HomeMy WebLinkAboutLot Certifications - 03/18/2024 (3)Date: 03/14/20 24 Subdivision: N/A ------------
Address: 1010 West Mountain Ave. Permit Application#: _B_2_1 _08_1_1_6 ________ _
Fort Collins, CO 8 0521 Larimer County Parcel#: _9_7_11_3 _ 0 _2 _01_4 _______ _
Lot: N/A Block: N/A -------------Larimer County Reception #:_N _/A_I __________ _
(on development agreement)
I, (print) Brian A. Bruckbauer a Colorado registered professional engineer, verify that construction
of all stormwater facilities and grading is complete and hereby submit this certification.
Please answer the following questions by initialing the appropriate response. For each question initialed "No," attach an explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots.
1.Certification includes attached Stormwater-approved grading plan. (NOTE: City's No Building Department does not approve grading plans).
2.Certification includes the attached as-built survey dated � ( \'\ ( 1...., (must be within 60 No days of the date the certification is submitted) accurately and truthfully depicting
elevations for: •Top of foundation/finished floor
•Finished grade on each side of the structure•Quarter points along each lot line (not more than 50 feet apart)
•Break points/high points
•Swales•Berms•Retaining walls
•Air conditioning pads
•Window wells
•Any other appurtenance(s) within an easement
3.All elevations are within a 0.2 foot tolerance of the approved grading plan.
4.The top of foundation is at least 6 inches above the highest grade surrounding thestructure.
5.There is a minimum grade of 5% away from the structure within the first 5 to 10 feet
adjacent to the residence.
6.All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on singlefamily lots when the swale is draining the runoff from only two adjoining properties) and are not steeper than 33% (3:1).
7.All flow lines of stormwater drainage swales are a minimum of 6 inches below the
elevation of ground adjacent to the structure and will direct drainage as shown on the Stormwater-approved grading plan.
8.All downspout locations and discharge directions are shown on the as-built survey.
2/14/17
Runoff is directed into an appropriate drainage system or lot line swale, and it is not directed onto neighboring properties.
No
No
NoL
No
No
No
Yes l
Yesl
Yes l
Yes X
Yes
Yes )(
Yesl
Yesl
Page 1
Wes Lamarque
3/18/2024
As-Built Drainage Plan
(As-Built Info Shown In Red)
Scale: 1" = 10"