TF=2.92
FG=2.72
TF=3.39
FG=1.85
TF=2.52
ELEV=96.90
FG=1.67
TF=2.34
98.4
0
98.1
1
97.6
8
97.
6
2
97.4
6
99.1
8
99.8
6
1.58
1.31
98.9
3
99.6
0
0.36
1.60
98.5
2
0.24
0.28
99.9
9
99.7
2
99.4
4
99.1
6
98.8
6
98.7
4
98.4
4
98.1
6
0.12 98.6
6
96.9
5
0.33
0.50
98.7
8
97.9
4
FL
97.30
FL
99.
4
4
FL
98.
0
8
FL
0.31
FL
99.02
FL
99.8
6FL
99
.
7
5
FL
FRONT=1.02 FRONT=0.81 FRONT=0.50 FRONT=0.21 FRONT=99.97 FRONT=99.51 FRONT=99.35FRONT=0.81 FRONT=0.81 FRONT=0.81
0.9
6FL 1.18FL
1.30FL
0.71 1.20
1.11
0.8
4
FL
0.96
FL
0.7
4FL 0.2
7FL 0.7
4FL 0.2
5FL 0.5
2FL 0.3
0FL 98.8
5
0.78 0.580.761.011.671.64
0.5
5
0.7
8
0.7
6
0.6
1
0.4
3
0.4
3
0.4
0 0.3
1
0.3
1
99.
7
5
99
.
1
8
0.4
30.6
1
1.2
7
1.2
4
1.5
0
1.5
0 1.2
7 1.1
8 0.5
4
0.5
8
1.3
5
1.15
1.13
98.6
6
99.8
0
1.24
1.22
0.44 0.73 0.79
HP 0.64
0.46
0.25
0.24
0.44
0.46
0.34
1.331.541.01 0.88
1.28
1.33
1.73
1.421.21
0.6
4FL0.31
0.9
5
FL 1.2
1
FL 1.4
7
FL 1.0
0
FL 1.0
2
FL 0.5
9
FL
0.25
0.36
0.61
0.73
0.45
99.9
5
99.6
8
0.34
0.24 0.33 0.57 0.69 0.50
0.34
0.1
9
98.3
9
FL
0.2
4 99.
9
5
FL 0.4
9FL
0.6
7
0.63
0.15
0.04
99.9
3
99.8
2
0.1
3
0.0
2
99
.
8
1
99.7
5
FL
0.25
FL 0.88
99.
7
5
FL
0.48
0.4
8
FRONT=1.08 FRONT=0.91 FRONT=0.81 FRONT=0.81 FRONT=0.81
FR
O
N
T
=
9
9
.
4
0
FR
O
N
T
=
9
9
.
6
4
99.9
3
99.4
2
98.8
0
99.8
9
0.25
0.65
0.81
1.21
1.34
0.8
9
0.8
1
0.8
1
0.1
5
99.
8
3
99
.
5
3
99.5
0
FL
99.0
3
FL
99.3
9
FL
99.7
5
FL
0.22
FL
0.31
0.78
FL
0.87
FL
0.57
FL
0.28
FL
0.19
98.4
9
98.4
7
98.2
6
98.2
0
98.1
0
98.1
2
98.1
1
97.4
0FL
FR
O
N
T
=
9
8
.
4
2
FR
O
N
T
=
9
8
.
7
5
FR
O
N
T
=
9
9
.
2
5
FR
O
N
T
=
9
9
.
4
6
FR
O
N
T
=
9
9
.
5
0
FR
O
N
T
=
1
0
0
.
0
0
FR
O
N
T
=
0
.
0
5
FR
O
N
T
=
0
.
5
5
FR
O
N
T
=
0
.
5
8
0.16
99.9
2
99.7
6
98.9
1HP
1.12
97.5
5
97
.
5
3
0.08
99.2
0
98.8
5
98.8
5
98.
3
7
98.1
8
98.3
9HP
99
.
7
3
99
.
4
2
FRONT=98.92
98.
1
5
98.
0
8
97.9
8
97.9
6
97.8
3
97.7
5
97.6
3
97.5
5
97.4
2
97.4
0
98.7
2
FL
98.12
FL
99
.
2
2
99.
2
2
97.60
99.0
4
1.73 1.69
1.55 1.51
1.32 1.28 1.20 1.17
0.94 0.90
0.54
0.60 0.61
0.40 0.37 0.30 0.27
0.10 0.07
99.9
3
99
.
9
1
0.0
4
99
.
9
3
99.8
2
99.
7
2
FG=1.67
TF=2.34
FG=1.67
TF=2.34
FG=1.67
TF=2.34
FG=1.67
TF=2.34
FG=1.67
TF=2.34
99.2
0
99.9
1
0.17
FG=1.07
TF=1.74
1.16
FL
1.2
4FL
0.4
0
1.06
FL
0.50
99.8
9
FL
98.4
2
FL
99.2
2
FL
FG=0.88
STEM WALL=
1.55
FG=1.48
STEM WALL=
2.15
FG=1.27
STEM WALL=
1.94
FG=1.21
STEM WALL=
1.88
FG=1.54
STEM WALL=
2.21
FG=1.76
STEM WALL=
2.43
FG=1.66
STEM WALL=
2.33
FG=1.30
STEM WALL=
1.97
FG=1.01
STEM WALL=
1.68
FG=0.77
STEM WALL=
1.44
FG=1.07
TF=1.74
FG=99.93
STEM WALL=
100.60
FG=99.62
STEM WALL=
100.29
FG=0.22
STEM WALL=
0.89
FG=0.93
STEM WALL=
1.60
FG=0.93
STEM WALL=
1.60
FG=1.34
STEM WALL=
2.01
FG=99.73
STEM WALL=
100.40
97.52
FL
99.2
3FL
98.0
5
98
.
3
4
HP
FG=1.27
TF=1.94
99.8
8
FL
99.6
6
98.02
FL
0.53
98.9
4
HP
98.
1
4
98.5
1
99.6
1
99
.
7
1
99
.
0
5
99.0
6
98.8
4
98.75
98.6
198.70
98.93
98.
5
5
98.
4
6
98.5
798.48
99.
0
8
0.3
1
0.51
FL0.68
0.91
1.40
1.02
1.40
97.4
0
97.4
0
97.3
4
98.1
2
98.1
4
98.0
9
98.3
2
98.3
4
98.2
8
97.8
1
97.7
7
97.5
7
97.6
1
98.
2
4
(95
.
0
1
)
96.6
6
95.5595.9
3
97.71
97.7
4 96.8
1
98.2
0
96.9
0
96.9
0
99.13
98.
4
5
98.
5
7
98.6
6
98.6
6
98.5
5
98.
4
8
98.84
98.
3
6
99
.
6
7
FL
(??
?
)
95.71
FL
96.50
FL
96.79
FL
97.60
FL98.23
FL98.66
FL98.89
FL99.26
FL99.45
FL
99.54
FL
???
FL
1.3
7FL 1.5
2FL
1.1
2FL 1.4
2FL
1.2
2FL 0.9
5FL
1.1
5FL
1.4
0FL
1.2
1FL
1.0
1FL
98.3
2
FL
97.38
FL
98.5
7
98.6
9
98.8
2
98.4
3
98
.
1
6
0.33
0.24
0.15
0.25
0.12
0.22
0.2
2
99.8
3
0.120.03
0.25
99.0
3
99.7
3
98.4
1
99.4
9
98.1
7
99.3
0
98.9
4
98.9
0
99.2
2
97.9
1
98.6
7
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
G1
GR
A
D
I
N
G
P
L
A
N
R.
B
a
n
n
i
n
g
A.
B
o
e
s
e
1"
=
2
0
'
17
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVER
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DEC
K
DEC
K
DECK
DECK
COVER
E
D
ENTR
Y
ENTR
Y
COVER
E
D
DECK
COVER
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTRY
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
G1 G2
G4
LEGEND:
5013
PROPOSED CONTOUR 93
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED
LIMITS OF DISTURBANCE LOD
PROPOSED SPOT ELEVATION 33.43
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4.FINISHED GRADE ELEVATIONS DEPICTED HEREIN REPRESENT THE TOP LEVEL OF
FINISHED SURFACES, UNLESS OTHERWISE NOTED. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO ACCOUNT FOR DEPTH OF SOD, MULCH OR
OTHER LANDSCAPE SURFACE TREATMENTS TO ENSURE PROPER FINISHED GRADE
ELEVATIONS ARE ACHIEVED. THIS INCLUDES ACCOUNTING FOR TOPSOIL
AMENDMENTS FOR SEEDED AREAS AND OTHER LANDSCAPE/PLANTING PRACTICES
WHICH MAY AFFECT FINISHED GRADE.
5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YR STORM. FINISHED GRADE
ELEVATIONS AROUND BUILDINGS ARE SPECIFIED 4" BELOW FINISHED FLOOR.
WHERE ADDITIONAL SEPARATION IS REQUIRED FOR ISOLATION OF MATERIALS PER
BUILDING CODE, CONTRACTOR SHALL MAINTAIN MINIMUM GRADE AWAY FROM
FOUNDATIONS AS SHOWN ON THESE PLANS AND PER GEOTECHNICAL
RECOMMENDATIONS. FOUNDATION EXTENSIONS SUCH AS STEM WALLS OR
IMPERMEABLE MEMBRANES DESIGNED FOR PERMANENT UNDERGROUND USE
MUST BE INSTALLED AROUND FOUNDATIONS ACCORDING TO MANUFACTURERS
RECOMMENDATIONS. RECOMMENDED IMPERMEABLE MEMBRANE IS BITUTHENE
3000 OR APPROVED EQUAL.
6.ALL GARAGE DOWNSPOUTS DISCHARGING TO THE FRONT OF THE GARAGES SHALL
BE COORDINATED DURING CIVIL CONSTRUCTION. MIN 4" UNDERGROUND ROOF
DRAIN SERVICE LINES SHALL BE INSTALLED FROM ROOF DRAIN MAINS TO ALL SUCH
DOWNSPOUTS.
7.HABITAT BUFFER ZONE IS TO BE MAINTAINED IN A NATIVE LANDSCAPE. SEE
SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER
ZONE. HABITAT BUFFER ZONE IS BETWEEN THE LOT LINE AND EASTERN EDGE OF
PEDESTRIAN TRAIL.
NOTES:
PROPOSED STORM INLET
2.0%
PEDESTRIAN ACCESS RAMPS
(47.4
5
)
EXISTING SPOT ELEVATION
CURB & GUTTER
PROPOSED FIRE HYDRANT
PROPOSED ELECTRIC TRANSFORMER
LOT LINE
HIGH POINT HP
LOW POINT LP
FLOW LINE FL
EXISTING BRUSH LINE
EXISTING WATER SURFACE ELEVATION
TRAIL TR
TOP OF WALL TW
BOTTOM OF WALL BW
G3
MATCHLINE-SEE SHEET G2
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
3
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
4
RECORD DRAWING
PRECISION DRIVE
UD UD
UD UD UD UD
TELE
VAULT
ELEC
VAULT
ELECELEC
E
D
D D
D D
V.P.
V.P.
LODLOD
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LODLODLODLODLODLODLODLODLODLODLODLODLOD
LOD
LO
DLOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
BR
O
O
K
F
I
E
L
D
D
R
I
V
E
STORM DRAIN A2-2
SEE SHEET ST2
STORM DRAIN A2
SEE SHEET ST2
BLDG 12
BLDG 13
LOT 7
LOT 8
LOT 9
LOT 10
LOT 11
LOT 12
BLDG 14
GAR GAR GAR GAR GAR
GAR
GAR GAR GAR GAR GAR GAR GAR GAR GAR
GAR
GAR
GAR
GAR
GAR
GAR
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
CURB
4.5' WALK
4' WALK
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.5' WALK
4.5' WALK
4.5' WALK
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
C/O
GRATE
INLET
97.04 FL
D
D
D
D
C.O.
C.O.
C.O.
7.7%
16.8%
14.3%10.9%
11.1%
24
.
3
%
12.9%
16.5%
4.4%
21.1%
23.3%
3.8%
16.9%
18
.
5
%
23
.
7
%
23
.
5
%
29
.
5
%
31.5%
10.2%
14.1%
13.0%
31
.
4
%
1.7%
2.1%
15.3%
17.8%
24.3%
20
.
1
%
4.
7
%
5.
1
%
4.
2
%
2.1%
2.1%
97
.
2
5
FL
97
.
