Loading...
HomeMy WebLinkAboutSite Certifications - 11/20/2017Accepted 12/7/17 WL T T T X XXXXX SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST UD UD UD 10:1 41: 1 9:1 6:1 6:1 7:1 7:1 14: 1 10 : 1 22: 1 17:1 21:1 13:1 ARTHUR D R I V E SP R I N G C O U R T CO L L E G E A V E N U E 10 ' S I D E W A L K 10 ' S I D E W A L K PR O P O S E D S I D E W A L K EXISTING S I D E W A L K 6' S I D E W A L K 6' S I D E W A L K PROPOSED SIDEWALK PROPOSED PARKING LOT PROPOSED REMOTE DRIVE-THRU TELLER PROPOSED PARKING LOT 8' 17' TYP. 2.0% 2.0% 2.0% 2.0% 2.1 % 1.5 % 1.5% 2.1% 2.0% 2.7%2.0% 2.0 % 2.0 % 3.0% 3.1% 2.2% 2.9% 2.6% 2.0% 2.1% 2.5 % 5.0% 446 SQ. FT. OF DIRECT RUNOFF OVER PEDESTRIAN WALKWAY 17.00 1.5% 1.9% 2.2% 3.3% 2.3% 2.8% 2.1 % 2.6 % 2.3 % 2.7% 9.9% 6.0% 2.2% EXISTING FEMA FLOODPLAIN RETAINING WALL (BY OTHERS) SIDEWALK CHASE TRENCH DRAIN INCREASED FOUNDATION EXPOSURE (SEE NOTE 8) EXTENDED FOUNDATION HEIGHT (SEE NOTE 8) RETAINING WALL (BY OTHERS) RETAINING WALL BY OTHERS 2' CURB CHASE 2' CONCRETE PAN PROPOSED 18" VERTICAL CURB AND GUTTER CONCRETE CHASE 18" VERTICAL CURB AND GUTTER TIE TO EXISTING TIE TO EXISTING EXISTING 30" VERTICAL CURB AND GUTTER FLUSH CURB EXISTING 30" VERTICAL CURB AND GUTTER 18" VERTICAL CURB AND GUTTER RAMP MID BLOCK RAMP RAISED PLANTER (REFER TO LANDSCAPE PLANS FOR DETAILS) RAISED PLANTER (REFER TO LANDSCAPE PLANS FOR DETAILS) 30" VERTICAL CURB AND GUTTER TRASH ENCLOSURE TAPER 30" VERTICAL CURB AND GUTTER TO EXISTING 2' CONCRETE PAN RAMP RAMP RAMP RAMP 18" VERTICAL CURB AND GUTTER STOP SIGN BIKE RACK TRENCH DRAIN 21.1% 23.1% 12.5% 11.0% SW A L E (S E E S H E E T C6 . 0 5 ) SW A L E (S E E S H E E T C6 . 0 5 ) 93.1 8 92. 2 3 92.0 4 (92 . 2 7 ) (91 . 4 6 ) 93.1 7 94 . 0 6 94.41 94.7 8 94.2 7 93.8 6 93.8 0 93. 7 1 93.8 7 94.1 9 93.62 93.29 93.30 93.1 1 93.0 5 92. 9 9 92.5 1 91.9 0 92 . 2 7 92. 3 4 92.6 9 93.0 6 92.99 (92 . 2 0 ) 92. 8 3 93.6 0 94.04 94.2 2 93.8 7 94.6 2 94.6 2 94. 4 1 94. 3 4 94.3 3 94.2 3 94.3 6 93.5 1 93. 7 9 93.8 7 93.7993.78 93.3 0 92.5 2 93.1 3 93.58 93.50 93. 2 2 92.5 1 92.5 8 92.3 2 92.4 0 (97 . 0 9 ) 95.8 3 94.3 0 93.8 0 95.2 0 95.2 0 95 . 2 0TO W 89 . 6 5 BO W 95.10 TOW 86 . 0 2 BO W 86.9 9BOW 86 . 6 1 BO W 93.36 TOW 93.17 94 . 1 1 TO W 92.5 0 TOW 90.23 BOW 91 . 9 8 TO W 91.90 BOW (95 . 7 1 ) FFE=95.35 94.9 2 94.8 6 95.0 5 94.7 2 94.4 0 95.0 2 (9 5 . 2 5 ) 95.1 5 94.62 94.3 4 93.46 96.3 3 97.3 4 97.3 3 97.3 4 (93 . 2 7 ) (88 . 8 6 ) (88 . 6 5 ) (85 . 8 7 ) (85 . 4 4 ) 97.34 96 . 7 0 95.9 6 96 . 1 6 96.5 1 96.16 95 . 7 8 95 . 6 5 95.0 2 94.43 93.9 4 96 . 0 0 93.8 9 87.59 BOW 93.73 93.74 (95 . 0 5 ) 92 . 3 2 96.50 (95.5 9 ) (96 . 8 0 ) 94.95 95.24 95.24 95.25 94.6 0 HP 94.1 8 HP 92.9 3 92.62 94.28 92.9 7 95.31 95.34 95.32 95.35 95.4 1 87. 0 3 85.84  95.12 95.12 94.62 93.25 92.6 5 93.06 95.3 5 95.1 5 94 . 