OVERALL SITE and DRAINAGE CERTIFICATION
Commercial, Multi-Family and Subdivision Certification Form and Checklist
Project Name:
Date:
Building Permit Numbers:
(Commercial or multi-family)
Per the requirement in Fort Collins Stormwater Criteria Manual (FCSCM) Chapter 3, Section 3.0 to certify as-
built construction to the approved drainage and grading plans, please fill in all applicable items in this
Certification Form for Commercial, Multi-Family and Overall Single Family sites. NOTE: several items must be
verified during construction. A copy of the approved grading plan must be submitted with the as-built grading
plan. (As-built elevations must be written in red next to the approved elevations.)
•Use “Yes” for items completed as described.
•Use “N/A” for items that are not applicable to the site being certified.
•If any blanks are “No,” attach an explanation referencing the item number below.
Attach an explanation or description of the as-built condition for any items listed or for anything not listed but
shown on the approved construction plans.
Provide an as-built redline or Mylar drawing with the following:
I.Water Quality and Quantity Detention Basin - FCSCM Ch. 6 and 7
For multiple detention basins on a site, provide the following for each basin separately:
A. Volume: As-built topographic verification is attached at 1-foot (or less) contour intervals and
volume verification calculations for the water quality capture volume and the 100-year detention storage
volume.
1. Detention basin topography was prepared by a professional land surveyor registered in the state
of Colorado.
2.Both proposed and as-built contours are shown on the same plan sheet (dashed lines for
proposed and solid lines for as-built).
3.All critical spot elevations as shown on the approved construction plans have been verified and
the as-built elevations are shown on the plan sheet.
4.Stage-storage-discharge tables are provided on a separate document.
5.Verification that designed drain time is in compliance with Colorado Revised Statute § 37-92-
602(8) is attached and has been uploaded to the Statewide Compliance Portal
(tinyurl.com/COCompliancePortal) for approval. Uploaded documents must include:
a.The cover sheet from the approved drainage report
b.The stamped certification page from the approved drainage report
c.As-built topographic survey
d.Stamped certification page from the Overall Site & Drainage Certification
e.PDF output from the Stormwater Detention and Infiltration Design Data Speadsheet
Accepted 9/10/2019 WL
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
18''SS
18''SS
18''SS
18''SS8''SS
8''SS
8''SS
8''SS
8''SS
8''SS 8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
18''SS
18''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS 8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
12''W
12''W
12''W
12''W
12''W
12''W
12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
8''SS
8''SS
8''SS
18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS
8''W
8''W
8''W
8''W
8''W 8''W 8''W 8''W 8''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W
12''W
12''W
12''W
12''W
12''W
12''W
12''W
8''W
8''W
8''W
8''W
8''W
8''W
12''W
12''W
8''SS
8''SS
8''SS
8''SS
18''SS
8''SS 8''SS 8''SS8''SS 8''SS 8''SS
8''SS
8''SS
8''SS
8''SS 8''SS 8''SS
8''SS 8''SS 8''SS
8''W
8''W
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
12''W
12''W
8''SS
8''SS
8''SS 8''SS
8''SS
8''SS8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS 8''SS 8''SS 8''SS
8''SS
8''SS
8''SS
8''SS
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W 8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W 8''W 8''W 8''W 8''W
8''W
8''W
8''W 8''W
18''SS
18''SS
8''SS
8''W
8''SS
8''W
12''W 12''W 12''W
12''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
S
S
S
S
S
12''W
12''W
8''W
18''SS
18''SS
S
(UNPLATTED)
O
WNER:
WHITHAM
FARMS
LLC
REC.
NO.
