Loading...
HomeMy WebLinkAboutSite Certifications - 11/03/2017FORT COLLINS: 301 North Howes Street, Suite 100, 80521 | 970.221.4158 GREELEY: 820 8 th Street, 80631 | 970.395.9880 | WEB: www.northernengineering.com October 25, 2017 Wes Lamarque City of Fort Collins Stormwater Utility 700 Wood Street Fort Collins, Colorado 80521 RE: Site and Grading Certification for Landmark Residences on Mountain Ave. Fort Collins, Colorado Dear Wes: This drainage certification letter is provided to verify as-constructed conditions for Landmark Residences on Mountain Avenue. Northern Engineering completed survey work October 12, 2017 to verify general compliance with the Final Utility Plans for Landmark Residences, dated 11/15 by Northern Engineering. Northern Engineering Services, Inc. Included in this drainage certification submittal are the following: Attachment 1: City of Fort Collins Overall Site and Drainage Certification Form. Attachment 2: City of Fort Collins During Construction Inspection Checklist and photographs provided by contractor. Attachment 3: As constructed record drawings for Grading and Storm Drain Plan and Profile Sheets. Water quality treatment will be provided by permeable pavers located onsite. We have concluded, based on the attached information and personal site inspection, the drainage features for the project site were constructed in substantial compliance with the above referenced Final Utility Plans with the following exceptions. • Item III.A: The storm sewer from the existing inlet to combination Inlet A5 were not installed per the approved storm sewer drawings. Northern Engineering reanalyzed the capacity of the overall storm sewer system with the constructed conditions for the 2-Year Storm Event. Based on our analysis, ponding will occur at Inlet A5, Monitoring Well A7, and FES A3-3. Table 1 shows the effective ponding for the 2-Year Storm Event. Ponding at FES A3-3 will result in 0.10 cfs from the 2-Year Storm Event flowing towards the east along the alley. Accepted 11/3/2017 WL FORT COLLINS: 301 North Howes Street, Suite 100, 80521 | 970.221.4158 GREELEY: 820 8 th Street, 80631 | 970.395.9880 | WEB: www.northernengineering.com Table 1: 2-Year Storm Event Ponding Inlet As-Built Rim Elev. 2-Year WSE Depth of Ponding (ft) Basin A3 5023.75 5021.85 0.00 Monitoring Well A4 5023.41 5022.05 0.00 Inlet A5 5023.04 5023.31 0.27 Monitoring Well A6 5023.58 5023.38 0.00 Monitoring Well A7 5023.17 5023.40 0.23 Basin A3-1 5023.75 5022.00 0.00 *FES A3-3 5021.20 5021.76 0.56 Notes: * - 0.10 cfs will flow east down the alley. Figure 1: Hydraulic Grade Line Existing Inlet to Basin A3 • Item III.A.2: The underdrain from Existing Storm Inlet to Basin A3 (shown on Sheet C2.01) was constructed with a slope below the design of 0.40% (a slope of 0.25%. was constructed). We have re-analyzed this storm line and compared the hydraulic grade line. As shown in Ba s i n A 3 Cl e a n o u t A 2 Ex i s t i n g I n l e t FORT COLLINS: 301 North Howes Street, Suite 100, 80521 | 970.221.4158 GREELEY: 820 8 th Street, 80631 | 970.395.9880 | WEB: www.northernengineering.com Figure 1 Figure 1, the hydraulic grade line rises by 0.22’. As depicted in Table 1, this is below the FORT COLLINS: 301 North Howes Street, Suite 100, 80521 | 970.221.4158 GREELEY: 820 8 th Street, 80631 | 970.395.9880 | WEB: www.northernengineering.com rim of the Basin A3. Based on the revised HGL, we feel this will convey the design storm hydraulic capacity. • Item III.A.2: The underdrain from Basin A3 to Monitoring Well A4 (shown on Sheet C2.01) was constructed with a slope below the design of 0.40% (a slope of 0.22%. was constructed). We have re-analyzed this storm line and compared the hydraulic grade line. As shown in Figure 2Figure 2, the hydraulic grade line rises by 0.27’. As depicted on Table 1, this is below the rim of Monitoring Well A4. Based on the revised HGL, we feel this will convey the design storm hydraulic capacity. • Item III.A.2: The underdrain from Monitoring Well A4 to Inlet A5 (shown on Sheet C2.01) was constructed with a slope below the design of 0.40% (a slope of 0.25%. was constructed). We have re-analyzed this storm line and compared the hydraulic grade line. As shown in Figure 2Figure 2, the hydraulic grade line rises by 0.50’. As depicted in Table, this results in 0.27’ of ponding at Inlet A5 and 0.23’ of ponding at Monitoring Well A7. The storm sewer was re-analyzed assuming the permeable pavers near Inlet A5 and Monitoring Well A7 was completely blocked preventing infiltration. If properly maintained, the permeable pavers will reduce the amount of ponding that will occur at Inlet A5 and Monitoring Well A7. As shown in Figure 3 and Figure 4, there exists a 6” vertical curb along the north and west sides of the permeable pavers. This curb will help contain the ponding within the development. Northern Engineering feels the ponding at Inlet A5 and Monitoring Well A7 will not impact neighboring properties. Figure 2: Hydraulic Grade Line Basin A3 to Monitoring Well 7 In l e t A 5 Mo n i t o r i n g W e l l A6 Mo n i t o r i n g W e l l A 7 Mo n i t o r i n g W e l l A 4 Ba s i n A 3 FORT COLLINS: 301 North Howes Street, Suite 100, 80521 | 970.221.4158 GREELEY: 820 8 th Street, 80631 | 970.395.9880 | WEB: www.northernengineering.com Figure 3:Monitoring Well A4 & Inlet A5 Figure 4:Monitoring Wells A6 & A7 Monitoring Well A4 Inlet A5 Monitoring Well A6 Monitoring Well A7 FORT COLLINS: 301 North Howes Street, Suite 100, 80521 | 970.221.4158 GREELEY: 820 8 th Street, 80631 | 970.395.9880 | WEB: www.northernengineering.com • Item III.B.2: Northern Engineering did not observe construction. Northern Engineering was unable to verify encasements and clearances between storm sewer and existing and proposed utilities. • Item III.B.3: Northern Engineering did not observe construction. Northern Engineering was unable to verify the specific joint types used in construction of the storm sewer system. • Item VII.A: The underdrain from Basin A3 to Monitoring Well A4 (shown on Sheet C2.01) was constructed with a slope below the design of 0.40% (a slope of 0.22%. was constructed). We have re-analyzed this storm line and compared the hydraulic grade line. As shown in Figure 2Figure 2, the hydraulic grade line rises by 0.27’. As depicted on Table 1, this is below the rim of Monitoring Well A4. Based on the revised HGL, we feel this will convey the design storm hydraulic capacity. • Item VII.A: The underdrain from Monitoring Well A4 to Inlet A5 (shown on Sheet C2.01) was constructed with a slope below the design of 0.40% (a slope of 0.25%. was constructed). We have re-analyzed this storm line and compared the hydraulic grade line. As shown in Figure 2Figure 2, the hydraulic grade line rises by 0.50’. As depicted in Table, this results in 0.27’ of ponding at Inlet A5 and 0.23’ of ponding at Monitoring Well A7. The storm sewer was re-analyzed assuming the permeable pavers near Inlet A5 and Monitoring Well A7 was completely blocked preventing infiltration. If properly maintained, the permeable pavers will reduce the amount of ponding that will occur at