HomeMy WebLinkAboutLot Certifications - 01/04/2021 (2)2/14/17 Page 1 CERTIFICATION OF LOT GRADING Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e) Date: Address: Lot: Block: Subdivision: Permit Application #: Larimer County Parcel #: Larimer County Reception #: (on development agreement) I, (print) , a Colorado registered professional engineer, verify that construction of all stormwater facilities and grading is complete and hereby submit this certification. Please answer the following questions by initialing the appropriate response. For each question initialed “No,” attach an explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots. 1.Certification includes attached Stormwater-approved grading plan. (NOTE: City’s Building Department does not approve grading plans). 2.Certification includes the attached as-built survey dated (must be within 60 days of the date the certification is submitted) accurately and truthfully depicting elevations for: Top of foundation/finished floor Finished grade on each side of the structure Quarter points along each lot line (not more than 50 feet apart) Break points/high points Swales Berms Retaining walls Air conditioning pads Window wells Any other appurtenance(s) within an easement 3.All elevations are within a 0.2 foot tolerance of the approved grading plan. 4.The top of foundation is at least 6 inches above the highest grade surrounding the structure. 5.There is a minimum grade of 5% away from the structure within the first 5 to 10 feet adjacent to the residence. 6.All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single family lots when the swale is draining the runoff from only two adjoining properties) and are not steeper than 33% (3:1). 7.All flow lines of stormwater drainage swales are a minimum of 6 inches below the elevation of ground adjacent to the structure and will direct drainage as shown on the Stormwater-approved grading plan. 8.All downspout locations and discharge directions are shown on the as-built survey. Runoff is directed into an appropriate drainage system or lot line swale, and it is not directed onto neighboring properties. No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes January 4, 2021 East Ridge Third Filing 402 Skyraider Way B2008254, B2008257, B2008256, B2008255, B2008253 Fort Collins, Colorado 8708165011, 8708165012, 8708165013, 8708165014, 8708165015 11, 12, 13, 14 and 15 Phase 1C | Block 2 20170085863, 20190031459 Herman Feissner 12.28.2020 HF HF HF HF Variations from 0.2 foot tolerance exist, see attached Plot Plan. HF As-built survey data is shown highlighted in BLUE on the attached Plot Plan. HF Downspout locations were observed and photographed during my site visit on December 28, 2020. The as-built condition is adequate. Refer to the ILC for the downspout locations. Air Conditioning (AC) pads were observed and photographed during my site visit on December 28, 2020. The AC pads (and downspout locations) are shown on the Improvement Location Certificate (ILC). HF HF SCALE: 1"=20' 0 10 20 Checked By: Project No: Drawn By: Date: 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 •GallowayUS.com 402 SKYRAIDER WAY, FORT COLLINS, CO LOTS 11-15, BLOCK 2, EAST RIDGE THIRD FILING CLIENT: HARTFORD HOMES CERTIFICATION OF LOT GRADING WBH HCF 12/28/20 SCALE: 1"=30' 0 15 30 HFH000019.10 WH RCR 03/31/20 402 Skyraider Way 402 Skyraider Way 4920 4925 4930 4935 4940 4945 4950 4955 4920 4925 4930 4935 4940 4945 4950 4955 69+0070+0071+0072+0073+0074+0075+0076+0077+0078+0079+0080+0080+50 23.71 LF - 18'' ADS @ 0.50% STA=77+15.01 INLET C11 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4946.51 INV IN (18" N)=4937.87 INV OUT (18" S)=4937.67 DEPTH=8.84 34.89 LF - 18'' ADS @ 0.50% 86.24 LF -15''ADS @ 0.50% STA=78+36.17 INLET C13 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.89 INV IN (15" N)=4938.93 INV OUT (15" S)=4938.73 DEPTH=7.16 28.42 LF - 15'' ADS @ 0.50% STA=78+64.55 INLET C14 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4947.63 INV IN (15" N)=4939.27 INV OUT (15" S)=4939.07 DEPTH=8.56 24.04 LF - 15'' ADS @ 0.50% STA=78+88.60 INLET C15 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4947.50 INV IN (15" N)=4939.59 INV OUT (15" S)=4939.39 DEPTH=8.11 34.89 LF - 15'' ADS @ 0.50% STA=70+08.50 EX INLET C2 15' CDOT TYPE R INLET RIM=4941.33 INV IN (36" N)=4934.01 INV OUT (36" S)=4934.01 DEPTH=7.32 23.83 LF - EXIST. 