HomeMy WebLinkAboutLot Certifications - 06/15/2021 (2)CERTIFICATION OF LOT GRADING
Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e)
Date: ^une 14, 2821
Address: 5425 South County Road 7
Lot:______________Block:
Subdivision:________
Permit Application #: B2003477
Larimer County Parcel #: 86Q4000020
Larimer County Reception #:________
(on development agreement)
sma
I, (print) Megan L. Keefe_______________________; a Colorado registered professional engineer, verify that construction
of all stormwater facilities and grading is complete and hereby submit this certification.
Please answer the following questions by initialing the appropriate response. For each question initialed "No," attach an
explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots.
1. Certification includes attached Stormwater-approved grading plan. (NOTE: City's
Building Department does not approve grading plans).
2. Certification includes the attached as-built survey dated 06/01/2021 (must be within 60
days of the date the certification is submitted) accurately and truthfully depicting
elevations for:
• Top of foundation/finished floor
• Finished grade on each side of the structure
• Quarter points along each lot line (not more than 50 feet apart)
• Break points/high points
• Swales
• Berms
• Retaining walls
• Air conditioning pads
• Window wells
• Any other appurtenance(s) within an easement
3. All elevations are within a 0.2 foot tolerance of the approved grading plan.
• j f c f > e e : A *
4. The top of foundation is at least 6 inches above the highest grade surrounding the
structure.
5. There is a minimum grade of 5% away from the structure within the first 5 to 10 feet
adjacent to the residence.
6. All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single
family lots when the swale is draining the runoff from only two adjoining properties)
and are not steeper than 33% (3:1).
7. All flow lines of stormwater drainage swales are a minimum of 6 inches below the
elevation of ground adjacent to the structure and will direct drainage as shown on the
Stormwater-approved grading plan.
8. All downspout locations and discharge directions are shown on the as-built survey.
Runoff is directed into an appropriate drainage system or lot line swale, and it is not
directed onto neighboring properties.
No
No
Yes
Yes
No jV fV^es
No Yes
No Yes
No Yes
No Yes
No Yes
0^
0
0
2/14/17 Page 1
n/a
Legal Description: TR IN E 1/2 OF E 1/2 OF SE 1/4
4-6-68, FTC, DESC AS BEG AT PT ON E LN SE 1/4
WH BEARS N 3 37' 29" W 657.66 FT FROM SE
COR, TH W 663.29 FT M/L TO W LN OF E 1/2 OF
E 1/2 SE 1/4, TH ALG SD W LN N 3 33' 16" W
329.11 FT, E 66
/040668 - S4 T06 R68
9. A smooth transition with no vertical offset (step) in grade is provided at the lot line to all
adjacent properties.
10. The grading of this lot does not adversely affect neighboring properties or City
infrastructure.
11. Landscaping has been completed prior to survey. If not, please indicate who will be
responsible for completing landscaping: homeowner____________________________________
12. Final site cleanup has been completed.
13. I personally visited the site as part of the certification process, and in my professional
opinion, the as-built survey is an accurate representation of the site conditions.
No
No
Yes_^j^
Yes
No es
No_____Yes
No_____Yes
14. Based on this information, I certify that (check one):
□ The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached).
□ The elevations and drainage patterns of the lot/site as measured are in general conformance with the
City approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the
specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a
manner consistent with the approved drainage plan.
Dl
QA
-c
QraVV
PE Stamp
Sign and date
Name:
Email:
Phone:
Company:
Address:
Megan Keefe
meg@keefecivil.com
970-215-6808
Keefe Civil, Inc.
3125 Crockett Street
Fort Collins, Colorado 80526
NOTE: A complete certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including, but not limited to, drawings of the lot/site showing the approved design and as-built surveyed
elevations of all structures, drainage and grading features, written information/explanation of discrepancies, and other
information necessary to confirm the above certification to:
Email (preferred) Mailing Address Questions?
WaterlltilitiesEng(5>fcgov.com Fort Collins Utilities 970-221-6700
ATTN: Water Utilities Engineering
281 North College Avenue
Fort Collins, CO 80521
Fort Collins
2/14/17 Page 2
KEEFE CIVIL, INC
3125 Crockett Street
Fort Collins, Colorado 80526
(970) 215-6808
meg@keefecivil.com
June 14, 2021 Keefe Civil Project Number: 2019-024
Fort Collins Utilities
ATTN: Water Utilities Engineering
281 North College Avenue
Fort Collins, Colorado 80521
RE: 5425 South County Road 7 Certification of Lot Grading
Permit Application # B2003477
Larimer County Parcel # 8604000020
To Whom It May Concern:
The elevations and drainage patterns shown on the attached as-built elevations for a drainage
certification at 5425 South County Road 7 by Majestic Surveying (06/01/21) are in general
conformance with the City-approved grading plan by Keefe Civil (11/22/19) with the following
exception.
Item #3 on the certification of lot grading was initialed “No” because all as-built elevations are
not within 0.2 ft tolerance of the approved grading plan and the proposed pool area has not been
constructed to date. However, it is my professional judgement lot elevations and grading are
functionally adequate and equivalent to the approved drainage plan.
Please do not hesitate to reach out to me if you have any questions or comments regarding this
certification of lot grading.
Best regards,
Megan L. Keefe, PE / Manager
Keefe Civil, Inc
Enclosures
Cc: Steve Spanjer, Spanjer Homes
Steven Parks, Majestic Surveying
\,
I
,
'
,
:
,
:
,
!
r
!
:
j
N
!
:
,
I
,
.
,
,
V
A
S0
1
.
4
9
'
1
1
"
E
5
2
9
.
1
5
'
ii
i
i
i
5
E
s
s
=
i
i
i
i
i
i
i
i
i
i
i
i
i
E
d
s
9
i
i
i
i
i
i
i
i
i
i
i
i
i
i
i
E
L
+
+
S
I
E
i
i
E
|
R
E
5
s
±
i
i
i
i
i
a
s
d
i
=
i
i
i
i
i
i
i
i
i
E
5
c
k
9
-
T
i
`
i
s
3
i
i
i
i
i
i
i
i
i
K
-
5T
R
A
U
5
£
_
52
9
.
,
,
,
N0
1
.
4
5
'
0
5
"
W
X
X
X
X
X
X
X X X X
X
X
X
X
X
X X X X
SS
SS
SS
E
E
E
E
E
E
E
E
E
E
E E E
E
E
E
E
SS
SS
SS
SO
U
T
H
C
O
U
N
T
Y
R
O
A
D
7
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
SHEET
54
2
5
S
O
U
T
H
C
O
U
N
T
Y
R
O
A
D
7
KE
E
F
E
C
I
V
I
L
,
I
N
C
82
5
U
N
I
O
N
S
T
R
E
E
T
GO
L
D
E
N
,
C
O
L
O
R
A
D
O
8
0
4
0
1
(9
7
0
)
2
1
5
-
6
8
0
8
ME
G
@
K
E
E
F
E
C
I
V
I
L
.
C
O
M
GR
A
D
I
N
G
A
N
D
U
T
I
L
I
T
Y
P
L
A
N
1 OF 4