6 5 94.5 1 94. 5 6 95. 2 3 95. 2 3 94. 7 4 94. 7 4 95. 2 3 95.23 95. 3 4 93.10 96. 2 5 95. 4 2 96. 0 2 96. 2 9 95.2 3 95.35 96. 1 6 94. 8 0 95. 3 5 95. 3 5 95. 3 5 93. 7 4 93. 2 6 92. 7 7 91. 9 4 92. 4 6 92. 2 1 92. 0 1 92. 1 1 92. 3 1 91. 9 2 94. 9 7 95. 2 2 94. 3 7 93. 1 2 (96 . 8 2 ) (96 . 7 9 ) 96.47 96.29 95.87 (96.04) 94.80 94 . 9 8 95.0 2 95.2 6 94. 8 4 94.9 4 94.9 8 93.6 9 96.11 90. 4 8 TO W 90 . 1 0 BO W 86.03 86.05 86.12 86.14 87.8 7 88.45 87.54 87.84 88.16 94.89 95.0 2 95 . 0 3 95.03 95.14 95.2 0 95 . 4 3 94.54  94 . 4 6  95.00 95.0 3 95.6 2 T T T T T 95.00 93.07 (92 . 7 5 ) 92.91 93.00 93.1 7 92. 9 0 92.82 93.87 93.90 93.81 94.47 94.11 (94 . 2 3 ) (94 . 7 2 ) (92 . 3 0 ) 95.89 96 . 1 9 96.1 5 96.21 96.12 96 . 1 6 95.92 95.1195.23 95.26 95.3 3 95. 1 0 95.10 94. 1 9 94.05 93.60 92.26 96.59 96.50 96.59 97 . 0 1 97 . 0 8 CONCRETE STEP FLUSH CONCRETE (96.5 9 ) (9 1 . 2 0 ) (9 0 . 9 7 ) (88.42) (9 1 . 8 1 ) 3.1 % 2.2 % 11.0% 13.9% 7.0% 4.3% 94.3 3 94.2 9 EXISTING FEMA FLOODPLAIN EXISTING FEMA FLOODPLAIN 94.62 92.7 2 2.0% 1.0% 1. 1 % 3. 4 % CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C4.00 GR A D I N G P L A N 02.13.17 Sheet of 17 EL E V A T I O N S C R E D I T U N I O N DR A W I N G F I L E N A M E : D : \ P r o j e c t s \ 2 0 7 - 0 1 6 \ D w g \ R e c o r d D r a w i n g s \ 2 0 7 - 0 1 6 _ G R A D _ A B . d w g L A Y O U T N A M E : C 4 . 0 0 D A T E : D e c 0 5 , 2 0 1 7 - 1 0 : 4 9 p m C A D O P E R A T O R : c o d y LI S T O F X R E F S : [ N E S - x b o r d e r ] [ 2 0 7 - 0 1 6 _ x T o p o ] [ 2 0 7 - 0 1 6 _ x E x i s t ] [ 2 0 7 - 0 1 6 _ x P g r a d ] [ 2 0 7 - 0 1 6 _ x P u t i l ] [ 2 0 7 - 0 1 6 _ x S i t e ] [ 2 0 7 - 0 1 6 _ C 3 D _ P r o p o s e d ] [ 2 0 7 - 0 2 0 A s B u i l t _ S U R F A C E ] E N G I N E E R N G I E H T R O N R N 30 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 Fo r t C o l l i n s , C o l o r a d o 8 0 5 2 1 ww w . n o r t h e r n e n g i n e e r i n g . c o m Ph o n e : 9 7 0 . 2 2 1 . 4 1 5 8 NORTH ( IN FEET ) 1 inch = ft. Feet01010 10 20 30 LEGEND: PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5.EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 6.THE CONTRACTOR IS RESPONSIBLE FOR FIELD LOCATING AND VERIFYING ELEVATIONS OF ALL CURBS AND GUTTERS AT THE POINTS OF CONNECTION SHOWN ON THE PLANS PRIOR TO INSTALLING ANY OF THE NEW IMPROVEMENTS. IF A CONFLICT EXISTS AND/OR A DESIGN MODIFICATION IS REQUIRED, THE CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. 7.ADD 4900-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS, WHERE TRUNCATED. 8.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED ARCHITECTURAL AND LANDSCAPE ARCHITECTURE DRAWINGS FOR ALL STEPS, RAMPS, LANDSCAPING WALLS, SEATWALLS, AND PLANTERS. 9.