HomeMy WebLinkAboutSite Certifications - 02/07/2019 (2)
January 3, 2019
Mrs. Heather McDowell
City of Fort Collins
700 Wood Street
Fort Collins, Colorado 80521
RE: Stadium Apartments
Fort Collins, Colorado
Dear Heather:
This drainage certification letter is provided to verify as-constructed conditions for Stadium
Apartments. Northern Engineering completed survey work November 15, 2018, to verify general
compliance with the Final Utility Plans for Stadium Apartments, dated January 1, 2017, including
revised drawings dated 2/27/17, 4/11/17, and 9/13/17 by Northern Engineering.
Included in this drainage certification submittal are the following:
Appendix A - City of Fort Collins Overall Site and Drainage Certification Form.
Appendix B - City of Fort Collins During Construction Inspection Checklist and photographs
provided by contractor.
Appendix C - As-constructed Rain Garden A and Water Quality Pond C calculations.
Appendix D - As-constructed record drawings for Grading and Storm Drain Plan and Profile Sheets.
Appendix E – State Portal Documents.
Table 1: Pond Record Volumes
Pond
Design Water
Quality Vol. (ft3)
As-built Water
Quality Vol. (ft3)
Rain Garden A 223 296
Water Quality Pond C 81 79.2
Although Water Quality Pond C is slightly below the design volume, the design volume is achieved
at a water surface elevation of 5026.61, 0.01 feet above the design. This is nominal and
inconsequential and will still treat the stormwater before entering the storm sewer system.
We have concluded, based on the attached information and personal site inspection, that the
drainage features for the project site have been constructed in substantial compliance with the
above referenced Final Utility Plans, with the following exceptions:
• Item III.A.2: Storm Line A from Drain Basin A3 to Drain Basin A4, shown on the storm
drain profile sheet (Sheet C2.01), was constructed with a slope flowing in the opposite
direction as the design. (A slope of -2.91% was constructed.) We have re-analyzed
this storm line and compared to the hydraulic grade line. As shown in Figure 1, there is
minimal change to the 100-year HGL.
However, during Northern Engineering’s site investigation, we witnessed standing water
within Drain Basin A4 (see Figure 3). This was to be expected with the upstream invert
of the pipe 0.39’ lower than the downstream invert. Based on our analysis, the 100-
year storm will pass through the pipe, but Drain Basin A4 will require continuous
maintenance. At a minimum, sedimentation and trash will need to be removed from
Drain Basin A4 on a consistent schedule, and the entire Storm Line A will need to be
jetted annually. The removal of sediment and trash at Drain Basin A4 is dependent on
the frequency of storms and the accumulation of sediment and trash within the drain
basin.
• Item III.A.2: Storm Line A from Drain Basin A5 to Outlet Structure A6, shown on the
storm drain profile sheet (Sheet C2.01), was constructed with a slope flowing in the
opposite direction as the design. (A slope of -1.80% was constructed.) We have re-
analyzed this storm line and compared to the hydraulic grade line. As shown in Figure
1, there is minimal change to the 100-year HGL.
However, during Northern Engineering’s site investigation, we witnessed standing water
within Drain Basin A5. This was to be expected with the upstream invert of the pipe
0.16’ lower than the downstream invert. Based on our analysis, the 100-year storm
will pass through the pipe, but Outlet Structure A6 will require continuous maintenance.
At a minimum, sedimentation and trash will need to be removed from Outlet Structure
A6 on a consistent schedule, and the entire Storm Line A will need to be jetted annually.
The removal of sediment and trash at Outlet Structure A6 is dependent on the frequency
of storms and the accumulation of sediment and trash within the outlet structure;
however, Underground Pond B will help to minimize the amount of debris within Outlet
Structure.
Figure 1: Storm Line A
• Item III.A.2: Storm Line C from Drain Basin C2 to Drain Basin C3, shown on the storm
drain profile sheet (Sheet C2.02), was constructed with a slope flowing in the opposite
direction as the design. (A slope of -0.06% was constructed.) We have re-analyzed
this storm line and compared to the hydraulic grade line. As shown in Figure 2, there is
minimal change to the 100-year HGL.
• Item III.A.2: Storm Line C from Drain Basin C3 to Drain Basin C4, shown on the storm
drain profile sheet (Sheet C2.02), was constructed with a slope flowing in the opposite
direction as the design. (A slope of -0.72% was constructed.) We have re-analyzed
this storm line and compared to the hydraulic grade line. As shown in Figure 2, there is
minimal change to the 100-year HGL.
• Item III.B.2: Northern Engineering did not observe construction. Northern Engineering
was unable to verify the encasements and clearances of the storm drains.
• Item III.B.2: Northern Engineering did not observe construction. Northern Engineering
was unable to verify the construction methods and joint types for the storm drains.
• Item V.A.4: Drain Basin A4 was constructed with inverts at 5025.18 (the design is
5025.53). This exceeds the City of Fort Collins 0.20’ tolerance allowed for storm
inverts. Furthermore, during Northern Engineering’s site investigation, we witnessed
standing water within Drain Basin A4 (see Figure 3). We have re-analyzed Storm Line A
(see Figure 1), and based on our analysis, the 100-year storm will pass through the
pipe, but Drain Basin A4 will require continuous maintenance. At a minimum,
sedimentation and trash will need to be removed from Drain Basin A4 on a consistent
schedule. The removal of sediment and trash at Drain Basin A4 is dependent on the
frequency of storms and the accumulation of sediment and trash within the drain basin.
Figure 2: Storm Line C
•
• Item V.A.4: Outlet Structure A6 was constructed with an invert out at 5025.36 (the
design is 5025.57). This is within the City of Fort Collins 0.20’ tolerance allowed for
storm inverts, but the downstream pipe slopes in the wrong direction. Furthermore,
during Northern Engineering’s site investigation, we witnessed standing water within
Outlet Structure A6 (see Figure 2). We have re-analyzed Storm Line A (see Figure 1),
and based on our analysis, the 100-year storm will pass through the outlet structure,
but Outlet Structure A6 will require continuous maintenance.
As per the design, Outlet Structure A6 does not have an open grate and Underground
Pond B, immediately upstream of Outlet Structure A6, includes two isolator rows to
collect sediment and debris. Therefore, Northern Engineering recommends that Outlet
Structure A6 is checked and cleaned of debris during the normal maintenance
procedures for Underground Pond B.
• Item VII.A.5: Northern Engineering did not observe construction. Northern Engineering
was unable to verify the backfill material of the underdrains.
• Item VII.A.5: Northern Engineering did not observe construction. Northern Engineering
was unable to verify if the underdrains were or not wrapped with geotextile liner.
• Item IX.A.1: The sidewalk culvert at the northeast entrance to the building was
constructed with a “T” shape opening. Detail 3.01 on Sheet 7.03 specified a
rectangular shaped opening. We have analyzed the flows through the sidewalk culvert
for the expected 100-year storm, and the sidewalk culvert as constructed with a “T”
shaped opening will safely pass the 100-storm (see Figure 4).
Figure 3: Drain Basin A4 Ponding
•
Please feel free to contact me with any questions you may have.
NORTHERN ENGINEERING SERVICES, INC.
Frederick S. Wegert, PE
Project Engineer
Figure 4: Sidewalk Culvert at NE Entrance
APPENDIX A
OVERALL SITE AND DRAINAGE CERTIFICATION FORM
8/16 Page 1
OVERALL SITE and DRAINAGE CERTIFICATION
Commercial, Multi-Family and Subdivision Certification Form and Checklist
Project Name:
Date:
Building Permit Numbers:
(Commercial or multi-family)
Per the requirement in Fort Collins Stormwater Criteria Manual (FCSCM) Volume 1, Section 6.11, please fill in
all applicable items in this Certification Form for Commercial, Multi-Family and Overall Single Family sites.
NOTE: several items must be verified during construction. A copy of the approved grading plan must be
submitted with the as-built grading plan. (As-built elevations must be written in red next to the approved
elevations.)
•Use “Yes” for items completed as described.
•Use “N/A” for items that are not applicable to the site being certified.
•If any blanks are “No,” attach an explanation referencing the item number below.
Attach an explanation or description of the as-built condition for any items listed or for anything not listed but
shown on the approved construction plans.
Provide an as-built redline or Mylar drawing with the following:
I.Water Quality and Quantity Detention Basin Certification - FCSCM Vol.2, Ch.10
For multiple detention basins on a site, provide the following for each basin separately:
A. Volume: As-built topographic verification is attached at 1-foot (or less) contour intervals and
volume verification calculations for the water quality capture volume and the 100-year detention storage
volume.
1. Detention basin topography was prepared by a professional land surveyor registered in the state
of Colorado.
2.Both proposed and as-built contours are shown on the same plan sheet (dashed lines for
proposed and solid lines for as-built).
3.All critical spot elevations as shown on the approved construction plans have been verified and
the as-built elevations are shown on the plan sheet.
4.Stage-storage-discharge tables are provided on a separate document.
5.Verification that designed drain time is in compliance with Colorado Revised Statute § 37-92-
602(8) is attached and has been uploaded to the Statewide Compliance Portal
(tinyurl.com/COCompliancePortal) for approval. Uploaded documents must include:
a.The cover sheet from the approved drainage report
b.The stamped certification page from the approved drainage report
c.As-built topographic survey
d.Stamped certification page from the Overall Site & Drainage Certification
e.PDF output from the Stormwater Detention and Infiltration Design Data Speadsheet
8/16 Page 2
B.Water Quality and Quantity Detention Basin Grading: Attached is as-built verification that there is
a minimum 2% positive fall into the concrete trickle pans or flow-line(s) from all areas in the bottom of
the detention pond. If there is a “soft pan” in the flow-line, all areas still must meet the minimum 2%
grade requirement.
1.Low Flow: Choose one of the following detention basin low flow options as applicable:
a. Turf swale for low flow path in detention basin.
There is a minimum 2% grade in the flow-line(s) of the detention basin. The flattest as-built grade
is .
b.Concrete pan for low flow in detention basin.
There is a concrete pan installed that meets the grades as shown on the approved construction
plans. (Show as-built spot elevations.)
c.Soft pan for low flow in detention basin.
•Verify and document the soft pan material gradation, trench width and depth - to be verified
during construction by engineer. Picture documentation is preferred or engineer’s statement of
visual inspection and compliance. (Choose one below.)
o There is a soft pan with an underdrain installed that meets the design on the approved
construction plans. (Show the underdrain grades, bedding material, geotextile, spot elevations,
bends, cleanouts, etc.)
o There is soft pan installed without an underdrain but there is a type A or B soil. The soil
type must be documented by supplying verification from a registered professional geotechnical
engineer.
NOTE: Spot elevations are to be within 0.2 ft. +/-.
2. Side Slopes: The as-built side slopes of the detention basin have been calculated and are shown.
Indicate the side slope with an arrow and a numerical value (e.g., 6.25:1). The maximum slope allowed
is 4:1. Small areas of 3:1 may be acceptable, but slopes steeper than 3:1 must be stabilized or re-
graded. Provide documentation if a variance was granted for steeper slopes during the design process.
3.Spillway Certification: The following items must be field verified:
a.The location of the spillway is indicated on the as-built plan.
b.The width of the spillway is indicated on the as-built plan.
c.The elevation(s) of the spillway is shown on the as-built plan.
d.A concrete ribbon defines the location and grade of the spillway.
e.There is downstream scour protection in the spillway as per the construction plans. Indicate
type: (riprap size “D50” gradation and bedding type, geotextile, buried
riprap with inches of bury, etc.).
f.There are no obstructions in the spillway, such as trees, bushes, sidewalks, landscape
features, rocks, etc.
8/16 Page 3
4.Outlet Structure Certification
a.The orifice plate for the approved release rate is installed with the correct size and location of
the orifice.
b.The orifice plate for the water quality outlet is installed with the correct hole size, number of
rows and columns of holes.
c.The bottom hole on both the water quality and quantity outlets are at the bottom of the plate
so no water ponds in front of the plate.
d.The well screen is the correct material and is installed as shown on the construction plans.
e.100-year overflow grate elevation is . (Elev. A on detail D-46)
f.The top elevation of the water quality capture volume is . (Elev. B on detail
D-46)
g.Overflow grate is made of the correct material, has the correct bar spacing, is hinged at the
top and bolted at the bottom.
h.The bottom of the outlet box has no obstructions or misalignments that will cause it to retain
runoff water and is sloped at 2% towards outlet.
II.Channels/Swales - FCSCM Vol.1, Ch.7, Sect.3&4
A. Capacity: The as-built capacity of all the major channels and swales has been verified. They meet
or exceed capacity requirements shown in the approved drainage study for this project.
1.All swales are located within the drainage easements as shown on the construction plans.
2.Longitudinal slopes and side-slopes (cross-sections) have been verified. Design criteria requires
longitudinal slopes of 2% min. (on vegetated swales) and side-slopes no steeper than 4:1. If these
criteria are not met, the certification engineer will write a justification and propose mitigation for each
instance or have the issues corrected. If variances to these criteria have previously been approved and
are shown on the construction plans, no justification is needed.
3.As-built spot elevations on channels/swales are shown that correspond to spot elevations
shown on the approved construction plans.
4.All permanent erosion control measures are installed as shown on the approved construction
plans (e.g., drop structures, riprap, TRMs, etc.). (Include pictures and verification of the materials used
as part of this verification.)
5.All pans, curbs, storm pipes or other appurtenances appropriately tie into each other in the
system. (Pictures at tie-in points suggested.)
6.The minimum freeboard is provided for all channels and swales as shown on the approved
construction plans or as identified in the approved drainage study. (Show the freeboard provided on
the cross-sections as on the construction plan set or attached as separate documentation.)
7.The low flow portion of all channels or swales is clear of obstructions. (No landscaping, trees,
shrubs, sod, etc. infringe on the low flow portion of channels or swales.)
8/16 Page 4
III.Storm Pipes (aka storm drains) - FCSCM Vol.1, Ch.6, Sec. 4
A. Storm Drain Pipe Capacity: The as-built capacity of all pipes installed on this project has been
verified and meets or exceeds the capacity requirements shown in the approved drainage study for this
project.
1.All storm drain pipe sizes and materials have been verified and are in conformance with the
approved construction plans. (Indicate on the plan and profile sheets that they have been verified.)
