HomeMy WebLinkAboutLot Certifications - 06/03/2019 (2)CERTIFICATION OF LOT GRADING
Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e)
Date: May 2 9 ^ 0 19 Subdivision: F OX G R O VE
Address: 4450 F OX G R O VE DRIVE Permit Application #: BI804416
Larimer County Parcel #: 8715219016
Lot: ^ Block: Larimer County Reception #: 20170030416
(on development agreement)
I, (print) Dennis R. Messner a Colorado registered professional engineer, verify that construction
of all stormwater facilities and grading is complete and hereby submit this certification.
Please answer the following questions by initialing the appropriate response. For each question initialed "No," attach an
explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots.
1 . Certification includes attached Stormwater-approved grading plan. (NOTE: City's No Yes A H ^ ^^
Building Department does not approve grading plans).
2. Certification includes the attached as-built survey dated °5/29/i9 (must be withi n 60 No Yes /sSiM
days of the date the certification is submitted) accurately and truthfull y depicting
elevations for:
• Top of foundation/finished floor
• Finished grade on each side of the structure
• Quarter points along each lot line (not more than 50 feet apart)
• Break points/high points
• Swales
• Berms I
• Retaining walls
• Air conditioning pads
Window wells
Any other appurtenance(s) withi n an easement
3. All elevations are withi n a 0.2 foo t tolerance of the approved grading plan. No/JfwYes
4. The top of foundation is at least 6 inches above the highest grade surrounding the No Yes j^C^
structure.
5. There is a minimum grade of 5% away from the structure withi n the first 5 to 10 feet No Yes f^^VLf
adjacent to the residence. |
6. All slopes meet or exceed the minimum requirement of 2% (1 % is acceptable on single No Yes/^/L^^^ii^
family lots when the swale is draining the runoff from only tw o adjoining properties)
and are not steeper than 33% (3:1).
7. All flow lines of stormwater drainage swales are a minimum of 6 inches below the No Yes jjj£_^
elevation of ground adjacent to the structure and wil l direct drainage as shown on the
Stormwater-approved grading plan.
8. All downspout locations and discharge directions are shown on the as-built survey. No Yes /J^'/^f
Runoff is directed into an appropriate drainage system or lot line swale, and it is not
directed onto neighboring properties.
2/14/17 Pagel
9. A smooth transition with no vertical offset (step) in grade is provided at the lot line to al
adjacent properties.
I
10. The grading of this lot does not adversely affect neighboring properties or City
infrastructure. ^
11 . Landscaping has been completed prior to survey. If not, please indicate who will be
responsible for completing landscaping: H O ME O W N ER
No Yes JM^l^
No Yes
A ^ f es
No
12. Final site cleanup has been completed.
13. I personally visited the site as part of the certification process, and in my professional No Yes
opinion, the as-built survey is an accurate representation of the site conditions.
14. Based on this information, I certify that (check one):
• The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached).
El The elevations and drainage patterns of the lot/site as measured are in general conformance with the
City approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the
specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a
manner consistent with the approved drainage plan.
PE Stamp
Sign and date
Name: Dennis R. Messner
Email: dennismessner45@gmail.com
Phone: 970-402-4360
Company: Dennis R. Messner, P. E.
Address: 2015 Buena Vista Place
Loveland, Colorado 80538
NOTE: A complete certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including, but not limited to , drawings of the lot/site showing the approved design and as-built surveyed
elevations of all structures, drainage and grading features, written information/explanation of discrepancies, and other
information necessary to confirm the above certification to:
Email (preferred)
WaterUtilitiesEng@fcgov.com
Mailing Address
Fort Collins Utilities
ATTN: Water Utilities Engineering
281 North College Avenue
Fort Collins, CO 80521
Questions?
970-221-6700
—City of
for t Collins utilities
2/14/17 Page 2
Certification of Lot Grading
Lot 16, Fox Grove Subdivision, City of Fort Collins, Larimer County, Colorado
4450 Fox Grove Dr., Fort Collins, CO 80524
Building Permit No.: B1804416
Explanation for Certification Item No. 3: The constructed spot elevations vary more and less than 0.2
foot of those depicted on the approved grading plan.
Explanation for Certification Item No. 11: The landscaping has not been completed. The home owner
is responsible to complete the landscaping.
Explanation for Certification Item No. 12: The final clean up will be performed after completing the
landscaping.
This unofficial copy was downloaded on Jan-24-2018 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com
For additional information or an official copy, please contact Engineering Office 281 North College Fort Collins, CO 80521 USA