0
6
FL
FG=1.18
TF=1.85
FG=0.47
TF=1.14
FG=99.97
TF=100.64
FG=1.07
TF=1.74
97.4
6
97.0
6
96.9
1
96.3
0
98.2
0
98.4
4
98.1
6
97.8
8
97.4
3
97
.
7
4
97.8
6
97.9
9
96
.
6
5
LP
99.6
8
98.72
96.8
2
97.2
9
98.0
5
98.0
0
97.81 96.8
5
97.0
5
98.7
3
FL
99.1
0FL 99.2
2
FL
99.8
2
99.7
1 99.5
2
FL
99.2
6
98.1
8
97.9
1
98.0
2
98.0
2
99
.
8
1
99.
8
2
99.
4
5
98.
7
7
97.
9
7
99.3
5
99.
7
9
99.
9
3
99
.
5
6
98
.
8
6
99.
6
8
99
.
8
1
99
.
7
0
99.
1
3
99.1
6
98.8
2
99.1
1
99.0
0
99.2
1
98.7
4
99.1
5
98.7
5
98.1
9
98.0
6
98.0
9
98.
1
2
99
.
3
3
99
.
3
3
99.
5
4
99
.
3
3
99
.
4
7
99
.
0
7
99
.
4
2
99.
2
0
99
.
0
7
98
.
6
8
98
.
7
1
98.
4
8
98.
2
2
98.7
5
HP 98.7
1
98.4
9
98.2
2
98
.
3
3
98.3
1
98.2
7
98.2
5
97.7
9
97.2
4
96.9
9
96.
8
6
HP
96.5
4
99.
7
5
FL
97.89
98.07 98.30
99.3
3
99.0
8
99.0
9
98.6
5
98.1
7
98.
8
5
FL99.
3
0
FL98.
7
4
FL99.
2
1
FL99.
0
1
FL98
.
6
7
98
.
4
5
99.4
7
99.0
7 99.5
6
99.0
7
98.63
99.0
5
98.6
5 98.5
0
98.0
8 98.5
7
98
.
2
6
97.
7
6
FL98.
2
3
FL98.
3
2
FL98.
7
9
FL
98.7
2
98.7
9
98.7
0
98.63
97
.
8
3
97.
3
5
FL
97
.
0
6
FL
97.
1
1
97
.
0
7
96.
8
7
96
.
8
4
96
.
7
6
96
.
7
3
96
.
5
5
96.
5
1
96
.
1
4
96.
2
3
97
.
3
4
97.
3
7
97
.
5
8
97.
6
1
97.
6
8
97
.
7
1
97
.
7
1
97.
9
0
97
.
9
3
98.
0
1
98
.
0
2
98
.
0
3
98
.
3
2
FL
97
.
2
7
97.
2
0
FRONT=98.86 FRONT=98.80 FRONT=98.80 FRONT=98.80 FRONT=98.80
FRONT=98.84 FRONT=98.80 FRONT=98.80 FRONT=98.80 FRONT=98.80 FRONT=98.45 FRONT=98.24 FFE=98.04 FFE=97.69 FFE=97.48
99.5
3
98.7
3
99
.
0
5
99.9
3
99.5
3
99.9
3
99.4
2
99
.
5
3
99
.
5
3
99
.
2
9
98.2
5
98.7
1
FL
99.0
3
FL
99.5
0
FL
99.0
3
FL
99.5
0
FL
99.0
3
FL
FR
O
N
T
=
9
8
.
4
9
FR
O
N
T
=
9
8
.
4
0
FR
O
N
T
=
9
8
.
4
0
FR
O
N
T
=
9
8
.
4
2
FR
O
N
T
=
9
8
.
7
5
FR
O
N
T
=
9
9
.
2
5
96.7
9
96.9
7
96.9
9
97.2
0
97.1
2
97.5
5
97
.
5
3
FRONT=98.00
97.5
5
97.4
2
97.4
0
97.3
0
HP
97.
2
5
97.
2
0
97
.
0
4
96.7
3
96.6
9
97.4
4
98.6
8
99.1
3
98.3
4
FL 98.8
5
FL
97.2
7
HP
99.
7
2
99.2
0
97
.
5
2
97.
9
2
FG=1.07
TF=1.74
FG=1.07
TF=1.74
FG=1.07
TF=1.74
FG=1.07
TF=1.74
99.
4
6
FL
99.2
2
FL
99.2
7 99.3
4
99.18
99.0
9
99.
3
4
FL
98
.
7
7
FL
99.
0
1
FL
98.5
1
98.
0
3
FL
97
.
6
5
96.
7
0
97
.
1
7
FG=99.35
STEM WALL=
100.02
FG=99.60
STEM WALL=
100.27
FG=99.56
STEM WALL=
100.23
FG=99.27
STEM WALL=
99.94
FG=98.77
STEM WALL=
99.44
FG=98.57
STEM WALL=
99.24
FG=99.54
STEM WALL=
100.21
FG=99.47
STEM WALL=
100.14
FG=99.42
STEM WALL=
100.09
FG=1.07
TF=1.74
FG=99.29
STEM WALL=
99.96
FG=99.93
STEM WALL=
100.60
FG=99.93
STEM WALL=
100.60
FG=99.13
STEM WALL=
99.80
98.4
9
96
.
3
7
FL
96.
2
8
FL
98.6
1
97
.
1
9
97.8
2
97.7
3
96.8
9
98
.
2
9
99.30
98
.
0
6
99.30
96.9
6
97.2
6
99.6
3
97.1
8
97.1
4
97.4
0
97.4
0
97.3
4
97.3
2
97.5
7
97.
1
4
96.8
4
96.46
BW
97.34
TW
97.38
FL
97
.
2
2
96.7
0
96.7
7
96.7
3
98.4098.34
98.22
98.40
98.4
1
98.1
7
97.9
8
97.7
0
97.7
6
97.5
9
97.9
1
97.7
2
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
G2
GR
A
D
I
N
G
P
L
A
N
R.
B
a
n
n
i
n
g
A.
B
o
e
s
e
1"
=
2
0
'
18
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVER
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DEC
K
DEC
K
DECK
DECK
COVER
E
D
ENTR
Y
ENTR
Y
COVER
E
D
DECK
COVER
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTRY
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
LEGEND:
5013
PROPOSED CONTOUR 93
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED
LIMITS OF DISTURBANCE LOD
PROPOSED SPOT ELEVATION 33.43
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4.FINISHED GRADE ELEVATIONS DEPICTED HEREIN REPRESENT THE TOP LEVEL OF
FINISHED SURFACES, UNLESS OTHERWISE NOTED. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO ACCOUNT FOR DEPTH OF SOD, MULCH OR
OTHER LANDSCAPE SURFACE TREATMENTS TO ENSURE PROPER FINISHED GRADE
ELEVATIONS ARE ACHIEVED. THIS INCLUDES ACCOUNTING FOR TOPSOIL
AMENDMENTS FOR SEEDED AREAS AND OTHER LANDSCAPE/PLANTING PRACTICES
WHICH MAY AFFECT FINISHED GRADE.
5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YR STORM. FINISHED GRADE
ELEVATIONS AROUND BUILDINGS ARE SPECIFIED 4" BELOW FINISHED FLOOR.
WHERE ADDITIONAL SEPARATION IS REQUIRED FOR ISOLATION OF MATERIALS PER
BUILDING CODE, CONTRACTOR SHALL MAINTAIN MINIMUM GRADE AWAY FROM
FOUNDATIONS AS SHOWN ON THESE PLANS AND PER GEOTECHNICAL
RECOMMENDATIONS. FOUNDATION EXTENSIONS SUCH AS STEM WALLS OR
IMPERMEABLE MEMBRANES DESIGNED FOR PERMANENT UNDERGROUND USE
MUST BE INSTALLED AROUND FOUNDATIONS ACCORDING TO MANUFACTURERS
RECOMMENDATIONS. RECOMMENDED IMPERMEABLE MEMBRANE IS BITUTHENE
3000 OR APPROVED EQUAL.
6.ALL GARAGE DOWNSPOUTS DISCHARGING TO THE FRONT OF THE GARAGES SHALL
BE COORDINATED DURING CIVIL CONSTRUCTION. MIN 4" UNDERGROUND ROOF
DRAIN SERVICE LINES SHALL BE INSTALLED FROM ROOF DRAIN MAINS TO ALL SUCH
DOWNSPOUTS.
7.HABITAT BUFFER ZONE IS TO BE MAINTAINED IN A NATIVE LANDSCAPE. SEE
SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER
ZONE. HABITAT BUFFER ZONE IS BETWEEN THE LOT LINE AND EASTERN EDGE OF
PEDESTRIAN TRAIL.
NOTES:
PROPOSED STORM INLET
2.0%
PEDESTRIAN ACCESS RAMPS
(47.4
5
)
EXISTING SPOT ELEVATION
CURB & GUTTER
PROPOSED FIRE HYDRANT
PROPOSED ELECTRIC TRANSFORMER
LOT LINE
HIGH POINT HP
LOW POINT LP
FLOW LINE FL
EXISTING BRUSH LINE
EXISTING WATER SURFACE ELEVATION
TRAIL TR
TOP OF WALL TW
BOTTOM OF WALL BW
G1
G4G3
G2
MATCHLINE-SEE SHEET G1
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
4
RECORD DRAWING
X
X
X
X
X
X
X
X
X
X
X
X
X
X
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
LOD
LOD
LOD
LOD
LO
D
LO
D
LOD
LOD
LOD
LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
STORM DRAIN A
SEE SHEET ST1
STORM DRAIN A4
SEE SHEET ST1
STORM DRAIN A5
SEE SHEET ST3
BLDG 35
GARGARGARGARGARGAR
RAIN
GARDEN
DI
R
T
T
R
A
I
L
FO
S
S
I
L
C
R
E
E
K
R
E
S
E
R
V
O
I
R
I
N
L
E
T
D
I
T
C
H
4.5' WALK
10
'
T
R
A
I
L
10' T
R
A
I
L
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
DRAINAGE
EASEMENT
20' ACCESS
EASEMENT
WIDTH VARIES
HABITAT BUFFER ZONE
EXISTING
LOT LINE
WIDTH VARIES
NORTH POUDRE
IRRIGATION COMPANY
DITCH ROAD AND
MAINTENANCE
EASEMENT
FCRID
TOP OF BANK
50'
C/O
C/O GRATE
INLET
97.53 FL
D
D
D
D
C.O.
C.O.
C.O.
33.
7
%
20.9%
31.5%
24.6%
10.0
%
4.2
%
27.3
%30.8%
29.7%
24.8%
24.6%
27.4%
33.9%
25.4%
3.5%
20.4%
6.1%
3.6%
8.5%
5.5%
5.8%
9.2%
14.1
%
13
.
0
%
14.3%
18.4%
29.9%
9.3%
22.5%
42.
6
%
25.1%
31
.
6
%
38
.
5
%
25.
0
%
24.7%
23
.
8
%
30.6%
24.5%19.7%
82.66
TR/HP
96.90
FL
ELEV=96.90
98.9
3
97.8
3
99.49
98.3
6
97.9
4
FL
97.30
FL
99.
4
4
FL
98
.
0
8
FL
98
.
3
7
98.1
8
98.3
9HP 98.3
0
98.1
7
98.
4
1
98
.
5
6
98.0
6
98.56
98.5
0
0.5
3
0.1
90.5
999.
9
1
0.3
999.
7
3
99.
5
2
FL
99.
9
9
FL
99.
4
4
FL 0.1
6
FL
99.
6
9
FL 0.1
7
FL
99.
4
2 99.
9
8
99.
9
9
0.1
3
FRONT=98.92 FRONT=98.70 FRONT=98.70 FRONT=98.59 FRONT=98.75 FRONT=98.79
98
.
1
5
98
.
0
8
98.1
2
98.1
9
98.7
2
FL
98.12
FL
99.
2
2
99
.
5
8
99
.
2
2
97.
5
8
FL
97.60
99.0
4
82.38
81.82
98.
4
9
FL
FG=99.73
STEM WALL=
100.40
FG=0.39
STEM WALL=
1.06
FG=0.59
STEM WALL=
1.26
FG=0.53
STEM WALL=
1.20
98.1
3
98.2
1
97.9
5
98.0
5
98.
3
4
98.2
3
98.3
2
FG=1.90
TF=2.57
98.02
FL
98
.
1
4
98.84
98.75
98.6198.7
0
98.93
98.
5
5
98.4
6
98.5798.4
8
99
.
0
8
98.
2
4
(95
.
0
1
)
96.6
6
95.5595.9
3
97.71
97.7
4 96.8
1
96.7
1
96.2
1
95.5
7
(94
.
8
0
)
(93
.