Material and size substitutions must be approved prior to installation. If a pipe size or material was
changed during construction, the certification engineer must attach the approval documents or supply
them with this certification. Approval documents must include a calculation documenting the capacity
equivalency (equal or greater) of the substituted size.
2.The longitudinal slope of the pipe is as shown on the approved construction plans. The
acceptable minimum slope is 0.4%. All slopes flatter than the designed slope on the construction plans
must be justified with capacity calculations on an attached sheet.
3.The as-built invert elevations have been verified and are shown on the plan and profile sheets of
the approved construction plans.
B.Storm Drain Pipe Installation Requirements: All pipes are installed in accordance with the
approved construction plans.
1.The minimum cover requirements for all pipes have been met as shown on the approved
construction plans. These will be called out in critical locations.
2.All encasements and clearances as specified on the approved construction plans have been met.
3.Any specific joint types or construction methods specified on the approved construction plans
have been met. (List on a separate sheet and attach to this certification.)
IV.Concrete Pans - FCSCM Vol.1, Ch.7, Sec.4.1.3.4
A. Construction/Installation: All concrete pans have been constructed in accordance with the
approved construction plans.
1.The concrete pans are the correct size/width as shown on the approved construction plans.
2.The longitudinal slopes of the pans are as shown on the approved construction plans. The
certification engineer must justify or mitigate longitudinal slopes less than the minimum of 0.4% unless
a flatter slope was approved and is shown on the approved construction plans. Provide mitigation or
justification by separate document.
3.The cross-section of the pan is as shown on the construction plans. (Specifically, the pan cross-
section is “V” shaped and meets the side slope shown on the detail.)
4.The concrete pans are a minimum of 6 inches thick without reinforcement and a minimum of 4
inches thick with a minimum of 6X6-W14xW14 reinforcement per detail D20B and D20C. (Provide
documentation of the reinforcement used if different than shown on the details or on the approved
construction plans.)
5.The spot elevations shown on the concrete pan(s) have been verified and are shown on the as-
built drawings.
8/16 Page 5
V. Storm Drain Inlets - FCSCM Vol.1, Ch.6, Sec. 3
A. Construction/Installation: All storm drain inlets have been constructed in accordance with the
approved construction plans.
1.The size and type of inlets are consistent with the inlets shown on the approved construction
plan. Indicate by writing “Verified” on each inlet on the plan sheet or list on a separate document the
inlet number(s), type and size (length). If the inlet installed is other than the one on the approved
construction plan detail sheet, provide the name and source of the detail with justification for equal or
better capacity.
2.The size of the inlet opening is consistent with the approved detail. (Check height and width.)
3.The elevation of the grate (if applicable) is at the elevation shown on the street profile or as
indicated by a spot elevation on the construction plans.
4.The as-built invert elevations of all pipes entering and leaving the inlet are shown on the plan
and profile sheets within construction tolerance of 0.2 feet. If substantially different, provide
justification and capacity calculations to show the capacity is not affected or propose mitigation.
5.The as-built size of the inlet box is as shown on the construction plans or an explanation or
justification is attached.
6.All Type C, R, 13 and 16 inlet covers are stenciled or stamped with the following (or an
equivalent) designation: NO DUMPING – DRAINS TO POUDRE RIVER.
VI.Culverts - FCSCM Vol.2, Ch.9
A. Construction/Installation: All culverts have been constructed and/or installed in accordance with
the approved construction plans.
1.All culvert sizes have been verified as indicated on the as-built construction plans as correct.
2.The culvert material type for all culverts installed is as on the approved construction plans and is
indicated on the as-built plans.
3.The as-built invert “in and out” elevations have been verified and are indicated on the as-built
construction plans.
4.The culvert headwalls or wing walls have been installed as shown on the approved construction
plans. Headwalls or wing walls may be needed in the as-built conditions onsite if the slopes adjacent to
the culvert are greater than 4:1. Please note areas needing stabilization in the certification narrative.
An alternative to consider is a turf reinforcement mat (TRM).
VII.Sub-Drains
A. Construction/Installation: All sub-drains shown on the construction plans have been installed in
accordance with those plans. Sub-drains installed with the sanitary sewer are to be verified on the
sanitary sewer plan and profile sheets of the construction plans. (NOTE: Indicate any sub-drains installed
after the plans were approved on the as-built plans.)
1.The size of the sub-drains are as approved on the construction plans and are indicated on the as-
built plans.
2.The type of sub-drain, in particular the perforated and non-perforated sections of the drain, are
as indicated on the approved construction plans.
8/16 Page 6
3.The cover requirements per the construction plans are provided.
4.The cleanouts have been installed at the locations shown on the construction plans and are
accessible for cleaning. (Cleanouts can be buried a maximum of 6 inches deep with their locations
marked.)
5.The backfill materials for sub-drains are as shown on the approved construction plans. (This
includes the type, depth and width.)
6.The geo-textile liner completely wraps the sub-drain and the permeable backfill material unless
shown otherwise on the approved construction plans. (Sub-drain pipe wrapped in a sock filter material
is accepted only if approved prior to installation.)
VIII.Curb Cuts
A. Construction: All curb cut openings are constructed in accordance with the approved construction
plans.
1.The size (width) of the curb cut opening is as shown on the approved construction plans.
2.The curb cut openings tie into a downstream swale, pipe, or other appurtenances with a smooth
transition and there no obstructions such as riprap or sod impeding the flow downstream of the curb
cut.
IX.Sidewalk Culverts & Chases
A. Construction/Installation: All sidewalk culverts have been installed at the locations shown on the
approved construction plans.
1.The size (width and length) of the culverts are as shown on the approved construction plans.
2.The cover plate is a minimum 5/8-inch galvanized plate bolted to a galvanized angle iron per the
detail shown on the approved construction plans or per the City’s detail.
3.The sidewalk culvert invert “in and out” elevations have been verified and are indicated on the
as-built plans.
4.The sidewalk culvert opening is as shown on the approved construction plans or per the City’s
detail.
5.There is a smooth transition both on the inlet and outlet ends of the sidewalk culvert with no
obstructions such as riprap or sod impeding the flow into or out of the sidewalk culvert.
X. Site Grading
A. Construction: All common open spaces have been graded in accordance with the approved
construction plans.
1.The grading on all common open spaces bordering private lots has been verified as correct and
the as-built rear lot corner elevations have been shown on the as-built plans.
8/16 Page 7
2.The as-built contours for “overlot grading” are shown on the as-built construction plans for all
common open spaces, tracts, outlots, etc. If not in compliance, please attach a narrative describing the
situation for noncompliance and when it may be corrected. An escrow for overlot grading may be
required. (NOTE: Residential Lot Grading Certification is a separate process from this Overall Site
Certification. It is understood that residential lots will be brought to final grade once the foundation is
backfilled so they may be lower than the plan shows at this Overall Site Certification stage.)
3.All turf reinforcement mats (TRMs) have been installed as shown on the approved construction
plans and the slopes are stabilized.
XI.Riprap - FCSCM Vol.1, Ch.7, Sec.4.4.4.3
A. Construction: All riprap has been installed in the locations and sizes indicated on the approved
construction plans.
XII.Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7
A. Construction: All fabric has been installed in the locations and sizes indicated on the approved
construction plans.
1.All fabric was installed per the details on the approved construction plans.
XIII.Post-Construction Site Cleanup - FCSCM Vol.3, Ch.7
A. Construction: All construction debris and obstructions of any kind have been removed from
drainage paths.
1.All construction debris has been removed except in staging area(s).
2.All ruts have been smoothed out in all construction areas.
3.All areas needing reseeding have been identified and future stabilization goals have been
coordinated with the Erosion Control Inspector and in accordance with FCSCM Vol.2 Chapter 12. Note
the area needing stabilization in the narrative.
XIV.Certification of Other Permanent BMPs - FCSCM Vol.2, Ch.8, Sec.2 & FCSCM Vol.2, Ch.12
A.The construction of channel drop structures is in accordance with the approved plan both in
location, horizontal dimensions and cross-section.
XV.Certification of LID and Water Quality Facilities - FCSCM Vol.3, Ch.4
A.Attached are the During Construction Inspection Checklist for Low Impact Development (LID) and
other items to be verified during construction, along with pictures and other required documentation.
APPENDIX B
DURING CONSTRUCTION INSPECTION CHECKLIST
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXX
V.P.V.P.
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
X
X
X
X
X
X X X X X X X X
WSO
UD
UD
UD
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
X
X
X
X
UD
UD
UD
UD
UD UD UD UD UD UD
UD UD UD UD
W. LAKE STREET
4.
2
%
2.
9
%
2.
8
%
2.
2
%
3.
3
%
3.
8
%
4.
5
%
4.
5
%
32:1
2.2%
21.4%
21.7%
4:1
9.
2
%
8:1
1.1
%
6.3%
20.1%
13.1%
11
.
8
%
13
.
4
%
12
.
3
%
15.1%
4:1
4:1
3.9%
3.8
%
2.3%
2.1%
3.7
%
2.0%
3.1
%
5.6
%
6.
0
%
2.0
%
2.
0
%
2.1
%
2.0
%
2.
1
%
2.
0
%
6.
5
%
2.2%
2.2%
2.0%
2.2%
1.7%
PROPOSED 8'
ATTACHED SIDEWALK
5'
S
I
D
E
W
A
L
K
6' CROSSPAN
(EXTEND CONCRETE
TO ROW)
EXISTING 1.5' OUTFALL
CURB & GUTTER
RAMPS
2' SIDEWALK
CHASE
INLET
W/ SUMP
OUTLET BASIN W/
ORIFICE PLATE
INLET
W/ SUMP
4" PERFORATED
UNDERDRAIN
6" PERFORATED
UNDERDRAIN
AREA INLET
RAMP
OUTLET BASIN
W/ ORIFICE PLATE
2' SIDEWALK
CHASE 3' SIDEWALK
CHASE
2.0' - FLUSH
CHEEK WALL (TYP.)
RAIN
GARDEN A
UN
D
E
R
G
R
O
U
N
D
PO
N
D
D
UN
D
E
R
G
R
O
U
N
D
PO
N
D
B
UNDERGROUND
POND B
18" OUTFALL
CURB &GUTTER
18" OUTFALL
CURB & GUTTER
18" CURB &
GUTTER
18" CURB &
GUTTER
18" CURB &
GUTTER
REPLACE EXISTING
CURB & GUTTER
CROSSPAN
STAMPED CONCRETE
EXISTING CONCRETE
WALL & FENCE
EXISTING CONCRETE
WALL & FENCE
EXISTING CONCRETE
WALL & FENCE
EMERGENCY
OVERFLOW
WEIR LOCATION
EMERGENCY
OVERFLOW
WEIR LOCATION
CONCRETE
CHASE
6" PERFORATE
UNDERDRAIN
BIKE RACK STORM DRAIN LINE A
SEE SHEET C2.01
STORM DRAIN LINE B
SEE SHEET C2.02
STORM DRAIN LINE C
SEE SHEET C2.02
26.2
8
26.93
26.94
25.
9
5
26.1
8
26.91
26.8
9
28.84
28.6
4
28.8
4
29.1
6
29.9
8
30.02
30.0
4
30.4
4
30.1630.42
30.42
30.4
2
30.6
8
31.0
4
32.5032.29
32.25
31
.
8
6
32.0
2
32.2
2
31.9
7
31.7
3
31.
6
0
31.7
3
31.9
5
32.43
32.21
32.08
32.
0
8
31.41
31.19
31.5
6
30.7
1
30.9
3
30.9
9
30.93
30.7
1
30.9
9
31.21
32.70
31.4
8
30.3
5
30.6
7
30.74
30.7
1
30.4
3
26
.
5
6 26.2
9
26.21
26.48 26
.
1
0
25.7
2
25.52
25.4
4
FFE=30.00
FFE=29.00
FFE=30.00
FFE=30.00
33.06
32.9
5
28.09
29.0
0
(30
.
9
2
)
(29
.
3
8
)
(30
.
4
4
)
(27
.
0
1
)
(26
.
9
4
)
(25.2
3
)
(3
1
.
3
1
)
(30
.
9
4
)
(3
1
.
8
5
)
(32
.
3
2
)
(32
.
7
6
)
29.74
30.42
26.2
3
27
.
0
4
26.46 26.6
3
26.
6
1
26
.
0
0
(3
2
.
6
6
)
(3
2
.
5
3
)
(3
2
.
4
2
)
(32
.
2
0
)
31.9
7 31.
2
1
32
.
2
0
(29
.
7
9
)
(29
.
7
3
)
(28.43)
(27.3
7
)
32.
2
7
32.30
25
.
1
4
24
.
6
7
(26
.
6
9
)
(26
.
4
4
)
(26
.
9
8
)
27.71
31.28
28.5
0
30.00
30.00
30.00
28.98
30.00
30.00
30.00
25.7
7
35.40
35.40
32.28 32.31
8- RISERS
6 RISERS
5-RISERS28.29 5-RISERS 6-RISERS
4-RISERS
31.7
1
32.28
33.24 32.99
32.75
29.22
29.14
30.7
6
31.90
31.4
5
31.78
31.54
STAMPED CONCRETE
4.8%
31.6
0
28.65
28.04
27.
0
1
27
.
0
0
28.5
0
27
.
0
0
27.00
27.99
(3
0
.
5
0
)
(3
0
.
3
9
)
29
.
8
9
(3
0
.
1
6
)
27.
6
9
27.34
9.8%
(3
0
.
7
3
)
(31
.
0
5
)
(30
.
8
8
)
30.18
(30
.
6
7
)
31.16
31.2
532.16
32.20
31.8831.72
31.68
31.5
1
31.6
9
31.5
4
32.08
31.1
5
31.3
0
31.7
1
FLUSH
CURB
3.5%
24.
6
0
27
.
0
6
26.7
0
26.3
2
26.1
8
26.1
926.15
26.0
9
26.4
2
26.96
26.9
0
27.0
5
27.06
29.2
1
24.84
24.82
27.40
27.60
28
.
1
0
27.60
28
.
1
0
RAMP
WATER QUALITY
OUTLET STRUCTURE
WATER QUALITY
POND C
WATER QUALITY
BASIN WITH WEIR
WATER QUALITY
POND C
WATER QUALITY
BASIN WITH WEIR
WATER QUALITY
BASIN WITH WEIR
WATER QUALITY
BASIN WITH WEIR
LANDSCAPE WALL
TOW ELEVATION =5032.0
6" PERFORATED
UNDERDRAIN
RAIN GARDEN
POND A
1-7" RISERS
1-7" RISERS
1-7" RISERS
1-7" RISERS
DETAILED GRADING
SEE SHEET C3.03
DETAILED GRADING
SEE SHEET C3.03
DETAILED GRADING
SEE SHEET C3.03
DETAILED GRADING
SEE SHEET C3.03
28.14
29.