Inlet A5 and Monitoring Well A7. As shown in Figure 3 and Figure 4, there exists a 6” vertical curb along the north and west sides of the permeable pavers. This curb will help contain the ponding within the development. Northern Engineering feels the ponding at Inlet A5 and Monitoring Well A7 will not impact neighboring properties. • Item VII.A.2: According to the Contractor, the underdrain was installed per the design drawings. Northern Engineering did not observe installation of underdrain and was unable to verify the perforated and non-perforated sections of the underdrain. • Item VII.A.5: According to the Contractor, the underdrain was installed per the design drawings. Northern Engineering did not observe installation of underdrain and was unable to verify type, depth, and width of backfill material. • Item VII.A.6: According to the Contractor, the underdrain was installed per the design drawings. Northern Engineering did not observe installation of underdrain and was unable to verify if the underdrain was wrapped with geotextile fabric. Please feel free to contact me with any questions you may have. Thank You, NORTHERN ENGINEERING Frederick S. Wegert, PE Project Engineer N. S H I E L D S S T . W. MULBERRY ST. MOUNTAIN AVE. VARIES CONCRETE DRIVE PUBLIC ALLEY (20' ROW) LO T L I N E LO T L I N E SLOPE VARIES (0.5-3.0%) No . Re v i s i o n s : By : Da t e : RE V I E W E D B Y : R. C u r t i s s DE S I G N E D B Y : DR A W N B Y : SC A L E : DA T E : No v e m b e r 2 , 2 0 1 5 PR O J E C T : 10 2 2 - 0 0 1 Sheet Of 17 Sheets LA N D M A R K R E S I D E N C E S O N M O U N T A I N A V E N U E DR A W I N G F I L E N A M E : D : ro j e c t s \ 1 0 2 2 - 0 0 1 \ D w g \ R e c o r d D r a w i n g s \ 1 0 2 2 - 0 0 1 _ C o v e r _ A B . d w g L A Y O U T N A M E : C S 1 D A T E : O c t 2 5 , 2 0 1 7 - 8 : 2 6 a m C A D O P E R A T O R : f r e d LI S T O F X R E F S : [ N E S - x b o r d e r ] Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . 30 1 N o r t h H o w e s S t r e e t , S u i t e 0 1 0 Fo r t C o l l i n s , C o l o r a d o 8 0 5 2 1 E N G I N E E R N G I E H T R O N R N PH O N E : 9 7 0 . 2 2 1 . 4 1 5 8 F A X : 9 7 0 . 2 2 1 . 4 1 5 9 ww w . n o r t h e r n e n g i n e e r i n g . c o m C0.00 CO V E R S H E E T C. S n o w d o n A. B o e s e N. A . NOVEMBER 2015 CONTACT INFORMATION PROJECT TEAM: ROF Properties, LLC C/O Firsthand Management LLC 5271 S. Yampa St. Centennial, CO 80015 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER Northern Engineering Services, Inc. Bud Curtiss, PE, 301 N. Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R N GIEHTRONRN PLANNER/ LANDSCAPE ARCHITECT These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: PROJECT LOCATION VICINITY MAP 1"=1500'NORTH DEVELOPER/APPLICANT SITE ENGINEER SURVEYOR PROJECT DATUM: NAVD88 BENCHMARK #1: City of Fort Collins Benchmark 3-08 Southwest corner of Mulberry St. and Shields St. on a concrete traffic signal base Elevation = 5030.29 BENCHMARK #2: City of Fort Collins Benchmark 31-97 Southwest corner of Laporte Ave. and Sheilds St., on a concrete traffic signal base. Elevation = 5023.65 Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.17'. Basis of Bearings Basis of Bearings is the East right-of-way line of North Shields Street as bearing North 00° 35' 27" East (assumed bearing). Original Field Survey by: Northern Engineering Services Project #1022-001 Date: April, 23 2014 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R SHEET INDEX COVER SHEET EXISTING CONDITIONS UTILITY SHEETS GENERAL & CONSTRUCTION NOTES C0.00 C0.01 EXISTING CONDITIONS & DEMOLITION PLANC1.00 UTILITY PLANC2.00 DRAINAGE & DRAINAGE C6.00 DRAINAGE EXHIBIT I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. CERTIFICATION STATEMENT: GRADING AND EROSION CONTROL SHEETS EROSION CONTROL DETAILSC3.02 UTILITY PLANS FOR LOCATED IN THE SOUTHWEST QUARTER OF SECTION 11, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO (1032 W. MOUNTAIN AVENUE) LANDMARK RESIDENCES ON MOUNTAIN AVENUE Ripley Design, Inc. Brent Cooper 401 West Mountain Avenue Fort Collins, Colorado 80521 (970) 224-5828■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ Northern Engineering Services, Inc. Eric Smith, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R N GIEHTRONRN STREET SHEETS PUBLIC ALLEY ROADWAY PLAN & PROFILE C4.00 PUBLIC ALLEY CROSS SECTIONS C4.01 GRADING PLANC3.00 EROSION CONTROL STATIC PLANC3.01 DETAIL SHEETS C5.00-C5.04 CONSTRUCTION DETAILS GAS-----------------Xcel Energy-----------------------------Stephanie Rich (970) 225-7857 ELECTRIC--------City of Fort Collins Light & Power --Justin Fields (970) 224-6150 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities -----------Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins Utilities -----------Shane Boyle (970) 221-6339 STORMWATER-City of Fort Collins Utilities -----------Glen Schlueter (970) 221-6700 Vaught Frye Larson Architects Taylor Meyer, AIA LEED AP BD+C 419 Canyon Avenue, Suite 200 Fort Collins, CO 80521 (970) 224-1191 ARCHITECT VAUGHT FRYE LARSON architects STORM DRAIN PLANC2.01 C6.01 FLOODPLAIN EXHIBIT 1 1 1 1 RE V I S E D M I N . O P E N I N G E L E V A T I O N S - L O T S 7 - 1 0 CN S 03 . 3 0 . 1 6 RECO R D D R A W I N GTHESE RECORD DRAWINGS, PRODUCED BY NORTHERN ENGINEERINGSERVICES, INC., ARE BASED ON FIELD INFORMATION GATHERED BYOTHERS. NORTHERN ENGINEERING SERVICES, INC. ASSUMES NOLIABILITY FOR THE ACCURACY OF THIS FIELD INFORMATION. 2 RE C O R D D R A W I N G S MC R 10 / 2 5 / 2 0 1 7 2 2 2 2 2 MH TELE WV WV WV HYDWV VAULT ELEC CONTROL IRR W W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXX E E E E T S TRAFFIC VAULT TRAFFIC VAULT TRAFFIC VAULT E X W W W W W W W W W W W W W W W W W W W W UD UD UD UD UD UD UD UD UD UD UD W W W W W W S S S S S S S W CO CO CO CO CO EEEEE E G G GG G G GE E E E E E G G G G G G G G G G G E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G EV E E E E E E E E E E E E E E E E E E E E E E E E E DENEK JASON T/ CHISTINE D 9852 CLAIRTON PL LITTLETON, CO 80126 W. MOUNTAIN AVE. (140' ROW) N. S H I E L D S S T . (6 0 ' R O W ) FR A R E B A R B A R A L 10 1 6 W . M O U N T A I N A V E . FO R T C O L L I N S , C O 8 0 5 2 1 BE A V E R S M A R K E T I N C N O . 3 11 0 0 W . M O U N T A I N A V E . FO R T C O L L I N S , C O 8 0 5 2 1 CH I L D R E N S H O U S E MO N T E S S O R I S C H O O L L L C 11 3 N . S H I E L D S S T . FO R T C O L L I N S , C O 8 0 5 2 1 PUBLIC ALLEY 6' SIDEWALK PROPOSED 1" RESIDENTIAL WATER SERVICE (TYP.) EXISTING FIRE HYDRANT 33 ± L F 1 - 1 / 2 " WA T E R S E R V I C E COMMON PRIVATE DOMESTIC WATER SERVICE INSTALL CITY CURB STOP 21 ' A D D I T I O N A L RI G H T - O F - W A Y PROPOSED 4" RESIDENTIAL SANITARY SERVICE (TYP.) PROPOSED 1" COMMERCIAL WATER SERVICE (TYP.) 18± LF 1-1/2" WATER SERVICE 12± LF 1-1/2" WATER SERVICE 18± LF 1-1/2" WATER SERVICE 3± LF 1-1/2" WATER SERVICE 18 ± L F 1 " WA T E R S E R V I C E 26 ± L F 1 " WA T E R S E R V I C E 25 ± L F 1 " WA T E R S E R V I C E 18 ± L F 1 " WA T E R S E R V I C E 15± LF 1" WATER SERVICE EXISTING 8" WATER MAIN INSTALL 1" WATER SERVICE PRIVATE 1" CURB STOP & 3/4" METER EXISTING 8" SEWER MAIN 58 ± L F 4 " P V C @ 2 . 