Loading...
HomeMy WebLinkAboutLot Certifications - 06/22/2022 (2)Date: 4-28-2022 Subdivision: Rennat Subdivision Address: 1608 FOGGY BROOK DRIVE Permit Application#: B2108559 ----------- Larimer County Parcel#: 8607139004 ----------- Lot: 4 Block: 11 ------Larimer County Reception#: 20200083075 ----------- (on development agreement) I, (print) Eric R. McDaniel a Colorado registered professional engineer, verify that construction of all stormwater facilities and grading is complete and hereby submit this certification. Please answer the following questions by initialing the appropriate response. For each question initialed "No," attach an explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots. 1. Certification includes attached Stormwater-approved grading plan. (NOTE: City's No __ Yes L Building Department does not approve grading plans). 2. Certification includes the attached as-built survey dated 4 -28-2022 (must be within 60 No __ Yes ~ days of the date the certification is submitted) accurately and truthfully depicting elevations for: • Top of foundation/finished floor • Finished grade on each side of the structure • Quarter points along each lot line (not more than 50 feet apart) • Break points/high points • Swales • Berms • Retaining walls • Air conditioning pads • Window wells • Any other appurtenance(s) within an easement 3. All elevations are within a 0.2 foot tolerance of the approved grading plan. 4. The top of foundation is at least 6 inches above the highest grade surrounding the structure. 5. There is a minimum grade of 5% away from the structure within the first 5 to 10 feet adjacent to the residence. 6. All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single family lots when the swale is draining the runoff from only two adjoining properties) and are not steeper than 33% (3:1). 7. All flow lines of stormwater drainage swales are a minimum of 6 inches below the elevation of ground adjacent to the structure and will direct drainage as shown on the Stormwater-approved grading plan. 8. All downspout location~ and discharge directions are shown on the as-built survey. 2/14/17 Runoff is directed into an appropriate drainage system or lot line swale, and it is not directed onto neighboring properties. No No No Yes (_ Yes {_ _,, Yes (__ No __ Yes k No Yes ~ No __ Yes k Page 1 Stephen Agenbroad 6/22/2022 9. A smooth transition with no vertical offset (step) in grade is provided at the lot line to all No Yes L adjacent properties. 10. The grading of this lot does not adversely affect neighboring properties or City No Yes k infrastructure. 11. Landscaping has been completed prior to survey. If not, please indicate who will be No _L_ves __ responsible for completing landscaping: _o_re_a_m_F_in_d_er_s_H_om_es ________ _ 12. Final site cleanup has been completed. No __ Yes ~ No __ Yes ~ 13. I personally visited the site as part of the certification process, and in my professional opinion, the as-built survey is an accurate representation of the site conditions. 