3
2
29.44
31
.
9
4
32
.
4
7
32.58
32.79
32.78
32
.
9
0
33.20
31.75
31.4
9
31.5
9
31.5
5
2' CURB CUT 2' CURB CUT
DETAILED GRADING
SEE SHEET C3.03
UPPER COURTYARD
FFE=42.00
STAIR WELL
FFE=35.50
STAIR WELL
FFE=35.50
28.6
5
28.41
35
.
5
0
35.
5
0
32.9
8
32.78
32.5
4
32.74
32.92
33.12
29.5
0
29.
5
0
29
.
0
0
28.40
29.0
3
29.3
3
29.3
3
28.08
28.5
0
27.00
27.00
28.08
29.0
0
28.90
29.10
29.3
3
29.33
RAMPRAMP
RAMP
2.5' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
1.5' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
1.0' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
2.0' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
2' CONCRETE PAN
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
b
y
a
P
r
o
f
e
s
s
i
o
n
a
l
E
n
g
i
n
e
e
r
i
n
th
e
e
m
p
l
o
y
o
f
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
RE
V
I
E
W
S
E
T
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 25
C3.00
GR
A
D
I
N
G
P
L
A
N
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
GRAPHIC SCALE:
LEGEND:
ST
4950
4:1
79.45
(79.45)
BENCHMARK/BASIS OF BEARING
NOTES:
2.0%
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROJECT DATUM: NAVD 88
BENCHMARK #1:
CITY OF FORT COLLINS BENCHMARK 29-92: APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT
RD. AND SHIELDS ST., ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK #2:
CITY OF FORT COLLINS BENCHMARK 28-92: SOUTHWEST CORNER OF WEST PROSPECT RD. AND
CENTER AVE., ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING
DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17.
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHWEST QUARTER OF SECTION 14,
TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M. AS BEARING SOUTH 89°22'14" EAST
8
RFI 284
RFI 9
RFI 9
Se
e
a
t
t
a
c
h
e
d
Se
e
a
t
t
a
c
h
e
d
Se
e
a
t
t
a
c
h
e
d
APPENDIX C
WATER QUALITY CAPTURE VOLUME
Project Title Date:
Project Number Calcs By:
Client
Pond Designation
Invert Elevation
Water Quality Volume
100-yr Detention Volume
Total Pond Volume
D = Depth between contours (ft.)
A1 = Surface Area lower contour (ft2)
A2 = Surface Area upper contour (ft2)
5027.00 297.78 0.00 0.00 0.00 0.0000
5027.20 594.67 0.20 87.55 87.55 0.00
5027.40 792.70 0.20 138.26 225.81 0.0052 WQCV
5027.50 908.12 0.10 84.98 310.79 0.0071
Elevation Depth Volume
WQCV 5027.39 0.39 0.0050
100-yr Detention 5027.00 0.00 0.0000
Overall Detention 5027.00 0.00 0.0000
Stadium Apartments November 28, 2018
1232-001 C. Snowdon
Rain Garden A
5027.00 ft
0.0050 ac-ft
0.0000 ac-ft
0.0000 ac-ft
Rain Garden A Volume
Elevation
(ft)
Surface
Area (ft2)
Incremental
Depth (ft)
Incremental
Vol. (ft3)
Total Vol.
(ft3)
Total Vol.
(ac-ft)
Calc.
Depths
()
3
**2121AAAADV++=
Project Title Date:
Project Number Calcs By:
Client
Pond Designation
Invert Elevation
Water Quality Volume
100-yr Detention Volume
Min Sc
D = Depth between contours (ft.)
A1 = Surface Area lower contour (ft2)t
A2 = Surface Area upper contour (ft2)Area/Row
No. of Rows
5025.55 4.40 0.00 0.00 0.00 0.0000
5025.60 14.93 0.05 0.46 0.46 0.0000
5025.65 23.30 0.05 0.95 1.41 0.0000
5025.70 30.55 0.05 1.34 2.75 0.0001
5025.75 37.05 0.05 1.69 4.43 0.0001
5025.80 42.97 0.05 2.00 6.43 0.0001
5025.85 48.79 0.05 2.29 8.73 0.0002
5025.90 54.70 0.05 2.59 11.31 0.0003
5025.95 60.69 0.05 2.88 14.20 0.0003
5026.00 66.75 0.05 3.18 17.38 0.0004
5026.05 72.78 0.05 3.49 20.87 0.0005
5026.10 78.80 0.05 3.79 24.66 0.0006
5026.15 84.81 0.05 4.09 28.75 0.0007
5026.20 90.81 0.05 4.39 33.13 0.0008
5026.25 96.79 0.05 4.69 37.82 0.0009
5026.30 102.76 0.05 4.99 42.81 0.0010
5026.35 108.73 0.05 5.29 48.10 0.0011
5026.40 114.68 0.05 5.58 53.68 0.0012
5026.45 120.74 0.05 5.88 59.57 0.0014
5026.50 126.93 0.05 6.19 65.76 0.0015
5026.55 133.80 0.05 6.52 72.28 0.0017
5026.60 143.11 0.05 6.92 79.20 0.0018
5026.65 151.24 0.05 7.36 86.56 0.0020 WQCV
5026.70 161.54 0.05 7.82 94.37 0.0022
5026.75 170.58 0.05 8.30 102.68 0.0024
5026.80 178.35 0.05 8.72 111.40 0.0026
5026.85 184.86 0.05 9.08 120.48 0.0028
Elevation Depth Volume
WQCV 5026.61 1.06 0.0019
100-yr Detention 5025.55 0.00 0.0000
Overall Detention 5025.55 0.00 0.0000
Stadium Apartmnets November 28, 2018
1232-001 C. Snowdon
Water Quality Pond C
5025.55 ft
0.0019 ac-ft
0.0000 ac-ft Circular Perforation Sizing
1
0.0000 ac-ft Dia (in.)Total Pond Volum
n
1/4
0.05
Required Area
Per Row 0.003 sq-in
9
Total Outlet
Area 0.45 sq. in.
Water Quality Pond C Volume
Elevation
(ft)
Surface
Area (ft2)
Incremental
Depth (ft)
Incremental
Vol. (ft3)
Total Vol.
(ft3)
Total Vol.
(ac-ft)
Calc.
Depths
()
3
**2121AAAADV++=
APPENDIX D
RECORD DRAWINGS
APPENDIX E
STATE PORTAL DOCUMENTS
FINAL DRAINAGE REPORT
Stadium Apartments
Fort Collins, Colorado
January 18, 2017
Prepared for:
Student Housing CSU LLC
2607 Monroe Street
Madison, WI 53711
Prepared by:
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
Phone: 970.221.4158 Fax: 970.221.4159
www.northernengineering.com
Project Number: 1232-001
P This Drainage Report is consciously provided as a PDF.
Please consider the environment before printing this document in its entirety.
When a hard copy is absolutely necessary, we recommend double-sided printing.
January 18, 2017
City of Fort Collins
Stormwater Utility
700 Wood Street
Fort Collins, Colorado 80521
RE: Final Drainage Report for
Stadium Apartments
Dear Staff:
Northern Engineering is pleased to submit this Final Drainage and Erosion Control Report for your
review. This report accompanies the Final Plan submittal for the proposed Stadium Apartments.
Comments from the Staff Review Letter dated December 5, 2016 have been addressed. Written
responses thereto can be found in the comprehensive response to comments letter on file with
Current Planning.
This report has been prepared in accordance to Fort Collins Stormwater Criteria Manual (FCSCM),
and serves to document the stormwater impacts associated with the proposed Stadium Apartments
project. We understand that review by the City is to assure general compliance with standardized
criteria contained in the FCSCM.
If you should have any questions as you review this report, please feel free to contact us.
Sincerely,
NORTHERN ENGINEERING SERVICES, INC.
Nicholas W. Haws, PE Cody Snowdon
Vice President Project Engineer
01.18.17
301 N. Howes Street, Suite 100, Fort Collins, CO 80521 970.221.4158 www.northernengineering.com
Stormwater Facility Name:
Facility Location & Jurisdiction:
User (Input) Watershed Characteristics User Defined User Defined User Defined User Defined
Watershed Slope =0.010 ft/ft Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs]
Watershed Length-to-Width Ratio =1.00 L:W 0.00 3,781 0.00 0.12
Watershed Area =1.61 acres 0.50 3,781 0.50 0.12
Watershed Imperviousness =82.0%percent 1.00 4,492 1.00 0.12
Percentage Hydrologic Soil Group A =0.0%percent 1.50 4,492 1.50 0.12
Percentage Hydrologic Soil Group B =100.0%percent 2.00 4,492 2.00 0.12
Percentage Hydrologic Soil Groups C/D =0.0%percent 2.50 4,492 2.50 0.12
3.00 4,492 3.00 0.12
3.50 4,492 3.50 0.12
4.00 4,492 4.00 3.24
4.50 711 4.50 3.24
User Input: Detention Basin Characteristics
WQCV Design Drain Time =12.00 hours
After completing and printing this worksheet to a pdf, go to:
https://maperture.digitaldataservices.com/gvh/?viewer=cswdif,
create a new stormwater facility, and
attach the pdf of this worksheet to that record.
Routed Hydrograph Results
Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 25 Year 50 Year 100 Year
Two-Hour Rainfall Depth =0.53 0.98 1.36 1.71 2.31 2.91 3.67 in
Calculated Runoff Volume =0.036 0.105 0.154 0.200 0.283 0.366 0.474 acre-ft
OPTIONAL Override Runoff Volume =acre-ft
Inflow Hydrograph Volume =0.036 0.105 0.153 0.200 0.282 0.366 0.473 acre-ft
Time to Drain 97% of Inflow Volume =4 10 15 20 28 36 36 hours
Time to Drain 99% of Inflow Volume =4 11 15 20 28 37 37 hours
Maximum Ponding Depth =0.27 0.97 1.43 1.88 2.68 3.49 3.83 ft
Maximum Ponded Area =0.087 0.102 0.103 0.103 0.103 0.103 0.103 acres
Maximum Volume Stored =0.023 0.088 0.135 0.181 0.264 0.347 0.383 acre-ft
Workbook Protected Worksheet Protected
Stormwater Detention and Infiltration Design Data Sheet
Stadium Apartments Pond B
Fort Collins, Colorado
SDI_Design_Data_FC_Rainfall - Pond B.xlsm, Design Data 2/1/2019, 2:40 PM
Doing_Clear_Formatting =Yes
CountA=1
0 1 2 3
#N/A
#N/A
0 1 2 3
#N/A
#N/A
Check Data Set 1 Check Data Set 1
Area
Discharge
Stormwater Detention and Infiltration Design Data Sheet
0
2
4
6
8
10
12
14
0.1 1 10
FL
O
W
[
c
f
s
]
TIME [hr]
100YR IN
100YR OUT
50YR IN
50YR OUT
25YR IN
25YR OUT
10YR IN
10YR OUT
5YR IN
5YR OUT
2YR IN
2YR OUT
WQCV IN
WQCV OUT
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0.1 1 10 100
PO
N
D
I
N
G
D
E
P
T
H
[
f
t
]
DRAIN TIME [hr]
100YR
50YR
25YR
10YR
5YR
2YR
WQCV
SDI_Design_Data_FC_Rainfall - Pond B.xlsm, Design Data 2/1/2019, 2:40 PM
Stormwater Facility Name:
Facility Location & Jurisdiction:
User (Input) Watershed Characteristics User Defined User Defined User Defined User Defined
Watershed Slope =0.020 ft/ft Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs]
Watershed Length-to-Width Ratio =1.30 L:W 0.00 357.18 0.00 0.11
Watershed Area =0.12 acres 0.40 357.18 0.40 0.11
Watershed Imperviousness =94.0%percent 0.80 357.18 0.80 0.11
Percentage Hydrologic Soil Group A =0.0%percent 1.20 357.18 1.20 0.11
Percentage Hydrologic Soil Group B =100.0%percent 1.60 357.18 1.60 0.11
Percentage Hydrologic Soil Groups C/D =0.0%percent 2.00 190.09 2.00 0.11
2.40 190.09 2.40 0.60
2.50 190.09 2.50 0.60
User Input: Detention Basin Characteristics
WQCV Design Drain Time =12.00 hours
After completing and printing this worksheet to a pdf, go to:
https://maperture.digitaldataservices.com/gvh/?viewer=cswdif,
create a new stormwater facility, and
attach the pdf of this worksheet to that record.
Routed Hydrograph Results
Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 25 Year 50 Year 100 Year
Two-Hour Rainfall Depth =0.53 0.98 1.36 1.71 2.31 2.91 3.67 in
Calculated Runoff Volume =0.003 0.009 0.013 0.016 0.023 0.029 0.037 acre-ft
OPTIONAL Override Runoff Volume =acre-ft
Inflow Hydrograph Volume =0.003 0.009 0.013 0.016 0.022 0.029 0.037 acre-ft
Time to Drain 97% of Inflow Volume =0 1 2 2 3 3 3 hours
Time to Drain 99% of Inflow Volume =0 1 2 2 3 3 3 hours
Maximum Ponding Depth =0.00 0.24 0.55 0.93 1.52 2.12 2.35 ft
Maximum Ponded Area =0.008 0.008 0.008 0.008 0.008 0.004 0.004 acres
Maximum Volume Stored =0.000 0.002 0.005 0.008 0.012 0.016 0.017 acre-ft
Stormwater Detention and Infiltration Design Data Sheet
Stadium Apartments Pond D
Fort Collins, Colorado
Workbook Protected Worksheet Protected
SDI_Design_Data_FC_Rainfall - Pond D.xlsm, Design Data 2/1/2019, 2:39 PM
Doing_Clear_Formatting =Yes
CountA=1
0 1 2 3
#N/A
#N/A
0 1 2 3
#N/A
#N/A
Check Data Set 1 Check Data Set 1
Stormwater Detention and Infiltration Design Data Sheet
Area
Discharge
0
0.2
0.4
0.6
0.8
1
1.2
0.1 1 10
FL
O
W
[
c
f
s
]
TIME [hr]
100YR IN
100YR OUT
50YR IN
50YR OUT
25YR IN
25YR OUT
10YR IN
10YR OUT
5YR IN
5YR OUT
2YR IN
2YR OUT
WQCV IN
WQCV OUT
0
0.5
1
1.5
2
2.5
0.1 1 10 100
PO
N
D
I
N
G
D
E
P
T
H
[
f
t
]
DRAIN TIME [hr]
100YR
50YR
25YR
10YR
5YR
2YR
WQCV
SDI_Design_Data_FC_Rainfall - Pond D.xlsm, Design Data 2/1/2019, 2:39 PM
S
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXX
OH
E
G
G
T
T 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W
WV
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
X
X
X
X
HYD
12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS
S
PROPOSED 8'
ATTACHED SIDEWALK
PR
O
P
E
R
T
Y
L
I
N
E
LOT 18,
COLLEGE
HEIGHTS
LOT 17,
COLLEGE
HEIGHTS
LOT 16,
COLLEGE
HEIGHTS
LOT 11,
COLLEGE
HEIGHTS
LOT 19,
COLLEGE
HEIGHTS
LOT 20,
COLLEGE
HEIGHTS
LOT 7,
BLOCK 2,
COLLEGE
HEIGHTS
9' UTILITY EASEMENT
20' EMERGENCY
ACCESS, ACCESS,
DRAINAGE &
UTILITY ESMT.