7
8
)
79.6
5
TR79.7
4
TR79.8
3
TR
81.2
5
TR
81.1
5
TR
81.0
5
TR
82.1
3TR82.2
3TR82.3
3TR
82.1
2TR
82.56
TR
81.5
1TR
81.3
1TR
82.1
3TR82.2
3TR
82.0
3TR
82.55
TR
82.22
TR
82.32
TR
81.4
1TR/
L
P
82.76
TR
82.56
TR
82.7
4
TR82.6
4
TR82.8
4
TR
81.6
8
(82.79)
(82
.
1
4
)
(81
.
7
5
)
(82
.
4
6
)
(81
.
6
9
)
(81
.
0
0
)
82.8
3
82.8
8
82.5
1
82.3
6
82.9
5
83.08
HP
82.4
6
82.6
8
82.5
4
82.5
7
81.8
0
82.7
0
82.7
5
82.4
4
82.4
6
98.2
0
98.2
0
98.2
0
98.2
0
99.0
0
99.4
1
98.20
98.90
FL
96.9
0
96.9
0
99.57
99.13
99
.
5
4
99.
5
1
99
.
4
6
99
.
4
2
99.
6
0
99.
5
7
99.
5
7
99.
5
7
98.
4
5
98.
5
7
98.
6
6
98.
6
6
98.55
98.4
8
98.2
0
99.48
TW
98.84
98
.
3
6
86.93
TW
84.93
BW
91.03
TW
85.03
BW
91.53
TW
84.53
BW90.59
TW
84.59
BW
98.4
8
BW
99.53
TW
95.5
3
BW
99.8
7
TW
94.8
7
BW
99.
5
7
0.86
TW
95.0
0
BW
95.9
0
BW
95.3
3
BW 95.0
7
BW
95.8
8
BW
95.9
0BW
91.68
TW
84.68
BW
91.76
TW
84.76
BW
91.79
TW
84.79
BW
90.80
TW
84.80
BW
1.07
TW
0.29
TW
99.2
9
TW
98.8
0
TW
98.7
9TW
90.88
TW
84.86
BW93.3
0
BW
83.2285.0992.7
9
BW
99
.
6
7
FL
98.
1
6
98.3
0
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
G3
GR
A
D
I
N
G
P
L
A
N
R.
B
a
n
n
i
n
g
A.
B
o
e
s
e
1"
=
2
0
'
19
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVER
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DEC
K
DEC
K
DECK
DECK
COVER
E
D
ENTR
Y
ENTR
Y
COVER
E
D
DECK
COVER
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTRY
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
LEGEND:
5013
PROPOSED CONTOUR 93
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED
LIMITS OF DISTURBANCE LOD
PROPOSED SPOT ELEVATION 33.43
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4.FINISHED GRADE ELEVATIONS DEPICTED HEREIN REPRESENT THE TOP LEVEL OF
FINISHED SURFACES, UNLESS OTHERWISE NOTED. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO ACCOUNT FOR DEPTH OF SOD, MULCH OR
OTHER LANDSCAPE SURFACE TREATMENTS TO ENSURE PROPER FINISHED GRADE
ELEVATIONS ARE ACHIEVED. THIS INCLUDES ACCOUNTING FOR TOPSOIL
AMENDMENTS FOR SEEDED AREAS AND OTHER LANDSCAPE/PLANTING PRACTICES
WHICH MAY AFFECT FINISHED GRADE.
5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YR STORM. FINISHED GRADE
ELEVATIONS AROUND BUILDINGS ARE SPECIFIED 4" BELOW FINISHED FLOOR.
WHERE ADDITIONAL SEPARATION IS REQUIRED FOR ISOLATION OF MATERIALS PER
BUILDING CODE, CONTRACTOR SHALL MAINTAIN MINIMUM GRADE AWAY FROM
FOUNDATIONS AS SHOWN ON THESE PLANS AND PER GEOTECHNICAL
RECOMMENDATIONS. FOUNDATION EXTENSIONS SUCH AS STEM WALLS OR
IMPERMEABLE MEMBRANES DESIGNED FOR PERMANENT UNDERGROUND USE
MUST BE INSTALLED AROUND FOUNDATIONS ACCORDING TO MANUFACTURERS
RECOMMENDATIONS. RECOMMENDED IMPERMEABLE MEMBRANE IS BITUTHENE
3000 OR APPROVED EQUAL.
6.ALL GARAGE DOWNSPOUTS DISCHARGING TO THE FRONT OF THE GARAGES SHALL
BE COORDINATED DURING CIVIL CONSTRUCTION. MIN 4" UNDERGROUND ROOF
DRAIN SERVICE LINES SHALL BE INSTALLED FROM ROOF DRAIN MAINS TO ALL SUCH
DOWNSPOUTS.
7.HABITAT BUFFER ZONE IS TO BE MAINTAINED IN A NATIVE LANDSCAPE. SEE
SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER
ZONE. HABITAT BUFFER ZONE IS BETWEEN THE LOT LINE AND EASTERN EDGE OF
PEDESTRIAN TRAIL.
NOTES:
PROPOSED STORM INLET
2.0%
PEDESTRIAN ACCESS RAMPS
(47.4
5
)
EXISTING SPOT ELEVATION
CURB & GUTTER
PROPOSED FIRE HYDRANT
PROPOSED ELECTRIC TRANSFORMER
LOT LINE
HIGH POINT HP
LOW POINT LP
FLOW LINE FL
EXISTING BRUSH LINE
EXISTING WATER SURFACE ELEVATION
TRAIL TR
TOP OF WALL TW
BOTTOM OF WALL BW
G1 G2
G4G3
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
1
MATCHLINE-SEE SHEET G4
RECORD DRAWING
X
X
UD UD UD UD UD UD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LO
D
LO
D
LO
D
LO
D
LOD
LODLODLODLODLODLODLODLOD
LOD
LO
D
LO
D
LO
D
LO
D
1' PAN
STORM DRAIN A3
SEE SHEET ST3
STORM DRAIN A4
SEE SHEET ST1
BLDG 37
BLDG 36 TRACT B
GAR GAR GAR GAR GAR GAR
GAR
GAR
GAR
GAR
GAR
GAR
GARGARGARGARGARGAR
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
DI
R
T
T
R
A
I
L
FO
S
S
I
L
C
R
E
E
K
R
E
S
E
R
V
O
I
R
I
N
L
E
T
D
I
T
C
H
4' WALK
4.5' WALK
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
10
'
T
R
A
I
L
10
'
T
R
A
I
L
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
20' ACCESS
EASEMENT
WIDTH VARIES
HABITAT BUFFER ZONE
WIDTH VARIES
HABITAT BUFFER ZONE
WIDTH VARIES
NORTH POUDRE
IRRIGATION COMPANY
DITCH ROAD AND
MAINTENANCE
EASEMENT
FCRID
TOP OF BANK
50'
D
D
D
D
24.6%
27.4%
20.4%
20.4%
35.0%
18.3%
25.5%
25.0%
25.2%
28.6%25.3%
23
.
5
%
15.3%
17.8%
1.3%
2.3%
12
.
9
%
12
.
2
%
20.5
%
24.3%
20
.
1
%
17
.
4
%
2.1%
24.5%19.7%
25.9%
27.3%
36.2%
34.5%
2.0%
2.1%
1.
9
%
3.1%
4.7
%
7.4%
5.5%
FG=0.80
TF=1.47
98.4
0
98.1
1
97.6
8
97.
6
2
97.4
6
97.0
6
96.9
1
97.8
3
97.
0
6
96.9
5
98.3
6
97.5
0
97.2
9 97.4
2
HP
98.2
6
98.2
0
98.1
0
98.1
2
98.1
1
97.4
0
96.7
9
96.9
7
96.9
9
97.2
0
97.1
2
97.5
5
97
.
5
3
98.1
8
98.3
9HP 98.3
0
98.1
7
98
.
4
1
98.
5
6
98.0
6
98.56
98.5
0
98.4
7 98.6
8
0.5
3
0.1
90.5
999
.
9
1
0.3
9
99
.
9
9
0.1
3
FRONT=98.92 FRONT=98.70 FRONT=98.70 FRONT=98.59 FRONT=98.75 FRONT=98.79
FRONT=98.24FRONT=98.21FRONT=98.21FRONT=97.94FRONT=97.94FRONT=98.00
FR
O
N
T
=
9
8
.
8
2
FR
O
N
T
=
9
9
.
0
1
FR
O
N
T
=
9
9
.
0
1
FR
O
N
T
=
9
9
.
0
6
FR
O
N
T
=
9
9
.
0
6
FR
O
N
T
=
9
9
.
1
0
98.
1
5
98.
0
8
97.9
8
97.9
6
97.8
3
97.7
5
97.6
3
97.5
5
97.4
2
97.4
0
97.3
0
HP
97.
2
5
97.
2
0
97
.
0
4
96.7
3
96.6
9
97.4
4 97.6
9
97.7
5 97.8
9
97.9
5 97.6
2
97
.
4
5
96.
0
2
95
.
9
2
94.
2
9
97.5
6
97.7
1
97.7
7
97.9
1
97.9
7
97.5
3
96.0
2
95
.
9
2
94.2
9
98.6
8
99.0
5
99.1
3
99.5
9
99.1
8
99.5
8
99.1
0 99.0
8
99.1
8
99.0
3
98.9
3
98.3
4
FL 98.8
5
FL 98.
5
9
98.5
9
FL 99.2
0
FL 98.7
3
FL 99.2
0
FL 98.7
3
FL 98.7
9
FL
97.2
7
HP 97.1
9
97.5
0
97.8
2
97.9
8
98.0
4
98.0
4
97.9
4
97.6
4
97.9
4
98.1
2
98.4
3
98.5
3
98.1
2
98.1
9
99.
6
6
FL
0.1
3
FL
99.
6
6
FL
0.1
3
FL
99.
6
6
FL
99.
3
9
FL
99.
1
9
FL
0.13
99.9
3
0.56
0.16
0.56
0.16
99.7
5
0.1
6
0.1
5
99.
7
3
0.1
6
82.38
99.1
9FL
FG=99.13
STEM WALL=
99.80
FG=99.59
STEM WALL=
100.26
FG=99.58
STEM WALL=
100.25
FG=99.08
STEM WALL=
99.75
FG=0.16
STEM WALL=
0.83
FG=0.56
STEM WALL=
1.23
FG=0.56
STEM WALL=
1.23
FG=99.93
STEM WALL=
100.60
FG=99.73
STEM WALL=
100.40
FG=0.39
STEM WALL=
1.06
FG=0.59
STEM WALL=
1.26
FG=0.53
STEM WALL=
1.20
95
.
4
6
96.
6
0
96.
8
7
FL
96
.
8
1FL
96
.
6
3
FL
96
.
3
7
FL
96.
2
8
FL
98.4
4
98.5
8
98.1
7
98.2
7
98.1
3
98.2
1
97.9
5
98.0
5
98
.
3
4
HP
98.2
3
98.3
2
98.5
0
98.5
5
98.5
3
97.8
7
98.1
3
97.6
8
97.7
9
98.0
5
98.00
97.8
0
98.0
7
97.1
8
FG=1.27
TF=1.94
98.
1
4
97
.
1
9
96.8
9
97.2
6
97.1
8
97.1
4
97.4
0
97.4
0
97.3
4
97.3
2
98.1
2
98.1
4
98.0
9
98.3
2
98.3
4
98.2
8
97.8
1
97.7
7
97.5
7
97.6
1
98.
2
4
97.
1
4
96.8
4
82.1
3TR82.2
3TR
82.0
3TR
82.7
4
TR82.6
4
TR82.8
4
TR
99.2
9
TW
98.8
0
TW
98.7
4TW
98.7
9TW
98.5
6
TW
90.88
TW
84.86
BW93.3
0
BW
83.22
91.09
TW
85.09
BW
92.7
9
BW
92.
8
0
84.05
88.06
TW
87.06
BW98
.
7
8
98
.
8
7
98
.
8
4
98
.
6
9
98.
5
0
98.
4
1
98.
4
0
98
.
1
6
98.
1
6
98.5
8
98.6
7
0.01
0.22
83.4
8
TR83.3
8
TR83.5
8
TR
84.4
8
TR84.3
8
TR84.5
8
TR
(82.0
0
)
(82.4
7
)
(82.5
8
)
(82.8
3
)
(82.7
6
)
85.4
0
83.5
4
83.1
2
83.2
9
83.6
1
83.2
2
83.1
0
82.9
8
86.2
0
86.7
5
89.1
5
90.3
0
91.3
5
91.8
7
93.3
7
91.1
1
89.