0 0 % S . S . 62 ± L F 4 " P V C @ 2 . 0 0 % S . S . 55 ± L F 4 " P V C @ 2 . 0 0 % S . S . 55 ± L F 4 " P V C @ 2 . 0 0 % S . S . 62 ± L F 4 " P V C @ 2 . 0 0 % S . S . 22 ± L F 4 " P V C @ 2 . 0 0 % S . S . SS SERVICE 6 INV.=5017.15 FG=5023.85 SS SERVICE 5 6"x4" TEE w/ 4" REDUCER INV.=5016.51 FG=5023.55 SS SERVICE 4 6"x4" TEE INV.=5016.15 FG=5023.40 SS SERVICE 3 6"x4" TEE INV.=5016.03 FG=5023.42 SS SERVICE 2 6"x4" TEE INV.=5015.43 FG=5023.33 SS SERVICE 1 6"x4" TEE INV.=5015.31 FG=5023.32 INSTALL RESIDENTIAL SERVICE CONNECTION INV.=5013.23 FG=5022.85 96.00 LF 6" PVC @ 2.00% 6.00 LF 6" PVC @ 2.00% 30.00 LF 6" PVC @ 2.00%6.00 LF 6" PVC @ 2.00% 18.00 LF 6" PVC @ 2.00% 19.7 1 L F 4 " P V C @ 2 . 0 0 % EXISTING STORM INLET GRATE EL=5021.45 BTM SILTED IN FL=5020.05 (W) 8" SILT TO BE REMOVED PRIVATE 1" CURB STOP & 3/4" METER PRIVATE 1" CURB STOP & 3/4" METER PRIVATE 1" CURB STOP & 3/4" METER EXISTING GAS VALVE EXISTING WATER METER 1-1/2" x 1" TEE W/ STIFFENER (TYPICAL) 1-1/2" TEE W/ 1" REDUCER & STIFFENER 49.34 LF 4" PVC @ 2.00% INSTALL 45° BEND INV.=5014.54 FG=5023.63 26.5 9 L F 4" P V C@ 2. 0 0 % INSTALL 45° BEND INV.=5015.07 FG=5024.07 INSTALL COMMERCIAL SERVICE CONNECTION INV.=5013.22 FG=5022.83 PROPOSED TRANSFORMER PRIVATE STORM LINE TO BE OWNED AND MAINTAINED BY THE HOA RELOCATED ELECTRIC VAULT PROPOSED TRAFFIC RATED CLEANOUTS INSTALL 45° BEND INV.=5016.76 FG=5023.54 APPROXIMATE LIMITS OF ASPHALT PATCHING (SEE NOTE 7) APPROXIMATE LIMITS OF ASPHALT PATCHING (SEE NOTE 7) 4.06 LF 4" PVC @ 2.00% CONNECT TO EXISTING GAS PROPOSED ELEC. SERVICE CONNECT TO EXISTING ELECTRIC PROPOSED UNDERDRAIN SEE SHEET C2.01 PROPOSED STORM DRAIN SEE SHEET C2.01 PROPOSED STORM DRAIN SEE SHEET C2.01 ELECTRIC METER PROPOSED TRAFFIC RATED CLEANOUTS PROPOSED TRAFFIC RATED CLEANOUT PROPOSED CLEANOUT PROPOSED STORM DRAIN SEE SHEET C2.01 GAS METER PROPOSED COMMON RESIDENTIAL SEWER SERVICE PROPOSED GAS SERVICE 23 ± L F 1 " WA T E R S E R V I C E 26 ± L F 1 " WA T E R S E R V I C E 16± LF 1" WATER SERVICE 23± L F 1 " WAT E R S E R V I C E INSTALL 1-1/2" WATER SERVICE INSTALL 1" METER W/ CURB STOP ELECTRIC METER GAS METER ELECTRIC METER GAS METER ELECTRIC METER GAS METER ELECTRIC METER GAS METER ELECTRIC METER GAS METER UTILITY EASEMENT 91± LF 1" WATER SERVICE ELECTRIC METER WALL PENETRATIONS TO BE COORDINATED WITH STRUCTURAL ENGINEER WALL PENETRATIONS TO BE COORDINATED WITH STRUCTURAL ENGINEER APPROXIMATE LOCATION OF RELOCATED WATER LINE. CONTRACTOR TO LOCATE PRIOR TO CONSTRUCTION OR ORDERING OF MATERIALS PROPOSED 4" COMMERCIAL SANITARY SERVICE (TYP.) GAS METER ELECTRIC METER GREASE TRAP OUT INV.=5015.10 FG=5024.11 GREASE TRAP IN INV.=5015.27 FG=5024.26 18 . 0 0 L F 4 " P V C @ 2 . 0 0 % PROPOSED TRAFFIC RATED CLEANOUT 1-1/2" x 1" TEE W/ 1" REDUCER & STIFFENER PROPOSED COMMERCIAL SEWER SERVICE C.O. W CS CS W W CS CSW WCS W CS CS CS W C.O.C.O. C.O. C.O. C.O. ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// No . Re v i s i o n s : By : Da t e : RE V I E W E D B Y : R. C u r t i s s DE S I G N E D B Y : DR A W N B Y : SC A L E : DA T E : No v e m b e r 2 , 2 0 1 5 PR O J E C T : 10 2 2 - 0 0 1 Sheet Of 17 Sheets LA N D M A R K R E S I D E N C E S O N M O U N T A I N A V E N U E DR A W I N G F I L E N A M E : D : ro j e c t s \ 1 0 2 2 - 0 0 1 \ D w g \ R e c o r d D r a w i n g s \ 1 0 2 2 - 0 0 1 _ U T I L _ A B . d w g L A Y O U T N A M E : C 2 . 0 0 D A T E : O c t 2 5 , 2 0 1 7 - 9 : 1 5 a m C A D O P E R A T O R : f r e d LI S T O F X R E F S : [ 1 0 2 2 - 0 0 1 _ x E x s t ] [ 1 0 2 2 - 0 0 1 _ x P u t i l ] [ 1 0 2 2 - 0 0 1 _ x S i t e ] [ N E S - x b o r d e r ] [ 1 0 2 2 - 0 0 1 _ U t i l i t y _ A s - b u i l t s ] Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . 30 1 N o r t h H o w e s S t r e e t , S u i t e 0 1 0 Fo r t C o l l i n s , C o l o r a d o 8 0 5 2 1 E N G I N E E R N G I E H T R O N R N PH O N E : 9 7 0 . 2 2 1 . 4 1 5 8 F A X : 9 7 0 . 2 2 1 . 4 1 5 9 ww w . n o r t h e r n e n g i n e e r i n g . c o m C2.00 UT I L I T Y P L A N C. S n o w d o n A. B o e s e 1" = 1 0 ' NORTH NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. MAINTAIN 3' HORIZONTAL SEPARATION BETWEEN ALL GAS AND ELECTRIC SERVICE LINES. 6.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. {7.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. } 8.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 9.ALL INDIVIDUAL WATER SERVICES LINES ARE TO BE INSTALLED WITH A CURB STOP AND A METER OUTSIDE OF THE BUILDING.{ 10.REFER TO MECHANICAL PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS BOTH THE MECHANICAL ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 11.WATER SERVICE LINES BEYOND CITY CURB STOPS ADJACENT TO MOUNTAIN AVENUE AND SANITARY SEWER SERVICE LINES EXTENDING FROM SHIELDS STREET PUBLIC MAIN INTO THE SITE ARE TO BE MAINTAINED BY THE HOMEOWNERS ASSOCIATION. }12.A FLOODPLAIN USE PERMIT IS REQUIRED PRIOR TO ANY WORK WITHIN THE HIGH-RISK FLOOD FRINGE AND FLOODWAY. SEE SHEET C6.01 FOR FLOODPLAIN INFORMATION. 13.A NO-RISE CERTIFICATION IS REQUIRED PRIOR TO ANY CONSTRUCTION WITHIN THE FLOODWAY. SEE SHEET C6.01 FOR FLOODPLAIN INFORMATION. 14.SEE FLOODPLAIN EXHIBIT ON SHEET C6.01 FOR FLOODPLAIN EXISTING LOT LINE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: W G CTV E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS PROPOSED ELECTRIC TRANSFORMER S WPROPOSED WATER SERVICE EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT EXISTING FIRE HYDRANT H YD PROPOSED EASEMENT LINE PROPERTY BOUNDARY PROPOSED ASPHALT PATCH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R W ( IN FEET ) 1 inch = ft. Feet01010 10 20 30 PROPOSED LOT LINE 2 RE C O R D D R A W I N G S FS W 10 / 2 5 / 1 7 RECO R D D R A W I N GTHESE RECORD DRAWINGS, PRODUCED BY NORTHERN ENGINEERINGSERVICES, INC., ARE BASED ON FIELD INFORMATION GATHERED BYOTHERS. NORTHERN ENGINEERING SERVICES, INC. ASSUMES NOLIABILITY FOR THE ACCURACY OF THIS FIELD INFORMATION. MH TELE WV WV WV HYDWV VAULT ELEC CONTROL IRR W GASW W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXX E E E E T S TRAFFIC VAULT TRAFFIC VAULT TRAFFIC VAULT E X W W W W W W W W W W W W W W W W W W W W UD UD UD UD UD UD UD UD UD UD UD W W W W W W S S S S S S S W CO CO CO CO CO EEEEE E G G GG G G GE E E E E E G G G G G G G G G G G E E E E E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G EV E E E E E E E E E E E E E E E E E E E E E E E E E DENEK JASON T/ CHISTINE D 9852 CLAIRTON PL LITTLETON, CO 80126 W. MOUNTAIN AVE. (140' ROW) N. S H I E L D S S T . (6 0 ' R O W ) FR A R E B A R B A R A L 10 1 6 W . M O U N T A I N A V E . FO R T C O L L I N S , C O 8 0 5 2 1 BE A V E R S M A R K E T I N C N O . 3 11 0 0 W . M O U N T A I N A V E . FO R T C O L L I N S , C O 8 0 5 2 1 CH I L D R E N S H O U S E MO N T E S S O R I S C H O O L L L C 11 3 N . S H I E L D S S T . FO R T C O L L I N S , C O 8 0 5 2 1 PUBLIC ALLEY 6' SIDEWALK EXISTING FIRE HYDRANT 21 ' A D D I T I O N A L RI G H T - O F - W A Y EXISTING 8" WATER MAIN EXISTING 8" SEWER MAIN EXISTING STORM INLET GRATE EL=5021.45 BTM SILTED IN FL=5020.05 (W) 8" (SILT TO BE REMOVED) PROPOSED CLEANOUTS (TYPICAL) EXISTING GAS VALVE EXISTING WATER METER PROPOSED TRANSFORMER PRIVATE STORM LINE TO BE OWNED AND MAINTAINED BY THE HOA 12" DRAIN BASIN A3-1 w/ SOLID LID INV.