HomeMy WebLinkAboutSite Certifications - 11/09/2020 October 21, 2020 Wes Lamarque City of Fort Collins 700 Wood Street Fort Collins, CO 80522 RE: Permit: B1904507 – NEC Lake & Shields Fort Collins, Colorado Dear Mr. Lamarque: This Overall Site and Drainage Certification Letter is provided to verify as-constructed conditions for NEC Lake & Shields. Majestic Surveying completed survey work October 8, 2020, to verify general compliance with the Final Utility Plans for NEC Lake & Shields, dated August 22, 2019, and the Minor Amendment dated May 21, 2020, by Northern Engineering. Included in this drainage certification submittal are the following: Appendix A - City of Fort Collins Overall Site and Drainage Certification Form. Appendix B - City of Fort Collins During Construction Inspection Checklist and photographs provided by contractor. Appendix C - As-constructed detention pond calculations. Appendix D - As-constructed record drawings for Grading and Storm Drain Plan and Profile Sheets. Appendix E - Documents provided to the Colorado State Drain Portal website. We have concluded, based on the attached information and personal site inspection, that the drainage features for the project site have been constructed in substantial compliance with the above referenced Final Utility Plans, with the following exceptions: · Item I.B.3.a,b,d: Spillway is for both ponds are the adjacent sidewalks onto pavement. · Item I.B.3.e: Spillway path is onto pavement. · Item I.B.4.c: Water quality in vault is being provided by sand filter. · Item II.B.3: The small swales on the west side of the building between the playground and the sidewalk lost definition during the landscaping phase of the project. This was determined to not be of any major concern due to the drainage basins still functioning as intended and the small amount of drainage handled by these inlets. · Item III.A.2: Storm pipe between FES A and Basin A1 was designed at 0.2% due to utility conflicts. As -built information indicates that the pipe was constructed slightly flatter (0.10%) to maintain required separation. Through analysis it has been determined that the flatter pipe still passes the 100-yr event and performs as designed · Item III.B.3: Northern Engineering did not observe construction. Northern Engineering was unable to verify the joint types or construction methods used for the storm drain pipes. · Item IV.A.4: Northern Engineering did not observe construction. Northern Engineering was unable to verify the concrete thickness and reinforcement used, if any. · Item XII.A: South pond has been seeded and is in the process of stabilization. Northern Engineering is unaware if this area has been coordinated between the contractor and the Erosion Control Inspector. · Item XIII.C: The excavated area for the rain garden survey was not provided to Northern Engineering, nor were the depths of the bioretention material or aggregate, so verification on those items cannot be supplied. The material and its installation was observed by a City of Fort Collins Erosion Control Inspector and photo have been provided by the contractor. Bottom area and depth of rain garden meets/exceeds design requirement. Item XV: Stabilization and final landscaping still occurring in the south pond. Please feel free to contact me with any questions you may have. Northern Engineering Services, Inc. Benjamin Ruch, PE Project Engineer 10/21/20 Appendix A Overall Site and Drainage Certification Form Appendix B During Construction Inspection Checklist 1/19 Page 1 of 2 DURING CONSTRUCTION INSPECTION CHECKLIST To be completed by Construction Superintendent This checklist is to be completed during construction and included with the Overall Site and Drainage Certification. Use “Yes” for items completed as described. Use “N/A” for items that are not applicable to the site being certified. If any blanks are “No,” attach an explanation referencing the item number below. Project Name: Date: Building Permit Numbers: I. Compaction A. All berms and embankments meet the compaction requirements as specified in the project geotechnical report or comply with the City’s standard, which is “soils should be compacted within a moisture content range of 2% below to 2% above optimum moisture content and compacted to 95% of the Maximum Standard Proctor Density (ASTM D698).” Compaction requires verification during construction. Provide testing log from contractor/engineer. II. Storm Drain Pipe Installation Requirements A. The pipe trenches have been compacted in accordance with Section 02225-3.07.A.1. of the Fort Collins Development Construction Standards for Water, Wastewater, Stormwater (e.g., the trenches in the roadways are to be 95% of maximum density and all other areas are to be at 90%, both in accordance with ASTM D698). III.Energy Dissipation and Erosion Protection - FCSCM Chapter 9, Section 7.0 A.Riprap 1. The riprap bedding is a granular bedding of the gradation and thickness indicated on the approved construction plans. 2. A filter fabric was installed instead of granular bedding and is the material shown on the approved construction plans or was an approved equal. Provide documentation for an approved equal. 3. The riprap is the gradation shown on the approved construction plans with a D50 of . 4. The riprap thickness is as shown on the approved construction plans and extends to the horizontal limits shown. 5. The riprap is buried to the depth indicated on the approved construction plans. (A minimum of 6 inches of soil is required.) B. Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7 1. All fabric was installed per manufacturer’s specifications. Sunshine House #213 B1904507 N/A Yes N/A N/A N/A N/A N/A Yes 10/12/20 1/19 Page 2 of 2 IV. Other Permanent BMPs A. All cut-off walls have been installed in accordance with the approved construction plans. (Cut-off walls are required for irrigation ditch crossings of storm drain pipes.) V.Extended Detention Basins A. Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the water quality control box(es). Provide date of inspection and name of inspector: Included certification sheet(s): Please check the appropriate box(es) for the Low Impact Development (LID) facilities found on this site and complete the corresponding certification sheets. ☐ Permeable Interlocking Concrete Pavers ☐ Bioretention Cells (Rain Gardens) ☐ Sand Filters ☐ Vegetated Buffers ☐ Underground Infiltration ☐ Other LID – For certification of Dry Wells, Tree Filters, Constructed Wetland Channels & Ponds, etc., contact City Staff to determine requirements to exhibit the LID facility has been constructed and functions as intended per the approved drainage report. *Please provide photographic documentation of the installation of all stages of all LID facilities. **Please contact the City Stormwater Inspector at stormwaterinspection@fcgov.com to discuss inspection requirements for each LID facility and request inspections. ***All facilities being certified must be “clean” – free of sediment & construction debris – prior to certification or acceptance of the facility. Completed by: Name: Title: Email: Phone: Company: Address: N/A N/A x Rocky Ernest Project Manager rernest@gchconstruction.com 719-651-8228 GCH Construction Company 4496 Bents Drive, Unit C Windsor, CO 80550 1/19 Page 1 of 2 Permeable Interlocking Concrete Pavers Item/Activity Yes No N/A Submittal Requirements Submitted?/Response Stormwater Inspection Pre-construction meeting was held with City-Stormwater Inspector to discuss installation, inspection, checklist, and protection from sedimentation ☐☐☐ Record date, inspector name, meeting location (i.e. DCP, initial erosion control inspection, etc.) Sub-surface inspection(s): Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the outlet, underdrain, geomembrane layer, and sub-base courses (per design in Final Plan Documents) ☐☐☐ Record date(s) of inspection and inspector’s name Surface inspection(s): Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the pavers and joint fill material ☐☐☐ Record date(s) of inspection and inspector’s name Excavation Heavy equipment did not encroach into the excavated area (prevents over-compaction)☐☐☐ Bottom of cell was “ripped” after excavation ☐☐☐Provide photographs before and after “ripping” Bottom surface of cell is flat and level ☐☐☐Provide photograph Impermeable Liner Impermeable liner meets design specifications ☐☐☐Provide specifications of delivered material Impermeable liner is attached to concrete perimeter wall ☐☐☐Provide photograph Impermeable liner is buried with no exposure ☐☐☐ Any penetrations of the impermeable liner have been sealed and checked for water-tightness ☐☐☐Provide photograph (if necessary) Edge Restraint and Concrete Cut-Off Wall The required edge restraint meets design specifications ☐☐☐Provide specification of installation Concrete cut-off wall meets design specifications for: ☐☐☐Provide specification of installation - Dimensions ☐☐☐ - Reinforcement ☐☐☐ - Footings ☐☐☐ Underdrain System Underdrain pipe meets design specifications ☐☐☐Provide photograph At least one cleanout is provided per underdrain lateral ☐☐☐Provide photograph 1/19 Page 2 of 2 Cleanout pipe is solid (not perforated/slotted)☐☐☐Provide photograph Cleanout covers are installed and watertight ☐☐☐Provide photograph Verify the underdrain is NOT wrapped in geotextile fabric ☐☐☐Provide photograph Verify there is no orifice plate on the underdrain outfall ☐☐☐Provide photograph Underdrain integrity tested after backfilling using TV and/or water test ☐☐☐Provide documentation of test results Aggregate Sub-base Course(e.g., #2/4): - Has 90% fractured faces - Is thoroughly washed (virtually free of fine sediment) - Is installed to the required design depth ☐☐☐ Provide load ticket, photographs, and record depth installed Basecourse (e.g., #57): - Has 90% fractured faces - Is thoroughly washed (virtually free of fine sediment) - Is installed to the required design depth ☐☐☐ Provide load ticket, photographs, and record depth installed Leveling Course / Joint Fill (e.g., crushed #89): - Has 90% fractured faces - Is thoroughly washed (virtually free of fine sediment) - Is dry screened - Is installed to the required design depth and to the top of the paver joints ☐☐☐ Provide load ticket, photographs, and record depth installed Aggregate materials are installed and compacted according to manufacturer’s and/or design specifications ☐☐☐Provide photographs and documentation of compaction Protection During Construction PICP area is protected from construction site sediment, including runoff from the upstream catchment and construction equipment traffic ☐☐☐ Specify how the area was covered and/or otherwise protected to prevent construction runoff from entering the pavement Close Out Cracked/broken paver units have been removed and replaced ☐☐☐ Paver height offsets are no more than 1/4” between adjacent units & surface contains no deformations (depressions/settlement) exceeding 1/2" ☐☐☐ Upstream catchment is stabilized prior to diverting runoff into PICP system ☐☐☐ 1/19 Page 1 of 3 Bioretention Cells (Rain Gardens) Item/Activity Yes No N/A Submittal Requirements Submitted?