5
4
TR 89.4
4
TR
89.64
TR
92.4
3
TR92.5
3
TR92.6
3
TR
93.3
9
TR
93.4
4
TR
93.4
8
TR
93.8
5
TR
93.8
6
TR
93.8
7
TR
93.56
TR
97.39
BW
97.68
TW96.46
BW
97.34
TW
96.71
BW
97.66
TW
98
.
1
6
97
.
2
2
96.7
0
96.7
7
96.7
3
98.0
2
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
G4
GR
A
D
I
N
G
P
L
A
N
R.
B
a
n
n
i
n
g
A.
B
o
e
s
e
1"
=
2
0
'
20
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
KEYMAP
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVER
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DEC
K
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTRY
COVE
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVER
E
D
ENTR
Y
DEC
K
DEC
K
DECK
DECK
COVER
E
D
ENTR
Y
ENTR
Y
COVER
E
D
DECK
COVER
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTRY
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DECK
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
LEGEND:
5013
PROPOSED CONTOUR 93
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED
LIMITS OF DISTURBANCE LOD
PROPOSED SPOT ELEVATION 33.43
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4.FINISHED GRADE ELEVATIONS DEPICTED HEREIN REPRESENT THE TOP LEVEL OF
FINISHED SURFACES, UNLESS OTHERWISE NOTED. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO ACCOUNT FOR DEPTH OF SOD, MULCH OR
OTHER LANDSCAPE SURFACE TREATMENTS TO ENSURE PROPER FINISHED GRADE
ELEVATIONS ARE ACHIEVED. THIS INCLUDES ACCOUNTING FOR TOPSOIL
AMENDMENTS FOR SEEDED AREAS AND OTHER LANDSCAPE/PLANTING PRACTICES
WHICH MAY AFFECT FINISHED GRADE.
5.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YR STORM. FINISHED GRADE
ELEVATIONS AROUND BUILDINGS ARE SPECIFIED 4" BELOW FINISHED FLOOR.
WHERE ADDITIONAL SEPARATION IS REQUIRED FOR ISOLATION OF MATERIALS PER
BUILDING CODE, CONTRACTOR SHALL MAINTAIN MINIMUM GRADE AWAY FROM
FOUNDATIONS AS SHOWN ON THESE PLANS AND PER GEOTECHNICAL
RECOMMENDATIONS. FOUNDATION EXTENSIONS SUCH AS STEM WALLS OR
IMPERMEABLE MEMBRANES DESIGNED FOR PERMANENT UNDERGROUND USE
MUST BE INSTALLED AROUND FOUNDATIONS ACCORDING TO MANUFACTURERS
RECOMMENDATIONS. RECOMMENDED IMPERMEABLE MEMBRANE IS BITUTHENE
3000 OR APPROVED EQUAL.
6.ALL GARAGE DOWNSPOUTS DISCHARGING TO THE FRONT OF THE GARAGES SHALL
BE COORDINATED DURING CIVIL CONSTRUCTION. MIN 4" UNDERGROUND ROOF
DRAIN SERVICE LINES SHALL BE INSTALLED FROM ROOF DRAIN MAINS TO ALL SUCH
DOWNSPOUTS.
7.HABITAT BUFFER ZONE IS TO BE MAINTAINED IN A NATIVE LANDSCAPE. SEE
SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER
ZONE. HABITAT BUFFER ZONE IS BETWEEN THE LOT LINE AND EASTERN EDGE OF
PEDESTRIAN TRAIL.
NOTES:
PROPOSED STORM INLET
2.0%
PEDESTRIAN ACCESS RAMPS
(47.4
5
)
EXISTING SPOT ELEVATION
CURB & GUTTER
PROPOSED FIRE HYDRANT
PROPOSED ELECTRIC TRANSFORMER
LOT LINE
HIGH POINT HP
LOW POINT LP
FLOW LINE FL
EXISTING BRUSH LINE
EXISTING WATER SURFACE ELEVATION
TRAIL TR
TOP OF WALL TW
BOTTOM OF WALL BW
G1 G2
G3 G4
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
2
MATCHLINE-SEE SHEET G3
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
1
RECORD DRAWINGSUBSURFACE GRADING PLAN WAS NOT SURVEYED AND,
THEREFORE, NOT INCLUDED IN THIS CERTIFICATION.
Project:
Date:
Min Flat Area 310 sf Min Required Volume 466 cf
Asbuilt Flat Area 1269 sf Asbuilt Provided Volume 1,260 cf
Design Grate Elev 4897.53 ft
Asbuilt Grate Elev 4897.74 ft
Maximum
Elevation
Minimum
Elevation
4,896.90 4896.85 0.21 N/A Low Point N/A
4,896.95 4896.90 2.54 0.05 0.07
4,897.00 4896.95 5.36 0.05 0.20
4,897.00 4897.00 7.45 0.00 0.00
4,897.05 4897.00 66.66 0.05 1.85
4,897.05 4897.05 14.93 0.00 0.00
4,897.10 4897.05 192.42 0.05 5.18
4,897.10 4897.10 24.99 0.00 0.00
4,897.15 4897.10 352.38 0.05 9.43
4,897.20 4897.15 472.96 0.05 20.63
4,897.25 4897.20 588.20 0.05 26.53
4,897.30 4897.25 697.28 0.05 32.14
4,897.35 4897.30 801.00 0.05 37.46
4,897.40 4897.35 900.17 0.05 42.53
4,897.45 4897.40 996.54 0.05 47.42
4,897.50 4897.45 1089.94 0.05 52.16
4,897.55 4897.50 1176.90 0.05 56.67
4,897.57 4897.55 1209.55 0.02 23.86
4,897.60 4897.57 1255.86 0.03 36.98
4,897.65 4897.60 1325.96 0.05 Design WQCV 64.55
4,897.70 4897.65 1387.21 0.05 67.83
4,897.74 4897.70 1429.83 0.04 Inlet Rim 56.34
4,897.75 4897.74 1439.59 0.01 14.35
4,897.80 4897.75 1483.12 0.05 73.07
4,897.85 4897.80 1517.79 0.05 75.02
4,897.90 4897.85 1544.66 0.05 76.56
4,897.95 4897.90 1570.38 0.05 77.88
4,898.00 4897.95 1596.12 0.05 79.16
669.25
744.27
820.83
898.71
977.87
393.12
457.67
525.49
581.84
596.18
176.02
223.44
275.60
332.27
356.14
133.49
7.30
16.74
37.37
63.90
96.04
0.07
0.27
2.12
2.12
7.30
0.00
Project Number:
Project Location:
Calculations By:
Pond No.:
0.27
Rain Garden Stage Storage Report
Contour Contour
Surface
Area (ft2)
Depth
Rain Garden Stage Storage Curve
374-020
Fort Collins, CO
S. Hallauer
Rain Garden
Rain Garden Outlet and Volume Data
Brookfield Second Replat
7/13/2021
Incremental
Volume (cu. ft.)
Cumualitive
Volume (cu. ft.) Feature
4,898.05 4898.00 1115.46 0.05 67.79
4,898.10 4898.05 1001.64 0.05 52.93
4,898.15 4898.10 905.36 0.05 47.68
4,898.20 4898.15 816.84 0.05 43.05
4,898.25 4898.20 726.83 0.05 38.59
4,898.30 4898.25 572.78 0.05 32.49 1260.40
1045.66
1098.59
1146.26
1189.32
1227.91
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 1 | 11
INSTALLED PERMEABLE PAVERS
NO OBSERVABLE
STANDING WATER
IN ALLEY
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 2 | 11
CONSTRUCTED BIOSWALE
LOOKS ACCURATE
INSTALLED RIPRAP
RUNDOWN
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 3 | 11
INLET AT PROPER HEIGHT
AND EROSION FABRIC CUT
INSIDE
NO OBSERVABLE
STANDING WATER
IN ALLEY
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 4 | 11
CONCRETE PAN HAS
SETTLED TO 0.1%
(MENTIONED IN SITE CERT)
BUT NO OBSERVABLE
STANDING WATER
INSTALLED PERMEABLE PAVERS
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 5 | 11
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 6 | 11
RAIN GARDEN APPEARS TO BE
CONSTRUCTED CORRECTLY.
CONTRACTOR NOTIFIED OF
DEBRIS AND THEY REMOVED
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 7 | 11
TURF INSTALLED AS PER
PLAN BUT IS HAVING
DIFFICULTY MAINTAINING
SIDEWALK CHASE APPEARS
TO BE FUNCTIONING
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 8 | 11
INSTALLED PERMEABLE PAVERS
APPEARS TO BE PAVER
UNDERDRAIN PIPE TYING
INTO INLET PER PLAN
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 9 | 11
INSTALLED PERMEABLE PAVERS
NO OBSERVABLE
STANDING WATER
IN ALLEY
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 10 | 11
NUISANCE WATER BUT DOES NOT
PROHIBIT DRAINAGE FLOW TO INLET
AROUND THE CORNER.
CONTRACTOR RAISED RAIN
GARDEN INLET TO PROPER
ELEVATION FOR STORAGE
VOLUME.
NORTHERNENGINEERING.COM | 970.221.4158
FORT COLLINS | GREELEY 11 | 11
INLET SNOUT INSTALLED
PER PLAN
8" W8" W8" W8" W8" W
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
G E
E
E
E
E
E
E
E
15" SS 15" SS
8" W 8" W
12" SS 12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CT
V
CTV
H2
O
H2
O
H2
O
H2
O
H2
O
BLDG 9
BLDG 8
BLDG 11
BLDG 12
BLDG 13
BLDG 37
BLDG 36
BLDG 35
LO
T
1
LO
T
2
LO
T
3
LO
T
4
LO
T
5
LO
T
6
LO
T
7
LO
T
8
LO
T
9
LO
T
1
0
LO
T
1
1
LO
T
1
2
TRACT A
TRACT B
BLDG 10
BLDG 14
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
GARAGE
(TYP.)
WVWV
WV
S S
S
S
S
H2
O
X
X
X
S
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8" W8" W8" W8" W8" W8" W8" W8" W8" W
HYD
WV
WV
WV
W
W
WV WV
8" W8" W8" W8" W8" W8" W8" W8" W
WV
WV
TE
L
E
T T
T
T
T
T
T
T
H2
O
GA
S
G G
G
G
GA
S
E
E
E
VA
U
L
T
EL
E
C
E
VA
U
L
T
EL
E
C
EL
E
C
EE
E
E
E
E
12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS12" SS
D D
D
D
D
V.
P
.
V.
P
.
S
W
S
S W
S W
S W
S
WS
W
W
W
UD
UD
UD
UD
UD
UD
UD
UD
UD
W
W
W
WWWWW
WWWWW
E
W
W
W
STA. 18+48.45
CONNECT TO EX. 8" WATER
N:105920.59
E:215153.70
TRACT F
REPLAT OF BROOKFIELD
MO
R
N
I
N
G
S
I
D
E
VI
L
L
A
G
E
C
O
N
D
O
S
OWNER:
IMAGO ENTERPRISES INC
140 PALMER DR.
FORT COLLINS, CO 80525
WETLAND
OWNER:
MORNINGSIDE VILLAGE
MASTER ASSOCIATION INC.
BLDG
31
BLDG
23
BLDG
22
BLDG
14
BROOKFIELD DRIVE
LE
F
E
V
E
R
D
R
I
V
E
PR
E
C
I
S
I
O
N
D
R
I
V
E
NORTHERN LIGHTS DRIVE
FOSSIL C
R
E
E
K
INLET DITCH
RESERVOIR
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
330.95 LF 8" PVC
S01°23'27"W
171.39 LF 8" PVC
S01°23'27"W
FIELD LOCATE
AND CONNECT
TO EXISTING
8" STUB OUT
STA. 10+53.06
8"x8" CROSS
3 - 8" GV (W,E,S)
N:106425.43
E:214870.75
STA. 16+77.06
8"x6" SWIVEL TEE
1 - 6" GV (W)
& FH ASSEMBLY
N:106091.93
E:215157.86
SAN MH A2
CONNECT TO
EX SAN MH A1
EX. SAN MH
14
6
.
4
6
L
F
8
"
P
V
C
S8
9
°
2
9
'
0
2
"
E
STA. 11+97.43
8"x6" SWIVEL TEE
1 - 6" GV (N)
& FH ASSEMBLY
N:106424.12
E:215017.21
EX
.
4
.
5
'
W
A
L
K
EX. 4.5' WALK
FU
T
U
R
E
4
.
5
'
W
A
L
K
FUTURE 4.5' WALK
4.5' WALK
4.5' WALK
4.5' WALK
4.