=5021.05 FG=5023.86 12" DRAIN BASIN A3 w/ SOLID LID INV.=5020.58 FG=5024.22 MONITORING WELL A6 w/ SOLID LID INV.=5021.05 FG=5023.54 MONITORING WELL A4 w/ SOLID LID INV.=5020.66 FG=5023.52 COMBINATION INLET A5 w/ GRATED LID INV.=5020.90 FG=5023.24 MONITORING WELL A7 w/ 8" TRAFFIC RATED GRATE INV.=5021.14 FG=5022.96 45° BEND INV.=5021.33 FG=5023.03 PIPE END A3-3 w/ CONCRETE COLLAR INV.=5021.35 FG=5021.35 CLEANOUT A2 INV.=5020.17 FG=5022.82 59.30 LF 6" PERF. PVC @ 0.40% 20 . 1 2 L F 8" P V C @ 0 . 4 0 % RELOCATED ELECTRIC VAULT PROPOSED CLEANOUTS (TYPICAL) 21. 5 8 L F 8 " P V C @ 0 . 4 0 % 1.29 LF 8" PVC @ 0.40% 12" DRAIN BASIN A3-2 w/ 8" GRATE INV.=5021.10 FG=5023.90 8"x8" TEE INV.=5020.71 FG=5024.45 8"x4" TEE INV.=5020.78 FG=5024.55 8" DRAIN BASIN W/ 8" GRATE INV=5021.46 FG=5024.80 8" DRAIN BASIN W/ 8" GRATE INV=5021.68 FG=5024.80 8"x4" TEE INV.=5021.27 FG=5024.99 4"x8" TEE w/ CLEANOUT INV.=5021.49 FG=5025.24 8"x8" TEE INV.=5020.86 FG=5024.10 8"x4" CROSS INV.=5020.93 (N) FG=5024.40 8"x4" TEE INV.=5021.34 FG=5024.77 4"x8" TEE w/ CLEANOUT INV.=5021.58 FG=5024.83 8"x4" TEE INV.=5021.48 FG=5024.76 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 4"x8" TEE w/ CLEANOUT INV.=5021.69 FG=5024.82 8"x4" TEE INV.=5021.05 FG=5024.39 8"x4" TEE INV.=5021.46 FG=5024.77 8"x4" TEE INV.=5021.60 FG=5024.76 8" DRAIN BASIN W/ 8" GRATE INV=5021.73 FG=5024.69 90° BEND w/ CLEANOUT INV.=5021.59 FG=5024.72 8"x4" TEE w/ 8"x4" REDUCER INV.=5021.12 FG=5023.95 4" ROOF LEADER 4" ROOF LEADER 8"x8" TEE INV.=5020.98 FG=5023.95 12" DRAIN BASIN A3-3 W/ SOLID LID INV.=5021.19 FG=5023.04 90° BEND w/ CLEANOUT INV.=5021.26 FG=5022.41 4" ROOF LEADER 4" ROOF LEADER 4" ROOF LEADER 8"x4" TEE INV.=5021.18 FG=5023.72 8"x4" TEE INV.=5021.23 FG=5023.73 8" DRAIN BASIN W/ 8" GRATE INV=5021.66 FG=5024.70 APPROXIMATE LIMITS OF ASPHALT PATCHING (SEE NOTE 7) APPROXIMATE LIMITS OF ASPHALT PATCHING (SEE NOTE 7) 8" DRAIN BASIN W/ 8" GRATE INV=5021.54 FG=5024.70 29.57 LF 8" PVC @ 0.40%15 . 4 3 L F 8 " P V C @ 0 . 4 0 % 21 . 1 7 L F 6 " P E R F . P V C @ 0 . 4 0 % 37.41 LF 6" PERF. PVC @ 0.40% 32.14 LF 8" PVC @ 0.40% 33 . 8 4 L F 8 " P V C @ 0 . 4 0 % 5.26 LF 8" PVC @ 0.40% 36.01 LF 8" PVC @ 0.40%30.23 LF 8" PVC @ 0.40%16.22 LF 8" PVC @ 0.40% 11.92 LF 8" PVC @ 0.40% 3.72 LF 8" PVC @ 2.00% 24 . 2 3 L F 8" P V C @ 2 . 0 0 % 10 . 9 3 L F 8" P V C @ 2 . 0 0 % 11.06 LF 4" PVC @ 2.00%9.61 LF 4" PVC @ 2.00% 3.71 LF 8" PVC @ 2.00% 20.23 LF 8" PVC @ 2.00% 6. 8 7 L F 8" P V C @ 2 . 0 0 % 5. 3 0 L F 8" P V C @ 2 . 0 0 % 3.70 LF 8" PVC @ 2.00% 20 . 2 3 L F 8 " P V C @ 2 . 0 0 % 4.00 LF 8" PVC @ 2.00% 9.39 LF 4" PVC @ 2.00% 4.89 LF 8" PVC @ 2.00% 15 . 0 0 L F 4" P V C @ 2 . 0 0 % 3.70 LF 8" PVC @ 2.00% 11 . 9 8 L F 8" P V C @ 0 . 4 0 % 24 . 1 2 L F 8 " P V C @ 0 . 4 0 % 2.83 LF 4" PVC @ 2.00% 2.82 LF 4" PVC @ 2.00% PROPOSED ELEC. SERVICE CONNECT TO EXISTING ELECTRIC PROPOSED SANITARY SERVICE SEE SHEET C2.00 PROPOSED SANITARY SERVICE SEE SHEET C2.00 8"x4" TEE INV.=5020.23 FG=5022.93 15.16 LF 4" PVC @ 2.00% 15.07 LF 4" PVC @ 2.00% 14 . 5 5 L F 8 " P V C @ 0 . 4 0 % 20 . 6 7 L F 8 " P V C @ 0 . 4 0 % 15.16 LF 4" PVC @ 2.00% 8"x4" TEE INV.=5020.37 FG=5023.98 8"x4" TEE INV.=5020.29 FG=5023.38 15 . 0 0 L F 8 " P V C @ 0 . 4 0 % 15.16 LF 4" PVC @ 2.00% 8"x4" TEE INV.=5020.43 FG=5024.42 38 . 2 9 L F 8 " P V C @ 0 . 4 0 % MECHANICAL CONNECTION (SEE PLUMBING PLANS) MECHANICAL CONNECTION (SEE PLUMBING PLANS) MECHANICAL CONNECTION (SEE PLUMBING PLANS) MECHANICAL CONNECTION (SEE PLUMBING PLANS) 2.89 LF 8" PVC @ 2.00% 8"x4" TEE INV.=5021.54 FG=5024.74 8"x4" TEE w/ 8"x4" REDUCER INV.=5021.20 FG=5023.01 15.83 LF 4" PVC @ 0.40% EXISTING 8" WASTER MAIN PROPOSED PRIVATE RESIDENTIAL WATER SERVICE (SEE SHEET C2.00) PROPOSED PRIVATE COMMERCIAL WATER SERVICE (SEE SHEET C2.00) {\ F a r c h i t x t | c 0 ; 1 3 . 6 L F @ 0 . 2 2 % } {\Farchitxt|c0;56.9 LF @ 0.25%}{\Farchitxt|c0;39.6 LF @ 0.53%} {\ F a r c h i t x t | c 0 ; 2 0 . 9 L F @ 1 . 4 % } {\Farchitxt|c0;124.2 LF @ 0.4%} {\Farchitxt|c0;28.91 LF @ 0.26%} C.O. W CS CS W W CS CSW WCS W CS CS CS W C.O.C.O. C.O. C.O. C.O. ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// {INV.=5021.83 FG=5024.83} {INV.=5020.28 FG=5022.55} {\ F a r c h i t x t | c 0 ; 1 0 7 . 7 9 L F @ 0 . 2 6 % } {INV.=5021.20 FG=5021.20} {\ F a r c h i t x t | c 0 ; 7 0 . 3 3 L F @ 0 . 4 % } {\ F a r c h i t x t | c 0 ; 2 6 . 2 4 L F @ 0 . 5 % } No . Re v i s i o n s : By : Da t e : RE V I E W E D B Y : R. C u r t i s s DE S I G N E D B Y : DR A W N B Y : SC A L E : DA T E : No v e m b e r 2 , 2 0 1 5 PR O J E C T : 10 2 2 - 0 0 1 Sheet Of 17 Sheets LA N D M A R K R E S I D E N C E S O N M O U N T A I N A V E N U E DR A W I N G F I L E N A M E : D : ro j e c t s \ 1 0 2 2 - 0 0 1 \ D w g \ R e c o r d D r a w i n g s \ 1 0 2 2 - 0 0 1 _ S T R M _ A B . d w g L A Y O U T N A M E : C 2 . 0 1 D A T E : O c t 2 5 , 2 0 1 7 - 9 : 1 1 a m C A D O P E R A T O R : f r e d LI S T O F X R E F S : [ 1 0 2 2 - 0 0 1 _ x E x s t ] [ 1 0 2 2 - 0 0 1 _ x P u t i l ] [ 1 0 2 2 - 0 0 1 _ x S i t e ] [ N E S - x b o r d e r ] [ 1 0 2 2 - 0 0 1 _ U t i l i t y _ A s - b u i l t s ] Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . 30 1 N o r t h H o w e s S t r e e t , S u i t e 0 1 0 Fo r t C o l l i n s , C o l o r a d o 8 0 5 2 1 E N G I N E E R N G I E H T R O N R N PH O N E : 9 7 0 . 2 2 1 . 4 1 5 8 F A X : 9 7 0 . 2 2 1 . 4 1 5 9 ww w . n o r t h e r n e n g i n e e r i n g . c o m C2.01 ST O R M D R A I N P L A N C. S n o w d o n A. B o e s e 1" = 1 0 ' NORTH NOTES: EXISTING LOT LINE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: W G CTV E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS S WPROPOSED WATER SERVICE EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED CURB STOP & METER PIT EXISTING FIRE HYDRANT H YD PROPOSED EASEMENT LINE PROPERTY BOUNDARY CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R W ( IN FEET ) 1 inch = ft. Feet01010 10 20 30 PROPOSED ELECTRIC TRANSFORMER PROPOSED ASPHALT PATCH PROPOSED LOT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. MAINTAIN 3' HORIZONTAL SEPARATION BETWEEN ALL GAS AND ELECTRIC SERVICE LINES. 6.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. {7.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. } 8.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 9.ALL INDIVIDUAL WATER SERVICES LINES ARE TO BE INSTALLED WITH A CURB STOP AND A METER OUTSIDE OF THE BUILDING.{ 10.REFER TO MECHANICAL PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS BOTH THE MECHANICAL ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 11.WATER SERVICE LINES BEYOND CITY CURB STOPS ADJACENT TO MOUNTAIN AVENUE AND SANITARY SEWER SERVICE LINES EXTENDING FROM SHIELDS STREET PUBLIC MAIN INTO THE SITE ARE TO BE MAINTAINED BY THE HOMEOWNERS ASSOCIATION. }12.A FLOODPLAIN USE PERMIT IS REQUIRED PRIOR TO ANY WORK WITHIN THE HIGH-RISK FLOOD FRINGE AND FLOODWAY. SEE SHEET C6.01 FOR FLOODPLAIN INFORMATION. 13.A NO-RISE CERTIFICATION IS REQUIRED PRIOR TO ANY CONSTRUCTION WITHIN THE FLOODWAY. SEE SHEET C6.01 FOR FLOODPLAIN INFORMATION. 