/Response Stormwater Inspection Pre-construction meeting was held with City-Stormwater Inspector to discuss installation, inspection, checklist, and protection from sedimentation ☐☐☐ Record date, inspector name, meeting location (i.e. DCP, initial erosion control inspection, etc.) Underdrain and basecourse inspection(s): Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the outlet, underdrain, geomembrane layer, and base course (per design in Final Plan Documents) ☐☐☐ Record date(s) of inspection and inspector’s name Pea gravel and BSM inspection(s): Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the pea gravel and bioretention sand media ☐☐☐ Record date(s) of inspection and inspector’s name Excavation Heavy equipment did not encroach into the excavated area (prevents over-compaction)☐☐☐ Bottom of cell was “ripped” after excavation ☐☐☐Provide photographs before and after “ripping” Bottom surface of cell is flat and level ☐☐☐Provide photograph Excavated area is protected/surrounded by sediment/runoff control measures during construction ☐☐☐Provide photograph Intake Upstream catchment drains to inlet/bioretention cell per plan and flows are fully captured ☐☐☐ Forebay Forebay is installed according to design specifications ☐☐☐Provide photograph There is a minimum 3” drop at the forebay entrance ☐☐☐Provide photograph Forebay will drain fully and not hold standing water ☐☐☐ Outlet Structure/Overflow Emergency overflow elevation is confirmed ☐☐☐ Measure and record distance from overflow to top of media filter; provide photograph Overflow inlet elevation is set above bioretention media per plan ☐☐☐Provide photograph Complete 6/25/20 w/ Martha Cruse,Chris (TCE & Rocky (GCH) x x x x x x x x x x x x 7/28 & 7/29 Martha Cruse Equipment was only used to excavate and install this scope of work Photo 1 N/A N/A N/A See attached photo 7/28 & 7/29 Martha Cruse x see attached photo see attached photo 1/19 Page 2 of 3 Overflow inlet invert elevation is at least 3 inches below containment wall/berm (to direct overflow into inlet)☐☐☐ Measure and record distance between inlet and top of containment wall/berm; provide photograph Overflow path and check dams, if used, are armored to protect from erosion and maintain elevations ☐☐☐Provide photograph Impermeable Liner Impermeable liner meets design specifications ☐☐☐Provide specifications of delivered material Impermeable liner is appropriately anchored ☐☐☐Provide photograph Impermeable liner is buried with no exposure ☐☐☐ Any penetrations of the impermeable liner have been sealed and checked for water-tightness ☐☐☐Provide photograph (if necessary) Underdrain System Underdrain pipe meets design specifications ☐☐☐Provide photograph At least one cleanout is provided per underdrain lateral ☐☐☐Provide photograph Cleanout pipe is solid (not perforated/slotted)☐☐☐Provide photograph Cleanout covers are installed and watertight ☐☐☐Provide photograph Verify the underdrain is NOT wrapped in geotextile fabric ☐☐☐Provide photograph Verify there is no orifice plate on the underdrain outfall ☐☐☐Provide photograph Underdrain integrity tested after backfilling using TV and/or water test ☐☐☐Provide documentation of test results Filter Media and Aggregate Reservoir aggregate layer (ASTM #57 or #67): - meets design specifications - is installed to the required design depth ☐☐☐ Provide load ticket, photographs, and record depth installed Diaphragm aggregate layer (“Pea Gravel” with gradation ASTM #8, #89, or #9): - meets design specifications - is installed to the required design depth ☐☐☐ Provide load ticket, photographs, and record depth installed Bioretention Sand Media (BSM) composition: - meets design specifications - is installed to the required design depth ☐☐☐ Provide load ticket, photographs, and record depth installed BSM was “machine mixed” by supplier prior to delivery ☐☐☐Provide load ticket BSM is installed flat and level ☐☐☐Provide photograph Other Structural Components Containment wall/berm is continuous and level ☐☐☐ Landscaping x x x x x x x x x x x x x see attached photo see attached photo see attached photo see attached photo see attached photo & weight tickets see attached photo & weight tickets see attached photo & weight tickets see weight tickets see attached photos N/A see attached photo see attached photo see attached photo see attached photo 1/19 Page 3 of 3 Verify final landscaping is free of sod ☐☐☐If sod is used, it must be shown to be “sand-grown” Final landscaping (non-floatable mulch) is flat and level ☐☐☐Provide photograph Vegetation is planted according to landscape design specifications and final landscaping plan ☐☐☐Provide photograph Verify that weed barrier is NOT installed ☐☐☐ Temporary irrigation installed ☐☐☐ If N/A, then verify that permanent irrigation is installed to establish/maintain vegetation Close Out Upstream catchment stabilized prior to diverting runoff into bioretention cell ☐☐☐ x x x x x x run off is from concrete parking lots No weed barrier is installed No sod is installed Native plantings see attached photo 1/19 Page 1 of 1 Vegetated Buffers Item/Activity Yes No N/A Submittal Requirements Submitted?/Response Construction Buffer area was sectioned off to eliminate site disturbance and compaction during construction ☐☐☐Provide photograph(s) Level spreader has been installed per plan (if applicable)☐☐☐Provide photograph Soils in the buffer area have been amended ☐☐☐Record soil amendment certification with Environmental & Regulatory Affairs Vegetation is planted according to landscape design specifications and final landscaping plan ☐☐☐Provide photograph 1/19 Page 1 of 3 Sand Filters Item/Activity Yes No N/A Submittal Requirements Submitted?/Response Stormwater Inspection Pre-construction meeting was held with City-Stormwater Inspector to discuss installation, inspection, checklist, and protection from sedimentation ☐☐☐ Record date, inspector name, meeting location (i.e. DCP, initial erosion control inspection, etc.) Underdrain and basecourse inspection(s): Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the outlet, underdrain, geomembrane layer, and base course (per design in Final Plan Documents) ☐☐☐ Record date(s) of inspection and inspector’s name Pea gravel and filter media inspection(s): Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point of installation of the pea gravel and filter media ☐☐☐ Record date(s) of inspection and inspector’s name Excavation Heavy equipment did not encroach into the excavated area (prevents over-compaction)☐☐☐ Bottom of cell was “ripped” after excavation ☐☐☐Provide photographs before and after “ripping” Bottom surface of cell is flat and level ☐☐☐Provide photograph Excavated area is protected/surrounded by sediment/runoff control measures during construction ☐☐☐Provide photograph Intake Upstream catchment drains to inlet/sand filter per plan and flows are fully captured ☐☐☐ Forebay (If Applicable) Forebay is installed according to design specifications ☐☐☐Provide photograph There is a minimum 3” drop at the forebay entrance ☐☐☐Provide photograph Forebay will drain fully and not hold standing water ☐☐☐ Outlet Structure/Overflow Overflow inlet elevation is set above sand filter media per plan (typically 1 to 3 feet)☐☐☐Provide photograph Overflow inlet invert elevation is at least 3 inches below containment wall/berm (to direct overflow into inlet)☐☐☐ Measure and record distance between inlet and top of containment wall/berm; provide photograph 1/19 Page 2 of 3 Overflow path and check dams, if used, are armored to protect from erosion and maintain elevations ☐☐☐Provide photograph Impermeable Liner (If Applicable) Impermeable liner meets design specifications ☐☐☐Provide specifications of delivered material Impermeable liner is appropriately anchored to the perimeter wall ☐☐☐Provide photograph Impermeable liner is buried with no exposure ☐☐☐ Any penetrations of the impermeable liner have been sealed and checked for water-tightness ☐☐☐Provide photograph (if necessary) Underdrain System Underdrain pipe meets design specifications ☐☐☐Provide photograph At least one cleanout is provided per underdrain lateral ☐☐☐Provide photograph Cleanout pipe is solid (not perforated/slotted)☐☐☐Provide photograph Cleanout covers are installed and watertight ☐☐☐Provide photograph Verify the underdrain is NOT wrapped in geotextile fabric ☐☐☐Provide photograph Verify there is no orifice plate on the underdrain outfall ☐☐☐Provide photograph Underdrain integrity tested after backfilling using TV and/or water test ☐☐☐Provide documentation of test results Filter Media Filter media composition (e.g. ASTM C 33 Sand): - meets design specifications - is installed to the required design depth ☐☐☐ Provide load ticket, photographs, and record depth installed Pea gravel layer: - meets design specifications - is installed to the required design depth ☐☐☐ Provide load ticket, photographs, and record depth installed Filter Media is installed flat and level ☐☐☐ Other Structural Components Containment wall/berm is continuous and level ☐☐☐ Landscaping Verify final landscaping is free of sod ☐☐☐ If sod is used, it must be shown to be “sand-grown” Final landscaping (non-floatable mulch) is flat and level ☐☐☐Provide photograph Vegetation is planted according to landscape design specifications and final landscaping plan ☐☐☐Provide photograph Verify that weed barrier is NOT installed ☐☐☐ 1/19 Page 3 of 3 Temporary irrigation installed ☐☐☐ If N/A, then verify that permanent irrigation is installed to establish/maintain vegetation Close Out Upstream catchment stabilized prior to diverting runoff into sand filter cell ☐☐☐ 1/19 Page 1 of 2 Underground Infiltration Item/Activity Yes No N/A Submittal Requirements Submitted?