5
'
W
A
L
K
FU
T
U
R
E
4
.
5
'
W
A
L
K
4.5' WALK
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.5' WALK
4.5' WALK
FU
T
U
R
E
4
.
5
'
W
A
L
K
EX. 10' PEDESTRIAN TRAIL
10' PEDESTR
I
A
N
T
R
A
I
L
EX. 15" SANITARY
SEWER
EX. 8" WATERLINE
EX. STORM DRAIN
EX. FIRE HYDRANT
EX. STORM
DRAIN
EX. 15" SANITARY
SEWER
EX. 8" WATERLINE
EX. FIRE
HYDRANT
EXISTING SANITARY
SERVICE STUB (TYP.)
APPROXIMATE LOCATION
EXISTING WATER SERVICE (TYP.)
STORM DRAIN A
SEE SHEET ST1
STORM DRAIN A2
SEE SHEET ST2
STORM DRAIN A
SEE SHEET ST1
STORM DRAIN A4
SEE SHEET ST1
STORM DRAIN A3
SEE SHEET ST3
STORM DRAIN A2-2
SEE SHEET ST2
STORM DRAIN A5
SEE SHEET ST3
SANITARY SEWER A
SEE SHEET SS1
2' SIDEWALK CHASE
6" SANITARY
SERVICE (TYP.)
EX. SANITARY
SERVICE STUB
1 1/2" WATER
SERVICE
DEFLECT WATER UNDER STORM
PER DETAIL 4A ON SHEET D2
APPROXIMATE LOCATION
CURB STOP/METER PIT
CONTRACTOR TO VERIFY
LOCATION, 1 1/2" DIA AND
CONSTRUCTION (TYP.)
3/4" WATER
SERVICE (TYP.)
RE-LOCATE METER PIT
1 1/2" WATER SERVICE
RE-LOCATE METER PIT
1 1/2" WATER SERVICE
1 1/2" WATER
SERVICE
1 1/2" WATER
SERVICE 1 1/2" WATER
SERVICE
STORM DRAIN A2-2
SEE SHEET ST2
STORM DRAIN A5-1
SEE SHEET ST3
30' TEMPORARY
DRAINAGE &
GRADING
EASEMENT
30'
FL-FL
51' ROW
51
'
R
O
W
30
'
F
L
-
F
L
30
'
F
L
-
F
L
51
'
R
O
W
FUTURE
30'
FL-FL
20' PRIVATE
DRIVE
20' PRIVATE
DRIVE
20' PRIVATE
DRIVE
20' PRIVATE
DRIVE
EXISTING
51' ROW
EXISTING
30'
FL-FL
EXISTING 20'
DRAINAGE EASEMENT
9' UTILITY EASEMENT
FUTURE 9'
UTILITY EASEMENT
24'
DE, UE,
AE & EAE
24'
DE, UE,
AE & EAE
24
'
D
E
,
U
E
,
AE
&
E
A
E
10' SEPERATION (TYP.)
10' SEPERATION (TYP.)
24'
DE, UE,
AE & EAE
24
'
D
E
,
U
E
,
AE
&
E
A
E
24'
DE, UE,
AE & EAE
WIDTH VARIES
HABITAT
BUFFER ZONE
LIGHT
POLE
(TYP.)
LIGHT POLE (TYP.)
TRANSFORMER (TYP.)
TRANSFORMER (TYP.)
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.
5
'
W
A
L
K
4.5' WALK
STORM DRAIN A6
SEE SHEET ST3
20' ACCESS
EASEMENT
DRAINAGE
EASEMENT
DRAINAGE
EASEMENT
WIDTH VARIES
NORTH POUDRE
IRRIGATION COMPANY
DITCH ROAD AND
MAINTENANCE
EASEMENT
FCRID
TOP OF BANK
50'
14
8
.
6
9
L
F
8
"
P
V
C
S8
9
°
2
9
'
0
2
"
E
STA. 13+46.11
8"x8" TEE w/ TB
2-8" GV (E,W)
N:106422.78
E:215165.89
20' EASEMENT
BY SEPARATE DOC.
////
/
/
/
/
///
/
/
/
/
/
/////////////////
/
/
/
/
//
/
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
U1
OV
E
R
A
L
L
U
T
I
L
I
T
Y
P
L
A
N
A.
B
o
e
s
e
A.
B
o
e
s
e
1"
=
3
0
'
12
( IN FEET )
0
1 INCH = 30 FEET
30 30 60 90
LEGEND:
NOTES:
W
G
T
E/T/C
S
W
SS
E
F
CTV
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
1
/
/
/
/
//////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
2
2
RECORD DRAWING
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+0012+0013+0014+0015+0016+0017+0018+00
8" WATER
STA.=15+37.98
TOP=4891.63
STA.=15+27.98
INV.= 4888.59
8" PVC SANITARY
CONTRACTOR TO
VERIFY LOCATION PRIOR
TO CONSTRUCTION
1.72'
STA.=10+33.01
INV.= 4887.80
6" SANITARY
SERVICE
(APPROXIMATE
LOCATION)
EXISTING
GROUND
PROPOSED
GRADE
37.94 LF
24" RCP
@ 1.68%
MH
A
2
ST
A
1
1
+
4
8
.
9
4
RI
M
4
8
9
6
.
3
±
IN
V
.
I
N
4
8
9
1
.
0
1
(
N
)
IN
V
.
I
N
4
8
9
1
.
4
3
(
W
)
IN
V
.
O
U
T
4
8
9
0
.
9
1
(
S
)
102.09 LF 24" RCP @ 0.41%
MH
A
3
ST
A
1
2
+
5
1
.
0
3
RI
M
4
8
9
6
.
8
±
IN
V
.
I
N
4
8
9
1
.
6
3
(
N
)
IN
V
.
I
N
4
8
9
2
.
1
3
(
E
)
IN
V
.
O
U
T
4
8
9
1
.
4
3
(
S
)
177.67 LF
18" RCP
@ 0.60%
MH
A
4
ST
A
1
4
+
2
8
.
7
0
RI
M
4
8
9
7
.
7
±
IN
V
.
I
N
4
8
9
2
.
8
0
(
N
)
IN
V
.
I
N
4
8
9
3
.
2
0
(
E
)
IN
V
.
O
U
T
4
8
9
2
.
7
0
(
S
)
89.28 LF
18" RCP
@ 0.60%
MH
A
5
ST
A
1
5
+
1
7
.
9
8
RI
M
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
3
.
3
3
(
W
)
IN
V
.
I
N
4
8
9
2
.
8
3
(
N
E
)
IN
V
.
O
U
T
4
8
9
3
.
3
3
(
S
)
47.34 LF
12" RCP
@ 0.60%
AR
E
A
I
N
L
E
T
A
6
w
/
S
N
O
U
T
ST
A
1
5
+
6
5
.
3
2
FL
.
E
L
4
8
9
8
.
7
±
IN
V
.
I
N
4
8
9
4
.
6
9
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
6
9
(
W
)
IN
V
.
I
N
4
8
9
6
.
5
0
(
S
)
IN
V
.
O
U
T
4
8
9
3
.
6
2
(
E
)
185.54 LF
12" HDPE
@ 0.60%
AR
E
A
I
N
L
E
T
A
7
ST
A
1
7
+
5
0
.
8
6
FL
.
E
L
4
9
0
0
.
1
±
IN
V
.
O
U
T
4
8
9
5
.
8
0
(
E
)
EX
M
H
A
1
ST
A
1
0
+
1
1
.
0
6
RI
M
4
8
9
5
.
7
±
IN
V
.
I
N
4
8
8
9
.
7
9
(
N
)
IN
V
.
I
N
4
8
8
9
.
5
1
(
W
)
IN
V
.
O
U
T
4
8
8
8
.
1
1
(
S
)
PUBLIC
STORM
SEWER
PRIVATE
STORM
SEWER
ROW
100-YR HGL
99.94 LF 24" RCP @ 0.38%
MH
A
1
.
5
ST
A
1
0
+
4
9
.
0
0
RI
M
4
8
9
5
.
8
±
IN
V
.
I
N
4
8
9
0
.
5
3
(
N
)
IN
V
.
O
U
T
4
8
9
0
.
4
3
(
S
)
TIE INTO EXISTING
STORM DRAIN
S
S
W
UD
W
W
BLDG 9 BLDG 8
BLDG 35
LOT 1
LOT 2
BLDG 10
51' ROW
30'
FL-FL
89.28 LF
18" RCP
@ 0.60%
MH A5
STA 15+17.98
N: 106304.03
E: 215183.01AREA INLET A6 w/ SNOUT
STA 15+65.32
N: 106305.18
E: 215135.69
185.54 LF
12" HDPE
@ 0.60%
AREA INLET A7
STA 17+50.86
N: 106306.85
E: 214950.15
SANITARY LINE A
SEE SHEET SS1
STORM DRAIN A5
SEE SHEET ST3
47.34 LF
12" RCP
@ 0.60%
STORM DRAIN A6
SEE SHEET ST3
S
W
S
W
S
W
W
W
W
W
W
W
LOT 4
BLDG 36
BLDG 35
LOT 1
LOT 2
LOT 3
LOT 5
LOT 6
LOT 7
LOT 8
TRACT B
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
51' ROW
30'
FL-FL
MH A4
STA 10+00.00
N: 106214.77
E: 215180.84
88.09 LF 12" RCP @ 0.50%
AREA INLET A4-1
STA 10+88.09
N: 106212.64
E: 215268.91
STORM DRAIN A
SEE THIS SHEET
36.66 LF
8" PVC
@ 0.50%
MH A4-2
STA 11+26.37
N: 106201.05
E: 215305.20
101.85 LF
8" PVC
@ 0.50%
AREA INLET A4-3
STA 12+28.22
N: 106099.29
E: 215309.44
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+50 10+00 11+00 12+00 12+50
EXISTING
GROUND
PROPOSED
GRADE
88.09 LF
12" RCP
@ 0.50%
MH
A
4
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
7
.
7
±
IN
V
.
I
N
4
8
9
2
.
8
0
(
N
)
IN
V
.
I
N
4
8
9
3
.
2
0
(
E
)
IN
V
.
O
U
T
4
8
9
2
.
7
0
(
S
)
AR
E
A
I
N
L
E
T
A
4
-
1
ST
A
1
0
+
8
8
.
0
9
FL
.
E
L
4
8
9
7
.
8
±
IN
V
.
I
N
4
8
9
3
.
9
7
(
E
)
IN
V
.
O
U
T
4
8
9
3
.
6
4
(
W
)
PRIVATE
STORM
SEWER
PUBLIC
STORM
SEWER
ROW
AR
E
A
I
N
L
E
T
A
4
-
3
ST
A
1
2
+
2
8
.
2
2
FL
.
E
L
4
8
9
8
.
0
±
IN
V
.
O
U
T
4
8
9
4
.
6
6
(
N
)
101.85 LF
8" PVC
@ 0.50%
MH
A
4
-
2
ST
A
1
1
+
2
6
.
3
7
RI
M
4
8
9
8
.
2
±
IN
V
.
I
N
4
8
9
4
.
1
5
(
S
)
IN
V
.
O
U
T
4
8
9
4
.
1
5
(
W
)
36.66 LF
8" PVC
@ 0.50%
100-YR HGL
8" W8" W8" W8" W
15
"
S
S
8"
W
12" SS 12" SS12" SS12" SS12" SS12" SS
H2
O
S W
S W
S
W
S
W WWWWWWWWW
LO
T
4
BLDG 36
LO
T
1
LO
T
2
LO
T
3
LO
T
5
LO
T
6
LO
T
7
LO
T
8
LO
T
9
LO
T
1
0
LO
T
1
1
LO
T
1
2
NORTHERN LIGHTS DRIVE
EXISTING
STORM DRAINTIE INTO EXISTING
24" RCP STORM
STORM DRAIN A3
SEE SHEET ST3
STORM DRAIN A4
SEE THIS SHEET
37.94 LF
24" RCP
@ 1.68%
MH A2
STA 11+48.94
N: 105935.10
E: 215174.05
102.09 LF 24" RCP @ 0.41%
177.67 LF 18" RCP @ 0.60%
MH A4
STA 14+28.70
N: 106214.77
E: 215180.84
51
'
R
O
W
30
'
F
L
-
F
L
MH A4
STA 10+00.00
N: 106214.77
E: 215180.84
88
.
0
9
L
F
1
2
"
R
C
P
@
0
.