14. Based on this information, I certify that (check one): D The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). ~he elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the approved drainage plan. PE Stamp Sign and date Name: Eric McDaniel Email: emcdaniel@emkc.com Phone: 303-694-1520 Company: EMK Consultants , Inc . Address: 7006 s. Alton Way, Bldg . F Centennial, CO 80112 NOTE: A complete certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, including, but not limited to, drawings of the lot/site showing the approved design and as-built surveyed elevations of all structures, drainage and grading features, written information/explanation of discrepancies, and other information necessary to confirm the above certification to: Email (preferred) WaterUtilitiesEng_@ftgov.com 2/14/17 Mailing Address Fort Collins Utilities ATTN: Water Utilities Engineering 281 North College Avenue Fort Collins, CO 80521 Questions? 970-221-6700 h otyot ~tColli ns ~ Page2 LAND DEVELOPMENT 1H EMK CONSULTANTS, INC. ENGINEERINGt'!JSURVEYING SERVICES AND SOLUTIONS www.EMKC.corn 7006 SOUTH ALTON WAY, BLDG . F CENTENNIAL, COLORADO 80112-2019 (303)694-1520 GRADING PERFORMANCE CERTIFICATE TRACT A <~ ~~ sa.,~~ ~~/ / 4 (::iy / A~> ~~s ~-~ ~- 5E,.9 ~~s ~~< • <I #1608 1 STORY STONE & FRAME HOUSE 0 en n 6~3x ~1/ ◊ sa_ ~I GRAPHIC SCALE 0 10 20 30 ---INCH = 20 FEET --\ ~ \ 5 3 TOF=69.9 FINISHED FLOOR= 71.1 ~171~ H.P.= HIGH POINT TOF = TOP OF FOUNDATION U.E. = UTILITY EASEMENT W.W. = WINDOW WELL □=UTILITY PEDESTAL ~ = AIR CONDITIONING 5E,.2. 0----= ROOF DRAIN AND DIRECTION "¾'-' .~ 10 .0· ~.4 ~-. 6.< 4 '.t>\ . ·. ·. -~\ ,& 0 ~ Q?-~x.. LEGAL DESCRIPTION & ADDRESS: 1608 FOGGY BROOK DRIVE, LOT 4, BLOCK 11, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO GRADING PERFORMANCE CERTIFICATE 56,'1- "' ~ :.· RENNAT s,y~~'l'~JQfii ,,,, RE 111' ~,,,, ...._\}O G le-~10,, § : ~ 38~5 -,....~. ~ -\· . -'; • ~~Mlch.:191 ~ ·. .· ~~ ~ • QJI!\. ~ ~ • "41chaet s.~¢1 0..: '. • ft• ~ .... ,;, I tli,. . . . ~~,':"""" I HEREBY CERTIFY THAT THE ELEVATIONS AND GRADING PATTERN HEREON WERE DEVELOPED FROM A SURVEY OF THE ABOVE DESCRIBED PROPERTY, PERFORMED ON THE DATE OF SURVEY SHOWN AND ACCURATELY AND TRULY DEPICT THE ELEVATIONS AS THEY EXISTED ON THE DATE OF SAID SURVEY. THE RELATIVE ELEVATIONS AS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREOF, DUE TO THE MOVEMENT OF SOIL, ADDITION OR REMOVAL OF SOIL AND/OR OTHER MATERIALS BY ACTS OF MAN, EROSION, WIND OR WATER OR OTHER FACTORS . THEREFORE, THIS SURVEY MAY NOT ACCURATELY DEPICT THE ELEVATIONS AND GRADING PATTERN OF THE REFERENCED PROPERTY AT ANY OTHER TIME. 111,, ....,r,q L L"~-,,,_,,_ BY : 111lf ·, ot''''' THIS SURVEY WAS PERFORiaMB1'1~0ER MY RESPONSIBLE CHARGE FOR AND ON BEHALF OF EMK CONSULTANTS , INC. DRAWN BY: AAF APPROVED BY: MSM JOB NO : 13283.00 DATE OF SURVEY: 0412a1w22 PAGE 1 OF 1 NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF THE CERTIFICATION SHOWN HEREON. THIS SURVEY WAS PERFORMED WITHOUT BENEFIT OF TITLE POLICY OR COMMITMENT AND EASEMENTS MAY EXIST THAT ARE NOT SHOWN. ALL EASEMENTS SHOWN WERE TAKEN FROM THE RECORD PLAT . THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH OR EASEMENT RESEARCH BY EMK CONSULTANTS, INC. RATHER, ALL INFORMATION REGARDING TITLE AND EASEMENT MATTERS SHOULD BE OBTAINED FROM A TITLE COMMITMENT OR POLICY . LEGAL DESCRIPTION OBTAINED FROM CLIENT . I I I I NATURAL HABITA BUFFERZON \ \ \ \ FG=67.65 " ------ \ \ 6' UTILITY EASEMENT \ \ ~~ 1-1----==:::!::s;:- ~--+ LOC-K ---- \ \\ LOT 4 \ ® \ FG=68.44 \ TF=69.11 ■ '--.,_,_ I '--.,_,_ \ I \ LOT3 (I) G=67.65 F=68.32 ......_ LOT 1'......_ \ -------© 1, -"' FG=65.97 \ "' I \ FG=68.44 \ TF=~9.11 \ \ \ ' FG=68.61 TF=69.2 I OT ~-=~-. 201 ® LOT9 ® '......_ ......_ ......_ I F=70. LOT 10 BLOCK 1 ® FG=69.76 TF=70 . --FG=70