HomeMy WebLinkAboutLot Certifications - 09/18/2023 7200 South Alton Way, Suite C400
Centennial, CO 80112
303-740-9393 Fax 303-921-7320
3930 Sinton Road, Suite 219
Colorado Springs, CO 80907
719-593-2593 Fax 303-921-7320
X 2900 South College Avenue, Suite 3D
Fort Collins, CO 80525
970-491-9888 Fax 303-921-7320
MEMORANDUM
To:City of Fort Collins, Bldg Dept.
From:Joey Frank, PE
Date:09-13-2023
Subject:718 Greenfields Drive – Drainage Certificate Supplement
Certification of Lot Grading - Supplement
There is currently runoff from Lot 1, Block 2 (718 Greenfields Drive) draining south onto Lot 2, Block 2 (712
Greenfields Drive). This does not align with the approved grading plan and will be remedied at the time of the
foundation construction for 712 Greenfields Drive. Until that building foundation is built there is not sufficient
soil to redirect the runoff along the shared property line as shown on the approved grading plan. The final
grades between these lots will provided with the 712 Greenfields Drive drainage certification to ensure the
intent of the approved grading plan has been met.
Item:
3. Not all elevations are within 0.2’ of the approved grading plans, but the drainage intent has been met
without negative impacts to adjoining properties.
4. All grades surrounding structures are at least 6’’ (0.5’) below TOF, except at the front concrete patio
where the grades are +/- 4’’ (.33’) below TOF.
11. It is industry standard to certify the grades prior to landscape installation. The landscaping was not
complete at time of survey. Landscaping or temporary seeding/erosion control should be installed as soon as
possible to prevent erosion of the bare soil.
A Westrian Company
RE
V
I
S
E
D
C
-
3
2
0
3
7
REVISED C-3 2037
On behalf of:
N/A
N/A
N/A
N/A
2/2/2021
2/2/2021