HomeMy WebLinkAboutLot Certifications - 08/24/2017 (2)CERTIFICATIO N OF LO T GRADIN G
Pursuan t to Fort CoHin s City Cod e § 26-544 & City Lan d Use Cod e § 3.3.2 (e}
Date: Aug. 24, 2017
Address: 1334 Leahy Drive
Fort Collins, CO 80526
Lot: 9 Block:
Subdivision
Permit Applicatio n #
Larimer County Parcel #
Larimer County Reception #
{on developmen t agreement)
Registry Ridge 6th filing
B160620 9
9615125009
2011002877 8
I, (print) Dennis R. Messner _, a Colorado registered professiona l engineer, verify that constructio n
of all stormwater facilitie s and grading is complete and hereby submit this certification .
Please answer the following questions by initialing the appropriate response . For each questio n initiale d "No," attach an
explanation detailing how this will affect stormwate r drainage for this lot and any adjacent lots.
Certification includes attached Stormwater-approve d grading plan. {NOTE: City's
Building Departmen t does not approve grading plans).
No .Yes J.
2. Certificatio n includes the attached as-buil t survey dated ^ ^ 1 ' 1 ^ (must be within 50 No
days of the date the certificatio n is submitted) accurately and truthfully depictin g
elevation s for:
• Top of foundation/finishe d floor
• Finished grade on each side of the structur e
• Quarter points along each lot line (not more than 50 feet apart)
• Break points/hig h points
• Swales
• Berms
• Retainin g walls
• Air conditionin g pads
• Windo w wells
• Any other appurtenance{s ) within an easemen t
3. All elevations are within a 0.2 foot tolerance of the approve d grading plan.
4. The top of foundation is at least 6 inches above the highest grade surrounding the
structure .
5. There is a minimum grade of 5% away from the structure within the first 5 to 10 feet
adjacent to the residence .
6. All slopes meet or exceed the minimum requiremen t of 2% ( 1 % is acceptabl e on single
family lots when the swale is draining the runoff from only two adjoinin g properties)
and are not steeper than 33% (3:1).
7. All flow lines of stormwate r drainage swales are a minimu m of 6 inches below the
elevation of ground adjacen t to the structure and will direct drainag e as shown on the
Stormwater-approve d grading plan.
8. All downspou t locations and discharge directions are shown on the as-buil t survey.
Runoff is directed into an appropriat e drainage system or lot line swale, and it is not
directed onto neighboring properties .
Ye s /tfX-'-^t-t ..
N o r^ Y es
No Ye s xM^^'
No Yes
No
No
No
Ye s /}l.f-^\. .
Yes
Page i
9. A smooth transition with no vertical offset (step) in grade is provided at the lot line to all No Ye s
Mil
adjacent properties . 10 . The grading of this lot does not adversely affect neighborin g properties or City N o Ye s
infrastructure .
11 . Landscapin g has been complete d prior to survey. If not, please indicate who will be No ^^yj^/ Yes.
responsible for completin g landscaping : Future Owner
12 . Final site cleanup has been completed .
13. I personally visited the site as part of the certificatio n process , and in my professiona l
opinion , the as-built survey is an accurate representatio n of the site conditions.
mi
N o J C * l Y es
No . Y e s ^ -H
14 . Based on this information , I certify that (check one):
• The elevations and drainage patterns of the lot/site are in substantia l conformanc e with the City
approved drainage and grading plan for the propert y (informatio n attached).
The elevation s and drainage pattern s of the lot/site as measured are in general conformanc e with the
City approved drainage plan with exceptions (information attached). In my professiona l judgment the
elevation s and gradin g of the lot/site as constructed are functionall y adequate and equivalen t to the
specifically approve d drainage plan, and will affect stormwate r drainag e on and off the lot/site in a
manner consisten t with the approved drainage plan.
Sign and date
Name: Dennis R, Messner
Email : dennismessner45@gmail.co m
Phone: (970) 402-4360
Company: Dennis R. Messner, P. E.
Address; 2015 Buena Vista Place
Loveland , CO 80538
NOTE : A complete certificatio n must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including, but not limited to, drawings of the lot/site showing the approved design and as-built surveye d
elevations of all structures , drainage and grading features , written information/explanatio n of discrepancies , and other
informatio n necessar y to confirm the above certificatio n to:
Emai l (preferred ) '
WaterUtilitiesEng(a)fcgQv.co m
Mailing Addres s
Fort Collins Utilities
ATTN : Water Utilities Engineerin g
281 North College Avenue
Fort Collins, CO 80521
Questions ?
970-221-670 0
_ C i t y o s _
Fort Collin s
2/14/17 Page 2
Certification of Lot Grading Aug. 24, 2017
Lot 9, Registry Ridge 6 th Filing, City of Fort Collins, Larimer County, Colorado
1334 Leahy Dr., Fort Collins, CO 80526
Building Permit No.: B1606209
Explanation for Certification Item No. 3: The constructed spot elevations vary more and less than 0.2
foot of those depicted on the approved grading plan but the intended drainage pattern is retained.
Explanation for Certification Item No. 11: The landscaping has not been completed. The future home
owner is responsible for installation and maintenance of landscaping.
Explanation for Certification Item No. 12: An initial clean up has been performed. The final clean up
will be performed following installation of landscaping.
Description:
Lot 9, Registry Ridge Sixth Filing, City of
Fort Collins, Larimer County, Colorado
Notes:
-Street address is 1321 Leahy Drive, Fort Collins, CO
-This is not a monumented land survey.
-Lot dimensions shown are per plat and not measured.
-All spots are shown to finished grade elevation.
AC
ww
DS
LEGEND:
air conditioning unit
window well
downspout
downspout discharge direction
gas meter
sanitary sewer cleanout
telecommunications pedestal
water meter
fire hydrant
high point
NOTICE: According to Colorado law you must
commence any legal action based upon any defect in
this survey within three years after you first discover
such defect. In no event, may any action based upon
any defect in this survey be commenced more than ten
years from the date of the certification shown hereon.
Prepared for:Project#:Field Date
Proj. Manager
Scale
R e v i s i o n s#Date
Party Chief
Survey Tech
6843 North Franklin Avenue
Loveland, Colorado 80538
Office 970.669.2100 - Fax 970.669.3652
PLS Group
14071.033
Insignia Homes, LTD
8.21.2017
ADS
MDG
MBS
1" = 20'
HP