26' EMERGENCY
ACCESS, ACCESS,
DRAINAGE &
UTILITY ESMT.
DRAINAGE
EASEMENT
DRAINAGE
EASEMENT
7' DRAINAGE
EASEMENT
10' DRAINAGE
EASEMENT
14'
DRAINAGE
EASEMENT
EX
I
S
T
I
N
G
60
'
R
O
W
26' EMERGENCY
ACCESS, ACCESS,
DRAINAGE &
UTILITY ESMT.
5' DRAINAGE
EASEMENT
28' EMERGENCY
ACCESS, ACCESS,
DRAINAGE &
UTILITY ESMT.
7' DRAINAGE EASEMENT
CONNECT TO EXISTING
WATER MAIN
12"x4" WET TAP
w/ 1 - 4" GV (S)
& 4"x3" REDUCER
EXISTING BURIED ELECTRICEXISTING BURIED
TELEPHONE LINE
EXISTING BURIED
GAS SERVICE
EXISTING 12" WATERLINE
(FORT COLLINS UTILITIES)
EXISTING
LOT LINE (TYP.)
3" DOMESTIC
WATER METER
VAULT WITH
CURB STOP
(TOP OF BOX
EL. = 5027.25)
APPROXIMATE
LOCATION EXISTING
FIRE HYDRANT
CONNECT TO EXISTING WATER MAIN
12"x6" WET CONNECTION w/ TB
& 1 - 6" GV (S)
EXISTING
OVERHEAD
ELECTRICAL
UNDERGROUND
DETENTION AREA
(SC-160 CELLS)
UNDERGROUND
DETENTION AREA
(SC-310 CELLS)
ROOF LEADER
UNDERGROUND
DETENTION AREA
(SC-740 CELLS)
FIRE SERVICE
DOMESTIC WATER
SERVICE
SANITARY
SEWER SERVICE
INV OUT: 5015.81
PROPOSED
ELECTRIC METERS
PROPOSED
GAS METER
CONNECT TO
EXISTING GAS SERVICE
PROPOSED
ELECTRIC
SERVICES
PROPOSED
ELECTRIC VAULT
PROPOSED ELECTRIC
TRANSFORMERS
APPROXIMATE ASPHALT
PATCHING (SEE NOTE 7)
UNDERGROUND
DETENTION AREA
(SC-740 CELLS)
6" PERFORATED
UNDERDRAIN
STORM DRAIN LINE A
SEE SHEET C2.01
STORM DRAIN LINE B
SEE SHEET C2.02
STORM DRAIN LINE C
SEE SHEET C2.02
3' SIDEWALK CHASE
W. LAKE STREET
POND D
SEE SUBGRADE PLAN
SHEET C3.01
POND B
SEE SUBGRADE PLAN
SHEET C3.01 ROOF LEADER
ROOF LEADER
POND B
SEE SUBGRADE PLAN
SHEET C3.02
6" PERFORATED
UNDERDRAIN
RAIN
GARDEN
A
WATER QUALITY
POND C
2' CONCRETE PAN
6" PERFORATED
UNDERDRAIN
STRM TEE A1
INV. IN=5025.01 (S)
INV. IN=5024.98 (W)
INV. OUT=5025.01 (N)
4.99 LF
6" PVC
@ 0.50%
MONITORING WELL A1-1
INV. IN=5025.00 (S)
INV. OUT=5025.00 (E)
67
.
8
3
L
F
6
"
P
E
R
F
.
P
V
C
@
0
.
5
0
%
MONITORING WELL A1-2
INV. OUT=5025.34 (N)
DRAINAGE EASEMENT
EMERGENCY ACCESS, ACCESS,
DRAINAGE & UTILITY ESMT.
UPSIZE DOMESTIC WATER SERVICE
5' AFTER METER
SANITARY
SEWER SERVICE
INV OUT: 5016.38
2' CONCRETE CHASE
STRM JUNCTION A11-1
INV. IN=5027.91 (E)
INV. OUT=5027.91 (SW)
EX SSMH 1
INV IN: 5014.83 (W)
INV OUT: 5014.82 (E)
SERVICE INV: 5015.16 (S)
CLEANOUT
INV. 5015.55
1
APPROXIMATE LOCATION
EXISTING 12" CLAY SANITARY SEWER
(CITY OF FORT COLLINS)
EX SSMH 2
RIM: 5026.54
INV OUT: 5015.13
INV IN: 5015.18
SERVICE IN: 5015.51
CONNECT TO EXISTING 6" CLAY
SANITARY SEWER SERVICE
INV OUT: 5022.47
SANITARY LINE A
SEE SHEET C8.00
W
S
S
CC CC
D
C.O.
C.O.
C.O.D D
C.O.
C.O.
H2O
C.O.C.O.
C.O.
C.O.
D
C.O.
D
D
D C.O.
C.O.
W
S
S
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST ST ST ST
ST ST ST ST
ST ST ST ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST ST ST ST ST
ST
ST
ST
DD
DD
D
S
F
E
E
E
E
E
E
E
E
EV
G
UD
UD
UD
X
X
X
X
X
X
X
X
FDCW
SSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS SS SS
C.O.
C.O.
C.O.
W W W2' CONCRETE
SIDEWALK CHASE
01.18.17
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 26
C2.00
UT
I
L
I
T
Y
P
L
A
N
GRAPHIC SCALE:
LEGEND:
S EXISTING SANITARY MH
G EXISTING GAS METER
CS EXISTING H2O CURB STOP
CONTROL
IRR EXISTING IRR. CONTROL VAULT
ELEC EXISTING ELECTRIC MH
WSO EXISTING H2O SPIGOT
E EXISTING ELECTRIC METER
EXISTING IRR BACKFLOW PREVENT
EXISTING POWER POLE
VAULT
ELEC EXISTING ELECTRIC VAULT
T EXISTING TELEPHONE PEDESTAL
W PROPOSED H2O METER
EXISTING LIGHT POLE
HYD EXISTING FIRE HYDRANT
TRAFFIC
VAULT EXISTING TRAFFIC VAULT
FO EXISTING BURIED FIBER-OPTICS
E EXISTING BURIED ELECTRIC
G EXISTING BURIED GAS
W EXISTING WATER LINE
T EXISTING BURIED TELEPHONE
SS EXISTING SANITARY SEWER LINE
ST EXISTING STORM SEWER LINE
OHE EXISTING OVERHEAD ELECTRIC
PROPOSED WATER SERVICE LINE
PROPOSED SANITARY SERVICE LINE
PROPOSED STORM SEWER LINE W/ INLET
GENERAL NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER AND SANITARY SEWER CONSTRUCTION SHALL BE PER THE CITY OF
FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION.
3.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
4.ALL WATER FITTINGS, VALVES, AND OTHER UTILITY APPURTENANCES ARE ONLY
GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5.ALL EXISTING SANITARY SEWER SERVICES ARE APPROXIMATE AND SHALL BE
FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO BE
UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT
COLLINS UTILITIES (970-221-6700).
6.PRIOR TO ORDERING MATERIAL AND MOBILIZING, CONTRACTOR SHALL FIELD
LOCATE AND VERIFY ELEVATIONS OF ALL CONCRETE AND ASPHALT TIE-INS,
EXISTING SEWER MAINS, WATER MAINS, AND ALL OTHER UTILITIES AT THE
POINTS OF CONNECTION SHOWN ON THE PLANS. SPECIAL ATTENTION SHALL BE
PAID TO ALL PROPOSED UTILITY CROSSINGS. IT IS RECOMMENDED THAT THE
CONTRACTOR POTHOLE SAID CROSSINGS PRIOR TO ORDERING MATERIAL.
REFER TO GENERAL NOTE #9 ON SHEET C0.01 IF A CONFLICT ARISES AND/OR A
DESIGN MODIFICATION IS DESIRED.
7.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL
REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
8.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED PLUMBING
DRAWINGS FOR ALL SERVICE SIZES AND LOCATIONS. NOTIFY OWNER,
ARCHITECT, AND ENGINEER(S) OF ANY DISCREPANCIES PRIOR TO
MOBILIZATION.
9.CONTRACTOR TO COORDINATE ALL ROOF LEADERS WITH THE ARCHITECTURAL
AND PLUMBING PLANS PRIOR TO CONSTRUCTION OR ORDERING OF MATERIAL.
IF A CONFLICT EXISTS, CONTRACTOR TO CONTACT THE ENGINEER.
10.POUR NEW SANITARY MANHOLE BASE & CUT TOP OF EXISTING PIPE. NEW
MANHOLE SECTION AND CONE PER CITY DETAIL.
11.SERVICES CONNECTING DIRECTLY INTO THE SANITARY SEWER MANHOLE SHALL
BE WITHIN 2 FEET OF THE MANHOLE INVERT, OR AN OUTSIDE DROP SHALL BE
CONSTRUCTED
EXISTING CLEANOUTC.O.
PROPOSED DOWNSPOUT
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROJECT BOUNDARY
FDC
EXISTING LOTLINE
PROPOSED EASEMENT LINE
PROPOSED CURB & GUTTER
PROPOSED FIRE DEPARTMENT CONNECTION
PROPOSED FIRE SERVICE LINE
IRR PROPOSED IRRIGATION METER
----
1
SA
N
I
T
A
R
Y
S
E
W
E
R
S
E
R
V
I
C
E
R
E
V
I
S
I
O
N
CN
S
02
.
2
0
.
1
7
2
PR
O
P
O
S
E
D
S
E
W
E
R
M
A
I
N
CN
S
05
.
1
1
.
1
7
3
RE
V
I
S
E
D
S
T
O
R
M
C
H
A
M
B
E
R
S
CN
S
09
.
1
3
.
1
7
4
RE
V
I
S
E
D
S
T
O
R
M
L
I
N
E
B
CN
S
09
.
1
3
.
1
7
THESE
R
E
C
O
R
D
D
R
A
W
I
N
G
S
,
P
R
O
D
U
C
E
D
B
Y
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
SERVIC
E
S
,
I
N
C
.
,
A
R
E
B
A
S
E
D
I
N
W
H
O
L
E
,
O
R
I
N
P
A
R
T
,
U
P
O
N
I
N
F
O
R
M
A
T
I
O
N
PROVID
E
D
B
Y
O
T
H
E
R
S
.
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
S
E
R
V
I
C
E
S
,
I
N
C
.
A
S
S
U
M
E
S
NO LIAB
I
L
I
T
Y
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
T
H
I
S
I
N
F
O
R
M
A
T
I
O
N
.
RECOR
D
D
R
A
W
I
N
G
3
5
RE
C
O
R
D
D
R
A
W
I
N
G
S
MC
R
10
.
0
4
.
1
7
C:\Users\cody\Documents\Stamp.jpg
10.12.17C:\Users\cody\Documents\Transparent Signature 2.png
RECORD INFO. ONLY(SEE RECORDDRAWING NOTE)
T
G
E
E
12
"
W
12
"
W
12
"
W
12
"
W
V.
P
.
V.
P
.
WV
/ / / / / / / // / / / / / / /X / / / / / / / // / / / / / / // / / / / / / // / / / / / / /X X X X
HYD
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
HEADWALL A
(SEE DETAIL)
STA 10+17.92
N: 124330.60
E: 190742.42
DRAIN BASIN A2
STA 12+52.00
N: 124097.01
E: 190745.64
10
0
.
3
1
L
F
1
2
"
P
V
C
@
0
.
2
0
%
DRAIN BASIN A3
STA 13+52.31
N: 124097.33
E: 190645.33
13.38 LF 12" PVC @ 0.20%
27.09 LF 12" PVC @ 0.20%
DRAIN BASIN A4
W/ ORIFICE PLATE
STA 13+65.69
N: 124087.90
E: 190635.84
LOT 18,
COLLEGE
HEIGHTS
W.
L
A
K
E
S
T
R
E
E
T
LOT 19,
COLLEGE
HEIGHTS
LOT 20,
COLLEGE
HEIGHTS
LOT 7,
BLOCK 2,
COLLEGE
HEIGHTS
RAIN
GARDEN A
13.64 LF 12" PVC @ 0.20%
DRAIN BASIN A5
STA 13+79.32
N: 124078.29
E: 190626.16
OUTLET STRUCTURE A6
STA 13+83.19
N: 124078.32
E: 190622.30
3.87 LF 12" PVC @ 0.20%
148.05 LF 12" PVC @ 0.20%
STRM TEE A1
STA 11+03.95
N: 124245.05
E: 190746.94
4.99 LF 6" PERFORATED PVC @ 0.50%
MONITORING WELL A1-1
INV. IN=5025.00 (S)
INV. OUT=5025.00 (E)
FG=5027.50
67.83 LF 6" PERFORATED PVC @ 0.50%
MONITORING WELL A1-2
INV. OUT=5025.34 (N)
FG=5027.00
58.94 LF
12" PVC
@ 0.20%
STRM A BEND
INV. IN=5024.89 (S)
INV. OUT=5024.89 (N)
FG=5026.60
W
D
C.