20010120159
BARNSTORMER STREET
BIPLANE STREET
COLEMAN STREET
SUPERCUB LANE
CONQUEST STREET
NAVION
LANE
VICOT
WAY
YEAGER
STREET
MARQUISE
STREET
FAIRCHILD
STREET
QUINBY
STREET
FAIRCHILD
STREET
SYKES DRIVE
BARNSTORMER STREET
BIPLANE STREET
COLEMAN STREET
VICOT
WAY
CONQUEST STREET
CONQUESTSTREET
CONQUEST
WAY
ALLEY A
ALLEYA
ALLEYA
ALLEYAALLEYA
ALLEY A
MARQUISESTREET
ZEPPELINWAY
SYKESDRIVE
VICOTWAY
PRIVATEDRIVEAA
ZEPPELINWAY
PRIVATEDRIVETIGERCATWAY
LOT 29
LOT 30
LOT 31
LOT 4
LOT 3
LOT 5
LOT 6
LOT 7
LOT 30
LOT 29
LOT 28
LOT 27
LOT 7
LOT 9
LOT 8
LOT 6
LOT 5
LOT 4
LOT 3
LOT 2
LOT 1
LOT 34
LOT 33
LOT 32
LOT 31
LOT 2
LOT 1
LOT 32
LOT 12
LOT 11
LOT 10
LOT 9
LOT 8
LOT 7
LOT 6LOT 5
LOT 4
LOT 1
LOT 3
LOT 2
LOT 15 LOT 14
LOT 13
LOT 12
LOT 11
LOT 2 LOT 3
LOT 4
LOT 5
LOT 6
LOT 7
LOT 1
LOT 8
LOT 9
LOT 10
LOT 1
LOT 2
LOT 1LOT 16
LOT 15
LOT 14LOT 3
LOT 4 LOT 13
LOT 12LOT 5
LOT 6 LOT 11
LOT 10LOT 7 LOT 7
LOT 6 LOT 13
LOT 5
LOT 14
LOT 4 LOT 15
LOT 3 LOT 16
LOT 17LOT 2
LOT 18
LOT 8 LOT 9
LOT 8 LOT 11
LOT 12
LOT 10
LOT 9
LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 10LOT 11LOT 12LOT 13
LOT 1
LOT 14
LOT 7
LOT 8LOT 9
LOT 3 LOT 4 LOT 5
LOT 10LOT 11LOT 12
LOT 1 LOT 2
LOT 13LOT 14
LOT 6 LOT 7
LOT 8LOT 9
LOT 1
LOT 2
LOT 3 LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
LOT 11
LOT 12
LOT 13
LOT 1
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
LOT 9
LOT 10
LOT 11
LOT 12
LOT 13
LOT 14
LOT 15
LOT 16
LOT 17
LOT 18
LOT 19
LOT 20
LOT 21
LOT 2 LOT 3 LOT 4
LOT 7 LOT 6 LOT 5
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5
LOT 27LOT 28LOT 29LOT 30LOT 31 LOT 25
LOT 7 LOT 8 LOT 9
LOT 23LOT 24
LOT 6
LOT 26
LOT 10 LOT 11 LOT 12 LOT 13LOT 1
LOT 8
LOT 14
LOT 19
LOT 20LOT 21LOT 22
LOT 18
LOT 17
LOT 16
LOT 15
LOT 2 LOT 3 LOT 4
LOT 5LOT 6LOT 7
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7
LOT 16LOT 17LOT 18LOT 19LOT 20LOT 21LOT 22 LOT 15 LOT 14 LOT 13
LOT 10LOT 9LOT 8LOT 1
LOT 8
LOT 11
LOT 12
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 7LOT 8LOT 9LOT 10LOT 11LOT 12 LOT 3
LOT 2
LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
LOT 1
LOT 3 LOT 14
LOT 4
LOT 5
LOT 6
LOT 13
LOT 12
LOT 11
LOT 10LOT 7
LOT 8 LOT 9
LOT 1 LOT 16
LOT 15LOT 2
LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7LOT 7 LOT 8 LOT 9 LOT 10 LOT 8LOT 1LOT 11LOT 6LOT 5LOT 4LOT 3LOT 2LOT 1
LOT 1
LOT 2
LOT 3
LOT 10
LOT 11
LOT 4
LOT 5
LOT 7
LOT 8
LOT 9
LOT 1
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 7LOT 8LOT 9LOT 10LOT 11LOT 12
LOT 13
TRACT
T
TRACT
S
TRACT R
TRACT
P
TRACT M
TRACT N
TRACTL
TRACT
Q
TRACTU
TRACT O
TRACT A
BLOCK 7
BLOCK 8
BLOCK 9
BLOCK 9
BLOCK 20
BLOCK 21
BLOCK 10
BLOCK 19
BLOCK 7
BLOCK 10
BLOCK 18
BLOCK 19 BLOCK 21
BLOCK 22
BLOCK 23BLOCK 17
BLOCK 11
BLOCK 8
BLOCK 5
BLOCK 5
BLOCK 6
BLOCK 6
BLOCK 12
BLOCK 11
BLOCK 15
BLOCK 16
BLOCK 16
BLOCK 23
BLOCK 22
BLOCK 24
BLOCK 14
BLOCK 13
BLOCK 12
BLOCK 4BLOCK 4
BLOCK 1
BLOCK 1 TRACTE
TRACTE
16' EMERGENCY ACCESS ROAD,
COMPACTED ROAD BASE TO
SUPPORT 40 TONS PER
GEOTECH.