14.SEE FLOODPLAIN EXHIBIT ON SHEET C6.01 FOR FLOODPLAIN 2 RE C O R D D R A W I N G S FS W 10 / 2 5 / 1 7 RECO R D D R A W I N GTHESE RECORD DRAWINGS, PRODUCED BY NORTHERN ENGINEERINGSERVICES, INC., ARE BASED ON FIELD INFORMATION GATHERED BYOTHERS. NORTHERN ENGINEERING SERVICES, INC. ASSUMES NOLIABILITY FOR THE ACCURACY OF THIS FIELD INFORMATION. UD UD UD UD UD UD UD UD UD UD UD CO CO CO CO CO MH TELE CONTROL IRR W VAULT GAS W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXX XXXXXX E E E E T S TRAFFIC VAULT TRAFFIC VAULT TRAFFIC VAULT E VAULT CABLE VAULT ELEC X X FFE=25.90 FFE=26.40 FFE=26.40 FFE=26.40 FFE=26.40 FFE=26.40 FFE=26.40 DENEK JASON T/ CHISTINE D 9852 CLAIRTON PL LITTLETON, CO 80126 N. S H I E L D S S T . (6 0 ' R O W ) FRARE BARBARA L 1016 W. MOUNTAIN AVE. FORT COLLINS, CO 80521 BEAVERS MARKET INC NO.3 FORT COLLINS, CO 80521 PERFORATED MONITORING WELL COMBINATION INLETPERFORATED MONITORING WELL 6" PERFORATED UNDERDRAIN 6" PERFORATED UNDERDRAIN 8" SOLID OUTLET PIPE RAMP RAMP RAMP PERMEABLE PAVERS PERMEABLE PAVERS 18" INFLOW CURB & GUTTER INSTALL TRUNCATED DOME 2-RISERS 6-RISERS 5-RISERS 2-RISERS PERFORATED MONITORING WELL W/ OPEN GRATE DRAIN BASIN CLEANOUT PIPE END w/ CONCRETE COLLAR DRAIN BASIN w/ OPEN GRATE CLEANOUT CLEANOUT CLEANOUTCLEANOUT CLEANOUT DRAIN BASIN w/ GRATE DRAIN BASIN w/ GRATE DRAIN BASIN w/ GRATE DRAIN BASIN DRAIN BASIN PROPOSED ELECTRIC TRANSFORMER 2.27' CURB CUT3.77' CURB CUT OUTFALL CURB & GUTTER THICKENED EDGE THICKENED EDGE OUTFALL CURB & GUTTER THICKENED EDGE THICKENED EDGE 4-RISERS 4-RISERS 4-RISERS 4-RISERS 4-RISERS 2-RISERS 2-RISERS 2-RISERS2-RISERS2-RISERS 4-RISERS LANDING RAMP 1-RISER 2-RISERS 2-RISERS2-RISERS 2-RISERS OUTFALL CURB & GUTTER OUTFALL CURB & GUTTER 1 1 C.O. W CS CS W W CS CSW WCS W CS CS CS W C.O.C.O. C.O. C.O. C.O. ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// 25.85AB 25.88AB 25.84AB 25.78AB 25.81 AB 25.88AB 25.81AB 23.73AB 25.79AB 25.71AB 22.88AB23 . 3 6 AB 22.78AB23 . 3 7 AB 23.52AB 22.94AB 22.90AB 23.49AB 23.23AB 23.83AB23.83AB 23.24 AB 22 . 5 2 AB 22.98 AB 22 . 5 5 AB 23.10 AB 22.86AB 22 . 2 8 AB 22 . 2 8 AB 22.85AB 22.13 AB 22.72AB 22 . 1 4 AB 22.72AB 22 . 0 7 AB22 . 1 0 AB22 . 2 2 AB 22 . 1 9 AB 22 . 0 0 AB 21 . 9 8 AB 21 . 8 7 AB 21 . 8 6 AB 21 . 7 4 AB 21 . 6 7 AB 21 . 6 0 AB 21 . 5 6 AB 21 . 4 3 AB 22.77AB22.15AB 22.17AB 22.72AB 21 . 8 0 AB 22.38AB 21 . 7 6 AB 22.39 AB 23 . 8 9 AB 23.98AB 23.94AB 25 . 8 7 AB 25.68AB 23.78AB 25 . 8 4 AB 24.48AB 25.75AB 25 . 6 6 AB 25 . 7 3 AB 25.73 AB 25 . 8 7 AB 25.87AB 25 . 8 6 AB 25.74 AB 23.36AB 22.82AB 22.75AB23 . 3 5 AB 23.76AB 23.95AB 23.84AB 25.82AB 23 . 3 4 AB 23.36AB 25 . 8 0 AB25 . 7 6 AB 25.78AB 25.86AB 23.30AB23.27AB 25.82AB 21 . 8 9 AB 24 . 4 0 AB 24 . 4 4 AB 24.31AB 24.18AB22.11AB 22.13AB 23.18AB 23.03AB22.22AB 24.56AB 24.36AB 24.29AB 23.90AB 23.75AB 24.14AB 24.06AB 24.28AB 24.77AB 23.90AB 23 . 8 7 AB 24 . 0 3 AB 24 . 0 4 AB 24 . 0 0 AB 24.04AB 24.03AB 23 . 9 6 AB 23.93AB 23 . 8 9 AB 23 . 9 1 AB 23.89AB 23.91AB 23 . 9 2 AB 23 . 8 6 AB 23.92AB 23 . 8 7 AB 23 . 7 5 AB 23 . 5 8 AB 23 . 2 4 AB 23.20AB 23.16AB 23.31AB 23 . 4 0 AB 23 . 6 7 AB 23 . 0 2 AB 22 . 2 8 AB 23.25AB 23.57AB 23.34AB 23.53AB 23.35AB 23.18AB 23.31AB 23.20AB 23 . 3 4 AB 23.25AB 23 . 0 5 AB 22 . 9 3 AB 22.54AB 22.16AB 21.71AB21.84AB 23.09AB 22.99AB 22.73AB 22 . 9 5 AB 23 . 0 6 AB 23 . 5 5 AB 23.34AB 23.59 AB 23.55 AB 23.54 AB 23.60 AB 23.59 AB 23.60 AB 23 . 6 5 AB 23.67AB 23 . 9 2 AB 24 . 4 3 AB 23 . 9 2 AB FFE=25.88 FFE=26.35 FFE=26.36 FFE=26.38 FFE=25.36 FFE=25.33 23.63AB 23.56AB 23.56AB 23.00AB 23.04AB 24 . 6 3 AB 24.67AB 24.72AB 23.93AB 22 . 2 6 AB22 . 2 5 AB22 . 3 1 AB22 . 3 3 AB {\Farchitxt|c0;AS-BUILT SIDEWALK} 24 . 1 8 AB 24 . 6 9 AB 25 . 9 3 AB 24.69 AB 24 . 6 3 AB 25.87 AB 24 . 6 3 AB 25.86AB 24.93AB 24.85 AB 24.80AB 24.72AB 25.90AB 25 . 3 3 AB 25.34AB 25 . 9 2 AB 25.30AB25 . 8 7 AB 25 . 2 4 AB 25 . 1 4 AB25 . 1 2 AB 25.15AB 25.00AB 24.99AB 24.88AB 24 . 8 2 AB 24.61AB 24 . 5 8 AB 21.67AB 24.95AB 25.12AB 25 . 0 0 AB 24 . 9 4 AB 24 . 9 0 AB 24 . 8 8 AB24 . 9 6 AB 24 . 8 5 AB 24.83AB24 . 5 6 AB 25 . 8 9 AB 25.29AB 25.84 AB 25 . 2 5 AB 25 . 2 8 AB 25 . 8 6 AB 25.24 AB 25.83 AB 25.84AB 25 . 2 5 AB 25.34AB 25 . 9 1 AB25 . 3 9 AB 24 . 9 1 AB 24 . 9 0 AB 24 . 9 2 AB 23.94AB 25.30AB 25.94AB 25 . 9 0 AB 23.18AB 23 . 1 5 AB 23.12AB 23.13AB 23.00AB 25.76AB 25.85AB 24 . 9 0 AB 24.44AB 23.92AB 24 . 8 3 24.90 24.8325 . 7 7 24 . 8 3 24.95 24 . 8 6 25.12 24.52 24 . 8 6 24.73 24 . 2 8 25.77 24.87 25 . 8 0 25.00 25.8525.71 25 . 7 3 25 . 0 8 25.28 25.5424.43 24 . 1 4 25 . 2 6 25.7725.70 25.87 25.64 25.92 25.90 25.89 22.76 22.70 22 . 8 4 22.41 25 . 5 6 25.59 25.60 25.57 25 . 7 5 22.50 22.84 25.66 25.64 25.66 25 . 7 3 25.79 25 . 9 0 25 . 9 1 25 . 8 8 21.20 No . Re v i s i o n s : By : Da t e : RE V I E W E D B Y : R. C u r t i s s DE S I G N E D B Y : DR A W N B Y : SC A L E : DA T E : No v e m b e r 2 , 2 0 1 5 PR O J E C T : 10 2 2 - 0 0 1 Sheet Of 17 Sheets LA N D M A R K R E S I D E N C E S O N M O U N T A I N A V E N U E DR A W I N G F I L E N A M E : D : ro j e c t s \ 1 0 2 2 - 0 0 1 \ D w g \ R e c o r d D r a w i n g s \ 1 0 2 2 - 0 0 1 _ G R A D _ A B . d w g L A Y O U T N A M E : G 1 D A T E : O c t 2 5 , 2 0 1 7 - 8 : 5 0 a m C A D O P E R A T O R : f r e d LI S T O F X R E F S : [ 1 0 2 2 - 0 0 1 _ x T o p o ] [ 1 0 2 2 - 0 0 1 _ x E x s t ] [ 1 0 2 2 - 0 0 1 _ x P g r a d ] [ 1 0 2 2 - 0 0 1 _ x P u t i l ] [ 1 0 2 2 - 0 0 1 _ x S i t e ] [ N E S - x b o r d e r ] [ 1 0 2 2 - 0 0 1 P r o p s o e d ] [ 1 0 2 2 - 0 0 1 S t r e e t s ] [ 1 0 2 2 - 0 0 1 _ G r a d i n g _ A s - b u i l t s 2 ] [ 1 0 2 2 - 0 0 1 _ U t i l i t y _ A s - b u i l t s ] Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . 30 1 N o r t h H o w e s S t r e e t , S u i t e 0 1 0 Fo r t C o l l i n s , C o l o r a d o 8 0 5 2 1 E N G I N E E R N G I E H T R O N R N PH O N E : 9 7 0 . 2 2 1 . 4 1 5 8 F A X : 9 7 0 . 2 2 1 . 4 1 5 9 ww w . n o r t h e r n e n g i n e e r i n g . c o m C3.00 GR A D I N G P L A N C. S n o w d o n A. B o e s e 1" = 1 0 ' LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROPOSED BARRIER CURB PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES NOTES: 2.0%%% PEDESTRIAN ACCESS RAMPS (47.45)EXISTING SPOT ELEVATION PROPOSED VERTICAL CURB & GUTTER PROPOSED ELECTRIC TRANSFORMER EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R ( IN FEET ) 1 inch = ft. Feet01010 10 20 30 PROPOSED LOT LINE 1 RE V I S E D M I N . O P E N I N G E L E V A T I O N S - L O T S 7 - 1 0 CN S 03 . 3 0 . 1 6 RECO R D D R A W I N GTHESE RECORD DRAWINGS, PRODUCED BY NORTHERN ENGINEERINGSERVICES, INC., ARE BASED ON FIELD INFORMATION GATHERED BYOTHERS. NORTHERN ENGINEERING SERVICES, INC. ASSUMES NOLIABILITY FOR THE ACCURACY OF THIS FIELD INFORMATION. 