/Response Stormwater Inspection Manufacturer’s representative pre-construction meeting: A pre-construction meeting was completed with the manufacturer’s representative and installers ☐☐☐ Record date and who was present at the meeting Pre-construction meeting was held with City-Stormwater Inspector to discuss installation, inspection, checklist, and protection from sedimentation ☐☐☐ Record date, inspector name, meeting location (i.e. DCP, initial erosion control inspection, etc.) Inspection(s): Installation of this facility was verified via inspection by a City-Stormwater Inspector at the point at which the chambers had been laid/prior to backfilling. Correct fabric placement was confirmed. ☐☐☐ Record date(s) of inspection and inspector’s name Excavation Heavy equipment did not travel across underground cell area during excavation (prevents over-compaction)☐☐☐ Bottom of cell was “ripped” after excavation ☐☐☐Provide photographs before and after “ripping” Bottom of cell is flat and level, or graded per approved grading plans ☐☐☐Provide photograph Non-woven fabric is installed per manufacturer’s specifications and was not damaged during construction (around system)☐☐☐Provide photograph Woven fabric is installed per manufacturer’s specifications and was not damaged during construction (beneath chambers)☐☐☐Provide photograph Excavated area is protected/surrounded by sediment/runoff control BMPs during construction ☐☐☐Provide photograph Impermeable Liner Impermeable liner meets design specifications ☐☐☐Provide specifications of delivered material Impermeable liner is not exposed ☐☐☐ Any penetrations of the impermeable liner have been sealed and checked for water-tightness.☐☐☐Provide photograph (if necessary) Aggregate Foundation and embedment materials are installed and compacted according to design and manufacturer’s specifications ☐☐☐ Provide load ticket and photograph(s) Underdrain System 1/19 Page 2 of 2 Underdrain pipe meets design specifications ☐☐☐Provide photograph At least one cleanout is provided per underdrain lateral ☐☐☐Provide photograph Cleanout pipe is solid (not perforated/slotted)☐☐☐Provide photograph Cleanout covers are installed and watertight ☐☐☐Provide photograph Verify the underdrain is NOT wrapped in geotextile fabric ☐☐☐Provide photograph Verify there is no orifice plate on the underdrain outfall ☐☐☐Provide photograph Underdrain integrity tested after backfilling using TV and/or water test ☐☐☐Provide documentation of test results Manifold system Overflow weir elevation is set at/above water quality storm elevation ☐☐☐Record weir elevation on survey Maintenance access is provided for each Isolator Row ☐☐☐ At least one inspection port has been provided for each Isolator Row (located in middle third of each row)☐☐☐ Upstream catchment drains to inlet/intake properly ☐☐☐ Underground Detention Chambers All chambers were installed per approved Utility Plans and manufacturer’s specifications ☐☐☐Photograph Close Out Upstream catchment is stabilized prior to diverting runoff into Underground Detention system ☐☐☐ All Isolator Rows, chambers, and pipes are cleaned and sediment/debris has been removed ☐☐☐ 8" installed 4" installed 18" installed Reservoir Aggregate Reservoir Aggregate Reservoir Aggregate Diaphram Aggregate Bioretention Sand Meda Bioretention Sand Meda Bioretention Sand Meda Bioretention Sand Meda Appendix C As Constructed Pond Volume Project: NEC Lake and Shields Basin Description: South Pond AB Contour Contour Depth Incremental Cumulative Incremental Cumulative Elevation Area (ft) Volume Volume Volume Volume (sq. ft) Avg. End Avg. End Conic Conic (cu. ft) (cu. ft) (cu. ft) (cu. ft) 5,024.200 32.61 N/A N/A 0.00 N/A 0.00 5,024.400 110.82 0.200 14.34 14.34 13.57 13.57 5,024.600 188.23 0.200 29.91 44.25 29.57 43.14 5,024.800 281.69 0.200 46.99 91.24 46.68 89.82 5,025.000 349.13 0.200 63.08 154.32 62.96 152.78 5,025.200 385.29 0.200 73.44 227.77 73.41 226.19 5,025.400 414.71 0.200 80.00 307.77 79.98 306.17 5,025.600 444.82 0.200 85.95 393.72 85.94 392.11 5,025.800 475.78 0.200 92.06 485.78 92.04 484.15 5,026.000 507.69 0.200 98.35 584.13 98.33 582.48 5,026.200 540.74 0.200 104.84 688.97 104.83 687.31 5,026.400 646.77 0.200 118.75 807.72 118.59 805.90 5,026.600 789.36 0.200 143.61 951.33 143.38 949.28 5,026.800 985.48 0.200 177.48 1128.82 177.12 1126.40 5,027.000 1,169.63 0.200 215.51 1344.33 215.25 1341.65 5,027.200 1,334.82 0.200 250.44 1594.77 250.26 1591.91 5,027.400 1,522.58 0.200 285.74 1880.51 285.53 1877.44 5,027.600 1,677.72 0.200 320.03 2200.54 319.90 2197.35 5,027.800 1,805.13 0.200 348.28 2548.83 348.21 2545.55 5,028.000 1,943.32 0.200 374.85 2923.67 374.76 2920.31 5,028.200 2,078.11 0.200 402.14 3325.82 402.07 3322.38 5,028.400 2,215.94 0.200 429.41 3755.22 429.33 3751.71 5,028.600 2,356.79 0.200 457.27 4212.49 457.20 4208.91 5,028.800 2,500.68 0.200 485.75 4698.24 485.68 4694.59 5,029.000 2,647.61 0.200 514.83 5213.07 514.76 5209.35 Project: NEC Lake and Shields Basin Description: North Pond-AB Contour Contour Depth Incremental Cumulative Incremental Cumulative Elevation Area (ft) Volume Volume Volume Volume (sq. ft) Avg. End Avg. End Conic Conic (cu. ft) (cu. ft) (cu. ft) (cu. ft) 5,026.800 0.53 N/A N/A 0.00 N/A 0.00 5,026.800 0.88 0.000 0.00 0.00 0.00 0.00 5,027.000 11.75 0.200 1.26 1.26 1.06 1.06 5,027.200 35.11 0.200 4.69 5.95 4.48 5.53 5,027.400 79.27 0.200 11.44 17.39 11.14 16.68 5,027.600 144.24 0.200 22.35 39.74 22.03 38.71 5,027.800 242.87 0.200 38.71 78.45 38.28 76.99 5,028.000 370.51 0.200 61.34 139.78 60.89 137.88 5,028.200 534.18 0.200 90.47 230.25 89.97 227.85 5,028.400 806.21 0.200 134.04 364.29 133.11 360.96 5,028.600 1,069.10 0.200 187.53 551.82 186.91 547.87 5,028.800 1,289.78 0.200 235.89 787.71 235.54 783.42 5,028.950 1,453.47 0.150 205.74 993.45 205.62 989.04 Appendix D Record Drawings CT V CT V CT V CTV CTV CTV CTV CTV CTV CTV CTV CTV CT V T CT V CT V CT V CT V T T T T SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS X X X X X X X X X X ELEC BRKRE VAULT ELEC F ES F ES F E S D E E E E E E E E E E E E E E E E E E E E E E E E E E XXXXXXXX X X X X X X X X X X X X X X X X X X X S S GAS GAS T CABLE D S HYD VAULT ELEC C VAULT ELEC VAULT ELEC ELEC VAULT ELEC TRAFFIC VAULT S VAULT F.O. VAULT F.O. VAULT ELEC T S S F.O. TRAFFIC VAULT M HY D S C VAULT ELEC W VAULT ELEC S G G G G G G W W W W W W W W W E E E WGGGGG GWW G G G G G G G G W E E E G G G G G E E EEEEEEEEE FO FO E E E E EE G G G G G G G G G W W W W W W W E E G G G G G W W W W W W W FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G W W W W W XXXX W W W G G G G G G G G G G CSCS CS CS CS T S CS VAULT CABLE C CS W W W W W W W W W W W W W W E ELEC VAULT ELEC CTELEC BRKR T CABLE C SS SS SS SS SS SS SSSS SS SS SS SS SSSSSS SS SS VAULT ELEC TRAFFIC VAULT CS //////////// ////////////// / / / / / / / / / / / / / / / / / / / / / / / / / / / // /// /// /// /// /// /// /// /// / / / / / / / / / / / / / / / / / / / / / / / / / / / //////////// SH I E L D S S T R E E T LAKE STREET JAMES COURT GLENWOOD COMMONS PO R T I O N O F B L O C K 1 CO L L E G E H E I G H T S RESUBDIVISION OF WOODS SUBDIVISION HIDAYAH VILLAGE CA R R I A G E H O U S E AP A R T M E N T S UN P L A T T E D UN P L A T T E D CAMPUS GARDENS ADDITION BLOCK 1 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 CAMPUS GARDENS ADDITION BLOCK 3 UN P L A T T E D UN P L A T T E D UN P L A T T E D BE N N E T T R O A D 51.84' 18" VERTICAL CURB AND GUTTER (TO BE REMOVED) 41.26' OF 2' CONCRETE PAN (TO BE REMOVED) 6.88' OF 2' CONCRETE PAN (TO BE REMOVED) 50.95' 30" VERTICAL CURB AND GUTTER (TO BE REMOVED) SAM MH RIM =5024.21 INV. IN = 5018.81 (N) INV. IN = 5018.80 (E) INV. OUT = 5018.74 (S) EXISTING 8" PVC SANITARY EXISTING 8" PVC SANITARY EXISTING STRM MH RIM = 5022.49 INV. IN = 5017.85 (S) INV. IN = 5017.79 (E) INV. OUT = 5017.72 (N) EXISTING STRM MH RIM = 5022.53 INV. IN = 5019.83 (W) INV. OUT = 5019.43 (N) EXISTING SAN MH RIM = 5022.80 INV. IN = 5018.10 (N) INV. IN = 5018.04 (E) INV. OUT = 5018.00 (SW) LEFT TURN SIGN MOTORCYCLE PARKING SIGN EXISTING OUTLET STRUCTURE FLOWLINE ELEV. = 5019.95 EXISTING FES FLOWLINE ELEV. = 5020.59 8" WIDE BLOCK WALL EXISTING FES FLOWLINE ELEV. = 5020.90 EXISTING FES FLOWLINE ELEV. = 5021.04 1' WIDE BLOCK WALL 16.20 L.F. 12" RCP @ 0.86% BLOCK WALL EXISTING 8" PVC SANITARY EXISTING 12" PVC SANITARY EXISTING 12" PVC SANITARY RIGHT TURN SLOW SIGN EXISTING SAN MH RIM = 5026.55 INV. IN = 5018.15 (N) INV. IN = 5017.65 (NE) INV. OUT = 5017.54 (S) EXISTING SAN MH RIM = 5031.09 INV. IN = 5016.64 (W) INV. IN = 5016.71 (N) INV. OUT = 5016.64 (E) "NO PARKING DURING STADIUM EVENTS" "2 HR PARKING MON.-FRI." SIGN EXISTING 10" PVC SANITARY EXISTING SAN MH RIM = 5034.35 INV. IN = 5017.65 (W) INV. OUT = 5017.60 (E) EXISTING 8" PVC SANITARY EXISTING SAN MH RIM = 5037.84 INV. IN = 5019.34 (N) INV. IN = 5019.27 (E) INV. OUT = 5019.16 (S) EXISTING 15" PVC SANITARY EXISTING SAN MH RIM = 5034.30 INV. IN = 5019.35 (N) INV. IN = 5020.40 (W) INV. OUT = 5019.30 (S) EXISTING OUTLET STRUCTURE FLOWLINE ELEV. = 5022.75 "PRIVATE PROPERTY" "NO PARKING VIOLATORS WILL BE TOWED" SIGN (TO BE REMOVED) "NO PARKING VIOLATORS WILL BE TOWED" SIGNS (2) (TO BE REMOVED) EXISTING 18" RCP STORM METAL STAKE (TO BE REMOVED TYP.) LIGHT POLE (TO BE REMOVED) EXISTING FENCE (TO BE REMOVED) ELECTRIC VAULT (TO BE RELOCATED) TELEPHONE PEDESTAL (TO BE RELOCATED) CABLE VAULT (TO BE RELOCATED) CURB STOP 45 L.F. WATER SERVICE (TO BE ABANDONED AT MAIN) CURB STOPS (2) (TO BE REMOVED) 44 L.F. WATER SERVICE (TO BE ABANDONED AT MAIN) 46 L.F. WATER SERVICE (TO BE ABANDONED AT MAIN) CURB STOP (TO BE REMOVED) EXISTING FIRE HYDRANT CABLE VAULT (TO BE RELOCATED) CABLE PEDESTAL (TO BE RELOCATED) EXISTING TRAFFIC SIGNAL (TO BE PROTECTED) EXISTING BUS STOP (TO BE MAINTAINED) 24 L.F. WATER SERVICE (TO BE ABANDONED AT MAIN)CURB STOP (TO BE REMOVED) EXISTING FENCE (TO BE REMOVED) MAILBOX (TO BE REMOVED)WATER METER (TO BE REMOVED) METAL STAKE (TO BE REMOVED TYP.) 145 SQ. FT. CONCRETE (TO BE REMOVED) SAW CUT 1035 SQ. FT. ASPHALT/CONCRETE (TO BE REMOVED) 2100 SQ. FT. ASPHALT (TO BE REMOVED) 1245 SQ. FT. ASPHALT (TO BE REMOVED) SAW CUT EXISTING 3' CONCRETE PAN SHRUBS (9) (TO BE REMOVED) TREES (2) (TO