O
.
C.
O
.
H2
OW
ST
ST
ST
STSTSTSTST
ST
ST
D
F
X X X X
FD
C
W
C.
O
.
C.
O
.
5010
5015
5020
5025
5030
5035
5040
5045
5010
5015
5020
5025
5030
5035
5040
5045
9+50 10+00 11+00 12+00 13+00 14+00 15+00
HE
A
D
W
A
L
L
A
ST
A
1
0
+
1
7
.
9
2
IN
V
.
5
0
2
4
.
8
4
(
S
)
27.09 LF 12" PVC @ 0.20%
100.31 LF 12" PVC @ 0.20%
DR
A
I
N
B
A
S
I
N
A
3
ST
A
1
3
+
5
2
.
3
1
RI
M
5
0
3
0
.
8
±
IN
V
.
I
N
5
0
2
5
.
5
1
(
S
W
)
IN
V
.
O
U
T
5
0
2
5
.
5
1
(
E
)
13.38 LF
12" PVC
@ 0.20%
DR
A
I
N
B
A
S
I
N
A
4
ST
A
1
3
+
6
5
.
6
9
RI
M
5
0
3
1
.
5
±
IN
V
.
I
N
5
0
2
5
.
5
3
(
N
W
)
IN
V
.
I
N
5
0
2
5
.
5
3
(
S
W
)
IN
V
.
O
U
T
5
0
2
5
.
5
3
(
N
E
)
EXISTING
GROUND
PROPOSED
GROUND
DR
A
I
N
B
A
S
I
N
A
2
ST
A
1
2
+
5
2
.
0
0
RI
M
5
0
2
8
.
6
±
IN
V
.
I
N
5
0
2
5
.
3
1
(
W
)
IN
V
.
O
U
T
5
0
2
5
.
3
1
(
N
)
DR
A
I
N
B
A
S
I
N
A
5
ST
A
1
3
+
7
9
.
3
2
RI
M
5
0
3
1
.
9
±
IN
V
.
I
N
5
0
2
5
.
5
6
(
W
)
IN
V
.
O
U
T
5
0
2
5
.
5
6
(
N
E
)
OU
T
L
E
T
S
T
R
U
C
T
U
R
E
A
6
ST
A
1
3
+
8
3
.
1
9
RI
M
5
0
3
1
.
8
±
IN
V
.
I
N
5
0
2
6
.
2
4
(
W
)
IN
V
.
I
N
5
0
2
6
.
2
4
(
S
)
IN
V
.
I
N
5
0
2
6
.
2
4
(
N
)
IN
V
.
O
U
T
5
0
2
5
.
5
7
(
E
)
13.64 LF
12" PVC
@ 0.20%
3.87 LF
12" PVC
@ 0.20%
ST
R
M
T
E
E
A
1
ST
A
1
1
+
0
3
.
9
5
RI
M
5
0
2
7
.
5
±
IN
V
.
I
N
5
0
2
5
.
0
1
(
S
)
IN
V
.
I
N
5
0
2
4
.
9
8
(
W
)
IN
V
.
O
U
T
5
0
2
5
.
0
1
(
N
)
148.05 LF 12" PVC @ 0.20%
100-YEAR HGL
CONCRETE
HEADWALL
FLOWLINE
CONCRETE PAN
ST
R
M
A
B
E
N
D
ST
A
1
0
+
4
5
.
0
1
IN
V
.
5
0
2
4
.
8
9
(
S
)
IN
V
.
5
0
2
4
.
8
9
(
N
)
58.94 LF 12" PVC @ 0.20%
01.18.17
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 26
C2.01
PL
A
N
&
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
A
STORM DRAIN LINE A
PROFILE SCALE:
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
NORTH
LEGEND:
S EXISTING SANITARY MH
W PROPOSED H2O METER
HYD EXISTING FIRE HYDRANT
E EXISTING BURIED ELECTRIC
W EXISTING WATER LINE
T EXISTING BURIED TELEPHONE
SS EXISTING SANITARY SEWER LINE
ST EXISTING STORM SEWER LINE
OHE EXISTING OVERHEAD ELECTRIC
PROPOSED WATER SERVICE LINE
PROPOSED SANITARY SERVICE LINE
PROPOSED STORM SEWER LINE W/ INLET
GENERAL NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET
BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH
OF PLACED END SECTIONS.
3.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED PLUMBING
DRAWINGS FOR ALL ROOF DRAINS AND COURTYARD DRAIN SIZES AND
LOCATIONS. NOTIFY OWNER, ARCHITECT, AND ENGINEER(S) OF ANY
DISCREPANCIES PRIOR TO MOBILIZATION.
4.ALL STORM SEWER TO BE INSTALLED WITH WATER TIGHT JOINTS AT EACH
CONNECTION.
PROPOSED DOWNSPOUT
PROJECT BOUNDARY
FDC
EXISTING LOTLINE
PROPOSED EASEMENT LINE
PROPOSED CURB & GUTTER
PROPOSED FIRE DEPARTMENT CONNECTION
PROPOSED FIRE SERVICE LINE
IRR PROPOSED IRRIGATION METER
EXISTING POWER POLE
T EXISTING TELEPHONE PEDESTAL
KEYMAP
STORM A
PROPOSED PERF. UNDERDRAIN
SEE SUBGRADE PLAN SHEET C3.02
----
SIDEWALK
CHASE
THESE
R
E
C
O
R
D
D
R
A
W
I
N
G
S
,
P
R
O
D
U
C
E
D
B
Y
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
SERVIC
E
S
,
I
N
C
.
,
A
R
E
B
A
S
E
D
I
N
W
H
O
L
E
,
O
R
I
N
P
A
R
T
,
U
P
O
N
I
N
F
O
R
M
A
T
I
O
N
PROVID
E
D
B
Y
O
T
H
E
R
S
.
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
S
E
R
V
I
C
E
S
,
I
N
C
.
A
S
S
U
M
E
S
NO LIAB
I
L
I
T
Y
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
T
H
I
S
I
N
F
O
R
M
A
T
I
O
N
.
RECOR
D
D
R
A
W
I
N
G
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
LOT 7,
BLOCK 2,
COLLEGE
HEIGHTS
7.34 LF
10" PVC
@ 0.20%
E: 190632.61
RAIN
GARDEN A
ROOF DRAIN B3
FROM INTERIOR COURTYARD
STA 10+27.95
N: 124206.02
E: 190707.20
MONITORING WELL B1
STA 9+94.34
N: 124205.82
E: 190740.81C.O.
C.O.
ST ST
ST
ST
ST
ST
ST
X
X
X
X
5010
5015
5020
5025
5030
5035
5040
5045
5010
5015
5020
5025
5030
5035
5040
5045
8+509+0010+0011+00
RO
O
F
D
R
A
I
N
B
3
ST
A
1
0
+
2
7
.
9
5
IN
V
.
5
0
2
6
.
5
0
(
E
)
7.34 LF
10" PVC
@ 0.20%
MO
N
I
T
O
R
I
N
G
W
E
L
L
B
1
ST
A
9
+
9
4
.
3
4
IN
V
.
5
0
2
5
.
4
9
(
W
)
EXISTING
GROUND
PROPOSED
GROUND
100-YEAR HGL
S
T
X
GEEE E
12" W 12" W 12" W 12" W 12" W 12" W 12" W
12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SSS
W. LAKE STREET
HEADWALL C
(SEE DETAIL)
STA 10+10.35
N: 124339.42
E: 190632.61
DRAIN BASIN C1
STA 10+24.12
N: 124325.65
E: 190632.61
DRAIN BASIN C2
STA 11+28.52
N: 124325.65
E: 190528.21
DRAIN BASIN C4
STA 11+90.86
N: 124319.54
E: 190466.18
OUTLET STRUCTURE C5
W/ ORIFACE PLATE
STA 12+48.57
N: 124287.74
E: 190418.01
13.77 LF
(2)-6" PVC
@ 0.20%
104.40 LF
10" PVC
@ 0.20%
54.31 LF
10" PVC
@ 0.20%
57.72 LF
10" PVC
@ 0.20%
8.03 LF
10" PVC
@ 0.20%
DRAIN BASIN C3
STA 11+82.83
N: 124320.32
E: 190474.17
5.99 LF
8" PVC
@ 0.50%
WATER QUALITY C3-1
STA 11+82.95
N: 124326.28
E: 190473.47
W
S
H2O
C.O.C.O.
C.O.
C.O.
D
W
S
ST
ST
ST ST ST
DD
S
F
E
E
E
EV
UD
FDCW
SS
SS
SS
SS
5015
5020
5025
5030
5035
5040
5045
5050
5015
5020
5025
5030
5035
5040
5045
5050
9+5010+0011+0012+0013+0013+50
HE
A
D
W
A
L
L
C
ST
A
1
0
+
1
0
.
3
5
IN
V
.
5
0
2
5
.
1
9
(
S
)
13.77 LF
(2)-6" PVC
@ 0.20%
DR
A
I
N
B
A
S
I
N
C
1
ST
A
1
0
+
2
4
.
1
2
RI
M
5
0
2
8
.
5
±
IN
V
.
I
N
5
0
2
5
.
2
4
(
W
)
IN
V
.
O
U
T
5
0
2
5
.
2
2
(
N
)
104.40 LF
10" PVC
@ 0.20%
DR
A
I
N
B
A
S
I
N
C
2
ST
A
1
1
+
2
8
.
5
2
RI
M
5
0
2
8
.
5
±
IN
V
.
I
N
5
0
2
5
.
4
5
(
W
)
IN
V
.
O
U
T
5
0
2
5
.
4
5
(
E
)
54.31 LF
10" PVC
@ 0.20%
DR
A
I
N
B
A
S
I
N
C
4
ST
A
1
1
+
9
0
.
8
6
RI
M
5
0
2
7
.
9
±
IN
V
.
I
N
5
0
2
5
.
5
7
(
S
W
)
IN
V
.
O
U
T
5
0
2
5
.
5
7
(
E
)
57.72 LF
10" PVC
@ 0.20%
OU
T
L
E
T
S
T
R
U
C
T
U
R
E
C
5
ST
A
1
2
+
4
8
.
5
7
RI
M
5
0
2
9
.
2
±
IN
V
.
I
N
5
0
2
6
.
0
0
(
S
)
8
"
P
V
C
IN
V
.
I
N
5
0
2
6
.
3
4
(
W
)
8
"
P
V
C
IN
V
.
O
U
T
5
0
2
5
.
6
9
(
N
E
)
4
"
P
E
R
F
.
P
V
C
EXISTING
GROUND
PROPOSED
GROUND
DR
A
I
N
B
A
S
I
N
C
3
ST
A
1
1
+
8
2
.
8
3
RI
M
5
0
2
8
.
3
±
IN
V
.
I
N
5
0
2
5
.
5
6
(
W
)
IN
V
.
I
N
5
0
2
5
.
5
7
(
N
)
IN
V
.
O
U
T
5
0
2
5
.
5
6
(
E
)
8.03 LF
10" PVC
@ 0.20%
100-YEAR
HGL
DR
A
I
N
B
A
S
I
N
C
1
ST
A
1
0
+
2
4
.
1
2
RI
M
5
0
2
8
.
5
±
IN
V
.
I
N
5
0
2
5
.
2
4
(
W
)
IN
V
.
O
U
T
5
0
2
5
.
2
2
(
N
)
5010
5015
5020
5025
5030
5035
5040
5045
5010
5015
5020
5025
5030
5035
5040
5045
9+50 10+00 11+00
EXISTING
GROUND
PROPOSED
GROUND
WA
T
E
R
Q
U
A
L
I
T
Y
C
3
-
1
ST
A
1
1
+
8
2
.
9
5
IN
V
.
5
0
2
5
.
6
0
(
S
)
5.99 LF
8" PVC
@ 0.50%
DR
A
I
N
B
A
S
I
N
C
3
ST
A
1
1
+
8
2
.
8
3
RI
M
5
0
2
8
.
3
±
IN
V
.
I
N
5
0
2
5
.
5
6
(
W
)
IN
V
.
I
N
5
0
2
5
.
5
7
(
N
)
IN
V
.
O
U
T
5
0
2
5
.
5
6
(
E
)
100-YEAR HGL
01.18.17
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 26
C2.02
PL
A
N
&
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
L
I
N
E
S
B
,
C
&
C
3
STORM DRAIN LINE B
PROFILE SCALE:
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
NORTH
LEGEND:
S EXISTING SANITARY MH
W PROPOSED H2O METER
HYD EXISTING FIRE HYDRANT
E EXISTING BURIED ELECTRIC
W EXISTING WATER LINE
T EXISTING BURIED TELEPHONE
SS EXISTING SANITARY SEWER LINE
ST EXISTING STORM SEWER LINE
OHE EXISTING OVERHEAD ELECTRIC
PROPOSED WATER SERVICE LINE
PROPOSED SANITARY SERVICE LINE
PROPOSED STORM SEWER LINE W/ INLET
GENERAL NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET
BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH
OF PLACED END SECTIONS.
3.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED PLUMBING
DRAWINGS FOR ALL ROOF DRAINS AND COURTYARD DRAIN SIZES AND
LOCATIONS. NOTIFY OWNER, ARCHITECT, AND ENGINEER(S) OF ANY
DISCREPANCIES PRIOR TO MOBILIZATION.
4.ALL STORM SEWER TO BE INSTALLED WITH WATER TIGHT JOINTS AT EACH
CONNECTION.
PROPOSED DOWNSPOUT
PROJECT BOUNDARY
FDC
EXISTING LOTLINE
PROPOSED EASEMENT LINE
PROPOSED CURB & GUTTER
PROPOSED FIRE DEPARTMENT CONNECTION
PROPOSED FIRE SERVICE LINE
IRR PROPOSED IRRIGATION METER
EXISTING POWER POLE
T EXISTING TELEPHONE PEDESTAL
KEYMAP
STORM
B
PROFILE SCALE:
NORTH
STORM DRAIN LINE C
STORM C
STORM DRAIN LINE A
SEE SHEET C2.01
----
STORM DRAIN LINE C3
PROFILE SCALE:
THESE
R
E
C
O
R
D
D
R
A
W
I
N
G
S
,
P
R
O
D
U
C
E
D
B
Y
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
SERVIC
E
S
,
I
N
C
.
