HomeMy WebLinkAboutLot Certifications - 04/11/2017Date: 4/05/2017 Subdivision: Kechter Farm Filing 1
Address: 6132 Spearmint Court
Permit Application #: B1604391
Fort Collins, CO 80528
Larimer County Parcel #: 8608421 019
Lot: 19 Block: 16
Larimer County Reception #: 20140024917 & 20150008527
(on development agreement)
I, (print) 71fr(QT1-t1 J.AM& 44ALDioP "a Colorado registered professional engineer, verify that construction
of all stormwater facilities and grading is complete and hereby submit this certification.
Please answer the following questions by initialingthe appropriate response. For each question initialed "No," attach an
explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots.
1.Certification includes attached Stormwater-a pp roved grading plan. (NOTE: City's No _____ Yes T14
Building Department does not approve grading plans).
2.Certification includes the attached as-built survey dated 4/05/2017 (must be within 60 No Yes TH
days of the date the certification is submitted) accurately and truthfully depicting
elevations for:
• lop of foundation/finished floor
• Finished grade on each side of the structure
• Quarter points along each lot line (not more than 50 feet apart)
• Breakpoints/high points
• Swales
• Berms
• Retainingwalls
• Air conditioning pads
• Windowwells
• Any other appurtenance(s) within an easement
3.All elevations are within a 0.2 foot tolerance of the approved grading plan. No 1"Mi Yes
4.The top of foundation is at least 6 inches above the highest grade surroundingthe No _____ Yes MH
structure.
5.There is minimum grade of 5%awayfromthe structure within the first 5to 10 feet No _____ Yes ITH
adjacent to the residence.
6.All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single No _____ Yes T.%
family lots when the swale is draining the runoff from only two adjoining properties)
and are not steeperthan 25% (4:1).
7.All flow lines of stormwater drainage swales are a minimum of 6 inches below the No _____ Yes 114
elevation of ground adjacent to the structure and will direct drainage as shown on the
Stormwater-approved grading plan.
8.All downspout locations and discharge directions are shown on the as-built survey. No _____ Yes T3's4
Runoff is directed into an appropriate drainage system or lot line swale, and it is not
directed onto neighboring properties.
5/26116 Page 1
9.As mooth transition with no vertical offset (step) in grade is provided at the lot line to all No ______ Yes
adjacent properties.
10.The grading of this lot does not adversely affect neighboring properties or City No _____ Yes T314
infrastructure.
11.Landscaping has been completed prior to survey. If not, please indicate who will be No 1 Yes
responsible for completing landscaping: 'ThLL F.4..J-r ( O-'.it&. jL&4C.
12.Final site cleanup has been completed. No Yes 1w
13.I personally visited the site as part of the certification process, and in my professional No ______ Yes T3l4
opinion, the as-built survey is an accurate representation of the site conditions.
14.Based on this information, I certify that (check one):
o The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached).
The elevations and drainage patterns of the lot/site as measured are in general conformance with the
City approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the
specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a
manner consistent with the approved drainage plan.
Name: 1TMO 17+ . MA 1-0 f, PC
Email: I £MJeeI'siJy.
Phone: ,e3
Company:
Address: Zo S. CL AeS., Sr3
to Li.i d ç 1 Co cis, .r
PE Stamp
Sign and date
NOTE:A complete certification must be submitted at least two weeks prior to a request fora Certificate of Occupancy
for the lot/site, including, but not limited to, drawings of the lot/site showing the approved design and as-built surveyed
elevations of all structures, drainage and grading features, written information/explanation of discrepancies, and other
information necessary to confirm the above certification to:
Email (preferred)
WaterUtilitiesEng@fcpov.com
Mailing Address
Fort Collins Utilities
ATTN: Water Utilities Engineering
281 North College Avenue
Fort Collins, CO 80521
Questions?
970-221-6700
City of
Fort Collins
5126116 Page 2
']•/ \ .—.p5. 2
16.9
CVRD 1 121.7
PATIO
22.1' / 0
DOWNSPOUT / I
"TYP"'
D
LOT 19, BLK 16 I LO
6132 SPEARMINT CT N- LOT 20
2 STORY WOOD AND STONE I BLOCK 16
T0F25.B co
'I)
23.92 11 '
Hc'J
GAS-
J ELEC
!