5
0
%
AREA INLET A4-1
STA 10+88.09
N: 106212.64
E: 215268.91
PROPERTY
CORNER
N:105937.28
E:215189.61
MH A3
STA 12+51.03
N: 106037.16
E: 215176.53
MH A1.5
STA 10+49.00
N: 105835.19
E: 215171.63
99.94 LF 24" RCP @ 0.38%
EXMH A1
STA 10+11.06
N: 105797.26
E: 215170.71
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
KEYMAP
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DECK
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DEC
K
DEC
K
DECK
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DECK
COV
E
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DECK
DEC
K
DECK
COVE
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DEC
K
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENT
R
Y
DECK
DEC
K
DEC
K
DECK
COV
E
R
E
D
ENT
R
Y
ENT
R
Y
COVE
R
E
D
DEC
K
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENTR
Y
DECK
DEC
K
DECK
DEC
K
COV
E
R
E
D
ENT
R
Y
ENT
R
Y
COVE
R
E
D
DECK
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENTR
Y
DEC
K
DEC
K
DEC
K
DECK
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
ST1
PL
A
N
A
N
D
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
A
&
A
4
A.
M
o
r
s
e
A.
B
o
e
s
e
1"
=
5
0
'
14
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
LEGEND:
NOTES:
W
G
T
E/T/C
S
W
SS
E
F
STORM DRAIN LINE A
PROFILE SCALE:PROFILE SCALE:
STORM DRAIN LINE A4
PROFILE SCALE:
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
STORM A
STORM
A4
LI
N
E
MA
T
C
H
ST
A
14
+
5
0
LINE
MATCH STA
14+50
1
1
RECORD DRAWING
UD
STORM DRAIN A2
SEE THIS SHEET
90.00 LF 12" HDPE @ 0.50%
AREA INLET A2-2.1
STA 10+90.00
N: 106028.64
E: 215028.91
MH A2-2
STA 10+00.00
N: 105938.67
E: 215026.72
BLDG 12
BLDG 13
LO
T
9
LO
T
1
0
BLDG 14
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+0012+0013+00
47.21 LF
30"x19" ELLIPTICAL RCP
@ 0.74%
100.17 LF 24" HDPE @
0
.
7
6
%
STA.=10+10.00
INV.= 4887.09
8" PVC SANITARY
8" WATER
LOWERING PER DETAIL 203
STA.=10+20.00
TOP=4889.80
18" MIN
EXISTING
GROUND
PROPOSED
GRADE
85.37 LF
12" HDPE
@ 0.50%
MH
A
2
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
6
.
3
±
IN
V
.
I
N
4
8
9
1
.
0
1
(
N
)
IN
V
.
I
N
4
8
9
1
.
4
3
(
W
)
IN
V
.
O
U
T
4
8
9
0
.
9
1
(
S
)
MH
A
2
-
2
ST
A
1
1
+
4
7
.
3
7
RI
M
4
8
9
7
.
9
±
IN
V
.
I
N
4
8
9
3
.
3
2
(
W
)
IN
V
.
I
N
4
8
9
3
.
3
2
(
N
)
IN
V
.
O
U
T
4
8
9
2
.
6
2
(
E
)
AR
E
A
I
N
L
E
T
A
2
-
3
ST
A
1
2
+
3
2
.
7
4
FL
.
E
L
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
5
.
9
8
(
W
)
IN
V
.
O
U
T
4
8
9
3
.
7
5
(
E
)
AR
E
A
I
N
L
E
T
A
2
-
1
ST
A
1
0
+
4
7
.
2
1
FL
.
E
L
4
8
9
6
.
6
±
IN
V
.
I
N
4
8
9
1
.
8
6
(
W
)
IN
V
.
I
N
4
8
9
4
.
5
6
(
N
)
IN
V
.
O
U
T
4
8
9
1
.
7
8
(
E
)
PUBLIC
STORM
SEWER
PRIVATE
STORM
SEWER
ROW
100-YR HGL
12
"
S
S
12
"
S
S
H2O
S
W
UD UD
W
MH A2
STA 10+00.00
N: 105935.10
E: 215174.05
AREA INLET A2-3
STA 12+32.74
N: 105940.74
E: 214941.38 STORM DRAIN A
SEE SHEET ST1
AREA INLET A2-1
STA 10+47.21
N: 105936.24
E: 215126.86
47.21 LF
30"x19" ELLIPTICAL RCP
@ 0.74%
85.37 LF
12" HDPE
@ 0.50%
100.17 LF 24" HDPE @ 0.76%
MH A2-2
STA 11+47.37
N: 105938.67
E: 215026.72
BLDG 12
BLDG 13
LOT 11
LOT 12
BLDG 14 S
8"
W
12
"
S
S
BR
O
O
K
F
I
E
L
D
D
R
I
V
E
MH A2-2
BLDG 12
LOT 9
LOT 10
LOT 11
45° BEND W/ C/O A2-2.3
STA 12+12.82
N: 106040.31
E: 214908.07
45° BEND W/ C/O A2-2.2
STA 11+12.81
N: 106037.88
E: 215008.05
22.82 LF
8" PVC
@ 0.40%
100.01 LF 8" PVC @ 0.40%27.09 LF
8" PVC
@ 0.40%AREA INLET A2-2.1
STA 10+90.00
N: 106028.64
E: 215028.91
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+0012+0013+0014+0014+50
90.00 LF
12" HDPE
@ 0.50%
EXISTING
GROUND
PROPOSED
GRADE
27.09 LF
8" PVC
@ 0.40%
22.82 LF
8" PVC
@ 0.40%
100.01 LF
8" PVC
@ 0.40%
MH
A
2
-
2
ST
A
1
1
+
4
7
.
3
7
RI
M
4
8
9
7
.
9
±
IN
V
.
I
N
4
8
9
3
.
3
2
(
W
)
IN
V
.
I
N
4
8
9
3
.
3
2
(
N
)
IN
V
.
O
U
T
4
8
9
2
.
6
2
(
E
)
AR
E
A
I
N
L
E
T
A
2
-
2
.
1
ST
A
1
0
+
9
0
.
0
0
FL
.
E
L
4
8
9
7
.
4
±
IN
V
.
I
N
4
8
9
3
.
8
8
(
N
W
)
IN
V
.
O
U
T
4
8
9
3
.
7
7
(
S
)
45
°
B
E
N
D
W
/
C
/
O
A
2
-
2
.
2
ST
A
1
1
+
1
2
.
8
1
RI
M
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
3
.
9
7
(
W
)
IN
V
.
O
U
T
4
8
9
3
.
9
7
(
S
E
)
45
°
B
E
N
D
W
/
C
/
O
A
2
-
2
.
3
ST
A
1
2
+
1
2
.
8
2
RI
M
4
8
9
9
.
8
±
IN
V
.
I
N
4
8
9
4
.
3
7
(
N
W
)
IN
V
.
O
U
T
4
8
9
4
.
3
7
(
E
)
12
"
I
N
L
E
T
A
2
-
2
.
4
ST
A
1
2
+
3
9
.
9
1
FL
.
E
L
4
8
9
7
.
0
±
IN
V
.
I
N
4
8
9
4
.
4
8
(
N
E
)
IN
V
.
O
U
T
4
8
9
4
.
4
8
(
S
E
)
PRIVATE STORM SEWER
117.66 LF
4" PVC
@ 1.00%
C/
O
A
2
-
2
.
6
ST
A
1
3
+
7
6
.
3
9
RI
M
4
8
9
8
.
6
±
IN
V
.
O
U
T
4
8
9
5
.
8
4
(
S
)
18.82 LF
4" SLOTTED PVC
@ 1.00%
C/
O
A
2
-
2
.
5
ST
A
1
2
+
5
8
.
7
2
RI
M
4
8
9
7
.
2
±
IN
V
.
I
N
4
8
9
4
.
6
6
(
N
)
IN
V
.
O
U
T
4
8
9
4
.
6
7
(
S
W
)
100-YR HGL
2.24'
H2
O
H2
O
S
S
8" W8" W
HYD
WV
WV
WV
W
8" W8" W
12" SS12" SS12" SS
V.
P
.
12" INLET A2-2.4
STA 12+39.91
N: 106059.92
E: 214889.39
C/O A2-2.5
STA 12+58.72
N: 106075.78
E: 214899.51
18.82 LF
4" SLOTTED PVC
@ 1.00%
C/O A2-2.6
STA 13+76.39
N: 106193.42
E: 214897.06
117.66 LF
4" SLOTTED PVC
@ 1.00%
BROOKFIELD DRIVE
BLDG 11
TRACT A
BLDG 10 No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
KEYMAP
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DECK
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DEC
K
DEC
K
DECK
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DEC
K
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DECK
DECK
DEC
K
DECK
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DECK
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENT
R
Y
DECK
DEC
K
DEC
K
DECK
COVE
R
E
D
ENT
R
Y
ENT
R
Y
COVE
R
E
D
DEC
K
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENT
R
Y
ENT
R
Y
COVE
R
E
D
DECK
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DEC
K
DEC
K
DECK
ST2
PL
A
N
A
N
D
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
A
2
&
A
2
-
2
A.
M
o
r
s
e
A.
B
o
e
s
e
1"
=
5
0
'
15
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
STORM DRAIN LINE A2
PROFILE SCALE:PROFILE SCALE:
STORM DRAIN LINE A2-2
PROFILE SCALE:PROFILE SCALE:
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
STORM
A2-2, A2-2.1
STORM
A2
LEGEND:
NOTES:
W
G
T
E/T/C
S
W
SS
E
F
1
RECORD DRAWING
CT
V
X
S
W
12'' INLET A5-1
STA 10+55.01
N: 106329.42
E: 215231.81
6.28 LF
4" PVC
@ 0.40%
22.5° BEND W/ C/O A5-1-1
STA 10+06.28
N: 106334.09
E: 215227.60
43.53 LF
4" SLOTTED PVC
@ 0.40%
12'' INLET A5-1
STA 10+55.01
N: 106329.42
E: 215231.81
51
'
R
O
W
30
'
F
L
-
F
L
BLDG 35
STORM DRAIN A-5
SEE THIS SHEET
STORM DRAIN A
SEE SHEET ST1
C|O A5-1-2
STA 10+49.82
N: 106377.56
E: 215229.81
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+2510+0011+00
43.53 LF
4" SLOTTED PVC
@ 0.40%
6.28 LF
4" PVC
@ 0.40%
EXISTING
GROUND
PROPOSED
GRADE
C|
O
A
5
-
1
-
2
ST
A
1
0
+
4
9
.
8
2
RI
M
4
8
9
6
.
9
±
IN
V
.
O
U
T
4
8
9
4
.
9
0
(
S
)
22
.
5
°
B
E
N
D
W
/
C
/
O
A
5
-
1
-
1
ST
A
1
0
+
0
6
.
2
8
RI
M
4
8
9
6
.
9
±
IN
V
.
I
N
4
8
9
4
.
7
3
(
N
)
IN
V
.
O
U
T
4
8
9
4
.
7
3
(
S
E
)
12
'
'
I
N
L
E
T
A
5
-
1
ST
A
1
0
+
5
5
.
0
1
FL
.
E
L
4
8
9
7
.
5
±
IN
V
.
I
N
4
8
9
2
.
5
6
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
7
0
(
N
W
)
IN
V
.
O
U
T
4
8
9
2
.
5
6
(
S
W
)
PRIVATE STORM SEWER
1.78'
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+50 10+00 11+00 11+50
55.01 LF
8" PVC
@ -0.50%
EXISTING
GROUND
PROPOSED
GRADE
6.04 LF
8" PVC
@ 0.50%
DR
Y
W
E
L
L
A
5
-
2
ST
A
1
0
+
6
1
.
0
5
GR
A
T
E
/
R
I
M
.
E
L
4
8
9
8
.
2
±
SU
M
P
4
8
8
3
.
1
2
IN
V
.
O
U
T
4
8
9
2
.
5
3
(
S
W
)
MH
A
5
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
8
.
1
±
IN
V
.
I
N
4
8
9
3
.
3
3
(
W
)
IN
V
.
I
N
4
8
9
2
.
8
3
(
N
E
)
IN
V
.
O
U
T
4
8
9
3
.
3
3
(
S
)
12
'
'
I
N
L
E
T
A
5
-
1
ST
A
1
0
+
5
5
.
0
1
RI
M
4
8
9
7
.
5
±
IN
V
.
I
N
4
8
9
2
.
5
6
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
7
0
(
N
W
)
IN
V
.
O
U
T
4
8
9
2
.
5
6
(
S
W
)
PRIVATE
STORM
SEWER
PUBLIC
STORM
SEWER
ROW
ST
A
1
0
+
5
5
.