,
A
R
E
B
A
S
E
D
I
N
W
H
O
L
E
,
O
R
I
N
P
A
R
T
,
U
P
O
N
I
N
F
O
R
M
A
T
I
O
N
PROVID
E
D
B
Y
O
T
H
E
R
S
.
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
S
E
R
V
I
C
E
S
,
I
N
C
.
A
S
S
U
M
E
S
NO LIAB
I
L
I
T
Y
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
T
H
I
S
I
N
F
O
R
M
A
T
I
O
N
.
RECOR
D
D
R
A
W
I
N
G
W
S
S
CC CC
D
C.O.
C.O.
C.O.D D
C.O.
C.O.
H2O
C.O.C.O.
C.O.
C.O.
D
C.O.
D
D
D C.O.
C.O.
W
S
S
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST ST ST ST
ST ST ST ST
ST ST ST ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST ST ST ST ST
ST
ST
ST
DD
DD
D
S
F
E
E
E
E
E
E
E
E
EV
G
UD
UD
UD
X
X
X
X
X
X
X
X
FDCW
SSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS SS SS
C.O.
C.O.
C.O.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXX
V.P.V.P.
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
X
X
X
X
X
X X X X X X X X
WSO
W. LAKE STREET
4.
2
%
2.
9
%
2.9%
1.1%3.
3
%
3.
8
%
4.
5
%
4.
5
%
32:1
2.2%
21.4%
21.7%
4:1
11
.
3
%
8:1
1.1
%
6.3%
20.1%
13.1%
11
.
8
%
13
.
4
%
12
.
3
%
15.1%
4:1
4:1
3.0%
3.8
%
2.3%
2.1%
3.7
%
2.0%
3.1
%
5.6
%
6.
0
%
2.0
%
2.
0
%
2.1
%
2.
0
%
2.1
%
2.
0
%
6.
5
%
2.2%
2.2%
2.0%
2.2%
1.7%
PROPOSED 8'
ATTACHED SIDEWALK
5'
S
I
D
E
W
A
L
K
6' CROSSPAN
(EXTEND CONCRETE
TO ROW)
EXISTING 18" OUTFALL
CURB & GUTTER
RAMPS
2' SIDEWALK
CHASE
INLET
W/ SUMP
OUTLET BASIN W/
ORIFICE PLATE
INLET
W/ SUMP
4" PERFORATED
UNDERDRAIN
6" PERFORATED
UNDERDRAIN
AREA INLET
RAMP
OUTLET BASIN
W/ ORIFICE PLATE
2' SIDEWALK
CHASE 3' SIDEWALK
CHASE
2.0' FLUSH
CHEEK WALL (TYP.)
UN
D
E
R
G
R
O
U
N
D
PO
N
D
D
UN
D
E
R
G
R
O
U
N
D
PO
N
D
B
UNDERGROUND
POND B
18" OUTFALL
CURB &GUTTER
18" OUTFALL
CURB & GUTTER
18" CURB &
GUTTER
18" CURB &
GUTTER
18" CURB &
GUTTER
REPLACE EXISTING
CURB & GUTTER
CROSSPAN
STAMPED CONCRETE
EXISTING CONCRETE
WALL & FENCE
EXISTING CONCRETE
WALL & FENCE
EXISTING CONCRETE
WALL & FENCE
EMERGENCY
OVERFLOW
WEIR LOCATION
EMERGENCY
OVERFLOW
WEIR LOCATION
CONCRETE
CHASE
6" PERFORATED
UNDERDRAIN
BIKE RACK STORM DRAIN LINE A
SEE SHEET C2.01
STORM DRAIN LINE B
SEE SHEET C2.02
STORM DRAIN LINE C
SEE SHEET C2.02
26.2
8
26.93
26.94
25
.
9
5
26.1
8
26.91
26.8
9
28.84
28.6
4
28.
8
4
29.16
29.9
8
30.02
30.0
4
30.4
4
30.1630.42
30.42
30.42
30.6
8
31.0
4
32.5032.29
32.25
31
.
8
6
32.0
2
32.2
2
31.97
31.73
31
.
6
0
31
.
7
3
31.9
5
32.43
32.
2
1
32.08
32.
0
8
31.4
1
31.19
31.5
6
30.7
1
30.9
3
30.9
9
30.93
30.7
1
30.9
9
31.21
32.70
31.4
8
30.3
5
30.6
7
30
.
7
4
30.7
1
30.4
3
26
.
5
6 26.2
9
26.21
26.48 26
.
1
0
25.7
2
25.52
25.4
4
FFE=30.00
FFE=29.00
FFE=30.00
FFE=30.00
33.06
32.
9
5
28.09
29.0
0
(30
.
9
2
)
(29
.
3
8
)
(30
.
4
4
)
(27
.
0
1
)
(26
.
9
4
)
(25.2
3
)
(3
1
.
3
1
)
(30
.
9
4
)
(3
1
.
8
5
)
(32
.
3
2
)
(32
.
7
6
)
29.74
30.42
26
.
2
3
26.
5
7
26.40 26.6
3
26
.
6
0
26.
0
0
(3
2
.
6
6
)
(3
2
.
5
3
)
(3
2
.
4
2
)
(32
.
2
0
)
32.0
0
31
.
2
1
31
.
9
7
(29
.
7
9
)
(29
.
7
3
)
(28.43)
(27.3
7
)
32.
2
7
32.30
25.
1
4
24.
6
7
(26
.
6
9
)
(26
.
4
4
)
(26
.
9
8
)
27.71
31.2
8
28.5
0
30.00
30.00
30.00
28.98
30.00
30.00
30.
0
0
25.7
7
35.40
35.40
32.2
8
32.31
(8)- RISERS
(6) RISERS
(5)-RISERS28.29 (5)-RISERS (6)-RISERS
(4)-RISERS
31.71
32.28
33.24 32.99
32.75
29.22
29.1
4
30.76
31.90
31.4
5
31.78
31.54
STAMPED CONCRETE
4.8
%
31.6
0
28.65
28.04
27.
0
1
27
.
0
0
28.50
27.0
0
27.00
27.99
29
.
8
9
(3
0
.
1
6
)
27.
6
9
27.34
9.8%
(3
0
.
7
3
)
(3
1
.
0
5
)
(30
.
8
8
)
30
.
1
8
(30
.
6
7
)
31.16
31.2
431.25
32.
1
4
32.20
31.72
31.68
31.5
1
31.6
9
31.5
4
32.08
31.1
5
31.3
0
31.7
1
FLUSH
CURB
3.5%
24
.
6
0
27.
0
6
26.7
0
26.3
2
26.1
8
26.2
326.21
26.
0
9
26.4
2
26.96
26.90
27.0
5
27.06
29.2
1
24.84
24.82
27.40
27.60
28
.
1
0
27.60
28.10
RAMP
WATER QUALITY
OUTLET STRUCTURE
WATER QUALITY
BASIN WITH WEIR
WATER QUALITY
POND C
WATER QUALITY
BASIN WITH WEIR
WATER QUALITY
BASIN WITH WEIR
WATER QUALITY
BASIN WITH WEIR
LANDSCAPE WALL
TOW ELEVATION =5032.0
(SEE LANDSCAPE PLANS)
6" PERFORATED
UNDERDRAIN
RAIN GARDEN
POND A
(1)-7" RISER
(1)-7" RISER
(1)-7" RISER
(1)-7" RISER
DETAILED GRADING
SEE SHEET C3.03
DETAILED GRADING
SEE SHEET C3.03
DETAILED GRADING
SEE SHEET C3.03
DETAILED GRADING
SEE SHEET C3.03
28.14
29.
3
2
29.44
31
.
9
4
32
.
4
7
32.58
32.79
32
.
7
8
32.
9
0
33.20
31.75
31.4
9
31.5
9
31.5
5
2' CURB CUT 2' CURB CUT
DETAILED GRADING
SEE SHEET C3.03
UPPER COURTYARD
FFE=42.00
STAIR WELL
FFE=35.50
STAIR WELL
FFE=35.50
28.6
5
28.41
35.
5
0
35.
5
0
32.9
8
32.78
32.54
32.7
4
32.92
33.12
29.5
0
29.
5
0
29
.
0
0
28.40
29.0
3
29.3
3
29.3
3
28.08
28.50
27.00
28.0
8
29.0
0
28.90
29.10
29.3
3
29.33
RAMP
2.5' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
1.5' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
1.0' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
2.0' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
2' CONCRETE PAN
4:1
30.60
30.20
1.0' LANDSCAPE WALL
(SEE LANDSCAPE PLANS)
CC CC
H2OW
27.00
01.18.17
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 26
C3.00
GR
A
D
I
N
G
P
L
A
N
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
GRAPHIC SCALE:
LEGEND:
EXISTING DECID. TREE
EXISTING CONIF. TREE
EXISTING LIGHT POLE
EXISTING STUMP
ST EXISTING STORM SEWER LINE
EXISTING CURB/GUTTER FLOWLINE
EXISTING EDGE OF ASPHALT
28
4:1 GROUND SLOPE
PROPOSED PAVEMENT CROSS SLOPE
CONCENTRATED FLOW DIRECTION
PROPOSED SWALE FLOWLINE
PROPOSED INFLOW CURB/GUTTER FLOWLINE
PROPOSED STORM DRAIN WITH INLET
PROPOSED CONTOUR
EXISTING CONTOUR
79.45 PROPOSED FINISHED GROUND ELEVATION
(79.45)
EXISTING GROUND ELEVATION
PROPOSED OUTFALL CURB/GUTTER FLOWLINE
BENCHMARK/BASIS OF BEARING
NOTES:
1.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR
PROTECTION FROM THE 100-YEAR STORM.
2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE
WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK.
BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
3.EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL
FOLLOW CITY REGULATIONS.
4.REFER TO SITE PLAN, LANDSCAPE PLAN, AND PLAT FOR ADDITIONAL INFORMATION.
5.THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL
CURBS AND GUTTERS AT THE POINTS OF CONNECTION SHOWN ON THE PLANS PRIOR TO
INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN
MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO
MODIFY THE DESIGN.
6.ADD 5000-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS, WHERE
TRUNCATED.
7.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED ARCHITECTURAL AND
LANDSCAPE ARCHITECTURE DRAWINGS FOR ALL STEPS, RAMPS, CHEEK WALLS, AND
HANDRAILS.
8.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED STRUCTURAL DRAWINGS
FOR ELEVATIONS AND GRADE CONDITIONS ALONG BUILDING PERIMETER. NOTIFY OWNER,
ARCHITECT, AND ENGINEER(S) OF ANY DISCREPANCIES PRIOR TO MOBILIZATION.
2.0%
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
NORTH
PROJECT DATUM: NAVD 88
BENCHMARK #1:
CITY OF FORT COLLINS BENCHMARK 29-92: APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT
RD. AND SHIELDS ST., ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK #2:
CITY OF FORT COLLINS BENCHMARK 28-92: SOUTHWEST CORNER OF WEST PROSPECT RD. AND
CENTER AVE., ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING
DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17.
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHWEST QUARTER OF SECTION 14,
TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M. AS BEARING SOUTH 89°22'14" EAST
----
THESE
R
E
C
O
R
D
D
R
A
W
I
N
G
S
,
P
R
O
D
U
C
E
D
B
Y
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
SERVIC
E
S
,
I
N
C
.
,
A
R
E
B
A
S
E
D
I
N
W
H
O
L
E
,
O
R
I
N
P
A
R
T
,
U
P
O
N
I
N
F
O
R
M
A
T
I
O
N
PROVID
E
D
B
Y
O
T
H
E
R
S
.
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
S
E
R
V
I
C
E
S
,
I
N
C
.
A
S
S
U
M
E
S
NO LIAB
I
L
I
T
Y
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
T
H
I
S
I
N
F
O
R
M
A
T
I
O
N
.
RECOR
D
D
R
A
W
I
N
G
PROPOSED 8' ATTACHED SIDEWALK
2' SIDEWALK
CHASE
2' SIDEWALK
CHASE
REPLACE EXISTING
CURB & GUTTER W/
18" VERTICAL CURB
AND GUTTER25
.
9
5
26
.
8
9
26
.
5
8
26.2
9
26.21
26.49 26
.
1
0
25.72 25.5
2
25.
4
5
26.1
0
26.2
3
26.
7
6
26
.
6
6
26.
0
0
25
.
1
4
28
.
7
1
28
.
7
1
25.5
8
25.60
25.4
7
25.5
0
28.90
25.9
1
25.8
0
28.55
26.1326.16
28.
5
1
26.36 26.34
27.4
1
27.1
9
28.7
1
26.62
26.
6
5
25.84
25.9
3
27.
9
3
28.9
0 26.06
26.5
3
28.9
1
27.1
9
27.6
9
26.1
9
2.
0
%
2.
0
%
2.
0
%
2.
0
%
2.2
%
5.2
%
2.
0
%
2.
0
%
25.88
28.68
28.66
28.8
7
26.41 26.29
28.7
125.9
4
25.99
26.00
27.02
25
.
9
2
26
.
0
1
26.02
28.
3
0
28
.
4
3
27.1
0
27.0
6
26.85
26.
7
0
26
.
3
2
26
.
1
8
28.5
6
28.
2
5
26.
1
2
27.10
WATER QUALITY
OUTLET STRUCTURE
27.61
27.94
27
.
9
9
27.09
26.04
28.25
27.2
0
28.2
5
27.95
27.95
27
.
9
4
27
.
1
5
26.89
28.53
28
.
5
6
26.0
6
26.06
28
.
5
6
26
.
9
4
27.39
26.95
26.79
28.26
29.7
5
29.3
3
29.67
29.4
4
29.60
29.
0
2
29.02 29.0
2
29.60
29.02
29.
3
329.6
7
29.7
5
(1)-RISER
(4)-RISERS
FFE=30.00
FFE=30.00
FFE=29.00
FFE=30.00
2.
0
%
29.23
29.33
29.25
28.95
29.3
3
29.71
29.75
29.75
29.67
29
.
3
3
29.6
0
29
.
0
2
29.02
29.0
229.02
29.60
28.66
28.3
3
28.8
0
28.33
28
.
8
0
28.92
29.00
29.00
28.11
28
.
7
1
28.71
28.
7
1
28
.
2
6
28.05
28.7
1
28.33
28.7
8
29.00
28.7
8
28.3
3
28.98
29.00
29.00
28
.
9
8
29.02
29.60
29.02 29.02
29
.
6
7
29.