BE REMOVED) TREE (TO BE REMOVED) TREE (TO BE REMOVED) 21 L.F. WATER SERVICE (TO BE ABANDONED AT MAIN) CURB STOP (TO BE REMOVED) 20 L.F. WATER SERVICE (TO BE ABANDONED AT MAIN) CURB STOP (TO BE REMOVED) 90 L.F. FENCE (TO BE REMOVED) 230 SQ. FT. CONCRETE (TO BE REMOVED) TREES (3) (TO BE REMOVED) SHRUBS (2) (TO BE REMOVED) TREE (TO BE REMOVED) SAW CUT337 SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE EXISTING 18" VERTICAL CURB AND GUTTER (TO BE REMOVED AND REPLACE TO THE EXTENTS NEEDED FOR THE INSTALLATION OF THE PROPOSED STORM PIPE) EXISTING 8" WATER MAIN EXISTING 6" WATER MAIN EXISTING 6" WATER MAIN EXISTING 12" WATER MAIN EXISTING FENCE (TO BE REMOVED) 230± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE FOR GAS SERVICE) 70± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE) EXISTING ACCESS RAMP EXISTING ACCESS RAMP ROLL-OVER CURB/GUTTER & ATTACHED SIDEWALK (TO BE REMOVED (700± SQ. FT.)) DRIVE CUT, SIDEWALK & BIKE LANE TO BE REMOVED (350± SQ. FT.) DRIVE CUT, SIDEWALK & BIKE LANE TO BE REMOVED (250± SQ. FT.) DRIVE CUT, SIDEWALK & BIKE LANE TO BE REMOVED (200± SQ. FT.) 142' SIDEWALK (TO BE REMOVED) CABLE BOX (TO BE RELOCATED) 72± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE) 85± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE) 80± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE) 75± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE) EXISTING SWITCHING CABINET TO BE REPLACED WITH UNDERGROUND COMPOSITE VAULT SHRUB (TO BE REMOVED) EXISTING FIRE HYDRANT EXISTING 2' CONCRETE PAN EXISTING FENCE (TO BE REMOVED) EXISTING 18" VERTICAL CURB AND GUTTER (TO BE REMOVED AND REPLACE TO THE EXTENTS NEEDED FOR THE INSTALLATION OF WATER SERVICE, FIRE SERVICE, AND SANITARY SERVICE) 10.43' CURB AND GUTTER TO BE REPLACED IF DAMAGED DURING ABANDONMENT OF WATER SERVICE 10.01' CURB AND GUTTER TO BE REPLACED IF DAMAGED DURING ABANDONMENT OF WATER SERVICE 13.61' CURB AND GUTTER TO BE REPLACED IF DAMAGED DURING ABANDONMENT OF WATER SERVICE 95± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE) 3270± SQ. FT. ASPHALT (TO BE REMOVED AND REPLACE) CONCRETE PAD ABANDON SANITARY SERVICE PER FORT COLLINS STANDARDS 10' SANITARY SEWER EASEMENT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 138.85' STRIPING TO BE REMOVED (TO BE WATER BLASTED OR GRINDED DO NOT PAINT BLACK) ABANDON SANITARY SERVICES PER FORT COLLINS STANDARDS ABANDON SANITARY SERVICES (2) PER CITY OF FORT COLLINS STANDARDS AND PLUG EXISTING SANITARY MANHOLE ///////////////////////////////////// ///////////////////////////////////// ABANDON SANITARY SERVICES PER FORT COLLINS STANDARDS Sheet NE C L A K E & S H I E L D S E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 17 8/22/19 NORTH C1.00 & D E M O L T I O N P L A N EX I S T I N G C O N D I T I O N S 03 ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 HYD TRAFFIC VAULT G W ////////////////////////////// S G VAULT ELEC T W SS E PROJECT DATUM: NAVD 88 BENCHMARK #1: CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNALBASE. ELEVATION = 5025.74 BENCHMARK #2: CITY OF FORT COLLINS BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT RD. AND SHIELDS ST., ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL. ELEVATION = 5025.67 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17 BASIS OF BEARING: THE BASIS OF BEARINGS IS THE WEST LINE OF THE SOUTHWEST QUARTER OF SECTION 14 AS BEARING NORTH 00°29'45" EAST. 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 5.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 6.SEE LANDSCAPE PLANS FOR TREE MITIGATION MEASURES. 7.ALL EXISTING SANITARY SEWER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO BE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700). 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 9.DEMOLITION OF THE EXISTING BUILDING, PAVEMENTS, AND OTHER SITE FEATURES SHOULD INCLUDE COMPLETE REMOVAL OF ALL FOUNDATION SYSTEMS, BELOW-GRADE STRUCTURAL ELEMENTS, PAVEMENTS, AND EXTERIOR FLAT WORK WITHIN THE PROPOSED CONSTRUCTION AREA. THIS SHOULD INCLUDE REMOVAL OF ANY UTILITIES TO BE ABANDONED ALONG WITH ANY LOOSE UTILITY TRENCH BACKFILL OR LOOSE BACKFILL FOUND ADJACENT TO EXISTING FOUNDATIONS. 10.LIMITS OF CONCRETE CURB REMOVAL SHALL BE TO THE NEAREST JOINT. SECTIONS LESS THAN 5' SHALL BE COMPLETELY REPLACED. 11.CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, SIDEWALKS, FENCES, AND UTILITIES. 12.CONTRACTOR TO COORDINATE REMOVAL AT EXISTING WATER SERVICES WITH CITY OF FORT COLLINS UTILITIES FIELD OPERATIONS AT (970)416.2165. 13.ALL UNUSED WATER AND SEWER SERVICES TO BE ABANDONED AT THE MAIN PER CITY OF FORT COLLINS STANDARDS. CONTRACTOR TO IDENTIFY ALL UNUSED SERVICES AND COORDINATE WITH THE CITY OF FORT COLLINS FOR SERVICE ABANDONMENT. OHUOVERHEAD UTILITY BURIED ELECTRIC STORM LINE SANITARY SEWER LINE CONIF. TREE DECID. TREE TO BE REMOVED H2O METER TELEPHONE PEDESTAL ELECTRIC VAULT POWER POLE CONIF. TREE TO BE REMOVED DECID. TREE GAS METER DEMO LINE MINOR CONTOUR MAJOR CONTOUR EXISTING CURB/GUTTER WATER LINE BURIED GAS PROPERTY BOUNDARY TRAFFIC VAULT FIRE HYDRANT LIGHT POLE LEGEND: BENCHMARK AND BASIS OF BEARING NOTES: CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R EXISTING ROW EXISTING LOT LINE EXISTING EASEMENT 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1-JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.REFER TO LANDSCAPE AND IRRIGATION PLANS FOR ADDITIONAL TREE PROTECTION MEASURES. TREE PROTECTION NOTES: TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 1 MI N O R A M N E D M E N T - D R I V E A I S L E BR R 07 / 2 7 / 2 0 THE S E R E C O R D D R A W I N G S , P R O D U C E D B Y N O R T H E R N E N G I N E E R I N G SER V I C E S , I N C . , A R E B A S E D I N W H O L E , O R I N P A R T , U P O N I N F O R M A T I O N PRO V I D E D B Y O T H E R S . N O R T H E R N E N G I N E E R I N G S E R V I C E S , I N C . A S S U M E S NO L I A B I L I T Y F O R T H E A C C U R A C Y O R C O M P L E T E N E S S O F T H I S I N F O R M A T I O N . REC O R D D R A W I N G 05.11.20 RECORD INFO.ONLY(SEE NOTE) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /// /// /// /// /// /// /// /// // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ////////////// /////////////////////////////////////////// //////////// ///////////////////////////////////// WW WW FE S FE S F E S FE S TF G G G E E E E E E E VAULT SSSSSSSSSSSSSSS F F W F W W W FE S UD UD CT V CT V CT V CTV CTV CTV CTV CTV CTV CTV CTV CTV CT V T CT V CT V CT V CT V T T T T SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS X X X X X X X X X X ELEC BRKRE VAULT ELEC FE S F E S FE S D E E E E E E E E E E E E E E E E E E E E E E E E E E E XXXXXXXX X X X X X S S GAS GAS T CABLE D S HYD VAULT ELEC C VAULT ELEC VAULT ELEC ELEC VAULT ELEC TRAFFIC VAULT S VAULT F.O. VAULT F.O. VAULT ELEC T S S F.O. TRAFFIC VAULT HYD S C VAULT ELEC VAULT ELEC S G G G G G G W W W W W W W W W E E E WGGGGG G G G G G G G G G E E E G G G G G E E EEEEEEEEE FO FO E E E E EE G G G G G G G G G W W W W W W W E E G G G G G W W W W W W W FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G W W W W W XXXX W W W G G G G G G G G G G T S CS W W W W W W W W W W W W W W E ELEC CTELEC BRKR SS SS SS SS SS SS SS VAULT ELEC TRAFFIC VAULT CS EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT TRANSFORMER GAS SERVICE ELECTRICAL SERVICE EXISTING SAN MH RIM =5024.21 INV. IN = 5018.81 (N) INV. IN = 5018.80 (E) INV. OUT = 5018.74 (S) EXISTING 8" PVC SANITARY EXISTING FES FLOWLINE ELEV. = 5020.59 EXISTING FES FLOWLINE ELEV. = 5020.90 EXISTING FES FLOWLINE ELEV. = 5021.04 EXISTING 12" PVC SANITARY EXISTING SAN MH RIM = 5026.55 INV. IN = 5018.15 (N) INV. IN = 5017.65 (NE) INV. OUT = 5017.54 (S) EXISTING SAN MH RIM = 5031.09 INV. IN = 5016.64 (W) INV. IN = 5016.71 (N) INV. OUT = 5016.64 (E) EXISTING 10" PVC SANITARY EXISTING 8" PVC SANITARY EXISTING SAN MH INV. IN=5019.34 (N) INV. IN=5019.27 (E) INV. OUT=5019.16 (S) FG=5037.84 EXISTING 15" PVC SANITARY EXISTING SAN MH RIM = 5034.30 INV. IN = 5019.35 (N) INV. IN = 5020.40 (W) INV. OUT = 5019.30 (S) EXISTING OUTLET STRUCTURE FLOWLINE ELEV. = 5022.75 EXISTING 6" WATER MAIN EXISTING 6" WATER MAIN EXISTING 12" WATER MAIN DRAINAGE EASEMENT EXISTING 8" PVC SANITARY EXISTING 12" PVC SANITARY FD C 9' UTILITY EASEMENT EXISTING 12" RCP CULVERT 15' UTILITY EASEMENT 9' UTILITY EASEMENT FDC CONNECTION 1.5" WATER SERVICE 6" FIRE SERVICE STORM LINE A (SEE SHEET C3.01) STORM LINE B (SEE SHEET C3.01) STORM LINE D (SEE SHEET C3.02) STORM LINE C (SEE SHEET C3.02) 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT DRAINAGE EASEMENT DRAINAGE EASEMENT EXISTING ELECTRIC SWITCHING CABINET TO BE PLACED IN UNDERGROUND COMPOSITE VAULT SCOUR STOP (TYP.) INLET F3 INV.=5029.89 FG=5032.75 INLET F1 INV.=5028.48 FG=5031.89 INLET F2 INV.=5029.13 FG=5032.01 FES F FG=5028.20 62 . 9 3 L F 8 " H D P E @ 1 . 0 0 % 34 . 1 5 L F 8 " H D P E @ 1 . 0 0 % SH I E L D S S T R E E T LAKE STREET JAMES COURT GLENWOOD COMMONS PO R T I O N O F B L O C K 1 CO L L E G E H E I G H T S RESUBDIVISION OF WOODS SUBDIVISION HIDAYAH VILLAGE CA R R I A G E H O U S E AP A R T M E N T S UN P L A T T E D UN P L A T T E D CAMPUS GARDENS ADDITION BLOCK 1 LOT 1 LOT 1 LOT 2 LOT 3 LOT 4 CAMPUS GARDENS ADDITION BLOCK 3 UN P L A T T E D UN P L A T T E D UN P L A T T E D BE N N E T T R O A D LOT 1 LOT 2 24' EMERGENCY ACCESS EASEMENT PROPOSED 3' CONCRETE PAN PROPOSED SIDEWALK CULVERT PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN 24' EMERGENCY ACCESS EASEMENT PROPOSED 4' CONCRETE PAN EXISTING 18" RCP STORM EXISTING 2' CONCRETE PAN 24' EMERGENCY ACCESS EASEMENT 10' UTILITY EASEMENT 10' DRAINAGE EASEMENT EXST SAN MH INV. IN=5017.65 (W) INV. OUT=5017.60 (E) FG=5034.35 249.71 LF 4" PVC @ 3.00% 15 4 . 7 3 L F 8 " P V C @ 0 . 3 0 % SANITARY SERVICE TAP INV. IN=5018.28 (N) INV. IN=5018.28 (W) INV. OUT=5018.28 (S) FG=5025.10 SS CONNECTION INV. OUT=5025.77 (E) FG=5033.85 10' SANITARY SEWER EASEMENT 8"x6" TEE w/ 6" G.V. & T.B. (S) N:124740.53 E:189740.34 1" WATER SERVICE N:124740.42 E:189745.34 45° BEND N:124684.14 E:189724.74 1" METER UPSIZE SERVICE LINE TO 1.5" 5' AFTER THE METER PIT 22.5° BEND N:124718.36 E:189739.84 CURB STOP N:124739.70 E:189745.33 15' UTILITY EASEMENT 22.18 LF 6" PVC FIRE SERVICE N01°18'33"E 37.40 LF 6" PVC FIRE SERVICE N23°48'33"E 11.55 LF 6" PVC FIRE SERVICE N68°48'33"E 32.64 LF 6" PVC FIRE SERVICE S89°19'20"E 22.5° BEND N:124679.96 E:189713.97 EXISTING 8" WATER MAIN 20' UTILITY EASEMENT 96.89 LF 1" WATER SERVICE 13.95 LF 1.5" WATER SERVICE PROPOSED1' SIDEWALK CHASE RD CONNECTION 2-1 INV.