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH STAMPED STRUCTURAL DRAWINGS FOR ELEVATIONS AND GRADE CONDITIONS ALONG BUILDING PERIMETER. NOTIFY OWNER, ARCHITECT, AND ENGINEER(S) OF ANY DISCREPANCIES PRIOR TO MOBILIZATION. NOTES: EXISTING SPOT ELEVATION PROPOSED STORM DRAIN PROPOSED INFLOW CURB AND GUTTER PROPOSED SWALE NORTHERN ENGINEERING SERVICE, INC. NE PROJECT # 1050-002 DATE: OCTOBER 2015 FIELD SURVEY BY: FINISHED GRADE AT HIGH SIDE OF WALL FINISHED GRADE AT LOW SIDE OF WALL TRANSITION CURB AND GUTTER T PROPOSED OUTFALL CURB AND GUTTER 6 REC O R D D R A W I N G S S W W W W W W W W W W W W G G G G G G G G G G G G G G G E E E E E E E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G X XXXXX W W W W W W W W G G G G G G G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ARTHUR D R I V E SP R I N G C O U R T TIE TO EX. 8" WATER w/ 8"x6" SWIVEL TEE, W/ 6" GV (NE) & T.B. N:121560.97 E:194527.43 SP R I N G C O U R T CONNECT TO EXISTING SANITARY SERVICE & INSTALL CLEAN OUT (SEE NOTE 10) N:121572.93 E:194615.21 ±7.41 LF 6" F.S. PROPOSED FIRE HYDRANT ASSEMBLY N:121563.98 E:194534.20 EXISTING SSMH TO BE ADJUSTED TO FINISH GRADE INV. OUT=4981.37(N) PROPOSED RETAINING WALL FEMA REGULATED FLOOD FRINGE EXISTING 8" SANITARY SEWER EXISTING 6" SANITARY SEWER EXISTING 6" WATER EXISTING WATER LINE EASEMENT EXISTING GAS LINE EXISTING SANITARY MAN HOLE RIM=4991.51 INV IN=4981.84 (E) INV IN=4984.16 (W) INV IN=4980.99 (S) INV OUT=4980.91 (N) APPROXIMATE LOCATION EXISTING SANITARY SEWER CLEAN OUT APPROXIMATE LOCATION OF EXISTING SANITARY SEWER SERVICE FEMA REGULATED FLOOD FRINGE PROPOSED RETAINING WALL EXISTING GAS LINE PROPOSED ELECTRIC SERVICE PROPOSED ELECTRIC METER TRANSFORMER CONNECT EXISTING ELECTRIC LINE PER CITY LIGHT & POWER RELOCATED ELECTRIC VAULT EXISTING 6" WATER FEMA REGULATED FLOOD FRINGE FEMA REGULATED FLOOD FRINGE TRENCH DRAIN 2' SIDEWALK CHASE PROPOSED GAS METER E PROPOSED BUILDING S I D E W A L K PR O P O S E D S I D E W A L K PR O P O S E D S I D E W A L K EXISTING S I D E W A L K PROPOSED SIDEWALK CONNECT TO EXISTING GAS MAIN PER UTILITY COMPANY'S SPECIFICATIONS CO L L E G E A V E N U E ±26.54 LF 4" S.S. @ 2.00% OUTFALL A1 INV. IN=4987.03 (E) FG=4987.03 FLOW CONTROL MH A3 INV. IN=4988.52 (S) INV. IN=4988.52 (E) INV. OUT=4988.11 (W) FG=4993.74 WATER QUALITY WEIR B3 INV. IN=4988.60 (W) INV. IN=4988.60 (S) INV. OUT=4988.60 (N) INV. OUT=4988.60 (E) FG=4993.60 3.13 LF 6" HDPE @ 2.00% 12" x 12" TEE B2 INV. IN=4988.61 (W) INV. OUT=4988.61 (N) INV. OUT=4988.61 (E) FG=4993.48 30.13 LF 12" HDPE @ 2.50% 35.43 LF 12" HDPE @ 1.00% 36.53 LF 12" HDPE @ 1.00% 19.83 L F 1 2 " H D P E @ 1 . 