6
7
29.32
29.7
5
29.7
5
29.71
29.71 29.32
29
.
0
2
29.60
28.76
25.7425.76
26
.
0
3
26.0826.2426.2626.5
0
26
.
5
3
28.92
29.23
29.3329.33
29.0
3
29.33
29.67
29.6
0
29.0
2
29.02 29.02 29
.
0
2
29.
6
0
29.67
29.33
29.33
29
.
7
5
FFE=30.00
2.0' LANDSCAPE
WALL (BY OTHERS)
1.0' LANDSCAPE
WALL (BY OTHERS)
1.5' LANDSCAPE
WALL (BY OTHERS)
2.0' - FLUSH CHEEK
WALL (BY OTHERS)
2.5' LANDSCAPE
WALL (BY OTHERS)
(5)-RISERS
(5)-RISERS
(6)-RISERS
(6)-RISERS
PROPOSED 8' ATTACHED SIDEWALK
2.
0
%
(1) RISER
(1)-RISER
HARDSCAPE AREAHARDSCAPE AREA
25.8
1
25
.
1
8
25
.
1
9
25.94
29
.
6
7
29.
7
5
(1)-RISER
RAMP
H2OW
WATER QUALITY POND C
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
X
X
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
X
X
X
X
3' SIDEWALK
CHASE
EXISTING CONCRETE
WALL & FENCE
CONCRETE
CHASE 25.4
0
26.
5
0
26.0
0
27
.
6
0
28
.
1
0
27.60
28.10
52'± EXPOSE
OUTSIDE OF
CHASE
27
.
3
2
27.92
28.00
27
.
0
0
29.3
3
29.33 29.10
28.90
29.0
0
29.00
29.50 28.50
28.0
8
27.
0
0
32'± EXPOSE
OUTSIDE OF
CHASE
25.50
25.50
26.50
26.00
25
.
9
0
26.0
0
26.50
27.4
2
26.92
27
.
5
0
26.83
27.
4
0
27.4
2
27.9
2
27.5
0
25.70
25.20
25
.
1
0
25
.
2
0
26.5
0
26
.
5
0
25.06
24
.
8
4
24.88
26.50
24.82
24
.
9
5
25.46
25.4224.
9
3
24
.
7
9
24.8
3
25.326'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
BIKE RACKS
28.6428.84
29.16
29
.
2
1
26'
FLUSH
CURB
29.3
2
29.38
9.50'
FLUSH
CURB
32.3
1
32.9432.21
31
.
7
1
31
.
8
1
32.43
31.6
9 32
.
3
2
32.7032.0
8
31.9
7
31.59
31.30
31.4
4
31.6731.49
31.8
4
31
.
9
5
32.46
31.45
31.35
31.7
2
31.6
4 31.
2
7
30.77
31.0
4
31.54
30.6
5
30.87
31.37
30.
7
4
30.50
30.50
30.5
2
30.
6
4
30.57
31.30
30.
9
4
30.92 30.4
2
30.4
2
30.42
30.4
2
30.6
8
HANDICAP
PARKING SIGN
HANDICAP
PARKING SIGN
21'
FLUSH
CURB
WARPED
CONCRETE
LANDING
RAMP
RAMP
LANDING
RAMP
RAMP
RAMP
CURB
CURB
V.P.
(30
.
2
0
)
(29
.
7
9
)
(29.7
3
)
RAMP (REFER TO
ARCHITECTURAL PLANS)
STAIR TOWER
LANDING FFE = 35.50
LANDING
LANDING
PATIO
27.6
9
29.3329.33
29.3
3
29.
3
3
29
.
2
9
29.8829.88
29
.
2
9
30.0
0
30.0
0
29.92
29.33
29.3
3
29.3
3
35.5
0
35.36
28.98
35.36
30.0
0
35
.
5
0
35.3
6
35.2
6
33.11
33.0533.19
32.99
32.93
32.4
3
32.8
9
32.9
7
33.01
32.
0
8
32
.
3
0
32
.
0
8
32.21
30.73
30.18
(30
.
6
0
)
29.9
8 29.3
9
29.3
4
29.28
30.
2
0
(3
0
.
2
8
)
(3
0
.
3
4
)
(3
0
.
3
9
)
(3
0
.
5
0
)
29.
8
9
28.6
5
28
.
4
1
30.50
EXPOSED
WALL
(30
.
9
2
)
FFE=30.00
1.0' LANDSCAPE
WALL (BY OTHERS)
01.18.17
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 26
C3.03
DE
T
A
I
L
E
D
G
R
A
D
I
N
G
P
L
A
N
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
LEGEND:
EXISTING DECID. TREE
EXISTING CONIF. TREE
EXISTING LIGHT POLE
EXISTING STUMP
ST EXISTING STORM SEWER LINE
EXISTING CURB/GUTTER FLOWLINE
EXISTING EDGE OF ASPHALT
50
4:1 GROUND SLOPE
PROPOSED ASPHALT CROSS SLOPE
CONCENTRATED FLOW DIRECTION
PROPOSED SWALE FLOWLINE
PROPOSED INFLOW CURB/GUTTER FLOWLINE
PROPOSED STORM DRAIN WITH INLET
PROPOSED CONTOUR
79.45 PROPOSED FINISHED GROUND ELEVATION
(79.45)
EXISTING GROUND ELEVATION
PROPOSED OUTFALL CURB/GUTTER FLOWLINE
BENCHMARK/BASIS OF BEARING
NOTES:
1.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR
PROTECTION FROM THE 100-YEAR STORM.
2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE
WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK.
BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
3.EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL
FOLLOW CITY REGULATIONS.
4.REFER TO SITE PLAN, LANDSCAPE PLAN, AND PLAT FOR ADDITIONAL INFORMATION.
5.THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL
EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE
POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO
INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN
MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO
MODIFY THE DESIGN.
6.ADD 5000-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS, WHERE
TRUNCATED.
7.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED ARCHITECTURAL AND
LANDSCAPE ARCHITECTURE DRAWINGS FOR ALL STEPS, RAMPS, CHEEK WALLS, AND
HANDRAILS.
8.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED STRUCTURAL DRAWINGS
FOR ELEVATIONS AND GRADE CONDITIONS ALONG BUILDING PERIMETER. NOTIFY OWNER,
ARCHITECT, AND ENGINEER(S) OF ANY DISCREPANCIES PRIOR TO MOBILIZATION.
2.0%
PROJECT DATUM: NAVD 88
BENCHMARK #1:
CITY OF FORT COLLINS BENCHMARK 29-92: APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT
RD. AND SHIELDS ST., ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL.
ELEVATION: 5025.67
BENCHMARK #2:
CITY OF FORT COLLINS BENCHMARK 28-92: SOUTHWEST CORNER OF WEST PROSPECT RD. AND
CENTER AVE., ON A WATER VALVE PIT.
ELEVATION: 5010.65
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING
DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17.
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHWEST QUARTER OF SECTION 14,
TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M. AS BEARING SOUTH 89°22'14" EAST
----
KEYMAP
( IN FEET )
010 10 20 30
1 INCH = 10 FEET
A
B
D
C
B WEST SIDE DETAILED GRADING C EAST SIDE DETAILED GRADING
D SOUTH SIDE DETAILED GRADING
A NORTH SIDE DETAILED GRADING
X
X
X
X
X
X
X
X
X
C.O.
D
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
DD
E E E
E
E E
E
E
E E
UD
UD
UD
UD
UD
UD
E
E
ST
BEND C8
INV. IN=5026.44 (W)
INV. OUT=5026.44 (SE)
FG=5029.060
COMBINATION INLET C9
INV. OUT=5026.52 (E)
FL=5028.939
SUMP=5025.50
UN
D
E
R
G
R
O
U
N
D
PO
N
D
D
STORM DRAIN LINE C
SEE SHEET C2.02
STORMTECH CHAMBERS
(SC-160 CELLS)
SEE DETAILS
29.88
FG 30.12
FG
28.9
9FG
29
.
2
3
FG
25
.
9
9
26.1
2
26
.
1
0
0.2%
0.
2
%
0.2%
0.
2
%
25
.
9
7
PVC GEOMEMBRANE
PVC GEOMEMBRANE
MONITORING WELL C5-1
INV. OUT=5026.12 (N)
WATER QUALITY BASIN C7
(SEE DETAIL SHEET C7.05)
INV.=5026.35 (E)
FG=5029.130
60
.
4
9
L
F
6
"
P
E
R
F
.
P
V
C
@
0
.
2
1
%
4.36 LF 8" PVC @ 1.75%
3.59 LF 8" PVC @ 2.63%
OUTLET STRUCTURE C5
INV. IN=5026.00 (S)
INV. IN=5026.34 (W)
INV. OUT=5025.69 (NE)
FG=5029.235
72
.
1
3
L
F
8
"
P
V
C
@
0
.
5
0
%
STRM JUNCTION A11-1
INV. IN=5027.91 (E)
INV. OUT=5027.91 (SW)
FG=5030.201
14.65 LF 8" PVC @ 0.50%
ROOF LEADER A11-2
INV.=5027.98 (W)
FG=5030.144
2.74 LF 8" PVC @ 0.20%
STRM JUNCT C6
INV. IN=5026.34 (S)
INV. IN=5026.34 (W)
INV. OUT=5026.34 (E)
4.15 LF 8" PVC @ 0.20%
INSPECTION PORTS (TYP.)
ISOLATOR ROW
SEE PLUMBING
DRAWINGS FOR
CONTINUATION
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
C.O.D
C.O.
D
D
D C.O.
C.O.
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST ST ST ST
DD
C.O.
UN
D
E
R
G
R
O
U
N
D
PO
N
D
B
MONITORING WELL A4-7
INV. OUT=5026.86 (S)
FG=5030.824
MONITORING WELL A4-5
INV. IN=5026.08 (NW)
INV. OUT=5026.08 (E)
FG=5031.920
STORMTECH CHAMBERS
(SC-310 CELLS)
SEE DETAILS
30.79
FG
31.6
6
FG
31.79
FG
31.3
9FG
???
???
0.2%
0.
2
%
0.2%
0.2%
0.
2
%
0.2%
0.
2
%
??
?
ISOLATOR ROW
???
30.5
6FG
26.90
26.8
7
31.6
4
FG
??
?
PVC GEOMEMBRANE
PVC GEOMEMBRANE
PVC
GEOMEMBRANE
33.79 LF 6" PVC @ 1.83%
94.94 LF 6" PERF. PVC @ 0.20%
ROOF LEADER A10-1
INV.=5028.77 (W)
FG=5030.738
55.02 LF 8" PVC @ 1.00%
DRAIN BASIN A10
INV. IN=5028.22 (E)
INV. IN=5027.30 (N)
INV. OUT=5027.30 (S)
FG=5031.057
ISOLATOR ROW
DRAIN BASIN A11
INV. IN=5027.37 (W)
INV. IN=5027.55 (NE)
INV. OUT=5027.38 (S)
FG=5030.739
STRM JUNCT A9-2
INV. IN=5027.21 (N)
INV. OUT=5027.21 (E)
STRM JUNCTION A7
INV. IN=5026.61 (N)
INV. OUT=5026.61 (E)
INV. OUT=5026.61 (S)
4.75 LF 8" PVC @ -0.20%
6.19 LF
8" PVC
@ 0.20%
DRAIN BASIN A12
INV. IN=5027.58 (NW)
INV. OUT=5027.39 (S)
INV. OUT=5027.39 (E)
FG=5030.631
5.49 LF 8" PVC @ 2.20%
STRM JUNCTION A6-2.1 (S)
INV. IN=5026.63 (N)
INV. OUT=5026.63 (E)
9.50 LF 8" PVC @ -0.20%
COMBINATION INLET A13
INV. OUT=5027.70 (SE)
FL=5030.510
72.13 LF 8" PVC @ 0.50%
INSPECTION
PORTS (TYP.)
WATER QUALITY BASIN A9
INV. IN=5027.18 (N)
INV. OUT=5026.68 (SE)
MONITORING WELL A4-6
INV. IN=5026.70 (N)
INV. OUT=5026.70 (SE)
3.08 LF 8" PVC @ 0.20%
3.09 LF 8" PVC @ 0.20%
DRAIN BASIN A9-1
INV. IN=5027.21 (W)
INV. OUT=5027.21 (E)
8.93 LF 8" PVC @ 0.20%
STRM JUNCT A9
INV. IN=5027.20 (N)
INV. IN=5027.20 (W)
INV. OUT=5027.20 (S)
78
.
3
2
L
F
6
"
P
E
R
F
.
P
V
C
@
0
.
2
0
%
ISOLATOR ROW
INSPECTION
PORT (TYP.)
SEE PLUMBING
DRAWINGS FOR
CONTINUATION
01.18.17
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 26
C3.01
SU
B
G
R
A
D
E
P
L
A
N
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
GRAPHIC SCALE:
( IN FEET )
010 10 20 30
1 INCH = 10 FEET
NORTH
BASE COURSE
CONCRETE PAVEMENT
SUB-BASE
COURSE
STORMTECH SC-160 CHAMBER
TYPICAL STORMTECH SC-160 DETENTION CHAMBER
NOTE:
1.CONTRACTOR TO PROVIDE GEOFABRIC CLOAKING ON BOTTOM AND SIDES OF ALL
CHAMBER RETENTION AREAS.
2.FINAL DESIGN AND LAYOUT OF STORMTECH CHAMBERS BY OTHERS.
KEYMAP
LEGEND:
ST EXISTING STORM SEWER LINE
EXISTING CURB/GUTTER FLOWLINE
PROJECT BOUNDARY
27
4:1 GROUND SLOPE
PROPOSED PAVEMENT CROSS SLOPE
CONCENTRATED FLOW DIRECTION
PROPOSED UNDERDRAIN
PROPOSED INFLOW CURB/GUTTER FLOWLINE
PROPOSED STORM DRAIN WITH INLET
UD
PROPOSED CONTOUR
EXISTING CONTOUR
79.45 PROPOSED SUBGRADE ELEVATION
(79.45)
EXISTING GROUND ELEVATION
2.0%
POND D
POND B
----
MATCHLINE-SEE UPPER RIGHT
MATCHLINE-SEE LOWER LEFT
MA
T
C
H
L
I
N
E
-
S
E
E
SH
E
E
T
C3
.