36'' RCP @ 0.20% STA=71+31.50 INLET C3 TRIPLE NO. 16 INLET RIM=4943.12 INV IN (24" N)=4934.25 INV OUT (36" S)=4934.25 DEPTH=8.87 47.01 LF - 24'' RCP @ 0.20% STA=71+78.51 SDMH C4 6'Ø MH RIM=4944.10 INV IN (24" E)=4934.35 INV OUT (24" S)=4934.35 DEPTH=9.76 67.00 LF -24''RCP @ 0.20% 125.65 LF -24''RCP @ 0.40% STA=90+00.00 (STORM C6) STA=74+21.13 STORM C SDMH C6 4'Ø MH RIM=4946.04 INV IN (18" W)=4935.68 INV IN (18" N)=4935.68 INV OUT (24" S)=4935.18 DEPTH=10.85 181.75 LF -18''RCP @ 0.40% STA=100+00.00 (STORM C7) STA=76+02.88 STORM C SDMH C7 4'Ø MH RIM=4945.78 INV IN (18" N)=4936.60 INV IN (15" S)=4936.85 INV OUT (18" E)=4936.40 DEPTH=9.37 STA=77+49.90 INLET C12 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.30 INV IN (15" N)=4938.30 INV OUT (18" S)=4938.05 DEPTH=7.25 STA=79+23.49 INLET C16 NYLOPLAST 15" DRAIN BASIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.89 INV OUT (15" S)=4939.77 DEPTH=6.12 PROPOSED GRADE EXISTING GROUND STA=76+26.59 INLET C8 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.32 INV IN (18" N)=4936.83 INV OUT (18" S)=4936.72 DEPTH=8.60 37.12 LF - 18'' ADS @ 0.50% STA=76+63.71 INLET C9 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.53 INV IN (18" N)=4937.22 INV OUT (18" S)=4937.02 DEPTH=8.51 27.25 LF - 18'' ADS @ 0.50% STA=76+90.96 INLET C10 NYLOPLAST 15" INLINE DRAIN W/ PEDESTRIAN GRATE INLET RIM=4946.63 INV IN (18" N)=4937.55 INV OUT (18" S)=4937.35 DEPTH=9.28 24.04 LF - 18'' ADS @ 0.50% 100 yr HGL 4' 49.97 LF - 24'' RCP @ 0.40% STA=80+00.00 (STORM C5A) STA=72+95.48 STORM C SDMH C5A 4'Ø MH RIM=4945.84 INV IN (18" E)=4935.18 INV IN (24" N)=4934.68 INV OUT (24" S)=4934.68 DEPTH=11.16 STA=72+45.51 SDMH C5 6'Ø MH RIM=4945.11 INV IN (24" N)=4934.48 INV OUT (24" W)=4934.48 DEPTH=10.63 99.17 LF -36''RCP @ 0.20% STA=70+32.33 TIE TO EXISTING C CONTRACTOR TO FIELD VERIFY LOCATION AND ELEVATION OF EXISTING STORM DRAIN STUB INV (36")=4934.06 4943.02 47.54 4934.20 4934.17 4943.99 4934.14 4934.19 0.04% 4943.99 4934.54 4934.49 71.22 0.48% 4945.59 4935.35 4934.81 4934.70 50.5 0.32% 4945.52 4935.69 4935.66 4935.22 0.33%124.8 4945.24 4945.28 4945.44 4946.74 4946.46 4945.79 4945.47 4947.36 4945.90 183.4 22.238.527.525.625.723.834.8 4945.58 4938.10 4937.90 89.29 0.44% 4938.67 4938.47 4939.78 4939.03 4938.77 1.32%0.80%0.39% 4937.86 4937.65 31.59 0.13%0.20%1.09% 4937.60 4937.44 0.49%0.54% 4937.14 4936.94 4936.75 4936.75 0.38% 4936.63 4936.83 4936.38 4939.32 4939.22 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 O www.gallowayUS.com C 2017. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\4-As Built\Site\HFHLV1.02_SD03_S_as-built-2.dwg - Kyle Pollock - 3/20/2019 HFHLV0001.02 11.10.2017 Init.#Issue / DescriptionDate EAST RIDGE THIRD FILING MON TAGE TOWNH OMES FORT COLLINS, CO THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. DateCity Engineer Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner SD05 JEP AGM ( IN FEET ) 1 inch = ft. 0 Feet5050 50 100 150 KEYMAP TIMBERLINE ROAD ROTATION: 90° STA: SCALE: H: 1"=V: 1"= toPRIVATE STORM DRAIN C 70+00.00 79+23.49 50 5 PROPOSED RIGHT-OF-WAY EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: T T T EXISTING STORM SEWER EXISTING GAS EXISTING TELEPHONE EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY E E EPROPOSED ELECTRIC GAS 8''W 8''SS 8''SS 8''W PROPOSED MANHOLE NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALL VERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEETS SS01-SS06 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE EXISTING CONDITIONS SHEETS FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE IN PAVED AREAS. SD05 AB 09/07/18 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING DATED: SEPTEMBER 7, 2018 49 4 6 . 0 6 49 4 7 . 4 6 49 4 7 . 6 4 49 4 5 . 9 0 AS-BUILT PER 12/28/2020 SURVEY (TYP.)