=5030.44 FG=5033.34 RD CONNECTION 1-1 INV.=5030.43 FG=5033.78 RD PIPE END 2 INV.=5030.28 RD PIPE END 1 INV.=5030.27 32.06 LF 4" HDPE @ 0.50% 32.06 LF 4" HDPE @ 0.50% EXISTING LIGHT POLE TO REMAIN ///////////// ////////// 27.29 LF 8" HDPE @ 1.00% 41 . 5 6 L F 8 " H D P E @ 1 . 0 0 % DRAINAGE EASEMENT ////// Sheet NE C L A K E & S H I E L D S E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 17 8/22/19 C.300 UT I L I T Y P L A N 05 NORTH ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 LEGEND: GENERAL NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER AND SANITARY SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4.ALL WATER FITTINGS, VALVES, AND OTHER UTILITY APPURTENANCES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL EXISTING SANITARY SEWER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO BE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700). 6.ALL EXISTING WATER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO THE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700) 7.PRIOR TO ORDERING MATERIAL AND MOBILIZING, CONTRACTOR SHALL FIELD LOCATE AND VERIFY ELEVATIONS OF ALL CONCRETE AND ASPHALT TIE-INS, EXISTING SEWER MAINS, WATER MAINS, AND ALL OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS. SPECIAL ATTENTION SHALL BE PAID TO ALL PROPOSED UTILITY CROSSINGS. IT IS RECOMMENDED THAT THE CONTRACTOR POTHOLE SAID CROSSINGS PRIOR TO ORDERING MATERIAL. REFER TO GENERAL NOTE #9 ON SHEET C-001 IF A CONFLICT ARISES AND/OR A DESIGN MODIFICATION IS DESIRED. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 9.CONTRACTOR IS RESPONSIBLE FOR ALL THE REPAIRS AND REPLACEMENTS OF ANY DAMAGED CURB AND GUTTER. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 10.ALL PROPOSED FLARED END SECTIONS HAVE SCOUR STOP. SEE SHEET C5.01 FOR SIZING AND DETAIL. SEXISTING SANITARY MH GEXISTING GAS METER EEXISTING ELECTRIC METER VAULT ELECEXISTING ELECTRIC VAULT TEXISTING TELEPHONE PEDESTAL HY DEXISTING FIRE HYDRANT TRAFFIC VAULTEXISTING TRAFFIC VAULT EEXISTING BURIED ELECTRIC GEXISTING BURIED GAS WEXISTING WATER LINE SSEXISTING SANITARY SEWER LINE GPROPOSED GAS LINE PROPOSED WATER SERVICE LINE PROPOSED SANITARY SERVICE LINE EXISTING STORM SEWER PROJECT BOUNDARY FDC PROPOSED CURB & GUTTER PROPOSED FIRE DEPARTMENT CONNECTION PROPOSED FIRE SERVICE LINE ELECTRIC TRANSFORMER EPROPOSED ELECTRIC LINE UDPROPOSED PERFORATED STORM PROPOSED GAS METER PROPOSED STORM SEWER S DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST PROPOSED ELECTRIC METER PROPOSED INLET WATER METER CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R TF EXISTING ROW PROPOSED LOT LINE EASEMENT EXISTING LOT LINE PROPOSED ROW D 1 MI N O R A M N E D M E N T - D R I V E A I S L E BR R 07 / 2 7 / 2 0 05.11.20 RECORD INFO.ONLY(SEE NOTE) THE S E R E C O R D D R A W I N G S , P R O D U C E D B Y N O R T H E R N E N G I N E E R I N G SER V I C E S , I N C . , A R E B A S E D I N W H O L E , O R I N P A R T , U P O N I N F O R M A T I O N PRO V I D E D B Y O T H E R S . N O R T H E R N E N G I N E E R I N G S E R V I C E S , I N C . A S S U M E S NO L I A B I L I T Y F O R T H E A C C U R A C Y O R C O M P L E T E N E S S O F T H I S I N F O R M A T I O N . REC O R D D R A W I N G WW F E S FE S TF E E E E E E F E S UD UD SS SS SS SS SS SS X X X X X E E E E E E E E E E E E E E X X X X S GAS FES A STA 10+00.00 N: 124496.76 E: 190044.23 53.79 LF 15" HDPE @ 0.20% BASIN A1 STA 10+53.79 N: 124508.34 E: 189991.70 EXISTING 12" PVC SANITARY DRAINAGE EASEMENT LOT 2 PROPOSED 4' CONCRETE PAN EXISTING OUTLET STRUCTURE SCOUR STOP (TYP) 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 24' EMERGENCY ACCESS EASEMENT 10' SANITARY EASEMENT STA.=10+98.65 SANITARY CROSSING STORM LINE B (SEE THIS SHEET) EXISTING STORM LINE (SEE SHEET C3.00) PROPOSED 3' CONCRETE PAN PROPOSED SIDEWALK CULVERT 224.32 LF 15" HDP E @ 0 . 3 5 % PIPE END A2 STA 12+78.12 N: 124485.95 E: 189768.50 HEADWALL W/ ORIFICE PLATE RA I N G A R D E N M E D I A CR O S S - S E C T I O N A R E A WW W W F E S TF EEEEEEE FE S UD UD CT V CT V CT V CT V E E E G E E E E E 8.47 LF 12" HDPE @ 0.75% 99.61 LF 12" HDPE @ 0.75% 1" WATER SERVICE STORM LINE C (SEE SHEET C3.02) LOT 1 LOT 2 19.85 LF 12" HDPE @ 0.87% 24.01 LF 12" HDPE @ 0.75% 18.72 LF 12" HDPE @ 0.75% 4" SANITARY SERVICE FES B STA 10+00.00 N: 124490.25 E: 189708.52 90° BEND B2 STA 10+28.32 N: 124494.81 E: 189680.73 INLET B1 STA 10+19.85 N: 124494.81 E: 189689.20 24' EMERGENCY ACCESS EASEMENT 20' UTILITY EASEMENT PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN SCOUR STOP (TYP) 54.63 LF 12" HDPE @ 0.75% 23.95 LF 4" HDPE @ 0.50% INLET B3 STA 11+27.94 N: 124594.43 E: 189680.73 INLET B4 STA 12+06.58 N: 124594.43 E: 189602.08 RD CONNECTION B5 STA 12+25.30 N: 124613.14 E: 189602.08 TEE B3A STA 11+51.95 N: 124594.43 E: 189656.72 RD CONNECTION B3A-1 STA 11+51.95 N: 124618.37 E: 189656.72 15' UTILITY EASEMENT 6" FIRE SERVICE RAIN GARDEN MEDIA CROSS-SECTION AREA 5020 5025 5030 5035 5040 5045 5020 5025 5030 5035 5040 5045 9+7510+0011+0012+0013+0013+25 FE S A ST A 1 0 + 0 0 . 0 0 IN V . 5 0 2 3 . 2 8 ( W ) 224.32 LF 15" HDPE @ 0.35% 53.79 LF 15" HDPE @ 0.20% PI P E E N D A 2 ST A 1 2 + 7 8 . 1 2 IN V . 5 0 2 4 . 1 6 ( E ) BA S I N A 1 ST A 1 0 + 5 3 . 7 9 FL . E L 5 0 2 8 . 0 ± IN V . I N 5 0 2 3 . 3 9 ( W ) IN V . O U T 5 0 2 3 . 3 9 ( E ) EXISTING GROUND PROPOSED GROUND FE S A ST A 1 0 + 0 0 . 0 0 IN V . 5 0 2 3 . 2 8 ( W ) 5020 5025 5030 5035 5040 5045 5020 5025 5030 5035 5040 5045 9+7510+0011+0012+0012+75 IN L E T B 1 ST A 1 0 + 1 9 . 8 5 FL . E L 5 0 3 0 . 3 ± IN V . I N 5 0 2 7 . 6 7 ( W ) IN V . O U T 5 0 2 7 . 6 7 ( E ) 8.47 LF 12" HDPE @ 0.75% 99.61 LF 12" HDPE @ 0.75% IN L E T B 3 ST A 1 1 + 2 7 . 9 4 FL . E L 5 0 3 2 . 6 ± IN V . I N 5 0 2 8 . 4 8 ( W ) IN V . O U T 5 0 2 8 . 4 8 ( S ) 24.01 LF 12" HDPE @ 0.75% IN L E T B 4 ST A 1 2 + 0 6 . 5 8 FL . E L 5 0 3 1 . 7 ± IN V . I N 5 0 2 9 . 0 7 ( N ) IN V . O U T 5 0 2 9 . 0 7 ( E ) RD C O N N E C T I O N B 5 ST A 1 2 + 2 5 . 3 0 IN V . 5 0 2 9 . 2 1 FE S B ST A 1 0 + 0 0 . 0 0 IN V . 5 0 2 7 . 5 0 ( W ) 19.85 LF 12" HDPE @ 0.87% 18.72 LF 12" HDPE @ 0.75% EXISTING GROUND PROPOSED GROUND 90 ° B E N D B 2 ST A 1 0 + 2 8 . 3 2 IN V . 5 0 2 7 . 7 4 ( N ) IN V . 5 0 2 7 . 7 4 ( E ) TE E B 3 A ST A 1 1 + 5 1 . 9 5 IN V . 5 0 2 8 . 6 6 ( W ) IN V . 5 0 2 9 . 0 0 ( N ) IN V . 5 0 2 8 . 6 6 ( E ) 54.63 LF 12" HDPE @ 0.75% 10/20/20 RECORD INFO.ONLY(SEE NOTE) Sheet NE C L A K E & S H I E L D S E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 17 8/22/19 C3.01 PL A N & P R O F I L E ST O R M L I N E S A & B 06 NORTH STORM LINE A "PRIVATE STORM LINE" PROFILE SCALE: ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 LEGEND: INLET SCHEDULE: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER AND SANITARY SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4.ALL WATER FITTINGS, VALVES, AND OTHER UTILITY APPURTENANCES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL EXISTING SANITARY SEWER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO BE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700). 6.ALL EXISTING WATER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO THE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700) 7.PRIOR TO ORDERING MATERIAL AND MOBILIZING, CONTRACTOR SHALL FIELD LOCATE AND VERIFY ELEVATIONS OF ALL CONCRETE AND ASPHALT TIE-INS, EXISTING SEWER MAINS, WATER MAINS, AND ALL OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS. SPECIAL ATTENTION SHALL BE PAID TO ALL PROPOSED UTILITY CROSSINGS. IT IS RECOMMENDED THAT THE CONTRACTOR POTHOLE SAID CROSSINGS PRIOR TO ORDERING MATERIAL. REFER TO GENERAL NOTE #9 ON SHEET C-001 IF A CONFLICT ARISES AND/OR A DESIGN MODIFICATION IS DESIRED. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 9.CONTRACTOR IS RESPONSIBLE FOR ALL THE REPAIRS AND REPLACEMENTS OF ANY DAMAGED CURB AND GUTTER. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. SEXISTING SANITARY MH GEXISTING GAS METER EEXISTING ELECTRIC METER VAULT ELECEXISTING ELECTRIC VAULT TEXISTING TELEPHONE PEDESTAL HY DEXISTING FIRE HYDRANT TRAFFIC VAULTEXISTING TRAFFIC VAULT EEXISTING BURIED ELECTRIC GEXISTING BURIED GAS WEXISTING WATER LINE SSEXISTING SANITARY SEWER LINE GPROPOSED GAS LINE PROPOSED WATER SERVICE LINE PROPOSED SANITARY SERVICE LINE EXISTING STORM SEWER PROJECT BOUNDARY FDC PROPOSED CURB & GUTTER PROPOSED FIRE DEPARTMENT CONNECTION PROPOSED FIRE SERVICE LINE ELECTRIC TRANSFORMER EPROPOSED ELECTRIC LINE UDPROPOSED PERFORATED STORM PROPOSED GAS METER PROPOSED STORM SEWER D S DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST PROPOSED ELECTRIC METER PROPOSED INLET WATER METER TF EXISTING ROW PROPOSED LOT LINE EASEMENT EXISTING LOT LINE PROPOSED ROW GENERAL NOTES: INLET ID BASIN SIZE [IN.]GRATE STYLE B1 12 2' x 2' CURB B3 12 DOME B4 12 DOME F1 8 DOME F2 8 DOME F3 8 DOME PROFILE SCALE: STORM LINE B "PRIVATE STORM LINE" NORTH STORM LINE C (SEE SHEET C3.02) CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R 1 MI N O R A M N E D M E N T - D R I V E A I S L E BR R 07 / 2 7 / 2 0 SOLID THES E R E C O R D D R A W I N G S , P R O D U C E D B Y N O R T H E R N E N G I N E E R I N G SERV I C E S , I N C . , A R E B A S E D I N W H O L E , O R I N P A R T , U P O N I N F O R M A T I O N PROV I D E D B Y O T H E R S . N O R T H E R N E N G I N E E R I N G S E R V I C E S , I N C . A S S U M E S NO L I A B I L I T Y F O R T H E A C C U R A C Y O R C O M P L E T E N E S S O F T H I S I N F O R M A T I O N . RECO R D D R A W I N G WW F E S FE S TF E E E E E E F E S UD UD SS SS SS SS SS SS X X X X X E E E E E E E E E E E E E E X X X X S GAS FES A STA 10+00.00 N: 124496.76 E: 190044.23 53.79 LF 15" HDPE @ 0.20% BASIN A1 STA 10+53.79 N: 124508.34 E: 189991.70 EXISTING 12" PVC SANITARY DRAINAGE EASEMENT LOT 2 PROPOSED 4' CONCRETE PAN EXISTING OUTLET STRUCTURE SCOUR STOP (TYP) 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 24' EMERGENCY ACCESS EASEMENT 10' SANITARY EASEMENT STA.=10+98.65 SANITARY CROSSING STORM LINE B (SEE THIS SHEET) EXISTING STORM LINE (SEE SHEET C3.00) PROPOSED 3' CONCRETE PAN PROPOSED SIDEWALK CULVERT 224.32 LF 15" HDP E @ 0 . 