0
2
6" SLOTTED PVC
UNDERDRAIN
BASE COURSE
CONCRETE PAVEMENT
SUB-BASE
COURSE
STORMTECH SC-310 CHAMBER
TYPICAL STORMTECH SC-310 DETENTION CHAMBER
NOTE:
1.CONTRACTOR TO PROVIDE GEOFABRIC CLOAKING ON BOTTOM AND SIDES OF ALL
CHAMBER RETENTION AREAS.
2.FINAL DESIGN AND LAYOUT OF STORMTECH CHAMBERS BY OTHERS.
6" SLOTTED PVC
UNDERDRAIN
6" (MIN.)
16" MIN.
VARIES
(44" MIN.)
6"
16"
VARIES
(6" MIN.)
14" MIN.
VARIES
(36" MIN.)
4"
12"
VARIES
(6" MIN.)
SUBGRADE
SUBGRADE
NOTES:
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER
SURVEY INFORMATION.
2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES
ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE
COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE
RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES.
3.ALL SPOTS SHOWN ARE SUBGRADE ELEVATIONS UNLESS OTHERWISE
NOTED.
4.CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER AND THE CITY OF
FORT COLLINS STORMWATER UTILITY A MINIMUM OF ONE WEEK IN
ADVANCE SO AS TO ALLOW FOR FIELD OBSERVATION AND
DOCUMENTATION OF THE FOLLOWING SYSTEM ITEMS IN THE
UNDERGROUND DETENTION AREAS:
- SUBGRADE
- INSTALLATION OF GEOTEXTILE FABRIC AND PVC GEOMEMBRANE
- INSTALLATION OF UNDERDRAIN AND STORMTECH CHAMBERS
- PLACEMENT AND COMPACTION OF SUB-BASE MATERIAL
- PLACEMENT AND COMPACTION OF BASE MATERIAL
5.SUBGRADE AREAS ARE TO BE FIELD SURVEYED BY A LICENSED
PROFESSIONAL. THE DESIGN ENGINEER MUST CONFIRM THE SUBGRADE
ELEVATIONS AND DIMENSIONS PRIOR TO PLACEMENT OF GEOTEXTILE
FABRIC, SUB-BASE, OR ANY OTHER MATERIAL.
6.THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM
INSTALLATION, PREVENT SEDIMENT, DEBRIS, AND DIRT FROM ANY SOURCE
FROM ENTERING THE CHAMBER SYSTEM.
7.GENERAL CONTRACTOR SHALL CONVENE A PRE-CONSTRUCTION MEETING
TO ENSURE THAT ALL SUBCONTRACTORS HAVE AN UNDERSTANDING OF
HOW THE CHAMBER SYSTEM IS INTENDED TO FUNCTION. CONTRACTOR
SHOULD DISCUSS THE PROPOSED SEQUENCE OF CONSTRUCTION AND
IDENTIFY ACTIVITIES THAT MAY REQUIRE PROTECTION OF THE SYSTEM.
8.THE CONTRACTOR SHOULD PROVIDE SLACK IN GEOTEXTILE FABRIC TO
ENSURE PROPER INSTALLATION AND AGGREGATE PLACEMENT WITHOUT
DAMAGE. PROVIDE SUFFICIENT SLACK SO THE FABRIC IS NOT TORN WHEN
ROCK IS PLACED. IF TEARS ARE SEEN OR DISCOVERED, REPAIR THEM AS
RECOMMENDED BY MANUFACTURER WITH NO LESS THAN 18 INCHES OF
OVERLAP ON ALL SIDES OF THE TEAR.
9.SEE SHEETS C7.04-C7.08 AND PLANS BY ADS FOR ADDITIONAL DESIGN
INFORMATION.
10.CHAMBER LAYOUT SHOWN IN THESE PLANS IS FOR REFERENCE ONLY.
FINAL CHAMBER LAYOUT AND DESIGN SHALL BE PER MANUFACTURER.
CURRENT DESIGN AND SPECIFICATIONS PROVIDED BY ADS (ADS PROJECT
#164679).
THESE
R
E
C
O
R
D
D
R
A
W
I
N
G
S
,
P
R
O
D
U
C
E
D
B
Y
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
SERVIC
E
S
,
I
N
C
.
,
A
R
E
B
A
S
E
D
I
N
W
H
O
L
E
,
O
R
I
N
P
A
R
T
,
U
P
O
N
I
N
F
O
R
M
A
T
I
O
N
PROVID
E
D
B
Y
O
T
H
E
R
S
.
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
S
E
R
V
I
C
E
S
,
I
N
C
.
A
S
S
U
M
E
S
NO LIAB
I
L
I
T
Y
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
T
H
I
S
I
N
F
O
R
M
A
T
I
O
N
.
RECOR
D
D
R
A
W
I
N
G
XXXXXXXX
CC CC
D
C.O.
C.O.
D
ST
ST
ST ST ST ST ST ST ST ST
ST ST ST ST ST ST ST ST ST
ST
D
C.O.
C.O.
ST
ST
UNDERGROUND
POND B
STORM DRAIN LINE A
SEE SHEET C2.01
MONITORING WELL A4-4
INV. IN=5025.90 (W)
INV. OUT=5025.90 (NE)
FG=5031.552
30.96
FG
31
.
5
6
FG
31.6
8
FG 32.11FG
31.4
2
FG
31
.
1
2
FG
30.99FG
25.95
25.
7
9
25
.
7
1
25.8
9
25.9
1
0.
2
%
0.2%
0.
2
%
0.
2
%
0.2%0.2%
ISOLATOR ROW
25
.
9
6
PVC GEOMEMBRANE
PVC GEOMEMBRANE
PVC GEOMEMBRANE
PVC GEOMEMBRANE
6.68 LF 6" PERF.
PVC @ 0.28%
4.2
2
L
F
6" P
V
C
@ 1
.
1
1
%
STRM JUNCT A4-1
INV. IN=5025.58 (W)
INV. OUT=5025.58 (SE)
13.90 LF 6" PVC @ 1.10%
DRAIN BASIN A4
W/ ORIFACE PLATE
INV. IN=5025.53 (NW)
INV. IN=5025.53 (SW)
INV. OUT=5025.53 (NE)
FG=5031.482
STRM JUNCTION A6-3 (S)
INV. IN=5026.28 (W)
INV. OUT=5026.28 (N)WATER QUALITY BASIN A6-4 (S)
INV. IN=5026.67 (SW)
INV. OUT=5026.45 (E)
AREA INLET A6-5
INV. OUT=5027.07 (NE)
20
.
2
0
L
F
8
"
P
V
C
@
2
.
0
0
%
MONITORING WELL A4-3
INV. IN=5025.88 (SW)
INV. OUT=5025.88 (E)12.38 LF 8" PVC @ 2.00%
STRM JUNTION A6-2.1 (N)
INV. IN=5027.07 (N)
INV. OUT=5027.07 (SW)
FG=5032.833
16.93 LF 8" PVC @ 2.00%
ROOF LEADER A6-2.2 (N)
INV. OUT=5027.41 (S)
94.94 LF 6" PERF. PVC @ 0.20%
4.74 LF 8" PVC @ 0.20%
WATER QUALITY BASIN A6-2 (N)
INV. IN=5026.22 (W)
INV. IN=5026.82 (NE)
INV. OUT=5026.26 (S)
9.50 LF 8" PVC @ 0.20%
STRM JUNTION A6-2 (S)
INV. IN=5026.26 (S)
INV. IN=5026.26 (W)
INV. OUT=5026.26 (N)
STRM JUNTION A6-1 (S)
INV. IN=5026.25 (S)
INV. OUT=5026.25 (N)
4.75 LF 8" PVC @ 0.20%
4.74 LF 8" PVC @ 0.20%
OUTLET STRUCTURE A6
INV. IN=5026.24 (W)
INV. IN=5026.24 (S)
INV. IN=5026.24 (N)
INV. OUT=5025.57 (E)
FG=5031.838
25.9
7
ISOLATOR ROW
0.2%
STORMTECH CHAMBERS
(SC-740 CELLS)
SEE DETAILS
INSPECTION PORT (TYP.)
4.76 LF 8" PVC @ 0.20%
STRM JUNTION A6-1 (N)
INV. IN=5026.25 (N)
INV. OUT=5026.25 (S)
MONITORING WELL A4-2
INV. IN=5025.72 (W)
INV. OUT=5025.73 (E)
78.25 LF 6" PERF. PVC @ 0.20%
DRAIN BASIN A5
INV. IN=5025.56 (W)
INV. OUT=5025.56 (NE)
01.18.17
Sheet
ST
A
D
I
U
M
A
P
A
R
T
M
E
N
T
S
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
PH
O
N
E
:
9
7
0
.
2
2
1
.
4
1
5
8
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
of 26
C3.02
SU
B
G
R
A
D
E
P
L
A
N
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
GRAPHIC SCALE:
( IN FEET )
010 10 20 30
1 INCH = 10 FEET
NORTH
1.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER
SURVEY INFORMATION.
2.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES
ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE
COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE
RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES.
3.ALL SPOTS SHOWN ARE SUBGRADE ELEVATIONS UNLESS OTHERWISE
NOTED.
4.CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER AND THE CITY OF
FORT COLLINS STORMWATER UTILITY A MINIMUM OF ONE WEEK IN
ADVANCE SO AS TO ALLOW FOR FIELD OBSERVATION AND
DOCUMENTATION OF THE FOLLOWING SYSTEM ITEMS IN THE
UNDERGROUND DETENTION AREAS:
- SUBGRADE
- INSTALLATION OF GEOTEXTILE FABRIC AND PVC GEOMEMBRANE
- INSTALLATION OF UNDERDRAIN AND STORMTECH CHAMBERS
- PLACEMENT AND COMPACTION OF SUB-BASE MATERIAL
- PLACEMENT AND COMPACTION OF BASE MATERIAL
5.SUBGRADE AREAS ARE TO BE FIELD SURVEYED BY A LICENSED
PROFESSIONAL. THE DESIGN ENGINEER MUST CONFIRM THE SUBGRADE
ELEVATIONS AND DIMENSIONS PRIOR TO PLACEMENT OF GEOTEXTILE
FABRIC, SUB-BASE, OR ANY OTHER MATERIAL.
6.THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM
INSTALLATION, PREVENT SEDIMENT, DEBRIS, AND DIRT FROM ANY SOURCE
FROM ENTERING THE CHAMBER SYSTEM.
7.GENERAL CONTRACTOR SHALL CONVENE A PRE-CONSTRUCTION MEETING
TO ENSURE THAT ALL SUBCONTRACTORS HAVE AN UNDERSTANDING OF
HOW THE CHAMBER SYSTEM IS INTENDED TO FUNCTION. CONTRACTOR
SHOULD DISCUSS THE PROPOSED SEQUENCE OF CONSTRUCTION AND
IDENTIFY ACTIVITIES THAT MAY REQUIRE PROTECTION OF THE SYSTEM.
8.THE CONTRACTOR SHOULD PROVIDE SLACK IN GEOTEXTILE FABRIC TO
ENSURE PROPER INSTALLATION AND AGGREGATE PLACEMENT WITHOUT
DAMAGE. PROVIDE SUFFICIENT SLACK SO THE FABRIC IS NOT TORN WHEN
ROCK IS PLACED. IF TEARS ARE SEEN OR DISCOVERED, REPAIR THEM AS
RECOMMENDED BY MANUFACTURER WITH NO LESS THAN 18 INCHES OF
OVERLAP ON ALL SIDES OF THE TEAR.
9.SEE SHEETS C7.04-C7.08 AND PLANS BY ADS FOR ADDITIONAL DESIGN
INFORMATION.
10.CHAMBER LAYOUT SHOWN IN THESE PLANS IS FOR REFERENCE ONLY.
FINAL CHAMBER LAYOUT AND DESIGN SHALL BE PER MANUFACTURER.
CURRENT DESIGN AND SPECIFICATIONS PROVIDED BY ADS (ADS PROJECT
#164679).
KEYMAP
LEGEND:
ST EXISTING STORM SEWER LINE
EXISTING CURB/GUTTER FLOWLINE
PROJECT BOUNDARY
27
4:1 GROUND SLOPE
PROPOSED PAVEMENT CROSS SLOPE
CONCENTRATED FLOW DIRECTION
PROPOSED UNDERDRAIN
PROPOSED INFLOW CURB/GUTTER FLOWLINE
PROPOSED STORM DRAIN WITH INLET
UD
PROPOSED CONTOUR
EXISTING CONTOUR
79.45 PROPOSED SUBGRADE ELEVATION
(79.45)
EXISTING GROUND ELEVATION
2.0%
POND B
----
MA
T
C
H
L
I
N
E
-
S
E
E
SH
E
E
T
C3
.
0
1
NOTES:
BASE COURSE
18" MIN.
VARIES
(60" MIN.)
CONCRETE PAVEMENT
SUB-BASE
COURSE
STORMTECH SC-740 CHAMBER
6"
30"
VARIES
(6" MIN.)
TYPICAL STORMTECH SC-740 DETENTION
CHAMBER
NOTE:
1.CONTRACTOR TO PROVIDE GEOFABRIC CLOAKING ON BOTTOM AND SIDES OF ALL
CHAMBER RETENTION AREAS.
2.FINAL DESIGN AND LAYOUT OF STORMTECH CHAMBERS BY OTHERS.
6" (MIN.)
SUBGRADE
ELEVATION
6" SLOTTED PVC
UNDERDRAIN
THESE
R
E
C
O
R
D
D
R
A
W
I
N
G
S
,
P
R
O
D
U
C
E
D
B
Y
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
SERVIC
E
S
,
I
N
C
.
,
A
R
E
B
A
S
E
D
I
N
W
H
O
L
E
,
O
R
I
N
P
A
R
T
,
U
P
O
N
I
N
F
O
R
M
A
T
I
O
N
PROVID
E
D
B
Y
O
T
H
E
R
S
.
N
O
R
T
H
E
R
N
E
N
G
I
N
E
E
R
I
N
G
S
E
R
V
I
C
E
S
,
I
N
C
.
A
S
S
U
M
E
S
NO LIAB
I
L
I
T
Y
F
O
R
T
H
E
A
C
C
U
R
A
C
Y
O
R
C
O
M
P
L
E
T
E
N
E
S
S
O
F
T
H
I
S
I
N
F
O
R
M
A
T
I
O
N
.
RECOR
D
D
R
A
W
I
N
G