Loading...
HomeMy WebLinkAboutLot Certifications - 03/29/20192/14/17 Page 1 CERTIFICATION OF LOT GRADING Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e) Date: Address: Lot: Block: Subdivision: Permit Application #: Larimer County Parcel #: Larimer County Reception #: (on development agreement) I, (print) , a Colorado registered professional engineer, verify that construction of all stormwater facilities and grading is complete and hereby submit this certification. Please answer the following questions by initialing the appropriate response. For each question initialed “No,” attach an explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots. 1.Certification includes attached Stormwater-approved grading plan. (NOTE: City’s Building Department does not approve grading plans). 2.Certification includes the attached as-built survey dated (must be within 60 days of the date the certification is submitted) accurately and truthfully depicting elevations for: Top of foundation/finished floor Finished grade on each side of the structure Quarter points along each lot line (not more than 50 feet apart) Break points/high points Swales Berms Retaining walls Air conditioning pads Window wells Any other appurtenance(s) within an easement 3.All elevations are within a 0.2 foot tolerance of the approved grading plan. 4.The top of foundation is at least 6 inches above the highest grade surrounding the structure. 5.There is a minimum grade of 5% away from the structure within the first 5 to 10 feet adjacent to the residence. 6.All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single family lots when the swale is draining the runoff from only two adjoining properties) and are not steeper than 33% (3:1). 7.All flow lines of stormwater drainage swales are a minimum of 6 inches below the elevation of ground adjacent to the structure and will direct drainage as shown on the Stormwater-approved grading plan. 8.All downspout locations and discharge directions are shown on the as-built survey. Runoff is directed into an appropriate drainage system or lot line swale, and it is not directed onto neighboring properties. No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes Accepted 3/29/2019 WL B1802897-99, B1802901 LOT 23 LOT 24 LOT 9 LOT 10 LOT 8 LOT 7 LOT 6 LOT 5 LOT 27 LOT 6 LOT 1 LOT 8 LOT 7 LOT 26 LOT 25 LOT 4 LOT 3 LOT 2 LOT 1 LOT 28 LOT 29 LOT 30 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 14 LOT 15 LOT 16 LOT 22 LOT 21 LOT 20 LOT 19 LOT 18 LOT 17 LOT 16 LOT 15 BLOCK 1 BLOCK 4 BLOCK 2 BLOCK 2 BLOCK 3 COMET STREET (PRIVATE DRIVE) SKYRAIDER WAY (PRIVATE DRIVE) TIMBERLINE ROAD TRACT G TRACT I TRACT F LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22 LOT 23 LOT 24 LOT 36 LOT 37 LOT 38 LOT 39 LOT 40 LOT 41 LOT 42 LOT 43 LOT 44 LOT 45 LOT 46 LOT 47 LOT 48 LOT 49 LOT 50 LOT 51 LOT 52 BLOCK 2 BLOCK 2 BLOCK 2 BLOCK 2 BLOCK 2 BLOCK 2 BLOCK 2 TRACT H TRACT I TRACT F FF=4947.26 FF=4947.28 FF=4947.98 FF=4947.99 FF=4949.21 FF=4949.55 FF=4948.98 VICOT WAY 44 46 PROPOSED UTILITY PLANS FOR: EAST RIDGE SECOND FILING DATED: 6.30.16 4.4% 8.4% 13.6% 3.0% 3.6% 5.2% 4.4% 4.0% 14.3% 8.9% 5.3% 9.7% 8.2% 27.5% 4.4% 4.1% ACCESS EASEMENT 44.72 LP 47 46 1.5% 1.5% 48 47 48 47 3' WIDE SOFT BOTTOM PAN FOR DETAIL SEE SHEET DT06 45.49 46.43 46.94 47.20 47.83 46.00 47.42 47.32 46.76 47.58 47.28 47.50 46.65 47.79 47.43 46.91 46.11 46.77 47.13 47.46 47.67 