Loading...
HomeMy WebLinkAboutLot Certifications - 03/21/2019 (2)CERTIFICATION OF LOT GRADING Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e) Date: March 19,2019 Subdivision: FOX GROVE Address: 4445 HUNTSMAN DRIVE Permit Application #: BI803049 Larimer County Parcel #: 8715219052 Lot: Block: Larimer County Reception #: 20170030416 (on development agreement) I, (print) Dennis R. Messner a Colorado registered professional engineer, verify that construction of all stormwater facilities and grading is complete and hereby submit this certification. Please answer the following questions by initialing the appropriate response. For each question initialed "No," attach an explanation detailing how this wil l affect stormwater drainage for this lot and any adjacent lots. 1 . Certification includes attached Stormwater-approved grading plan. (NOTE: City's No Yes Building Department does not approve grading plans). 2. Certification includes the attached as-built survey dated °3/07/i9 (must be withi n 60 No Yes M^!^ days of the date the certification is submitted) accurately and truthfull y depicting elevations for: • Top of foundation/finished floor • Finished grade on each side of the structure • Quarter points along each lot line (not more than 50 feet apart) • Break points/high points • Swales • Berms • Retaining walls • Air conditioning pads • Window wells • Any other appurtenance(s) withi n an easement 3. Ail elevations are withi n a 0.2 foo t tolerance of the approved grading plan. No >(|iA>|^Yes structure. 4. The top of foundation is at least 6 inches above the highest grade surrounding the No Yes _j^^^^yj 5. There is a minimum grade of 5% away from the structure withi n the first 5 to 10 feet No _ adjacent to the residence. 6. All slopes meet or exceed the minimum requirement of 2% (1 % is acceptable on single No Yes family lots when the swale is draining the runoff from only two adjoining properties) and are not steeper than 33% (3:1). 7. All flow lines of stormwater drainage swales are a minimum of 6 inches below the No Yes elevation of ground adjacent to the structure and wil l direct drainage as shown on the * Stormwater-approved grading plan. 8. All downspout locations and discharge directions are shown on the as-built survey. No Yes Runoff is directed into an appropriate drainage system or lot line swale, and it is not directed onto neighboring properties. 2/14/17 Pagel Accepted 3/21/2019 WL 9. A smooth transition with no vertical offset (step) in grade is provided at the lot line to all No Yes adjacent properties. 10. The grading of this lot does not adversely affect neighboring properties or City infrastructure. 11 . Landscaping has been completed prior to survey. If not, please indicate who will be responsible for completing landscaping: 12. Final site cleanup has been completed. 13. I personally visited the site as part of the certification process, and in my professional opinion, the as-built survey is an accurate representation of the site conditions. 14. Based on this information, I certify that (check one): • The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). B The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a manner consistent with the approved drainage plan. NOTE: A complete certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, including, but not limited to, drawings of the lot/site showing the approved design and as-built surveyed elevations of all structures, drainage and grading features, written information/explanation of discrepancies, and other information necessary to confirm the above certification to: Email (preferred) Mailing Address Questions? WaterUtHitiesEngjSfcgov.com Fort Collins Utilities 970-221-6700 ATTN: Water Utilities Engineering 281 North College Avenue Fort Collins, CO 80521 Fort Collins utilities 2/14/17 Page 2 Certification of Lot Grading Lot 52, FOX GROVE Subdivision, City of Fort Collins, Larimer County, Colorado 4445 HUNTSMAN DRIVE, Fort Collins, CO 80524 Building Permit No.: B1803049 Explanation for Certification Item No. 3: The constructed spot elevations vary more and less than 0.2 foot of those depicted on the approved grading plan. Explanation for Certification Item No. 11: The landscaping has not been completed. The home owner is responsible to complete the landscaping. Explanation for Certification Item No. 12: The final clean up will be performed after completing the landscaping. This unofficial copy was downloaded on Jan-24-2018 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com For additional information or an official copy, please contact Engineering Office 281 North College Fort Collins, CO 80521 USA