3 5 % PIPE END A2 STA 12+78.12 N: 124485.95 E: 189768.50 HEADWALL W/ ORIFICE PLATE RA I N G A R D E N M E D I A CR O S S - S E C T I O N A R E A WW W W F E S TF EEEEEEE FE S UD UD CT V CT V CT V CT V E E E G E E E E E 8.47 LF 12" HDPE @ 0.75% 99.61 LF 12" HDPE @ 0.75% 1" WATER SERVICE STORM LINE C (SEE SHEET C3.02) LOT 1 LOT 2 19.85 LF 12" HDPE @ 0.87% 24.01 LF 12" HDPE @ 0.75% 18.72 LF 12" HDPE @ 0.75% 4" SANITARY SERVICE FES B STA 10+00.00 N: 124490.25 E: 189708.52 90° BEND B2 STA 10+28.32 N: 124494.81 E: 189680.73 INLET B1 STA 10+19.85 N: 124494.81 E: 189689.20 24' EMERGENCY ACCESS EASEMENT 20' UTILITY EASEMENT PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN SCOUR STOP (TYP) 54.63 LF 12" HDPE @ 0.75% 23.95 LF 4" HDPE @ 0.50% INLET B3 STA 11+27.94 N: 124594.43 E: 189680.73 INLET B4 STA 12+06.58 N: 124594.43 E: 189602.08 RD CONNECTION B5 STA 12+25.30 N: 124613.14 E: 189602.08 TEE B3A STA 11+51.95 N: 124594.43 E: 189656.72 RD CONNECTION B3A-1 STA 11+51.95 N: 124618.37 E: 189656.72 15' UTILITY EASEMENT 6" FIRE SERVICE RAIN GARDEN MEDIA CROSS-SECTION AREA 5020 5025 5030 5035 5040 5045 5020 5025 5030 5035 5040 5045 9+7510+0011+0012+0013+0013+25 FE S A ST A 1 0 + 0 0 . 0 0 IN V . 5 0 2 3 . 2 8 ( W ) 224.32 LF 15" HDPE @ 0.35% 53.79 LF 15" HDPE @ 0.20% PI P E E N D A 2 ST A 1 2 + 7 8 . 1 2 IN V . 5 0 2 4 . 1 6 ( E ) BA S I N A 1 ST A 1 0 + 5 3 . 7 9 FL . E L 5 0 2 8 . 0 ± IN V . I N 5 0 2 3 . 3 9 ( W ) IN V . O U T 5 0 2 3 . 3 9 ( E ) EXISTING GROUND PROPOSED GROUND FE S A ST A 1 0 + 0 0 . 0 0 IN V . 5 0 2 3 . 2 8 ( W ) 5020 5025 5030 5035 5040 5045 5020 5025 5030 5035 5040 5045 9+7510+0011+0012+0012+75 IN L E T B 1 ST A 1 0 + 1 9 . 8 5 FL . E L 5 0 3 0 . 3 ± IN V . I N 5 0 2 7 . 6 7 ( W ) IN V . O U T 5 0 2 7 . 6 7 ( E ) 8.47 LF 12" HDPE @ 0.75% 99.61 LF 12" HDPE @ 0.75% IN L E T B 3 ST A 1 1 + 2 7 . 9 4 FL . E L 5 0 3 2 . 6 ± IN V . I N 5 0 2 8 . 4 8 ( W ) IN V . O U T 5 0 2 8 . 4 8 ( S ) 24.01 LF 12" HDPE @ 0.75% IN L E T B 4 ST A 1 2 + 0 6 . 5 8 FL . E L 5 0 3 1 . 7 ± IN V . I N 5 0 2 9 . 0 7 ( N ) IN V . O U T 5 0 2 9 . 0 7 ( E ) RD C O N N E C T I O N B 5 ST A 1 2 + 2 5 . 3 0 IN V . 5 0 2 9 . 2 1 FE S B ST A 1 0 + 0 0 . 0 0 IN V . 5 0 2 7 . 5 0 ( W ) 19.85 LF 12" HDPE @ 0.87% 18.72 LF 12" HDPE @ 0.75% EXISTING GROUND PROPOSED GROUND 90 ° B E N D B 2 ST A 1 0 + 2 8 . 3 2 IN V . 5 0 2 7 . 7 4 ( N ) IN V . 5 0 2 7 . 7 4 ( E ) TE E B 3 A ST A 1 1 + 5 1 . 9 5 IN V . 5 0 2 8 . 6 6 ( W ) IN V . 5 0 2 9 . 0 0 ( N ) IN V . 5 0 2 8 . 6 6 ( E ) 54.63 LF 12" HDPE @ 0.75% 10/20/20 RECORD INFO.ONLY(SEE NOTE) Sheet NE C L A K E & S H I E L D S E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 17 8/22/19 C3.01 PL A N & P R O F I L E ST O R M L I N E S A & B 06 NORTH STORM LINE A "PRIVATE STORM LINE" PROFILE SCALE: ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 LEGEND: INLET SCHEDULE: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER AND SANITARY SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4.ALL WATER FITTINGS, VALVES, AND OTHER UTILITY APPURTENANCES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL EXISTING SANITARY SEWER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO BE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700). 6.ALL EXISTING WATER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO THE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700) 7.PRIOR TO ORDERING MATERIAL AND MOBILIZING, CONTRACTOR SHALL FIELD LOCATE AND VERIFY ELEVATIONS OF ALL CONCRETE AND ASPHALT TIE-INS, EXISTING SEWER MAINS, WATER MAINS, AND ALL OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS. SPECIAL ATTENTION SHALL BE PAID TO ALL PROPOSED UTILITY CROSSINGS. IT IS RECOMMENDED THAT THE CONTRACTOR POTHOLE SAID CROSSINGS PRIOR TO ORDERING MATERIAL. REFER TO GENERAL NOTE #9 ON SHEET C-001 IF A CONFLICT ARISES AND/OR A DESIGN MODIFICATION IS DESIRED. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 9.CONTRACTOR IS RESPONSIBLE FOR ALL THE REPAIRS AND REPLACEMENTS OF ANY DAMAGED CURB AND GUTTER. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. SEXISTING SANITARY MH GEXISTING GAS METER EEXISTING ELECTRIC METER VAULT ELECEXISTING ELECTRIC VAULT TEXISTING TELEPHONE PEDESTAL HY DEXISTING FIRE HYDRANT TRAFFIC VAULTEXISTING TRAFFIC VAULT EEXISTING BURIED ELECTRIC GEXISTING BURIED GAS WEXISTING WATER LINE SSEXISTING SANITARY SEWER LINE GPROPOSED GAS LINE PROPOSED WATER SERVICE LINE PROPOSED SANITARY SERVICE LINE EXISTING STORM SEWER PROJECT BOUNDARY FDC PROPOSED CURB & GUTTER PROPOSED FIRE DEPARTMENT CONNECTION PROPOSED FIRE SERVICE LINE ELECTRIC TRANSFORMER EPROPOSED ELECTRIC LINE UDPROPOSED PERFORATED STORM PROPOSED GAS METER PROPOSED STORM SEWER D S DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST PROPOSED ELECTRIC METER PROPOSED INLET WATER METER TF EXISTING ROW PROPOSED LOT LINE EASEMENT EXISTING LOT LINE PROPOSED ROW GENERAL NOTES: INLET ID BASIN SIZE [IN.]GRATE STYLE B1 12 2' x 2' CURB B3 12 DOME B4 12 DOME F1 8 DOME F2 8 DOME F3 8 DOME PROFILE SCALE: STORM LINE B "PRIVATE STORM LINE" NORTH STORM LINE C (SEE SHEET C3.02) CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R 1 MI N O R A M N E D M E N T - D R I V E A I S L E BR R 07 / 2 7 / 2 0 SOLID THES E R E C O R D D R A W I N G S , P R O D U C E D B Y N O R T H E R N E N G I N E E R I N G SERV I C E S , I N C . , A R E B A S E D I N W H O L E , O R I N P A R T , U P O N I N F O R M A T I O N PROV I D E D B Y O T H E R S . N O R T H E R N E N G I N E E R I N G S E R V I C E S , I N C . A S S U M E S NO L I A B I L I T Y F O R T H E A C C U R A C Y O R C O M P L E T E N E S S O F T H I S I N F O R M A T I O N . RECO R D D R A W I N G VERIFIED VERIFIED VERIFIED VERIFIED VERIFIED MODIFIED IN THEDESIGN PROCESS 2 WW WW F E S F E S FE S TF GGGGG EEEEEEEEEEE VA U L T F E S F X X C X X X X X X VA U L T EL E C TR A F F I C VA U L T CS RAIN GARDEN MEDIA CROSS-SECTION AREA SOUTH POND NORTH POND 4: 1 5:1 3.5% 4:1 4:1 2.0% 2.0% 1. 9 % 2. 0 % 1.1% 2. 0 % 0.3% SCOURSTOP (TYP.) SCOURSTOP 5:1 4: 1 1.7% 1. 9 % 1. 9 % 2. 2 % 1.8% 0. 5 % 2.0% 5.2% 2. 0 % GL E N W O O D CO M M O N S CARRIAGE HOUSE APARTMENTS UNPLATTED UNPLATTED CA M P U S G A R D E N S AD D I T I O N BL O C K 1 UNPLATTED UNPLATTED UNPLATTED (1.3% ) (3.1% ) 2.5%(2 . 8 % ) 4.8%4.2% DRAINAGE EASEMENT 9' U T I L I T Y E A S E M E N T STORM LINE C (SEE SHEET C3.02) LOT 1 24 ' E M E R G E N C Y A C C E S S EA S E M E N T 24' EMERGENCY ACCESS EASEMENT SHIELDS STREET LA K E S T R E E T JA M E S C O U R T BENNETT ROAD EXISTING SIDEWALK CHASE EXISTING ACCESS RAMP W/ TRUNCATED DOMES PIPE END W/ HEADWALL TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK EXISTING ACCESS RAMP W/ TRUNCATED DOMES DR A I N A G E E A S E M E N T STORM LINE A (SEE SHEET C3.01) STORM LINE B (SEE SHEET C3.01) STORM LINE D (SEE SHEET C3.02) PROPOSED 3' CONCRETE PAN PROPOSED SIDEWALK CULVERT PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN STORM LINE F (SEE SHEET C3.00) SCOUR STOP SCOURSTOP 1-6" STAIR w/ 12" TREAD 9' U T I L I T Y E A S E M E N T EXISTING 3' CONCRETE PAN (2. 2 % ) (7.9% ) (5 . 9 % ) 2.0% EXISTING CURB & GUTTER 1. 9 % 5.0% LANDSCAPE RETAINING WALL (SEE LANDSCAPE PLANS) LANDSCAPE WALL (SEE LANDSCAPE PLANS) 2. 0 % 2.0%2.0%2.0%2.0% 1. 5 % 1. 5 % 2. 0 % 2. 0 % 1.1% 0.5 % 0.6 % (1 . 1 % ) 2. 0 % 1.1% 1.0% 1.2% MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER BIKE RAMP (SEE DETAIL 407) MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER 1.6% 2.0% 1.3% 0.9%1.2% 1.1% 1.0% 1.1% 1.1% 1.4%1.4%1.6% 8' SIDEWALK 6' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 7' S I D E W A L K 2. 0 % 3.5% 14.9% 5.4% 9.6% 14.7% 13.9% ACCESS EASEMENT TIE TO EXISTING 20' UTILITY EASEMENT LANDSCAPE WALL (SEE LANDSCAPE PLANS) 2. 0 % 5.3% 4: 1 15' UTILITY EASEMENT MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER 4. 0 % 8.0% 2. 0 % MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER 1.7% 3.0% 0. 9 % 2. 0 % 4.5 % 2.5 % 2.9% 3.1% 4: 1 4: 1 2.0% 2. 0 % EXISTING ELECTRIC SWITCHING CABINET TO BE PLACED IN UNDERGROUND COMPOSITE VAULT 2. 0 % 0.5 % 1.1% 4.4 % 1.6% PROPOSED 1' SIDEWALK CHASE PROPOSED THICKENED CONCRETE EDGE ARTIFICIAL TURF PLAYGROUND AREA SCOURSTOP RUBBERIZED PLAYGROUND AREA 2.6% RUBBERIZED PLAYGROUND AREA 1. 7 % 5.0%2.0% 2.0% PROPOSED 1' SIDEWALK CHASE PROPOSED RAMP 8.3% 2. 0 % FFE=33.85 34.1 4 32.4 6 32.22 31. 3 9 31.3 2 31.2 7 30.8 1 32.3 3 32.5 3 31. 7 9 30.80 (36 . 6 0 ) 36. 3 2 34.85 34.3 8 33.7 5 33.2 3 33.09 34.6 9 35.9 1 35.82 (35 . 4 9 ) (35.4 1 ) 32.5 1 32 . 1 8 (32 . 0 6 ) (3 1 . 5 9 ) (36 . 7 0 ) (32.0 9 ) (30.05) (27.1 6 ) (26 . 9 1 ) 32.11 32.11 27.61 27 . 6 8 27.6 1 30.5 7 (29.8 9 ) (3 1 . 2 2 ) (31.3 1 ) 32.01 (30.41) (31.74) (31 . 5 0 ) 32.7 2 30. 9 7 33 . 1 9 33.73 33.85 33 . 7 9 33 . 8 5 33 . 8 5 33.3 5 33 . 3 5 33.85 28. 2 0 30.7 0 30.7 0 28.8 0 29.2 6 26. 7 5 29.74 30.70 33 . 3 5 33.62 33. 8 5 33.85 33.19 33.1 9 33.6633. 8 5 33.8 5 33 . 8 5 33.85 33.39 33 . 8 5 33.8 5 32.35 27. 4 8 27.09 25.1 2 24.2 0 27.5 0 27.5 0 29.7 0 27.50 27.5 0 32.6 3 (35 . 3 3 ) (3 4 . 9 1 ) (34 . 5 1 ) (34 . 2 4 ) (33 . 8 2 ) (33 . 6 0 ) (32 . 8 3 ) 33.64 33.6 4 34. 3 5 35.1 0 34 . 7 5 35.2 8 35. 7 9 35.63 34.9 1 (30 . 3 5 ) 30.41 30. 2 4 33.98 32 . 0 8 26.9 2 32.91 32.7 532.97 (34.00)(34.00)(34.00) 32.88 31 . 8 9 32.5 7 32.6 7 33.15 33.25 33.77 32.0 1 33.1 7 33.0 7 31.7 8 32.09 32.12 32.22 30.95 (30 . 9 2 ) 31.36 32.40 32.28 31.72 32.13 33.09 33.42 33.16 33.12 33.28 31.42 30.75 32.3 2 32.59 32.5 5 33.92 33.66 33.58 32.9 0 32.6 3 (33.49) (34.85) 32.1 0 32.6 1 33 . 0 5 32.7 5 32.8 7 33.1 4 33. 7 2 33.6 0 31.7 3 33.6 2 32.67 32. 5 0 30.2 6 32. 8 6 32.78 32.45 30.28 34.18 32 . 6 4 32.21 32.17 31.0 7 30.99 31.03 31 . 1 931.5 0 31.4 5 31.4 1 31.3 9 30.3530.76 30 . 7 4 30.7 7 31.1 9 31. 0 6 31 . 1 1 32.95 32 . 6 0 32.30 31.9431.44 32.01 (36.03)(3 5 . 5 5 ) (3 5 . 0 6 ) 35 . 1 9 (35.4 1 ) (34 . 8 2 ) (34 . 8 1 ) (3 4 . 9 2 ) (3 4 . 8 8 ) 34.93 (35.54 ) (36.1 6 ) 30.5 5 28 . 8 0 29.43 29 . 2 6 30.7 0 33 . 7 7 32.62 32.59 33.6 4 33.0 5 33.5 1 33.4 8 33.2 3 32.6 0 33.05 32. 0 1 32.6 9 31.99 33.3 0 32.60 35 . 2 8 (3 5 . 1 5 ) (3 5 . 8 3 ) 34.8 5 32 . 4 6 (21 . 3 8 ) 31.93 32.3 0 32 . 3 0 32.2 1 32.2 3 32 . 3 5 32.1 9 32.3 1 26 . 5 4 27 . 9 5 27.95 27. 4 5 28. 1 3 29.69 30. 3 5 27.5 0 29.00 29.0 0 30.21 31.1 2 31.5 6 31.9 5 30.4 7 31. 4 7 30.7 3 (31.09) 30. 3 5 30.33 31. 0 4 30.28 31. 8 7 32 . 1 1 27.50 30.10 31 . 7 5 32 . 1 6 31. 9 4 31. 8 4 30. 8 3 30 . 9 8 30 . 7 9 30.8 1 32.2 2 31.7 4 31 . 0 0 30. 9 4 33.3733.78 33.77 33.11 32. 5 6 30.28 30.28 33.7 2 33.5 5 33.85 33.78 32.85 32.85 33.15 33.14 33.21 32 . 