2 RE C O R D D R A W I N G S FS W 10 / 2 5 / 1 7 W X X X X XXX XX VAULT CABLE X X UD DENEK JASON T/ CHISTINE D 9852 CLAIRTON PL LITTLETON, CO 80126 N. S H I E L D S S T . (6 0 ' R O W ) FRARE BARBARA L 1016 W. MOUNTAIN AVE. FORT COLLINS, CO 80521 CALLAWAY JEFFERY RYAN EDWARDS-CALAWAY LILY NOWELL 112 N. SSHIELDS ST. FORT COLLINS, CO 80521 CHILDRENS HOUSE MONTESSORI SCHOOL LLC 113 N. SHIELDS ST. FORT COLLINS, CO 80521 PUBLIC ALLEY 19' EOC-FL 31" ROLLOVER CURB & GUTTER 1' THICKENED EDGE 13' EOC-FL R9'R9' PROPOSED STORM DRAIN SEE SHEET C2.01 EXISTING DRIVE WAY 19' EOC-FL \A1;19' EOC-FL CONCRETE PAVEMENT JOINTS (TYP.) EXISTING SIBERIAN ELM (SEE TREE PROTECTION NOTES) 5015 5020 5025 5030 5035 5040 5015 5020 5025 5030 5035 5040 9+50 10+00 11+00 12+00 12+50 EXISTING GROUND PROPOSED GRADE 50 2 2 . 6 7 50 2 2 . 7 2 50 2 2 . 5 5 50 2 2 . 2 5 50 2 2 . 0 1 50 2 1 . 8 4 PV I S T A = 1 0 + 0 0 . 5 0 PV I E L E V = 5 0 2 2 . 4 1 PV I S T A = 1 1 + 7 1 . 9 1 PV I E L E V = 5 0 2 1 . 7 4 PV I S T A = 1 1 + 0 8 . 4 2 PV I E L E V = 5 0 2 2 . 1 5 PV I S T A = 1 1 + 3 9 . 8 0 PV I E L E V = 5 0 2 1 . 9 0 75.0' VC HP ELEV = 5022.73 HP STA = 10+43.03 PVI STA = 10+38.83 PVI ELEV = 5022.98 BV C S : 1 0 + 0 1 . 3 3 BV C E : 5 0 2 2 . 4 2 EV C S : 1 0 + 7 6 . 3 3 EV C E : 5 0 2 2 . 5 3 A.D. = 2.70 K = 27.80 PROPOSED GRADE EXISTING GROUND 1.50% -0.50% -1.20%-0.80% No . Re v i s i o n s : By : Da t e : RE V I E W E D B Y : R. C u r t i s s DE S I G N E D B Y : DR A W N B Y : SC A L E : DA T E : No v e m b e r 2 , 2 0 1 5 PR O J E C T : 10 2 2 - 0 0 1 Sheet Of 17 Sheets LA N D M A R K R E S I D E N C E S O N M O U N T A I N A V E N U E DR A W I N G F I L E N A M E : D : ro j e c t s \ 1 0 2 2 - 0 0 1 \ D w g \ R e c o r d D r a w i n g s \ 1 0 2 2 - 0 0 1 _ P U B L I C A L L E Y _ A B . d w g L A Y O U T N A M E : C 4 . 0 0 D A T E : O c t 2 5 , 2 0 1 7 - 8 : 5 9 a m C A D O P E R A T O R : f r e d LI S T O F X R E F S : [ 1 0 2 2 - 0 0 1 _ x E x s t ] [ 1 0 2 2 - 0 0 1 _ x P u t i l ] [ 1 0 2 2 - 0 0 1 _ x S i t e ] [ N E S - x b o r d e r ] [ 1 0 2 2 - 0 0 1 S t r e e t s ] [ 1 0 2 2 - 0 0 1 _ G r a d i n g _ A s - b u i l t s ] Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . 30 1 N o r t h H o w e s S t r e e t , S u i t e 0 1 0 Fo r t C o l l i n s , C o l o r a d o 8 0 5 2 1 E N G I N E E R N G I E H T R O N R N PH O N E : 9 7 0 . 2 2 1 . 4 1 5 8 F A X : 9 7 0 . 2 2 1 . 4 1 5 9 ww w . n o r t h e r n e n g i n e e r i n g . c o m C4.00 RO A D W A Y P L A N & P R O F I L E PU B L I C A L L E Y C. S n o w d o n A. B o e s e 1" = 2 0 ' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R DateCity Engineer Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER EXISTING EDGE OF ASPHALT ST PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE RIGHT FLOWLINE PUBLIC ALLEY SCALE : 1" = 20' (H) 1" = 5' (V) ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 TREE PROTECTION NOTES: 1.PAVING SHOULD NOT BE CLOSER THAN 5 FEET FROM THE OUTER BARK OF THE TREE. 2.EXCAVATION SHOULD BE NO MORE THAN 6 INCHES DEEP (FROM EXISTING GRADE) AT A DISTANCE OF 5 FEET FROM THE OUTER BARK OF THE TREE. 3.EXCAVATION SHOULD NOT BE GREATER THAN 12 INCHES DEEP (FROM EXISTING GRADE) AT A DISTANCE OF 8 FEET FROM THE OUTER BARK OF THIS TREE. 4.CONTRACTOR TO STAKE PROPOSED THICKENED EDGE WITH CUT AND FILL QUANTITIES AND MEET WITH THE CITY FORESTER AND ENGINEER ON SITE PRIOR TO CONSTRUCTION. RECO R D D R A W I N GTHESE RECORD DRAWINGS, PRODUCED BY NORTHERN ENGINEERINGSERVICES, INC., ARE BASED ON FIELD INFORMATION GATHERED BYOTHERS. NORTHERN ENGINEERING SERVICES, INC. ASSUMES NOLIABILITY FOR THE ACCURACY OF THIS FIELD INFORMATION. 2 RE C O R D D R A W I N G S MC R 10 / 2 5 / 1 7 12/15 Page 1 OVERALL SITE and DRAINAGE CERTIFICATION Commercial, Multi-Family and Subdivision Certification Form and Checklist Project Name: Date: Building Permit Numbers: (Commercial or multi-family) Per the requirement in Fort Collins Stormwater Criteria Manual (FCSCM) Volume 1, Section 6.11, please fill in all applicable items in this Certification Form for Commercial, Multi-Family and Overall Single Family sites. NOTE: several items must be verified during construction. A copy of the approved grading plan must be submitted with the as-built grading plan. (As-built elevations must be written in red next to the approved elevations.) •Use “Yes” for items completed as described. •Use “N/A” for items that are not applicable to the site being certified. •If any blanks are “No,” attach an explanation referencing the item number below. Attach an explanation or description of the as-built condition for any items listed or for anything not listed but shown on the approved construction plans. Provide an as-built redline or Mylar drawing with the following: I.Water Quality and Quantity Detention Basin Certification - FCSCM Vol.2, Ch.10 For multiple detention basins on a site, provide the following for each basin separately: A. Volume: As-built topographic verification is attached at 1-foot (or less) contour intervals and volume verification calculations for the water quality capture volume and the 100-year detention storage volume. 1. Detention basin topography was prepared by a professional land surveyor registered in the state of Colorado. 2.Both proposed and as-built contours are shown on the same plan sheet (dashed lines for proposed and solid lines for as-built). 3.All critical spot elevations as shown on the approved construction plans have been verified and the as-built elevations are shown on the plan sheet. 4.Stage-storage-discharge tables are provided on a separate document. 5.Verification that designed drain time is in compliance with Colorado Revised Statute § 37-92- 602(8) is attached and has been uploaded to the Statewide Compliance Portal (tinyurl.com/COCompliancePortal) for approval. Uploaded documents must include: a.The cover sheet from the approved drainage report b.The stamped certification page from the approved drainage report c.As-built topographic survey d.Stamped certification page from the Overall Site & Drainage Certification e.PDF output from the Stormwater Detention and Infiltration Design Data Speadsheet 12/15 Page 2 B.Water Quality and Quantity Detention Basin Grading: Attached is as-built verification that there is a minimum 2% positive fall into the concrete trickle pans or flow-line(s) from all areas in the bottom of the detention pond. If there is a “soft pan” in the flow-line, all areas still must meet the minimum 2% grade requirement. 1.Low Flow: Choose one of the following detention basin low flow options as applicable: a. Turf swale for low flow path in detention basin. There is a minimum 2% grade in the flow-line(s) of the detention basin. The flattest as-built grade is . b.Concrete pan for low flow in detention basin. There is a concrete pan installed that meets the grades as shown on the approved construction plans. (Show as-built spot elevations.) c.Soft pan for low flow in detention basin. •Verify and document the soft pan material gradation, trench width and depth - to be verified during construction by engineer. Picture documentation is preferred or engineer’s statement of visual inspection and compliance. (Choose one below.) o There is a soft pan with an underdrain installed that meets the design on the approved construction plans. (Show the underdrain grades, bedding material, geotextile, spot elevations, bends, cleanouts, etc.) o There is soft pan installed without an underdrain but there is a type A or B soil. The soil type must be documented by supplying verification from a registered professional geotechnical engineer. NOTE: Spot elevations are to be within 0.2 ft. +/-. 