0
1
RI
M
4
8
9
7
.
5
±
S
S
W
S
UD
W
W
W
W
51' R
O
W
30' FL-
F
L
BLDG 35
LOT
1
LOT
2
12'' DRAIN BASIN A5-1
STA 10+55.01
N: 106329.42
E: 215231.81
STORM DRAIN A
SEE SHEET ST1
MH A5
STA 10+00.00
N: 106304.03
E: 215183.01
DRYWELL A5-2
STA 10+61.05
N: 106332.21
E: 215237.17
STORM DRAIN A-5-1
SEE THIS SHEET
STORM DRAIN A6
SEE THIS SHEET
55.01 LF
8" PVC
@ -0.50%
6.04 LF
8" PVC
@ -0.50%
12
"
S
S
12
"
S
S
W
S
S
W
W
UD UD
W
W
W
W
W
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
SANITARY LINE A
SEE SHEET SS1
AREA INLET A3-1
STA 10+53.09
N: 106035.87
E: 215229.61
STORM DRAIN A
SEE SHEET ST1
BLDG 36
LOT 8
LOT 11
LOT 12
TRACT B
53.09 LF
12" RCP
@ 0.50%
MH A3
STA 10+00.00
N: 106037.16
E: 215176.53
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+50 10+00 11+00
53.09 LF
12" RCP
@ 0.50%
EXISTING
GROUND
PROPOSED
GRADE
MH
A
3
ST
A
1
0
+
0
0
.
0
0
RI
M
4
8
9
6
.
8
±
IN
V
.
I
N
4
8
9
1
.
6
3
(
N
)
IN
V
.
I
N
4
8
9
2
.
1
3
(
E
)
IN
V
.
O
U
T
4
8
9
1
.
4
3
(
S
)
AR
E
A
I
N
L
E
T
A
3
-
1
ST
A
1
0
+
5
3
.
0
9
FL
.
E
L
4
8
9
7
.
1
±
IN
V
.
I
N
4
8
9
5
.
0
0
(
E
)
IN
V
.
O
U
T
4
8
9
2
.
4
0
(
W
)
PRIVATE
STORM
SEWER
PUBLIC
STORM
SEWER
ROW
100-YR HGL
4880
4885
4890
4895
4900
4905
4910
4915
4880
4885
4890
4895
4900
4905
4910
4915
9+5010+0011+00
AR
E
A
I
N
L
E
T
A
6
w
/
S
N
O
U
T
ST
A
?
?
?
FL
.
E
L
4
8
9
8
.
7
±
IN
V
.
I
N
4
8
9
4
.
6
9
(
N
E
)
IN
V
.
I
N
4
8
9
4
.
6
9
(
W
)
IN
V
.
I
N
4
8
9
6
.
5
0
(
S
)
IN
V
.
O
U
T
4
8
9
3
.
6
2
(
E
)
IN
L
E
T
A
6
-
1
ST
A
1
0
+
2
9
.
3
5
RI
M
4
8
9
8
.
0
±
IN
V
.
O
U
T
4
8
9
4
.
8
6
(
S
W
)
28.08 LF
12" RCP
@ 0.60%
100-YR HGL
EXISTING
GROUND
PROPOSED
GRADE
ST
A
1
0
+
0
0
.
0
0
2.68'
S
S
W
S
UD
W
W
W
W
51' R
O
W
30' FL-
F
L
LOT
1
LOT
2
LOT
3
STA 10+00.00
STORM DRAIN A
SEE SHEET ST1
INLET A6-1
STA 10+29.35
N: 106322.88
E: 215158.46
28.08 LF
12" RCP
@ 0.60%
AREA INLET A6 w/ SNOUT
STA ???
N: 106305.18
E: 215135.69
No
.
Re
v
i
s
i
o
n
s
:
By
:
Da
t
e
:
RE
V
I
E
W
E
D
B
Y
:
R.
B
a
n
n
i
n
g
DE
S
I
G
N
E
D
B
Y
:
DR
A
W
N
B
Y
:
SC
A
L
E
:
DA
T
E
:
Ju
n
e
1
5
,
2
0
1
6
PR
O
J
E
C
T
:
37
4
-
0
2
0
Sheet
Of 38
BR
O
O
K
F
I
E
L
D
S
E
C
O
N
D
R
E
P
L
A
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
KEYMAP
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DECK
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DEC
K
DEC
K
DECK
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DEC
K
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENTRY
ENTR
Y
COV
E
R
E
D
DECK
COVE
R
E
D
ENTRY
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DECK
DECK
DEC
K
DECK
COV
E
R
E
D
ENTR
Y
ENTR
Y
COV
E
R
E
D
DECK
COV
E
R
E
D
ENTR
Y
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENT
R
Y
DECK
DEC
K
DEC
K
DECK
COVE
R
E
D
ENT
R
Y
ENT
R
Y
COVE
R
E
D
DEC
K
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENTR
Y
COV
E
R
E
D
ENTR
Y
DECK
DECK
DECK
DEC
K
COVE
R
E
D
ENT
R
Y
ENT
R
Y
COVE
R
E
D
DECK
COVE
R
E
D
ENT
R
Y
COVE
R
E
D
ENTR
Y
COVE
R
E
D
ENTR
Y
DEC
K
DEC
K
DEC
K
DECK
ST3
PL
A
N
A
N
D
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
A
3
,
A
5
&
A
5
-
1
A.
M
o
r
s
e
A.
B
o
e
s
e
1"
=
5
0
'
16
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
PROFILE SCALE:
STORM
A3
STORM DRAIN LINE A5
PROFILE SCALE:
STORM
A5,
A5-1, A6
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
PROFILE SCALE:
STORM DRAIN LINE A3
LEGEND:
NOTES:
W
G
T
E/T/C
S
W
SS
E
F
STORM DRAIN LINE A6
PROFILE SCALE:
STORM DRAIN LINE A5-1
NO
R
T
H
E
R
N
L
I
G
H
T
S
D
R
I
V
E
STORM DRAIN A-5
SEE THIS SHEET
CONTRACTOR TO INSTALL AND MAINTAIN
PLUG IN A5 & A5-1 ON NORTHEAST 8"
OUTFALL LINE DURING CONSTRUCTION.
PUMP AND LEGALLY DISPOSE OF
EFFLUENT, THEN REMOVE PLUG AS SOON
AS SITE IS ESTABLISHED
RECORD DRAWING
1/19 Page 1 of 2
DURING CONSTRUCTION INSPECTION CHECKLIST
To be completed by Construction Superintendent
This checklist is to be completed during construction and included with the Overall Site and Drainage Certification.
Use “Yes” for items completed as described.
Use “N/A” for items that are not applicable to the site being certified.
If any blanks are “No,” attach an explanation referencing the item number below.
Project Name: Morningside Date: 08/26/2021
Building Permit Numbers: N/A
I. Compaction
A.Yes All berms and embankments meet the compaction requirements as specified in the project geotechnical report or comply with the
City’s standard, which is “soils should be compacted within a moisture content range of 2% below to 2% above optimum moisture content
and compacted to 95% of the Maximum Standard Proctor Density (ASTM D698).” Compaction requires verification during construction.
Provide testing log from contractor/engineer.
II. Storm Drain Pipe Installation Requirements
A.Yes The pipe trenches have been compacted in accordance with Section 02225-3.07.A.1. of the Fort Collins Development Construction
Standards for Water, Wastewater, Stormwater (e.g., the trenches in the roadways are to be 95% of maximum density and all other areas
are to be at 90%, both in accordance with ASTM D698).
III.Energy Dissipation and Erosion Protection - FCSCM Chapter 9, Section 7.0
A.Riprap
1. Yes The riprap bedding is a granular bedding of the gradation and thickness indicated on the approved construction plans.
2. N/A A filter fabric was installed instead of granular bedding and is the material shown on the approved construction plans or was an
approved equal. Provide documentation for an approved equal.
3. N/A The riprap is the gradation shown on the approved construction plans with a D50 of .
4. N/A The riprap thickness is as shown on the approved construction plans and extends to the horizontal limits shown.
5. N/A The riprap is buried to the depth indicated on the approved construction plans. (A minimum of 6 inches of soil is required.)
B. Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7
1. N/A All fabric was installed per manufacturer’s specifications.
1/19 Page 2 of 2
IV. Other Permanent BMPs
A.N/A All cut-off walls have been installed in accordance with the approved construction plans. (Cut-off walls are required for irrigation ditch
crossings of storm drain pipes.)
V.Extended Detention Basins
A.N/A Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the water quality
control box(es). Provide date of inspection and name of inspector:
Included certification sheet(s):
Please check the appropriate box(es) for the Low Impact Development
(LID) facilities found on this site and complete the corresponding
certification sheets.
☐ Permeable Interlocking Concrete Pavers
☒ Bioretention Cells (Rain Gardens)
☐ Sand Filters
☐ Vegetated Buffers
☐ Underground Infiltration
☐ Other LID – For certification of Dry Wells, Tree Filters,
Constructed Wetland Channels & Ponds, etc., contact City Staff
to determine requirements to exhibit the LID facility has been
constructed and functions as intended per the approved
drainage report.
*Please provide photographic documentation of the installation of all
stages of all LID facilities.
**Please contact the City Stormwater Inspector at
stormwaterinspection@fcgov.com to discuss inspection requirements
for each LID facility and request inspections.
***All facilities being certified must be “clean” – free of sediment &
construction debris – prior to certification or acceptance of the facility.
Completed by:
Name: Shawn Lear
Title: Superintendent
Email: slear@mylandmarkhomes.net
Phone: 970-388-2979
Company: Landmark Homes
Address: 6341 Fairgrounds Ave
Windsor, CO 80550
1/19 Page 1 of 4
Permeable Interlocking Concrete Pavers
Item/Activity Yes No N/A Submittal Requirements Submitted?/Response
Stormwater Inspection
Pre-construction meeting was held with City-Stormwater
Inspector to discuss installation, inspection, checklist, and
protection from sedimentation ☒☐☐
Record date, inspector name, meeting
location (i.e. DCP, initial erosion control
inspection, etc.)
Kurt Vanetta, date and
location should have
been recorded by city
inspector. Landmark
does no have record.
Sub-surface inspection(s): Installation of this facility was
verified via inspection by a City-Stormwater Inspector at the
point of installation of the outlet, underdrain, geomembrane
layer, and sub-base courses (per design in Final Plan
Documents)
☒☐☐
Record date(s) of inspection and
inspector’s name
Kurt Vanetta, date and
location should have
been recorded by city
inspector. Landmark
does no have record.
Surface inspection(s): Installation of this facility was verified via
inspection by a City-Stormwater Inspector at the point of
installation of the pavers and joint fill material ☒☐☐
Record date(s) of inspection and
inspector’s name
Kurt Vanetta, date and
location should have
been recorded by city
inspector. Landmark
does no have record.
Excavation
Heavy equipment did not encroach into the excavated area
(prevents over-compaction)☒☐☐
Bottom of cell was “ripped” after excavation
☒☐☐
Provide photographs before and after
“ripping”
Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
Bottom surface of cell is flat and level
☒☐☐
Provide photograph Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
Impermeable Liner
Impermeable liner meets design specifications ☐☐☒Provide specifications of delivered
material
Impermeable liner is attached to concrete perimeter wall ☐☐☒Provide photograph
1/19 Page 2 of 4
Impermeable liner is buried with no exposure ☐☐☒
Any penetrations of the impermeable liner have been sealed
and checked for water-tightness ☐☐☒Provide photograph (if necessary)
Edge Restraint and Concrete Cut-Off Wall
The required edge restraint meets design specifications ☐☐☒Provide specification of installation
Concrete cut-off wall meets design specifications for: ☐☐☒Provide specification of installation
- Dimensions ☐☐☒
- Reinforcement ☐☐☒
- Footings ☐☐☒
Underdrain System
Underdrain pipe meets design specifications
☒☐☐
Provide photograph Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
At least one cleanout is provided per underdrain lateral
☒☐☐
Provide photograph Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
Cleanout pipe is solid (not perforated/slotted)
☒☐☐
Provide photograph Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
Cleanout covers are installed and watertight
☒☐☐
Provide photograph Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
1/19 Page 3 of 4
Verify the underdrain is NOT wrapped in geotextile fabric
☒☐☐
Provide photograph Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
Verify there is no orifice plate on the underdrain outfall
☒☐☐
Provide photograph Limited photos
available due to time
frame past project
completion. City
Inspector present
during construction.