6 9 32 . 6 6 32.97 33.18 33 . 6 8 32 . 7 2 32 . 8 5 32.99 33 . 1 3 33 . 0 7 33.25 33 . 3 0 32.53 32.83 33 . 8 3 33.7532.32 32 . 4 0 32.2 9 32.25 33.7833.78 26.37 29.00 29.00 29.00 (36.0 1 ) 10/20/20 RECORD INFO.ONLY(SEE NOTE) Sheet NE C L A K E & S H I E L D S E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 17 8/22/19 C4.01 DE T A I L E D G R A D I N G P L A N 09 NORTH ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R LEGEND: EXISTING DECID. TREE EXISTING CONIF. TREE EXISTING LIGHT POLE PROJECT BOUNDARY EXISTING CURB/GUTTER FLOWLINE 50 4:1BANK SLOPE PROPOSED ASPHALT CROSS SLOPE CONCENTRATED FLOW DIRECTION PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR 79.45PROPOSED FINISH GROUND ELEVATION (79.45)EXISTING GROUND ELEVATION PROPOSED INFLOW CURB/GUTTER FLOWLINE 2.0% NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 3.EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4.REFER TO SITE PLAN, LANDSCAPE PLAN, AND PLAT FOR ADDITIONAL INFORMATION. 5.THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 6.SEE SHEET C2.00 FOR HORIZONTAL INFORMATION INCLUDING CURB AND GUTTER TYPES, PAN WIDTHS, DRIVE AISLE DIMENSIONS, EASEMENTS, ETC. EXISTING STORM SEWER LINE PROPOSED OUTFALL CURB/GUTTER FLOWLINE EXISTING ROW PROPOSED ROW EXISTING LOT LINE PROPOSED LOT LINE EASEMENT 1 MI N O R A M N E D M E N T - D R I V E A I S L E BR R 07 / 2 7 / 2 0 1 CONCRETE DETAILS THICKENED EDGE THES E R E C O R D D R A W I N G S , P R O D U C E D B Y N O R T H E R N E N G I N E E R I N G SERV I C E S , I N C . , A R E B A S E D I N W H O L E , O R I N P A R T , U P O N I N F O R M A T I O N PROV I D E D B Y O T H E R S . N O R T H E R N E N G I N E E R I N G S E R V I C E S , I N C . A S S U M E S NO L I A B I L I T Y F O R T H E A C C U R A C Y O R C O M P L E T E N E S S O F T H I S I N F O R M A T I O N . RECO R D D R A W I N G F E S F E S F E S D S S D S HYD SS F.O. HYD S S CS CS NYLOP L A S T DO NO T P O L L U T E DRAIN S T O WATERW A Y S DO NOT PO L L U T E D R A I N S T O W A T E R W A Y S NYLOPL A S T D U C T I L E I R O N MONITORING WELL TRAFFIC RATED MONITORING WELL TRAFFIC RATED GRADING & UTILITY AS-BUILTS GCH CONSTRUCTION SUNSHINE HOUSE -FC#213 MAJESTIC SURVEYING, LLC 1111 DIAMOND VALLEY DR. STE 104, WINDSOR, CO, 80550 PROJECT NO: 2019293 DATE: 8/26/2020 DRAWN BY: SAS NAME: SUNSHINE HOUSE FILE NAME: 2019293ASB.DWG CLIENT: GCH CONSTRUCITON CHECKED BY: MK, JR SCALE: 1" = 30' 1 SHEET 1 OF 1 REVISIONS:DATE:BASIS OF BEARINGS: THE BASIS OF BEARINGS IS THE WEST LINE OF THE SOUTHWEST QUARTER OF SECTION 14 AS BEARING NORTH 00°29'45" EAST BENCHMARK: BENCHMARK #1: CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNAL BASE. ELEVATION = 5025.74NAVD88 BENCHMARK #2: CITY OF FORT COLLINS BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT RD. AND SHIELDS ST., ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL. ELEVATION = 5025.67 NAVD88 LEGEND UPDATED PER 9-8-2020 FIELD WORK 9-14-20 UPDATED PER 10-8-2020 FIELD WORK 10-08-20 Appendix E State Portal Documents August 23, 2019 City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 RE: Final Drainage Report for NEC Lake and Shields Dear Staff: Northern Engineering is pleased to submit this Final Drainage Report for your review. This report accompanies the Final Development Review submittal for the proposed NEC Lake and Shields. This report has been prepared in accordance to the Fort Collins Stormwater Criteria Manual (FCSCM), and serves to document the stormwater impacts associated with the proposed The NEC Lake and Shields project. We understand that review by the City is to assure general compliance with standardized criteria contained in the FCSCM. If you should have any questions as you review this report, please feel free to contact us. Sincerely, NORTHERN ENGINEERING SERVICES, INC. Reviewed by: Blaine Mathisen, EI Benjamin Ruch, PE Project Engineer Project Engineer 8-22-19 SH I E L D S S T CEN T R E A V E . PROSPECT RD. W LAKE ST EA S T D R UNIVERSITY AVE HE A T H E R I D G E R D BENNETT RD SH I R E C T WESTWARD DR SPRINGFIELD DR W PITKIN ST W STUART ST BA Y R D SOUTH DR UNIVERSITY AVE JOHNSON DR LY N N W O O D D R BAY DRHOBBIT S W H I T C O M B S T SHEELY DR W PITKIN ST JUNIPER LN JAMES CT EL L I S D R ST S. C O L L E G E A V E . E. LAUREL ST 6' ESM'T. TURN 11.5' UTIL. 9' WALK 7.5' PKWY 9.5' WALK 10.5' TURN 5' BIKE 18' TURN 45' ROADWAY 68' ROW 54.5' EXISTING LAKE STREET 22.5' PROPOSED 5' BIKE 11.5' TRAVEL 6.5' WALK 10' TWIDDLE 11.5' TRAVEL 11.5' TRAVEL 10.5' TRAVEL 5' BIKE 6.5' WALK 65' ROADWAY 86' ROW VARIES PKWY 8' WALK ESM'T. UTIL. 15' 77' EXISTING 24' PROPOSED SHIELDS STREET 5.5' WALK 37' ROADWAY 18.5' LANE 18.5' LANE 6' PKWY 5' WALK ESM'T. UTIL. 9' 49.5' ROW JAMES COURT 42.5' EXISTING 20' PROPOSED VARIES ACCESS ESM'T Sheet NE C L A K E & S H I E L D S E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 17 8/22/19 C0.00 CO V E R S H E E T 01 SHEET INDEX C0.00 COVER SHEET C0.01 GENERAL & CONSTRUCTION NOTES C1.00 EXISTING CONDITIONS & DEMOLITION PLAN C2.00 HORIZONTAL CONTROL PLAN C3.00 UTILITY PLAN C3.01 STORM LINES A & B PLAN & PROFILE C3.02 STORM LINES C, C1, & D PLAN & PROFILE C4.00 OVERALL GRADING PLAN C4.01 DETAILED GRADING PLAN C5.00 EROSION CONTROL PLAN C5.01 EROSION CONTROL DETAILS C6.00 - C6.04 CONSTRUCTION DETAILS C7.00 DRAINAGE EXHIBIT CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R AUGUST 2019 CONTACT INFORMATION PROJECT TEAM: Northern Engineering Services, Inc. Andy Reese 301 North Howes Street, Suite 100 Fort Collins, CO 80524 (970) 221-4158 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: VICINITY MAP LANDSCAPE ARCHITECT CIVIL ENGINEER PROJECT DATUM: NAVD 88 BENCHMARK #1: CITY OF FORT COLLINS BENCHMARK 19-97 AT THE SOUTHEAST CORNER OF WEST ELIZABETH AND SHIELDS ST., ON A CONCRETE TRAFFIC SIGNALBASE. ELEVATION = 5025.74 BENCHMARK #2: CITY OF FORT COLLINS BENCHMARK 29-92 APPROXIMATE 300 FEET SOUTH OF WEST PROSPECT RD. AND SHIELDS ST., ON THE NORTH END OF THE WEST BRIDGE PARAPET WALL. ELEVATION = 5025.67 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17 BASIS OF BEARING: THE BASIS OF BEARINGS IS THE WEST LINE OF THE SOUTHWEST QUARTER OF SECTION 14 AS BEARING NORTH 00°29'45" EAST. ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: OWNER/APPLICANT GAS-----------------Xcel Energy-----------------------------Stephanie Rich (970) 225-7828 ELECTRIC--------City of Fort Collins Light & Power-- Rob Irish (970) 224-6167 CABLE-------------Xfinity--------------------------------------Don Kapperman (970) 567-0245 TELECOM.--------Centurylink-------------------------------Robert Rulli (970) 490-7503 WATER------------City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 WASTEWATER-City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 STORMWATER-City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER ** The underground utility locates are based upon the best available information at the time of locating. Contractor acknowledges that it is common for underground facility owner maps to have errors and omissions of data shown. Consequently, it is the Contractor's sole responsibility to field verify the location of all utilities prior to construction, and notify the Engineer of any discrepancies found. Cathy Mathis, APA TB Group 444 Mountain Avenue Berthoud, Colorado 80513 (970) 532-5891 CSURF Michael 'Bo' Brown LEED A.P. 2537 Research Blvd., Suite 200 Fort Collins, CO 80526 (970) 491-2625 ORIGINAL FIELD SURVEY NORTHERN ENGINEERING SERVICES, INC. PROJECT NUMBER: 232-047 DATE: JULY 13, 2018 FINAL UTILITY PLANS FOR NEC LAKE & SHIELDS A TRACT OF LAND LOCATED IN THE SOUTHWEST QUARTER OF SECTION 14, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, CO 80524 (970) 221-4158 SURVEYOR E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N PROJECT LOCATION TRAFFIC ENGINEER Delich Associates Matt Delich, PE 2272 Glen Haven Drive Loveland, CO 80538-4903 (970) 669-2061 8/22/19 1 1 MI N O R A M N E D M E N T - D R I V E A I S L E BR R 05 / 2 1 / 2 0 1 WW WW F E S F E S FE S TF GGGGG EEEEEEEEEEE VA U L T F E S F X X C X X X X X X VA U L T EL E C TR A F F I C VA U L T CS RAIN GARDEN MEDIA CROSS-SECTION AREA SOUTH POND NORTH POND 4: 1 5:1 3.5% 4:1 4:1 2.0% 2.0% 1. 9 % 2. 0 % 1.1% 2. 0 % 0.3% SCOURSTOP (TYP.) SCOURSTOP 5:1 4: 1 1.7% 1. 9 % 1. 9 % 2. 2 % 1.8% 0. 5 % 2.0% 5.2% 2. 0 % GL E N W O O D CO M M O N S CARRIAGE HOUSE APARTMENTS UNPLATTED UNPLATTED CA M P U S G A R D E N S AD D I T I O N BL O C K 1 UNPLATTED UNPLATTED UNPLATTED (1.3% ) (3.1% ) 2.5%(2 . 8 % ) 4.8%4.2% DRAINAGE EASEMENT 9' U T I L I T Y E A S E M E N T STORM LINE C (SEE SHEET C3.02) LOT 1 24 ' E M E R G E N C Y A C C E S S EA S E M E N T 24' EMERGENCY ACCESS EASEMENT SHIELDS STREET LA K E S T R E E T JA M E S C O U R T BENNETT ROAD EXISTING SIDEWALK CHASE EXISTING ACCESS RAMP W/ TRUNCATED DOMES PIPE END W/ HEADWALL TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK TIE TO EXISTING SIDEWALK EXISTING ACCESS RAMP W/ TRUNCATED DOMES DR A I N A G E E A S E M E N T STORM LINE A (SEE SHEET C3.01) STORM LINE B (SEE SHEET C3.01) STORM LINE D (SEE SHEET C3.02) PROPOSED 3' CONCRETE PAN PROPOSED SIDEWALK CULVERT PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN STORM LINE F (SEE SHEET C3.00) SCOUR STOP SCOURSTOP 1-6" STAIR w/ 12" TREAD 9' U T I L I T Y E A S E M E N T EXISTING 3' CONCRETE PAN (2. 2 % ) (7.9% ) (5 . 9 % ) 2.0% EXISTING CURB & GUTTER 1. 9 % 5.0% LANDSCAPE RETAINING WALL (SEE LANDSCAPE PLANS) LANDSCAPE WALL (SEE LANDSCAPE PLANS) 2. 0 % 2.0%2.0%2.0%2.0% 1. 5 % 1. 5 % 2. 0 % 2. 0 % 1.1% 0.5 % 0.6 % (1 . 1 % ) 2. 0 % 1.1% 1.0% 1.2% MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER BIKE RAMP (SEE DETAIL 407) MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER 1.6% 2.0% 1.3% 0.9%1.2% 1.1% 1.0% 1.1% 1.1% 1.4%1.4%1.6% 8' SIDEWALK 6' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 7' S I D E W A L K 2. 0 % 3.5% 14.9% 5.4% 9.6% 14.7% 13.9% ACCESS EASEMENT TIE TO EXISTING 20' UTILITY EASEMENT LANDSCAPE WALL (SEE LANDSCAPE PLANS) 2. 0 % 5.3% 4: 1 15' UTILITY EASEMENT MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER 4. 0 % 8.0% 2. 0 % MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER MATCH EXISTING CURB & GUTTER 1.7% 3.0% 0. 9 % 2. 0 % 4.5 % 2.5 % 2.9% 3.1% 4: 1 4: 1 2.0% 2. 0 % EXISTING ELECTRIC SWITCHING CABINET TO BE PLACED IN UNDERGROUND COMPOSITE VAULT 2. 