45.4146.51 46.29 47.25 47.92 45.89 LP 46.51 LP 45.43 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 3 3 46.65 48.23 48.23 47.69 45.67 45.53 46.57 46.51 46.63 46.79 45.62 END 3' WIDE SOFT BOTTOM PAN START 3' WIDE SOFT BOTTOM PAN END 3' WIDE SOFT BOTTOM PAN 46.11 48 47 48 48 12.0% 8.0% 10.9% 0.8% 0.8% 0.7%FF=4949.51 4947.232 4947.351 4947.404 4947.438 4947.401 4947.387 4947.373 4947.202 4947.094 4947.329 4948.677 4949.345 4949.387 4949.504 4949.347 4949.512 4948.533 4947.768 4947.757 4947.154 4946.701 4947.829 4949.088 4947.7184947.687 4947.684 4949.120 4949.026 4949.517 4947.9784948.121 4946.960 4945.663 4945.635 4945.649 4945.690 4945.700 4945.751 4945.977 4946.270 4946.460 4946.545 4946.613 4946.5824946.509 4947.079 4948.672 4947.091 4946.673 4949.104 4949.051 4945.598 4945.272 4945.205 4945.198 4945.462 4945.630 4945.794 4946.057 4946.198 4946.441 4946.589 4946.762 4947.197 4947.308 4947.005 4947.299 4947.0854946.891 4947.3004947.137 4946.708 4947.3694947.123 4946.9614946.769 4946.626 4946.256 4946.114 4945.967 4945.641 4945.698 4947.353 4947.442 4947.429 4947.449 4947.3344947.334 4947.359 4947.334 4947.371 4947.4034947.391 4947.2864947.1984947.0864946.919 4946.855 4947.399 4947.4884947.508 4947.5054947.499 4947.619 4948.162 4948.623 4949.520 4947.502 4948.869 4949.3474949.429 4948.946 4948.151 4947.607 4947.435 4947.397 4947.429 4947.479 4947.514 4947.629 4949.034 4949.057 4947.886 4947.616 4947.489 4947.474 4947.528 4947.623 4949.088 4949.071 4947.767 4947.559 4947.446 4947.1804946.950 4946.989 4947.128 4949.251 4949.122 4947.059 4946.918 4946.324 4946.3264945.717 4946.129 4946.601 4946.878 4947.971 4947.866 4946.549 4946.607 4946.472 4946.515 4946.616 4948.100 4947.468 4947.508 4947.378 4948.022 4948.012 4947.924 4947.831 4947.805 4947.708 4947.412 4947.404 4947.416 4947.355 4947.913 4947.877 4947.914 4949.160 4949.328 4949.334 4949.285 4949.280 4949.233 4947.996 4947.994 4947.982 4948.041 4947.709 4947.725 4945.7954946.240 4946.281 4946.372 4946.424 4946.524 4946.570 4946.603 4946.627 4946.658 4946.591 4946.607 4946.107 4947.768 4947.644 4947.6244947.661 0.8% 47 46 47 48 49 49 48 48 48 47 49 48 8.0% 4.2%17.6% CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. DateCity Engineer Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP GR05 JEP NEW ( IN FEET ) 1 inch = ft. 0 Feet3030 30 60 90 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 O www.gallowayUS.com 2017. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\4-As Built\HFHLV1.02_GR03_S_AB-2019 CAD.dwg - Kyle Pollock - 3/26/2019 HFHLV0001.02 11.10.2017 Init.#Issue / DescriptionDate EAST RIDGE TH IR D FILING MON TAGE TOWNH OMES FORT COLLINS, CO THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED PAN EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATION. 2.REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION. 3.ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71). 4.CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET RIGHT-OF-WAY ARE FINISHED GRADE. 5.CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR LANDSCAPE AREAS. 6.4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED. 7.REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN. 8.FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE INDIVIDUAL FOOTPRINTS ARE DETERMINED. 9.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 10. SOFT BOTTOM PAN AND ASSOCIATED UNDERDRAIN REQUIRED FOR SWALES LESS THAN 2% SLOPE. 