ZZ-bd 22.5
DRIy.._- J.
.5 5.50 '
t
1
It)
LOT 18
O1
BLOCK 16
?
DOWNSPOUT
RUN OUT
J-R ENGINEERING
A Subsidiary of Westrian
7200 S. Mon Way, Suite 0400. Centennial, CO 80112
303-740-9393 • Fax 303-721-9019 • wvjrengineering.com
DRAINAGE
JOB NUMBER 39713.01
CLIENTESE CONSULTANTS, INC.
SUBDIVISION KECHTER FARM
FILING _1 BLOCK 16 LOT _19
DATE 04/10/17 DRAWN BY KRW
CERTIFICATE
-—Q
UTILITIES
N
0
1
FENCE— \
S 00*1826 E \50.621
—r2 '—
EU 12 ir
- - - - B.0 U.DI -
• SETBACK ,
2 6 I
9• 23.74I 14 24.39 *
20 10 0 20
ORIGINAL SCALE: 1" = 20'
THE PROPERTY DESCRIBED AS: LOT 19, BLOCK 16, KECHTER FARM, CITY OF FORT COLLINS, COUNTY OF
LARIMER, STATE OF COLORADO; (PER CLIENT) ALSO KNOWN AS 6132 SPEARMINT COURT.
DRAINAGE CERTIFICATE
THE ELEVATIONS, SLOPES AND DRAINAGE PATTERNS DEPICTED ON THIS CERTIFICATE WERE DEVELOPED BY ESE
CONSULTANTS, INC., WHO PERFORMED A FIELD SURVEY OF THE PROPERTY ON APR. 05, 2017. THE ELEVATIONS
MAY CHANGE SUBSEQUENT TO THE SURVEY DUE TO SUBSIDENCE, UPHEAVAL, EROSION, ACTS OF MAN, AND/OR
OTHER FACTORS. THEREFORE, THIS CERTIFICATE MAY NOT ACCURATELY DEPICT THE ELEVATIONS AND
DRAINAGE PATTERNS AFTER THE DATE OF SURVEY AND INSPECTION. THE UNDERSIGNED, A REGISTERED
PROFESSIONAL ENGINEER, CERTIFIES THAT THEY HAVE INSPECTED THE SITE TO VERIFY THAT IT IS IN GENERAL
ACCORDANCE WITH THE SURVEY DATA AND CONCLUDES THAT THE LOT WILL DRAIN ADEQUATELY IN
CONFORMANCE WITH THE OVERALL SUBDIVISION DRAINAGE PLAN AND INDIVIDUAL LOT GRADING PLAN.
r A IIiF
r •s..
PREPARED UNDER MY DIRECT SUPERVISION
w09-5137
TIMOTHY JAMES HALOPOFF, P.E.
COLORADO LIC. PE NO. 37953 Y'ONA FOR AND ON BEHALF OF JR ENGINEERING, LLC. sss5
7200 South Alton Way, Suite C400
Centennial, CO 80112
303-740-9393 x Fax 303-921-7320
3930 Sinton Road, Suite 219
Colorado Springs, CO 80907
719-593-2593 x Fax 303-921-7320
X 2900 South College Avenue, Suite 3D
Fort Collins, CO 80525
970-491-9888 x Fax 303-921-7320
MEMORANDUM
To:City of Fort Collins, Bldg Dept.
From:Tim Halopoff, PE
Date:4-10-2017
Subject:6132 Spearmint Court, Lot 19, Blk 16 – Drainage Certificate Supplement
Certification of Lot Grading - Supplement
Item:
3.Not all elevations are within 0.2’ of the approved grading plans, but the drainage intent has been met
without impacts to adjoining properties.
11. It is industry standard to certify the grades prior to landscape installation. The landscaping was not
complete at time of survey.
This unofficial copy was downloaded on Dec-05-2014 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact Engineering Office 281 North College Fort Collins, CO 80521 USA