0 0 % 2' CONCRETE CHASE 6" SANITARY SEWER SERVICE 1-1/4" WATER SERVICE IS O L A T O R R O W INLET B1 INV. OUT=4988.69 (E) FG=4991.90 13.91 LF 6" HDPE @ 7.64% TRENCH END CAP A4-7 INV. IN=4993.41 (S) INV. OUT=4990.44 (NW) FG=4994.05 10' DRAINAGE EASEMENT EASEMENT FOR UNDERGROUND ELECTRIC LINE PER REC. NO. 87041082 IS O L A T O R R O W 30' SANITARY SEWER EASEMENT 15' UTILITY EASEMENT CITY SERVICE TO PUBLIC LIGHT PROPOSED CITY ELECTRIC LINE 12" x 6" TEE A2 INV. IN=4988.02 (E) INV. IN=4988.02 (S) INV. OUT=4988.02 (W) FG=4993.67 JUNCTION A5 INV. IN=4988.54 (E) INV. IN=4988.54 (S) INV. OUT=4988.54 (W) FG=4993.92 MONITORING WELL A2-1 INV. OUT=4988.09 (N) FG=4993.43 32 . 8 6 L F 6 " P E R F . H D P E @ 0 . 2 0 % 45° BEND A4-1 INV. IN=4988.62 (NE) INV. OUT=4988.62 (S) FG=4993.87 45° BEND W_ CLEANOUT A4-2 (TRAFFIC RATED) INV. IN=4989.37 (E) INV. OUT=4989.37 (SW) FG=4993.89 12'' x 6'' TEE A4-3 INV. IN=4989.73 (E) INV. IN=4989.73 (S) INV. OUT=4989.73 (W) FG=4994.15 45° BEND W_ CLEANOUT A4-4 (TRAFFIC RATED) INV. IN=4990.09 (SE) INV. OUT=4990.09 (W) FG=4994.28 ROOF LEADER A4-3.1 INV. OUT=4990.79 (N) FG=4995.35 ROOF LEADER B3-3 WITH A 6'' x 4'' TEE INV. OUT=4989.96 (W) FG=4996.14 9.57 LF 6" HDPE @ 2.00% BEND B3-2 INV. IN=4989.77 (E) INV. OUT=4989.77 (NW) FG=4995.09 39.25 LF 12" HDPE @ 0.20% WATER SERVICE TO BE LOWERED 18" BELOW STORM SEWER RELOCATED 3 4" WATER METER & CURB STOP EXISTING 3 4" WATER SERVICE TO REMAIN 3 4" WATER SERVICE 5' PAST METER. 5' PAST METER CONVERT TO 1-1/4" SERVICE (PER MEP RECOMMENDATION) 3.52 LF 12" HDPE @ 2.50% EXISTING GAS SERVICE EXISTING WATER SERVICE EXISTING GAS SERVICE TRENCH DRAIN 93.3 6 FG 93.6 4 FG 94.0 9 FG 93.9 3 FG 88.12 SG 88.02 SG 88.0 9 SG 88.1 8SG JUNCTION B4 INV. IN=4988.59 (W) INV. OUT=4988.59 (N) INV. OUT=4988.59 (E) FG=4993.70 55.2 0 L F 6 " H D P E @ 2 . 0 0 % BEND B3-1 INV. IN=4988.66 (SE) INV. OUT=4988.66 (N) FG=4993.58 EXISTING 30" RCP EASEMENT FOR SIDEWALK & ELECTRICAL ACCESS PER REC. NO. 807041080 TRENCH DRAIN 1.50 LF 6" PVC @ 0.50% TRENCH DRAIN A4-13 INV. IN=4994.93 (S) FG=4995.34 TRENCH DRAIN A4-14 INV. OUT=4994.94 (N) FG=4995.72 1.50 LF 6" PVC @ 0.50% TRENCH DRAIN A4-11 INV. IN=4994.51 (S) FG=4995.10TRENCH DRAIN A4-12 INV. OUT=4994.51 (N) FG=4995.04 TRENCH DRAIN A4-10 INV. OUT=4994.51 (N) FG=4995.10 1.51 LF 6" PVC @ 0.50% TRENCH DRAIN A4-9 INV. IN=4994.50 (S) FG=4994.96 TRENCH DRAIN A4-8 INV. OUT=4993.62 (N) FG=4994.19 SW A L E (S E E S H E E T C6 . 0 5 ) SW A L E (S E E S H E E T C6 . 0 5 ) JUNCTION B5 INV. IN=4988.58 (W) INV. OUT=4988.58 (N) FG=4993.81 3.38 LF 18" HDPE @ 2.50% INSPECTION PORT INSPECTION PORT 9' UTILITY EASEMENT PUBLIC ACCESS EASEMENT JUNCTION A6 INV. IN=4988.55 (S) INV. OUT=4988.55 (W) FG=4994.00 (16) SC-740 STORMTECH CHAMBERS WATER QUALITY WEIR A4 INV. IN=4988.53 (E) INV. IN=4988.53 (S) INV. IN=4988.53 (N) INV. OUT=4988.53 (W) FG=4993.85 9' UTILITY EASEMENT 8.5' UTILITY EASEMENT TRENCH DRAIN SANITARY SEWER MANHOLE EASEMENT POTENTIAL CONFLICT (SEE NOTE 13) POTENTIAL CONFLICT (SEE NOTE 13) HEADWALL (PER STRUCTURAL) 39.70 LF 18" HDPE @ 2.50% 5.25' LF W/ 6" VERTICAL EXTENSION W TEST STAHYD C.O. D C.O. C.O.C.O. D D C.O. C.O. ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST FF=4995.35 32.4' 2. 7 ' 33.9 ' G G EV E E E E E E E E E RD RD UD UD UD E E REC O R D D R A W I N G NORTH ( IN FEET ) 1 inch = ft. Feet01010 10 20 30 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C3.00 UT I L I T Y P L A N 02.13.17 Sheet of 17 EL E V A T I O N S C R E D I T U N I O N DR A W I N G F I L E N A M E : \ \ B R O N C O S \ E n g i n e e r s \ P r o j e c t s \ 2 0 7 - 0 1 6 \ D w g \ R e c o r d D r a w i n g s \ 2 0 7 - 0 1 6 _ U T I L - A B . d w g L A Y O U T N A M E : C 3 . 0 0 D A T E : N o v 2 2 , 2 0 1 7 - 8 : 4 7 a m C A D O P E R A T O R : m k u e h n e l LI S T O F X R E F S : [ 2 0 7 - 0 1 6 _ x E x i s t ] [ N E S - x b o r d e r ] [ 2 0 7 - 0 1 6 _ x S i t e ] [ 2 0 7 - 0 1 6 _ x P s u b g r a d ] [ 2 0 7 - 0 2 0 A s B u i l t _ U T I L I T I E S ] E N G I N E E R N G I E H T R O N R N 30 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 Fo r t C o l l i n s , C o l o r a d o 8 0 5 2 1 ww w . n o r t h e r n e n g i n e e r i n g . c o m Ph o n e : 9 7 0 . 2 2 1 . 4 1 5 8 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 9.REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 10.CONTRACTOR TO POTHOLE SANITARY SEWER SERVICE TO ESTABLISH CONNECTION INVERTS AND LOCATIONS. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION AND NOTIFY THE PLUMBING ENGINEER AND CIVIL ENGINEER OF ANY DISCREPANCIES. 11.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 12.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE SDR-35 OR APPROVED EQUAL. 13.CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 14.CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED PLUMBING DRAWINGS FOR WATER SERVICE ENTRY DETAIL. CONTRACTOR TO PROVIDE ADDITIONAL STAKING, IF NECESSARY. 15.CONTRACTOR TO COORDINATE ALL ROOF LEADERS WITH THE ARCHITECTURAL AND PLUMBING PLANS PRIOR TO CONSTRUCTION OR ORDERING OF MATERIAL. IF A CONFLICT EXISTS, CONTRACTOR TO CONTACT THE ENGINEER. EXISTING WATER MAIN LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED WATER SERVICE & CURB STOP PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT EASEMENT LINE PROPERTY BOUNDARY EXISTING LOTLINE APPROXIMATE GAS METER LOCATION W PROPOSED WATER MAIN PROPOSED SANITARY SEWER PROPOSED STORM SEWER APPROXIMATE ELECTRIC METER LOCATION ST UDPROPOSED UNDERDRAIN EXISTING STREET LIGHT GPROPOSED GAS EPROPOSED ELECTRIC FINISH GRADE SPOT ELEVATION ROOF DRAIN LOCATIONS PROPOSED SITE LIGHT RD SUBGRADE SPOT ELEVATION 5 1 RE C O R D D R A W I N G S BP M 04 . 1 7 . 1 7 2 RE C O R D D R A W I N G S MA K 08 . 2 2 . 1 7 3 RE C O R D D R A W I N G S MA K 11 . 1 3 . 1 7 3 3