(CONSTRUCT IN PHASE 1A)
16' TEMPORARY EMERGENCY
ACCESS ROAD, CONSTRUCT IN
PHASE 1A, COMPACTED ROAD
BASE TO SUPPORT 40 TONS
PER GEOTECH. (SEE NOTE #8)
16' TEMPORARY EMERGENCY
ACCESS ROAD, CONSTRUCT IN
PHASE 1A, COMPACTED ROAD
BASE TO SUPPORT 40 TONS
PER GEOTECH. (SEE NOTE #8)
(SEE NOTE #9)
PERMANENT 16' EMERGENCY ACCESS ROAD,
COMPACTED ROAD BASE TO
SUPPORT 40 TONS PER GEOTECH.
(CONSTRUCT IN PHASE 1A)
8''W
8''W
8''W
8''W
8''W
8''SS8''SS
8''SS
8''W
8''SS 8''SS 8''SS 8''SS
8''W
8''SS
8''SS 8''SS 8''SS 8''SS 8''SS 8''SS
8''W
8''SS 8''SS 8''SS 8''SS
S
S S S S S S
S S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
6''W
6''W
6''W
6''W
M
M
M
MM
M
M
MM
MM
M
M
M
M
M
M
M
8''SSM
M
M
M
M
M
PHASE
6
PHASE
8B
PHASE
4
PHASE
1A
PHASE
2B
PHASE
5C
PHASE
4
PHASE
7B
PHASE
7B
PHASE
9
PHASE
8A
PHASE
6
PHASE
1BPHASE
3
PHASE
1A
PHASE
8C
PHASE
7A
#
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF THE
ARCHITECT. COPYRIGHTS AND
INFRINGEMENTS WILL BE ENFORCED AND
PROSECUTED.