2. Side Slopes: The as-built side slopes of the detention basin have been calculated and are shown. Indicate the side slope with an arrow and a numerical value (e.g., 6.25:1). The maximum slope allowed is 4:1. Small areas of 3:1 may be acceptable, but slopes steeper than 3:1 must be stabilized or re- graded. Provide documentation if a variance was granted for steeper slopes during the design process. 3.Spillway Certification: The following items must be field verified: a.The location of the spillway is indicated on the as-built plan. b.The width of the spillway is indicated on the as-built plan. c.The elevation(s) of the spillway is shown on the as-built plan. d.A concrete ribbon defines the location and grade of the spillway. e.There is downstream scour protection in the spillway as per the construction plans. Indicate type: (riprap size “D50” gradation and bedding type, geotextile, buried riprap with inches of bury, etc.). f.There are no obstructions in the spillway, such as trees, bushes, sidewalks, landscape features, rocks, etc. 12/15 Page 3 4.Outlet Structure Certification a.The orifice plate for the approved release rate is installed with the correct size and location of the orifice. b.The orifice plate for the water quality outlet is installed with the correct hole size, number of rows and columns of holes. c.The bottom hole on both the water quality and quantity outlets are at the bottom of the plate so no water ponds in front of the plate. d.The well screen is the correct material and is installed as shown on the construction plans. e.100-year overflow grate elevation is . (Elev. A on detail D-46) f.The top elevation of the water quality capture volume is . (Elev. B on detail D-46) g.Overflow grate is made of the correct material, has the correct bar spacing, is hinged at the top and bolted at the bottom. h.The bottom of the outlet box has no obstructions or misalignments that will cause it to retain runoff water and is sloped at 2% towards outlet. II.Channels/Swales - FCSCM Vol.1, Ch.7, Sect.3&4 A. Capacity: The as-built capacity of all the major channels and swales has been verified. They meet or exceed capacity requirements shown in the approved drainage study for this project. 1.All swales are located within the drainage easements as shown on the construction plans. 2.Longitudinal slopes and side-slopes (cross-sections) have been verified. Design criteria requires longitudinal slopes of 2% min. (on vegetated swales) and side-slopes no steeper than 4:1. If these criteria are not met, the certification engineer will write a justification and propose mitigation for each instance or have the issues corrected. If variances to these criteria have previously been approved and are shown on the construction plans, no justification is needed. 3.As-built spot elevations on channels/swales are shown that correspond to spot elevations shown on the approved construction plans. 4.All permanent erosion control measures are installed as shown on the approved construction plans (e.g., drop structures, riprap, TRMs, etc.). (Include pictures and verification of the materials used as part of this verification.) 5.All pans, curbs, storm pipes or other appurtenances appropriately tie into each other in the system. (Pictures at tie-in points suggested.) 6.The minimum freeboard is provided for all channels and swales as shown on the approved construction plans or as identified in the approved drainage study. (Show the freeboard provided on the cross-sections as on the construction plan set or attached as separate documentation.) 7.The low flow portion of all channels or swales is clear of obstructions. (No landscaping, trees, shrubs, sod, etc. infringe on the low flow portion of channels or swales.) 12/15 Page 4 III.Storm Pipes (aka storm drains) - FCSCM Vol.1, Ch.6, Sec. 4 A. Storm Drain Pipe Capacity: The as-built capacity of all pipes installed on this project has been verified and meets or exceeds the capacity requirements shown in the approved drainage study for this project. 1.All storm drain pipe sizes and materials have been verified and are in conformance with the approved construction plans. (Indicate on the plan and profile sheets that they have been verified.) Material and size substitutions must be approved prior to installation. If a pipe size or material was changed during construction, the certification engineer must attach the approval documents or supply them with this certification. Approval documents must include a calculation documenting the capacity equivalency (equal or greater) of the substituted size. 2.The longitudinal slope of the pipe is as shown on the approved construction plans. The acceptable minimum slope is 0.4%. All slopes flatter than the designed slope on the construction plans must be justified with capacity calculations on an attached sheet. 3.The as-built invert elevations have been verified and are shown on the plan and profile sheets of the approved construction plans. B.Storm Drain Pipe Installation Requirements: All pipes are installed in accordance with the approved construction plans. 1.The minimum cover requirements for all pipes have been met as shown on the approved construction plans. These will be called out in critical locations. 2.All encasements and clearances as specified on the approved construction plans have been met. 3.Any specific joint types or construction methods specified on the approved construction plans have been met. (List on a separate sheet and attach to this certification.) IV.Concrete Pans - FCSCM Vol.1, Ch.7, Sec.4.1.3.4 A. Construction/Installation: All concrete pans have been constructed in accordance with the approved construction plans. 1.The concrete pans are the correct size/width as shown on the approved construction plans. 2.The longitudinal slopes of the pans are as shown on the approved construction plans. The certification engineer must justify or mitigate longitudinal slopes less than the minimum of 0.4% unless a flatter slope was approved and is shown on the approved construction plans. Provide mitigation or justification by separate document. 3.The cross-section of the pan is as shown on the construction plans. (Specifically, the pan cross- section is “V” shaped and meets the side slope shown on the detail.) 4.The concrete pans are a minimum of 6 inches thick without reinforcement and a minimum of 4 inches thick with a minimum of 6X6-W14xW14 reinforcement per detail D20B and D20C. (Provide documentation of the reinforcement used if different than shown on the details or on the approved construction plans.) 5.The spot elevations shown on the concrete pan(s) have been verified and are shown on the as- built drawings. 12/15 Page 5 V. Storm Drain Inlets - FCSCM Vol.1, Ch.6, Sec. 3 A. Construction/Installation: All storm drain inlets have been constructed in accordance with the approved construction plans. 