11. DRIVEWAY SLOPES RANGE FROM 2% TO 10%. PROPOSED STORM INLET 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) PROPOSED RIGHT OF WAY LEGEND:NOTES: LOT TEMPLATE A B 4550 50 NOTES FOR EXTERIOR ENTRY SIDEWALK STEPS 1. USE 5-1/2" RISERS AND/OR 7-1/2" RISERS AS NECESSARY 2. MAXIMUM RISER HEIGHT IS 7-1/2" 3. MINIMUM 5' LANDINGS BETWEEN DOUBLE OR SINGLE RISERS AS DEPICTED ON PLAN. 4. LANDINGS SHALL BE 2% MAXIMUM SLOPE. 5. 12" TREADS (TYPICAL) 6. FOR HANDRAIL REQUIREMENTS REFER TO ARCHITECTURAL DESIGN PLANS. NOTES GARAGE STEPS 3 - 6-1/2" RISERS 3 - 7-1/2" RISERS 4 - 6-3/4" RISERS 1 - 6-1/4" RISERS 3 - 6-3/4" RISERS 4 - 6-1/2" RISERS 1 2 3 4 5 6 MATCHLINE SEE SHEET GR06 MATCHLINE SEE SHEET GR04 GR01 GR02 GR03 GR05 GR06 GR04 GR07 AB 03.22.19 Record Drawings JEP 4947.757 REPRESENTS RECORD SURVEY DATA PROVIDED BY GALLOWAY DATED: MARCH 22, 2019 4947.757 REPRESENTS RECORD SURVEY DATA PROVIDED BY GALLOWAY DATED:MARCH 22,2019 4947.757 SCALE:1"=20' 0 10 20 4920 4925 4930 4935 4940 4945 4950 4955 4920 4925 4930 4935 4940 4945 4950 4955 69+0070+0071+0072+0073+0074+0075+0076+0077+0078+0079+0080+0080+50 23.71 LF - 18'' ADS @ 0.50% STA=77+15.01 INLET C11 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4946.51 INV IN (18" N)=4937.87 INV OUT (18" S)=4937.67 DEPTH=8.84 34.89 LF - 18'' ADS @ 0.50% 86.24 LF -15''ADS @ 0.50% STA=78+36.17 INLET C13 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.89 INV IN (15" N)=4938.93 INV OUT (15" S)=4938.73 DEPTH=7.16 28.42 LF - 15'' ADS @ 0.50% STA=78+64.55 INLET C14 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4947.63 INV IN (15" N)=4939.27 INV OUT (15" S)=4939.07 DEPTH=8.56 24.04 LF - 15'' ADS @ 0.50% STA=78+88.60 INLET C15 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4947.50 INV IN (15" N)=4939.59 INV OUT (15" S)=4939.39 DEPTH=8.11 34.89 LF - 15'' ADS @ 0.50% STA=70+08.50 EX INLET C2 15' CDOT TYPE R INLET RIM=4941.33 INV IN (36" N)=4934.01 INV OUT (36" S)=4934.01 DEPTH=7.32 23.83 LF - EXIST. 36'' RCP @ 0.20% STA=71+31.50 INLET C3 TRIPLE NO. 16 INLET RIM=4943.12 INV IN (24" N)=4934.25 INV OUT (36" S)=4934.25 DEPTH=8.87 47.01 LF - 24'' RCP @ 0.20% STA=71+78.51 SDMH C4 6'Ø MH RIM=4944.10 INV IN (24" E)=4934.35 INV OUT (24" S)=4934.35 DEPTH=9.76 67.00 LF -24''RCP @ 0.20% 125.65 LF -24''RCP @ 0.40% STA=90+00.00 (STORM C6) STA=74+21.13 STORM C SDMH C6 4'Ø MH RIM=4946.04 INV IN (18" W)=4935.68 INV IN (18" N)=4935.68 INV OUT (24" S)=4935.18 DEPTH=10.85 181.75 LF -18''RCP @ 0.40% STA=100+00.00 (STORM C7) STA=76+02.88 STORM C SDMH C7 4'Ø MH RIM=4945.78 INV IN (18" N)=4936.60 INV IN (15" S)=4936.85 INV OUT (18" E)=4936.40 DEPTH=9.37 STA=77+49.90 INLET C12 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.30 INV IN (15" N)=4938.30 INV OUT (18" S)=4938.05 DEPTH=7.25 STA=79+23.49 INLET C16 NYLOPLAST 15" DRAIN BASIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.89 INV OUT (15" S)=4939.77 DEPTH=6.12 PROPOSED GRADE EXISTING GROUND STA=76+26.59 INLET C8 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.32 INV IN (18" N)=4936.83 INV OUT (18" S)=4936.72 DEPTH=8.60 37.12 LF - 18'' ADS @ 0.50% STA=76+63.71 INLET C9 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.53 INV IN (18" N)=4937.22 INV OUT (18" S)=4937.02 DEPTH=8.51 27.25 LF - 18'' ADS @ 0.50% STA=76+90.96 INLET C10 NYLOPLAST 15" INLINE DRAIN W/ PEDESTRIAN GRATE INLET RIM=4946.63 INV IN (18" N)=4937.55 INV OUT (18" S)=4937.35 DEPTH=9.28 24.04 LF - 18'' ADS @ 0.50% 100 yr HGL 4' 49.97 LF - 24'' RCP @ 0.40% STA=80+00.00 (STORM C5A) STA=72+95.48 STORM C SDMH C5A 4'Ø MH RIM=4945.84 INV IN (18" E)=4935.18 INV IN (24" N)=4934.68 INV OUT (24" S)=4934.68 DEPTH=11.16 STA=72+45.51 SDMH C5 6'Ø MH RIM=4945.11 INV IN (24" N)=4934.48 INV OUT (24" W)=4934.48 DEPTH=10.63 99.17 LF -36''RCP @ 0.20% STA=70+32.33 TIE TO EXISTING C CONTRACTOR TO FIELD VERIFY LOCATION AND ELEVATION OF EXISTING STORM DRAIN STUB INV (36")=4934.06 4943.02 47.54 4934.20 4934.17 4943.99 4934.14 4934.19 0.04% 4943.99 4934.54 4934.49 71.22 0.48% 4945.59 4935.35 4934.81 4934.70 50.5 0.32% 4945.52 4935.69 4935.66 4935.22 0.33%124.8 4945.24 4945.28 4945.44 4946.74 4946.46 4945.79 4945.47 4947.36 4945.90 183.4 22.238.527.525.625.723.834.8 4945.58 4938.10 4937.90 89.29 0.44% 4938.67 4938.47 4939.78 4939.03 4938.77 1.32%0.80%0.39% 4937.86 4937.65 31.59 0.13%0.20%1.09% 4937.60 4937.44 0.49%0.54% 4937.14 4936.94 4936.75 4936.75 0.38% 4936.63 4936.83 4936.38 4939.32 4939.22 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 O www.gallowayUS.com C 2017. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\4-As Built\Site\HFHLV1.02_SD03_S_as-built-2.dwg - Kyle Pollock - 3/26/2019 HFHLV0001.02 11.10.2017 Init.#Issue / DescriptionDate EAST RIDGE TH IR D FILING MON TAGE TOWNH OMES FORT COLLINS, CO THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. DateCity Engineer Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner SD05 JEP AGM ( IN FEET ) 1 inch = ft. 0 Feet5050 50 100 150 KEYMAP TIMBERLINE ROAD ROTATION: 90° STA: SCALE: H: 1"=V: 1"= toPRIVATE STORM DRAIN C 70+00.00 79+23.49 50 5 PROPOSED RIGHT-OF-WAY EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: T T T EXISTING STORM SEWER EXISTING GAS EXISTING TELEPHONE EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY E E EPROPOSED ELECTRIC GAS 8''W 8''SS 8''SS 8''W PROPOSED MANHOLE NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALL VERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEETS SS01-SS06 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE EXISTING CONDITIONS SHEETS FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE IN PAVED AREAS. SD05 AB 09/07/18 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING DATED: SEPTEMBER 7, 2018 8''SS 8''SS 8''SS 8''W 8''W 8''W SS 8''SS 8''SS 8''SS 8''SS 8''W 8''W 8''W 8''SS 8''SS 8''SS 8''W 8''W 8''WSPIRIT LANE (PRIVATE DRIVE) WAY VE) TRACT F LOT 35 LOT 36 80+23.7780+00 INLET C5A.1 STA=80+23.77 CDOT TYPE C INLET N:17852.9688 E:10266.5463 18'' RCP 23.77 LF @ 0.40% SDMH C5A STA=80+00.00 STORM C5A STA=72+95.48 (STORM C) 4'Ø MH N:17853.2624 E:10242.7813 TRACT F SANITARY LINE 4.1 SEE SHEET SS06 4920 4925 4930 4935 4940 4945 4950 4955 4920 4925 4930 4935 4940 4945 4950 4955 79+50 80+00 81+00 PROPOSED GRADE EXISTING GROUND 23.77 LF - 18'' RCP @ 0.40% STA=80+23.77 INLET C5A.1 CDOT TYPE C INLET TBC=4943.15 INV OUT (18" W)=4935.28 DEPTH=7.87 STA=72+95.48 (STORM C) STA=80+00.00 STORM C5A SDMH C5A 4'Ø MH RIM=4945.84 INV IN (18" E)=4935.18 INV IN (24" N)=4934.68 INV OUT (24" S)=4934.68 DEPTH=11.16 100 yr HGL 4945.59 4935.35 4934.81 4934.70 4943.18 4935.18 23.2 -0.73% 4920 4925 4930 4935 4940 4945 4950 4955 4920 4925 4930 4935 4940 4945 4950 4955 89+5090+0091+0092+0092+50 STA=91+03.78 INLET C6.1 2' ROUND AREA INLET NEENAH R-2560-23 GRATE RIM=4946.52 INV IN (18" N)=4936.29 INV OUT (18" S)=4936.09 DEPTH=10.43 33.59 LF - 18'' RCP @ 0.40% STA=74+21.13 (STORM C) STA=90+00.00 STORM C6 SDMH C6 4'Ø MH RIM=4946.04 INV IN (18" W)=4935.68 INV IN (18" N)=4935.68 INV OUT (24" S)=4935.18 DEPTH=10.85 103.78 LF -18''RCP @ 0.40% STA=91+37.37 SDMH C6.2 4'Ø MH RIM=4946.92 INV IN (18" W)=4936.62 INV OUT (18" S)=4936.42 DEPTH=10.50 92.00 LF -18''RCP @ 0.40% STA=92+29.37 INLET C6.3 TRIPLE NO. 16 INLET RIM=4945.29 INV OUT (18" E)=4936.99 DEPTH=8.29 PROPOSED GRADE EXISTING GROUND 100 yr HGL HGL HGL HGL HGL 4945.52 4935.69 4935.66 4935.22 4946.50 4936.24 4936.04 106.34 0.36% 4946.73 4936.58 4936.38 31.90 0.44% 0.57%90.7 4945.18 4937.10 4920 4925 4930 4935 4940 4945 4950 4955 4920 4925 4930 4935 4940 4945 4950 4955 99+50 100+00 101+00 102+00 STA=101+26.09 INLET C7.4 NYLOPLAST 15" DRAIN BASIN W/ 15" PEDESTRIAN GRATE INLET RIM=4943.93 INV OUT (15" N)=4938.00 DEPTH=5.92 27.25 LF - 15'' ADS @ 0.50% STA=100+98.83 INLET C7.3 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.35 INV IN (15" S)=4937.87 INV OUT (15" N)=4937.75 DEPTH=7.61 24.04 LF - 15'' ADS @ 0.50% STA=100+74.79 INLET C7.2 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4945.43 INV IN (15" S)=4937.63 INV OUT (15" N)=4937.43 DEPTH=8.00 34.89 LF - 15'' ADS @ 0.50% STA=100+39.90 INLET C7.1 NYLOPLAST 15" INLINE DRAIN W/ 15" PEDESTRIAN GRATE INLET RIM=4944.06 INV IN (15" S)=4937.25 INV OUT (15" N)=4937.05 DEPTH=7.00 39.90 LF - 15'' ADS @ 0.50% STA=76+02.88 (STORM C) STA=100+00.00 STORM C7 SDMH C7 4'Ø MH RIM=4945.78 INV IN (18" N)=4936.60 INV IN (15" S)=4936.85 INV OUT (18" E)=4936.40 DEPTH=9.37 PROPOSED GRADE 100 yr HGL EXISTING GROUND HGL HGL HGL 4945.24 4943.99 4945.56 4945.40 4944.01 41.3 32.8 24.3 26.06 0.88% 4937.78 4937.640.33% 0.64% 0.39% 4937.56 4937.36 4937.15 4936.99 4936.63 4936.83 4936.38 4938.01 5265 Ronald Reagan Blvd., Suite 210 Johnstown, CO 80534 970.800.3300 O www.gallowayUS.com 2017. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: H:\Hartford Homes\CO, Timnath - HFHLV0001.02_Timberline & Vine Multi-Family\CADD\4-As Built\Site\HFHLV1.02_SD03_S_as-built-2.dwg - Kyle Pollock - 3/26/2019 HFHLV0001.02 11.10.2017 Init.#Issue / DescriptionDate EAST RIDGE TH IR D FILING MON TAGE TOWNH OMES FORT COLLINS, CO THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELD LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. DateCity Engineer Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner SD06 JEP NEW ( IN FEET ) 1 inch = ft. 0 Feet5050 50 100 150 KEYMAP STA: SCALE: H: 1"=V: 1"= toPRIVATE STORM C5A 80+00.00 80+23.77 50 5 ROTATION: 0° STA: SCALE: H: 1"=V: 1"= toPRIVATE STORM C6 90+00.00 92+29.37 50 5 ROTATION: 90° STA: SCALE: H: 1"=V: 1"= toPRIVATE STORM C7 100+00.00 101+26.09 50 5 ROTATION: 90° SD06 SD06 SD06 PROPOSED RIGHT-OF-WAY EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: T T T EXISTING STORM SEWER EXISTING GAS EXISTING TELEPHONE EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY E E EPROPOSED ELECTRIC GAS 8''W 8''SS 8''SS 8''W PROPOSED MANHOLE NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALL VERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEETS SS01-SS06 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE EXISTING CONDITIONS SHEETS FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE IN PAVED AREAS. AB 09/07/18 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING DATED: SEPTEMBER 7, 2018