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2015. Galloway & Company, Inc. All Rights Reserved
SHEET TITLE:
Date:
Drawn By:
Project No:
Checked By:
HFHLV0001.01
12.05.16
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
MATCHLINE-SEE SHEET PH02
NOTES:
LEGEND:
PROJECT BOUNDARY
PHASE LINE
PHASING LEGEND:
PHASE ONE A -
PHASE ONE B -
PHASE TWO A-
PHASE TWO B-
PHASE THREE -
PHASE FOUR -
PHASE FIVE A-
PHASE FIVE B-
PHASE FIVE C-
TEMP. FIRE HYDRANT
PROPOSED
ROADWAY
END OF PHASE ROADWAY
AND UTILITY TERMINATIONS
TYPE III
BARRICADE
10'x5'x1.5' TYPE 'L'
RIPRAP PAD
10'x5'x1.5' TYPE 'L'
RIPRAP PAD
CONSTRUCT SANITARY TO
NEXT MANHOLESS 8"
W 8"W 8"
SS 8"
PHASE SIX -
PHASE SEVEN A -
PHASE SEVEN B -
PHASE EIGHT A -
PHASE EIGHT B -
PHASE EIGHT C-
PHASE NINE -
CITY PARK -
UTILITY PHASING
PHASE REQUIRED UTILITY INFRASTRUCTURE
1A SANITARY
SS LINE 1 SSMH 1 to SSMH 1-12, SS LINE 1-4 SSMH 1-4 to SSMH 1-4.1, SS
LINE 1-5 SSMH 1-5 to SSMH 1-5.1, SS LINE 1-6 SSMH 1-6 to 1-6.1, SS LINE
1-7 SSMH 1-7 to SSMH 1-7.1, SS LINE 1-9 SSMH 1-9 to SSMH 1-9.2, SS LINE
1-11, SS LINE 1-11.2, SS LINE 1-11.3, SS LINE 1-11.5 SSMH 1-11.5 to SSMH
1-11.5-1
1A STORM
SD LINE B OUTLET B to INLET B4 & SDMH B7 to FES B12, SD LINE B3, SD
LINE B8 SDMH B8 to SDMH B8.1, SD LINE B9, SD LINE C OUTLET C to
SDMH C5, SD LINE C3, SD LINE D FES D to SD INLET D5, SD LINE D2, SD
LINE D4, SD LINE D4.1, SD LINE E FES E to SDMH E3 & SD INLET D9 to
SDMH E14, SD LINE E13, SD LINE G, SD LINE G2, POND OUTFALL,
1B SANITARY
SS LINE 1-4 SSMH 1-4.1 to SSMH 1-4.7, SS LINE 1-4.3, SS LINE 1-4.5, SS
LINE 1-4.6, SS LINE 1-5 SSMH 1-5.1 to SSMH 1-5.3, SS LINE 1-6 SSMH 1-6.1
to SSMH 1-6.3, SS LINE 1-7 SSMH 1-7.1 to SSMH 1-7.3, SS LINE 1-9 SSMH
1-9.2 to SSMH 1-9.3, SS LINE 1-12A, SS LINE 1-12A.3, SS LINE 1-12A.4
SSMH 1-12A.4 to SSMH 1-12A.4-1
1B STORM
SD LINE A, SD LINE A3, SD LINE A3-1, SD LINE A4 INLET A4A to INLET A4.1,
SD LINE A6, SD LINE E SDMH E3 to SD INLET E9 & SDMH E14 to SD INLET
E17, SD LINE E3, SD LINE E16, FUTURE POND OUTFALL FPO to FPO-4,
IRRIGATION, IRRIGATION 7 IRJB 7 to OUTLET 7-5
2A STORM SD LINE A4 INLET A4.1 to INLET A4.2
3 SANITARY SS LINE 1 SSMH 1-12 to SSMH 1-13, SS LINE 1-12 SSMH 1-12 to SSMH
1-12.1
3 STORM SD LINE D INLET D5 to INLET D9, SD LINE D7
UTILITY PHASING
PHASE REQUIRED UTILITY INFRASTRUCTURE
4 SANITARY SS LINE 1-12 SSMH 1-12.1 to SSMH 1-12.7, SS LINE 1-12.4 SSMH 1-12.4 to
SSMH 1-12.4-1, SS LINE 1-12.5 SSMH 1-12.5 to 1-12.5-1
4 STORM SD LINE B8 SDMH B8.1 to FES B8.2, SD LINE C SDMH C5 to SDMH C7, SD
LINE C5, SD LINE C6
5A STORM FUTURE POND OUTFALL FPO-4 to FPO-5,