1.The size and type of inlets are consistent with the inlets shown on the approved construction plan. Indicate by writing “Verified” on each inlet on the plan sheet or list on a separate document the inlet number(s), type and size (length). If the inlet installed is other than the one on the approved construction plan detail sheet, provide the name and source of the detail with justification for equal or better capacity. 2.The size of the inlet opening is consistent with the approved detail. (Check height and width.) 3.The elevation of the grate (if applicable) is at the elevation shown on the street profile or as indicated by a spot elevation on the construction plans. 4.The as-built invert elevations of all pipes entering and leaving the inlet are shown on the plan and profile sheets within construction tolerance of 0.2 feet. If substantially different, provide justification and capacity calculations to show the capacity is not affected or propose mitigation. 5.The as-built size of the inlet box is as shown on the construction plans or an explanation or justification is attached. 6.All inlet covers are stenciled or stamped with the following designation: NO DUMPING – DRAINS TO POUDRE RIVER. VI.Culverts - FCSCM Vol.2, Ch.9 A. Construction/Installation: All culverts have been constructed and/or installed in accordance with the approved construction plans. 1.All culvert sizes have been verified as indicated on the as-built construction plans as correct. 2.The culvert material type for all culverts installed is as on the approved construction plans and is indicated on the as-built plans. 3.The as-built invert “in and out” elevations have been verified and are indicated on the as-built construction plans. 4.The culvert headwalls or wing walls have been installed as shown on the approved construction plans. Headwalls or wing walls may be needed in the as-built conditions onsite if the slopes adjacent to the culvert are greater than 4:1. Please note areas needing stabilization in the certification narrative. An alternative to consider is a turf reinforcement mat (TRM). VII.Sub-Drains A. Construction/Installation: All sub-drains shown on the construction plans have been installed in accordance with those plans. Sub-drains installed with the sanitary sewer are to be verified on the sanitary sewer plan and profile sheets of the construction plans. (NOTE: Indicate any sub-drains installed after the plans were approved on the as-built plans.) 1.The size of the sub-drains are as approved on the construction plans and are indicated on the as- built plans. 2.The type of sub-drain, in particular the perforated and non-perforated sections of the drain, are as indicated on the approved construction plans. 12/15 Page 6 3.The cover requirements per the construction plans are provided. 4.The cleanouts have been installed at the locations shown on the construction plans and are accessible for cleaning. (Cleanouts can be buried a maximum of 6 inches deep with their locations marked.) 5.The backfill materials for sub-drains are as shown on the approved construction plans. (This includes the type, depth and width.) 6.The geo-textile liner completely wraps the sub-drain and the permeable backfill material unless shown otherwise on the approved construction plans. (Sub-drain pipe wrapped in a sock filter material is accepted only if approved prior to installation.) VIII.Curb Cuts A. Construction: All curb cut openings are constructed in accordance with the approved construction plans. 1.The size (width) of the curb cut opening is as shown on the approved construction plans. 2.The curb cut openings tie into a downstream swale, pipe, or other appurtenances with a smooth transition and there no obstructions such as riprap or sod impeding the flow downstream of the curb cut. IX.Sidewalk Culverts & Chases A. Construction/Installation: All sidewalk culverts have been installed at the locations shown on the approved construction plans. 1.The size (width and length) of the culverts are as shown on the approved construction plans. 2.The cover plate is a minimum 5/8-inch galvanized plate bolted to a galvanized angle iron per the detail shown on the approved construction plans or per the City’s detail. 3.The sidewalk culvert invert “in and out” elevations have been verified and are indicated on the as-built plans. 4.The sidewalk culvert opening is as shown on the approved construction plans or per the City’s detail. 5.There is a smooth transition both on the inlet and outlet ends of the sidewalk culvert with no obstructions such as riprap or sod impeding the flow into or out of the sidewalk culvert. X. Site Grading A. Construction: All common open spaces have been graded in accordance with the approved construction plans. 1.The grading on all common open spaces bordering private lots has been verified as correct and the as-built rear lot corner elevations have been shown on the as-built plans. 12/15 Page 7 2.The as-built contours for “overlot grading” are shown on the as-built construction plans for all common open spaces, tracts, outlots, etc. If not in compliance, please attach a narrative describing the situation for noncompliance and when it may be corrected. An escrow for overlot grading may be required. (NOTE: Residential Lot Grading Certification is a separate process from this Overall Site Certification. It is understood that residential lots will be brought to final grade once the foundation is backfilled so they may be lower than the plan shows at this Overall Site Certification stage.) 3.All turf reinforcement mats (TRMs) have been installed as shown on the approved construction plans and the slopes are stabilized. XI.Riprap - FCSCM Vol.1, Ch.7, Sec.4.4.4.3 A. Construction: All riprap has been installed in the locations and sizes indicated on the approved construction plans. XII.Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7 A. Construction: All fabric has been installed in the locations and sizes indicated on the approved construction plans. 1.All fabric was installed per the details on the approved construction plans. XIII.Post-Construction Site Cleanup - FCSCM Vol.3, Ch.7 A. Construction: All construction debris and obstructions of any kind have been removed from drainage paths. 1.All construction debris has been removed except in staging area(s). 2.All ruts have been smoothed out in all construction areas. 3.All areas needing reseeding have been identified and future stabilization goals have been coordinated with the Erosion Control Inspector and in accordance with FCSCM Vol.2 Chapter 12. Note the area needing stabilization in the narrative. XIV.Certification of Other Permanent BMPs - FCSCM Vol.2, Ch.8, Sec.2 & FCSCM Vol.2, Ch.12 A.The construction of channel drop structures is in accordance with the approved plan both in location, horizontal dimensions and cross-section. XV.Certification of LID and Water Quality Facilities - FCSCM Vol.3, Ch.4 A.Attached are the During Construction Inspection Checklist for Low Impact Development (LID) and other items to be verified during construction, along with pictures and other required documentation.