Underdrain integrity tested after backfilling using TV and/or
water test ☐☒☐Provide documentation of test results
Aggregate
Sub-base Course(e.g., #2/4):
- Has 90% fractured faces
- Is thoroughly washed (virtually free of fine sediment)
- Is installed to the required design depth ☒☐☐
Provide load ticket, photographs, and
record depth installed
Due to length of time
from project
completion no load
tickets, photographs or
record of depth
available. Landmark
utilized city inspector as
certifying agent.
Basecourse (e.g., #57):
- Has 90% fractured faces
- Is thoroughly washed (virtually free of fine sediment)
- Is installed to the required design depth ☒☐☐
Provide load ticket, photographs, and
record depth installed
Due to length of time
from project
completion no load
tickets, photographs or
record of depth
available. Landmark
utilized city inspector as
certifying agent.
Leveling Course / Joint Fill (e.g., crushed #89):
- Has 90% fractured faces
- Is thoroughly washed (virtually free of fine sediment)
- Is dry screened
- Is installed to the required design depth and to the top
of the paver joints
☒☐☐
Provide load ticket, photographs, and
record depth installed
Due to length of time
from project
completion no load
tickets, photographs or
record of depth
available. Landmark
utilized city inspector as
certifying agent.
1/19 Page 4 of 4
Aggregate materials are installed and compacted according to
manufacturer’s and/or design specifications
☒☐☐
Provide photographs and documentation
of compaction
No photographs other
than what is provided
due to length of time
from project
completion.
Compaction observed
by city inspector.
Protection During Construction
PICP area is protected from construction site sediment,
including runoff from the upstream catchment and
construction equipment traffic ☒☐☐
Specify how the area was covered and/or
otherwise protected to prevent
construction runoff from entering the
pavement
Installation occurred
after vertical
construction complete.
Waddles used to
protect run off routes.
Close Out
Cracked/broken paver units have been removed and replaced
☒☐☐
Area inspected by city
personnel, areas of
concern corrected and
certified by city
inspector.
Paver height offsets are no more than 1/4” between adjacent
units & surface contains no deformations
(depressions/settlement) exceeding 1/2"
☒☐☐
Upstream catchment is stabilized prior to diverting runoff into
PICP system ☒☐☐
1/19 Page 1 of 7
Bioretention Cells (Rain Gardens)
Item/Activity Yes No N/A Submittal Requirements Submitted?/Response
Stormwater Inspection
Pre-construction meeting was held with City-Stormwater
Inspector to discuss installation, inspection, checklist, and
protection from sedimentation ☒☐☐
Record date, inspector name, meeting
location (i.e. DCP, initial erosion control
inspection, etc.)
Landmark did not keep
record as city
inspectors where
utilized to record dates
and times needed for
COFC use.
Underdrain and basecourse inspection(s): Installation of this
facility was verified via inspection by a City-Stormwater
Inspector at the point of installation of the outlet, underdrain,
geomembrane layer, and base course (per design in Final Plan
Documents)☒☐☐
Record date(s) of inspection and
inspector’s name
Martha Cruz. Please
refer to MC’s reports
for additional
information. Landmark
did not receive reports
from city inspections.
Inpsectors where on
site and or notified of
construction schedule.
Pea gravel and BSM inspection(s): Installation of this facility
was verified via inspection by a City-Stormwater Inspector at
the point of installation of the pea gravel and bioretention
sand media
☒☐☐
Record date(s) of inspection and
inspector’s name
Martha Cruz. Please
refer to MC’s reports
for additional
information. Landmark
did not receive reports
from city inspections.
Inspectors where on
site and notified of
construction schedule.
Excavation
Heavy equipment did not encroach into the excavated area
(prevents over-compaction)☒☐☐
Bottom of cell was “ripped” after excavation
☒☐☐
Provide photographs before and after
“ripping”
Photos not taken or
limited as checklist
provided a year after
construction
1/19 Page 2 of 7
Bottom surface of cell is flat and level
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Excavated area is protected/surrounded by sediment/runoff
control measures during construction
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Intake
Upstream catchment drains to inlet/bioretention cell per plan
and flows are fully captured ☒☐☐
Forebay
Forebay is installed according to design specifications
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
There is a minimum 3” drop at the forebay entrance
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Forebay will drain fully and not hold standing water ☒☐☐
Outlet Structure/Overflow
1/19 Page 3 of 7
Emergency overflow elevation is confirmed
☐☐☒
Measure and record distance from
overflow to top of media filter; provide
photograph
Overflow inlet elevation is set above bioretention media per
plan
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Overflow inlet invert elevation is at least 3 inches below
containment wall/berm (to direct overflow into inlet)
☒☐☐
Measure and record distance between
inlet and top of containment wall/berm;
provide photograph
Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Overflow path and check dams, if used, are armored to protect
from erosion and maintain elevations ☐☐☒Provide photograph
Impermeable Liner
Impermeable liner meets design specifications
☒☐☐
Provide specifications of delivered
material
Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Impermeable liner is appropriately anchored
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
1/19 Page 4 of 7
Impermeable liner is buried with no exposure
☒☐☐
Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Any penetrations of the impermeable liner have been sealed
and checked for water-tightness
☒☐☐
Provide photograph (if necessary)Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Underdrain System
Underdrain pipe meets design specifications
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
At least one cleanout is provided per underdrain lateral
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
1/19 Page 5 of 7
Cleanout pipe is solid (not perforated/slotted)
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Cleanout covers are installed and watertight
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Verify the underdrain is NOT wrapped in geotextile fabric
☒☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Verify there is no orifice plate on the underdrain outfall
☐☐☐
Provide photograph Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
1/19 Page 6 of 7
Underdrain integrity tested after backfilling using TV and/or
water test
☐☐☐
Provide documentation of test results Photos not taken or
limited as checklist
provided a year after
construction. Please see
attached available
photos. City inspectors
were present and
observed construction
Filter Media and Aggregate
Reservoir aggregate layer (ASTM #57 or #67):
- meets design specifications
- is installed to the required design depth
☒☐☐
Provide load ticket, photographs, and
record depth installed
See attached load
tickets, specification
sheets and photos.
Data and photos are
limited due to
timeframe from
completion and
checklist being
completed a year after
project completion.
Diaphragm aggregate layer (“Pea Gravel” with gradation ASTM
#8, #89, or #9):
- meets design specifications
- is installed to the required design depth
☒☐☐
Provide load ticket, photographs, and
record depth installed
See attached load
tickets, specification
sheets and photos.
Data and photos are
limited due to
timeframe from
completion and
checklist being
completed a year after
project completion.
Bioretention Sand Media (BSM) composition:
- meets design specifications
- is installed to the required design depth
☒☐☐
Provide load ticket, photographs, and
record depth installed
See attached load
tickets, specification
sheets and photos.
Data and photos are
limited due to
timeframe from
completion and
checklist being
completed a year after
project completion.
1/19 Page 7 of 7
BSM was “machine mixed” by supplier prior to delivery
☒☐☐
Provide load ticket See attached load
tickets, specification
sheets and photos.
Data and photos are
limited due to
timeframe from
completion and
checklist being
completed a year after
project completion.
BSM is installed flat and level ☒☐☐Provide photograph
Other Structural Components
Containment wall/berm is continuous and level ☒☐☐
Landscaping
Verify final landscaping is free of sod ☒☐☐If sod is used, it must be shown to be
“sand-grown”
Final landscaping (non-floatable mulch) is flat and level ☐☐☒Provide photograph
Vegetation is planted according to landscape design
specifications and final landscaping plan
☒☐☐
Provide photograph See attached load
tickets, specification
sheets and photos.
Data and photos are
limited due to
timeframe from
completion and
checklist being
completed a year after
project completion.
Verify that weed barrier is NOT installed ☒☐☐
Temporary irrigation installed
☒☐☐
If N/A, then verify that permanent
irrigation is installed to establish/maintain
vegetation
Close Out
Upstream catchment stabilized prior to diverting runoff into
bioretention cell ☒☐☐
1/19 Page 1 of 1
Vegetated Buffers
Item/Activity Yes No N/A Submittal Requirements Submitted?/Response
Construction
Buffer area was sectioned off to eliminate site disturbance and
compaction during construction ☐☐☒Provide photograph(s)
Level spreader has been installed per plan (if applicable)☐☐☒Provide photograph
Soils in the buffer area have been amended ☐☐☒Record soil amendment certification with
Environmental & Regulatory Affairs
Vegetation is planted according to landscape design
specifications and final landscaping plan ☐☐☒Provide photograph
11/18 Page 1 of 4
Dry Wells
was held with City-Stormwater
Inspector to discuss installation, inspection, checklist, and
protection from sedimentation
☐ ☐ ☒
location (i.e. DCP, initial erosion control
inspection, etc.)
date or inspector due
to time after
completion and
personnel changes. City
Inpectors where
present during
Sub-surface inspection(s):
verified via inspection by a City-Stormwater Inspector at the
point of excavation and installation of perforated structure,
aggregate, and underdrain connection (per design in Final Plan
Documents) ☐ ☐ ☒
inspector’s name date or inspector due
to time after
completion and
personnel changes. City
Inpectors where
present during
Surface inspection(s):
via inspection by a City-Stormwater Inspector
☐ ☐ ☒
inspector’s name date or inspector due
to time after
completion and
personnel changes. City
Inpectors where
present during
Excavation
(diameter/width) specified in the Final Plan Documents, or to
well-draining soils
☒ ☐ ☐
excavation available due to the
time frame that has
passed from project
completion. Depth can
be verified with as-
builts EOR observation
City Inpectors where
present during
11/18 Page 2 of 4
Heavy equipment did not encroach into the excavated area
(prevents over-compaction) ☐ ☒ ☐
Structure
☒ ☐ ☐
structure installed and EOR observation.
Photographs not
available due to time
frame passed from
Inpectors where
present during
the Final Plan Documents
☒ ☐ ☐
and EOR observation.
Photographs not
available due to time
frame passed from
Inpectors where
present during
surface)
☒ ☐ ☐
“ripping” and EOR observation.
Photographs not
available due to time
City Inpectors where
present during
construction. frame
passed from project
Aggregate / Backfill
according to design specifications included in the Final Plan
Documents
☒ ☐ ☐
of compaction reports/photographs
not available due to
length of time from
projec
Inpectors where
present during
11/18 Page 3 of 4
Aggregate material within the dry well structure is installed and
compacted according to design specifications included in the
Final Plan Documents
☒ ☐ ☐
of compaction reports/photographs
not available due to
length of time from
Inpectors where
present during
Underdrain System
☒ ☐ ☐
than what EOR has
provided not available.
City Inpectors were
present during
☒ ☐ ☐
than what EOR has
provided not available.
City Inpectors were
present during
☒ ☐ ☐
than what EOR has
provided not available.
City Inpectors were
present during
☒ ☐ ☐
than what EOR has
provided not available.
City Inpectors were
present during
☐ ☒ ☐
Protection During Construction
11/18 Page 4 of 4
Dry well area is protected from construction site sediment,
including runoff from the upstream catchment and
construction equipment traffic ☒ ☐ ☐ otherwise protected to prevent
construction runoff from entering the dry
waddle was used to
protect inlet.
Close Out
☒ ☐ ☐
From:aquest@mylandmarkhomes.net
To:Dan Mogen
Cc:Danny Weber
Subject:[EXTERNAL] Morningside Rain Garden Documents and narrative for missing inspection requirements
Date:Thursday, August 19, 2021 9:52:44 AM
Attachments:image001.png
Morningside Rain Garden Photos.zip
Morningside Drywell Photos.zip
Rain Garden.pdf
img20210203_13331317.pdf
374-020_Utility As Built_Phase 1.pdf
Good morning Dan,
I’m writing as a follow up to our conversation regarding certification of the rain gardens at our
Morningside development. Per our conversation we have missing and incomplete documentation
that the City of Fort Collins requires for release of bond or escrow.
I did some investigation and attached photos, spec sheet for material used in the rain garden as well
as some truck tickets for material brought in to build the rain gardens, these are limited as the time
frame that has passed from completion to this review is substantial. It is regretful that we did not
maintain the checklist in a way the city requires but we now have a process set up to make sure we
have better communication with the appropriate inspectors and certifying personnel for future
projects.
Regarding the construction of the rain gardens and speaking with the Site Superintendent and the
trade who installed the system I am confident that we built a system that works as designed. Please
see attached documents to help support my statement of working system. I am aware that not all
documents are available that you would like to see but I believe the city inspectors that were in
observation during construction do not have any hesitation to suggest the delivered systems are not
satisfactory.
Please let me know if you have any questions or concerns please let me know.
Andrew Quest
Land Development Superintendent
970-388-5311
aquest@mylandmarkhomes.net