0 % 0.5 % 1.1% 4.4 % 1.6% PROPOSED 1' SIDEWALK CHASE PROPOSED THICKENED CONCRETE EDGE ARTIFICIAL TURF PLAYGROUND AREA SCOURSTOP RUBBERIZED PLAYGROUND AREA 2.6% RUBBERIZED PLAYGROUND AREA 1. 7 % 5.0%2.0% 2.0% PROPOSED 1' SIDEWALK CHASE PROPOSED RAMP 8.3% 2. 0 % FFE=33.85 34.1 4 32.4 6 32.22 31. 3 9 31.3 2 31.2 7 30.8 1 32.3 3 32.5 3 31. 7 9 30.80 (36 . 6 0 ) 36. 3 2 34.85 34.3 8 33.7 5 33.2 3 33.09 34.6 9 35.9 1 35.82 (35 . 4 9 ) (35.4 1 ) 32.5 1 32 . 1 8 (32 . 0 6 ) (3 1 . 5 9 ) (36 . 7 0 ) (32.0 9 ) (30.05) (27.1 6 ) (26 . 9 1 ) 32.11 32.11 27.61 27 . 6 8 27.6 1 30.5 7 (29.8 9 ) (3 1 . 2 2 ) (31.3 1 ) 32.01 (30.41) (31.74) (31 . 5 0 ) 32.7 2 30. 9 7 33 . 1 9 33.73 33.85 33 . 7 9 33 . 8 5 33 . 8 5 33.3 5 33 . 3 5 33.85 28. 2 0 30.7 0 30.7 0 28.8 0 29.2 6 26. 7 5 29.74 30.70 33 . 3 5 33.62 33. 8 5 33.85 33.19 33.1 9 33.6633. 8 5 33.8 5 33 . 8 5 33.85 33.39 33 . 8 5 33.8 5 32.35 27. 4 8 27.09 25.1 2 24.2 0 27.5 0 27.5 0 29.7 0 27.50 27.5 0 32.6 3 (35 . 3 3 ) (3 4 . 9 1 ) (34 . 5 1 ) (34 . 2 4 ) (33 . 8 2 ) (33 . 6 0 ) (32 . 8 3 ) 33.64 33.6 4 34. 3 5 35.1 0 34 . 7 5 35.2 8 35. 7 9 35.63 34.9 1 (30 . 3 5 ) 30.41 30. 2 4 33.98 32 . 0 8 26.9 2 32.91 32.7 532.97 (34.00)(34.00)(34.00) 32.88 31 . 8 9 32.5 7 32.6 7 33.15 33.25 33.77 32.0 1 33.1 7 33.0 7 31.7 8 32.09 32.12 32.22 30.95 (30 . 9 2 ) 31.36 32.40 32.28 31.72 32.13 33.09 33.42 33.16 33.12 33.28 31.42 30.75 32.3 2 32.59 32.5 5 33.92 33.66 33.58 32.9 0 32.6 3 (33.49) (34.85) 32.1 0 32.6 1 33 . 0 5 32.7 5 32.8 7 33.1 4 33. 7 2 33.6 0 31.7 3 33.6 2 32.67 32. 5 0 30.2 6 32. 8 6 32.78 32.45 30.28 34.18 32 . 6 4 32.21 32.17 31.0 7 30.99 31.03 31 . 1 931.5 0 31.4 5 31.4 1 31.3 9 30.3530.76 30 . 7 4 30.7 7 31.1 9 31. 0 6 31 . 1 1 32.95 32 . 6 0 32.30 31.9431.44 32.01 (36.03)(3 5 . 5 5 ) (3 5 . 0 6 ) 35 . 1 9 (35.4 1 ) (34 . 8 2 ) (34 . 8 1 ) (3 4 . 9 2 ) (3 4 . 8 8 ) 34.93 (35.54 ) (36.1 6 ) 30.5 5 28 . 8 0 29.43 29 . 2 6 30.7 0 33 . 7 7 32.62 32.59 33.6 4 33.0 5 33.5 1 33.4 8 33.2 3 32.6 0 33.05 32. 0 1 32.6 9 31.99 33.3 0 32.60 35 . 2 8 (3 5 . 1 5 ) (3 5 . 8 3 ) 34.8 5 32 . 4 6 (21 . 3 8 ) 31.93 32.3 0 32 . 3 0 32.2 1 32.2 3 32 . 3 5 32.1 9 32.3 1 26 . 5 4 27 . 9 5 27.95 27. 4 5 28. 1 3 29.69 30. 3 5 27.5 0 29.00 29.0 0 30.21 31.1 2 31.5 6 31.9 5 30.4 7 31. 4 7 30.7 3 (31.09) 30. 3 5 30.33 31. 0 4 30.28 31. 8 7 32 . 1 1 27.50 30.10 31 . 7 5 32 . 1 6 31. 9 4 31. 8 4 30. 8 3 30 . 9 8 30 . 7 9 30.8 1 32.2 2 31.7 4 31 . 0 0 30. 9 4 33.3733.78 33.77 33.11 32. 5 6 30.28 30.28 33.7 2 33.5 5 33.85 33.78 32.85 32.85 33.15 33.14 33.21 32 . 6 9 32 . 6 6 32.97 33.18 33 . 6 8 32 . 7 2 32 . 8 5 32.99 33 . 1 3 33 . 0 7 33.25 33 . 3 0 32.53 32.83 33 . 8 3 33.7532.32 32 . 4 0 32.2 9 32.25 33.7833.78 26.37 29.00 29.00 29.00 (36.0 1 ) 10/20/20 RECORD INFO.ONLY(SEE NOTE) Sheet NE C L A K E & S H I E L D S E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 17 8/22/19 C4.01 DE T A I L E D G R A D I N G P L A N 09 NORTH ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R LEGEND: EXISTING DECID. TREE EXISTING CONIF. TREE EXISTING LIGHT POLE PROJECT BOUNDARY EXISTING CURB/GUTTER FLOWLINE 50 4:1BANK SLOPE PROPOSED ASPHALT CROSS SLOPE CONCENTRATED FLOW DIRECTION PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR 79.45PROPOSED FINISH GROUND ELEVATION (79.45)EXISTING GROUND ELEVATION PROPOSED INFLOW CURB/GUTTER FLOWLINE 2.0% NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 3.EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 4.REFER TO SITE PLAN, LANDSCAPE PLAN, AND PLAT FOR ADDITIONAL INFORMATION. 5.THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL EXISTING SEWER MAINS, WATER MAINS, CURBS, GUTTERS AND OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS, AND AT ANY UTILITY CROSSINGS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 6.SEE SHEET C2.00 FOR HORIZONTAL INFORMATION INCLUDING CURB AND GUTTER TYPES, PAN WIDTHS, DRIVE AISLE DIMENSIONS, EASEMENTS, ETC. EXISTING STORM SEWER LINE PROPOSED OUTFALL CURB/GUTTER FLOWLINE EXISTING ROW PROPOSED ROW EXISTING LOT LINE PROPOSED LOT LINE EASEMENT 1 MI N O R A M N E D M E N T - D R I V E A I S L E BR R 07 / 2 7 / 2 0 1 CONCRETE DETAILS THICKENED EDGE THES E R E C O R D D R A W I N G S , P R O D U C E D B Y N O R T H E R N E N G I N E E R I N G SERV I C E S , I N C . , A R E B A S E D I N W H O L E , O R I N P A R T , U P O N I N F O R M A T I O N PROV I D E D B Y O T H E R S . N O R T H E R N E N G I N E E R I N G S E R V I C E S , I N C . A S S U M E S NO L I A B I L I T Y F O R T H E A C C U R A C Y O R C O M P L E T E N E S S O F T H I S I N F O R M A T I O N . RECO R D D R A W I N G Stormwater Facility Name: Facility Location & Jurisdiction: User Input: Watershed Characteristics User Defined User Defined User Defined User Defined Selected BMP Type =EDB Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs] Watershed Area =0.38 acres 0.00 1 0.00 0.00 Watershed Length =200 ft 0.20 1 0.20 0.08 Watershed Length to Centroid =100 ft 1.20 371 1.20 0.46 Watershed Slope =0.020 ft/ft 2.15 1,453 2.15 0.65 Watershed Imperviousness =26.0%percent Percentage Hydrologic Soil Group A =0.0%percent Percentage Hydrologic Soil Group B =100.0%percent Percentage Hydrologic Soil Groups C/D =0.0%percent Target WQCV Drain Time =40.0 hours User Input After completing and printing this worksheet to a pdf, go to: https://maperture.digitaldataservices.com/gvh/?viewer=cswdif Create a new stormwater facility, and attach the PDF of this worksheet to that record. Routed Hydrograph Results Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 50 Year 100 Year One-Hour Rainfall Depth =N/A 0.88 1.17 1.48 2.50 3.07 in CUHP Runoff Volume =0.004 0.005 0.009 0.016 0.049 0.068 acre-ft Inflow Hydrograph Volume =N/A 0.005 0.009 0.016 0.049 0.068 acre-ft Time to Drain 97% of Inflow Volume =>120 0.6 0.6 0.7 1.5 1.8 hours Time to Drain 99% of Inflow Volume =>120 0.6 0.6 0.8 1.7 2.0 hours Maximum Ponding Depth =1.22 0.15 0.26 0.47 1.30 1.73 ft Maximum Ponded Area =0.01 0.00 0.00 0.00 0.01 0.02 acres Maximum Volume Stored =0.004 0.000 0.000 0.000 0.005 0.012 acre-ft Once CUHP has been run and the Stage-Area-Discharge information has been provided, click 'Process Data' to interpolate the Stage-Area-Volume-Discharge data and generate summary results in the table below. Once this is complete, click 'Print to PDF'. Stormwater Detention and Infiltration Design Data Sheet NEC Lake and Shields - North Pond Southwest Quarter of Section 14, T7N, R69W of the 6th PM, City of Fort Collins SDI-Design Data v2.00, Released January 2020 Location for 1-hr Rainfall Depths (use dropdown): After providing required inputs above including 1-hour rainfall depths, click 'Run CUHP' to generate runoff hydrographs using the embedded Colorado Urban Hydrograph Procedure. North Pond_SDI_Design_Data_v2.00.xlsm, Design Data 10/21/2020, 1:38 PM Booleans for Message Booleans for CUHP Watershed L:W 1 CUHP Inputs Complete Watershed Lc:L 1 CUHP Results Calculated Watershed Slope FALSE Time Interval RunOnce 1 CountA 1 Draintime Coeff 1.0 User Precip 1 Equal SA Inputs 1 Equal SD Inputs 1 Stormwater Detention and Infiltration Design Data Sheet 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.1 1 10 FL O W [ c f s ] TIME [hr] 100YR IN 100YR OUT 50YR IN 50YR OUT 10YR IN 10YR OUT 5YR IN 5YR OUT 2YR IN 2YR OUT WQCV IN WQCV OUT 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 0.1 1 10 100 PO N D I N G D E P T H [ f t ] DRAIN TIME [hr] 100YR 50YR 10YR 5YR 2YR WQCV North Pond_SDI_Design_Data_v2.00.xlsm, Design Data 10/21/2020, 1:38 PM Stormwater Facility Name: Facility Location & Jurisdiction: User Input: Watershed Characteristics User Defined User Defined User Defined User Defined Selected BMP Type =EDB Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs] Watershed Area =1.37 acres 0.00 33 0.00 0.00 Watershed Length =290 ft 0.80 350 0.80 1.27 Watershed Length to Centroid =145 ft 1.80 508 1.80 2.22 Watershed Slope =0.020 ft/ft 2.80 1,170 2.80 2.87 Watershed Imperviousness =70.0%percent 3.80 1,943 3.80 3.40 Percentage Hydrologic Soil Group A =0.0%percent 4.40 2,357 4.40 3.68 Percentage Hydrologic Soil Group B =100.0%percent Percentage Hydrologic Soil Groups C/D =0.0%percent Target WQCV Drain Time =40.0 hours User Input After completing and printing this worksheet to a pdf, go to: https://maperture.digitaldataservices.com/gvh/?viewer=cswdif Create a new stormwater facility, and attach the PDF of this worksheet to that record. Routed Hydrograph Results Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 50 Year 100 Year One-Hour Rainfall Depth =N/A 0.88 1.17 1.48 2.50 3.07 in CUHP Runoff Volume =0.031 0.061 0.087 0.118 0.233 0.300 acre-ft Inflow Hydrograph Volume =N/A 0.061 0.087 0.118 0.233 0.300 acre-ft Time to Drain 97% of Inflow Volume =>120 0.7 0.7 0.8 1.2 1.4 hours Time to Drain 99% of Inflow Volume =0.3 0.8 0.9 0.9 1.3 1.5 hours Maximum Ponding Depth =2.76 0.72 1.04 1.51 3.15 3.88 ft Maximum Ponded Area =0.03 0.01 0.01 0.01 0.03 0.05 acres Maximum Volume Stored =0.031 0.003 0.006 0.010 0.043 0.072 acre-ft Once CUHP has been run and the Stage-Area-Discharge information has been provided, click 'Process Data' to interpolate the Stage-Area-Volume-Discharge data and generate summary results in the table below. Once this is complete, click 'Print to PDF'. Stormwater Detention and Infiltration Design Data Sheet NEC Lake and Shields - South Pond Southwest Quarter of Section 14, T7N, R69W of the 6th PM, City of Fort Collins SDI-Design Data v2.00, Released January 2020 Location for 1-hr Rainfall Depths (use dropdown): After providing required inputs above including 1-hour rainfall depths, click 'Run CUHP' to generate runoff hydrographs using the embedded Colorado Urban Hydrograph Procedure. South Pond_SDI_Design_Data_v2.00.xlsm, Design Data 10/21/2020, 2:07 PM Booleans for Message Booleans for CUHP Watershed L:W 1 CUHP Inputs Complete Watershed Lc:L 1 CUHP Results Calculated Watershed Slope FALSE Time Interval RunOnce 1 CountA 1 Draintime Coeff 1.0 User Precip 1 Equal SA Inputs 1 Equal SD Inputs 1 Stormwater Detention and Infiltration Design Data Sheet 0 1 2 3 4 5 6 7 0.1 1 10 FL O W [ c f s ] TIME [hr] 100YR IN 100YR OUT 50YR IN 50YR OUT 10YR IN 10YR OUT 5YR IN 5YR OUT 2YR IN 2YR OUT WQCV IN WQCV OUT 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 0.1 1 10 100 PO N D I N G D E P T H [ f t ] DRAIN TIME [hr] 100YR 50YR 10YR 5YR 2YR WQCV South Pond_SDI_Design_Data_v2.00.xlsm, Design Data 10/21/2020, 2:07 PM