5BSANITARY SS LINE 1-4 SSMH 1-4.7 to 1-4.9
5C STORM SD LINE B INLET B4 to SDMH B7, SD LINE B6
5C
SANITARY
SS LINE 1-4 SSMH 1-4.9 to 1-4.11, SSMH 1-11.5 SSMH 1-11.5-1 to SSMH
1-11.5-2
6 SANITARY
SS LINE 1 SSMH 1-13 to SSMH 1-17, SS LINE 1-12.4 SSMH 1-12.4-1 to 1-12.4-2,
SS LINE 1-12.5 SSMH 1-12.5-1 to SSMH 1-12.5-2, SS LINE 1-14 SSMH 1-14 to
SSMH 1-14.1, SS LINE 1-15, SS LINE 1-15A SSMH 1-15 to SSMH 1-15A.1, SS
LINE 1-16 SSMH 1-16 to SSMH 1-16.1, SS LINE 1-16A, SS LINE 1-17, SS LINE
1-17A SSMH 1-17 to SSMH 1-17A.1
6 STORM SD LINE C SDMH C7 to INLET C11, SD LINE C7, SD LINE C9, SD LINE C10,
7B
SANITARY
SS LINE 1-12A.4 SSMH 1-12A.4-1 to SSMH 1-12A.4-2, SS LINE 1-14 SSMH
1-14.1 to SSMH 1-14.2, SS LINE 1-15A SSMH 1-15A.1 to SSMH 1-15.1A.2, SS
LINE 1-16 SSMH 1-16.1 to SSMH 1-16.3, SS LINE 1-17A SSMH 1-17A.1 to
1-17A.3
7B STORM SD LINE D INLET D9 to FES D18,
1 09/19/16 Phase 1 Revised to 1A & 1B JEP
1. THE PHASE LINES SHOWN DELINEATE THE LOTS THAT ARE INCLUDED WITHIN A PHASE. GRADING AND
INSTALLATION OF INFRASTRUCTURE OUTSIDE THE LIMITS OF THE PHASE MAY BE REQUIRED.
2. ROADWAYS MAY REQUIRE SAWCUTS, MILLING AND/OR PATCHING OF ASPHALT. FINAL LIMITS WILL BE
DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL PATCHING AND STREET
REPAIRS SHALL BE PER THE MOST CURRENT CITY STANDARDS.
3. THE PHASING DESIGNATIONS SHOWN ARE FOR REFERENCE ONLY, THEY MAY NOT HAVE ANY
RELATIONSHIP TO THE ACTUAL CONSTRUCTION SEQUENCE.
4. TEMPORARY FIRE HYDRANTS ARE REQUIRED AT THE UPSTREAM END OF ALL "DEAD-END" WATER LINES
IN EACH PHASE. THE FIRE HYDRANTS SHALL BE REMOVED UPON CONTINUATION OF THE WATER MAIN
DURING THE CONSTRUCTION OF THE NEXT PHASE.
5. SANITARY SEWER MAIN SHALL BE EXTENDED TO THE NEXT MANHOLE BEYOND THE PHASE LINE.
6. FOR DETAILED OVERLOT GRADING SEE SHEETS GR01-GR08.
7. STORM MAY TERMINATE PRIOR TO THE MANHOLE NOTED WITHIN THE UTILITY PHASING TABLE. THE
TERMINATION SHALL OCCUR 20' BEYOND PHASING LINE OR 20' BEYOND THE EDGE OF PAVEMENT
WHICHEVER IS LONGER. IF THE STORM SYSTEM IS BROKEN BY PHASES, THE STORM SYSTEM MAY BE
COMPLETED OR A TEMPORARY SWALE MAY BE PROVIDED FROM INVERT TO INVERT WITH A MINIMUM 2'
FLAT BOTTOM AND A MAXIMUM 4:1 SIDE SLOPE.
8. CONTRACTOR SHALL ADEQUATELY MAINTAIN AND PROVIDE SNOW REMOVAL AS NEEDED DURING SITE
CONSTRUCTION.
9. TEMPORARY ACCESS FROM THE INTERSECTION OF CONQUEST STREET AND QUINBY STREET TO ALLEY
B SHALL REMAIN IN PLACE UNTIL EMERGENCY ACCESS SOUTH OF THE POND AND CONNECTION TO
TIMBERLINE ROAD (ALONG CRUSADER STREET (A) & ZEPPELIN WAY IS COMPLETE.
2 03/29/17 Utility and Plan Revisions JEP
3 11/06/17 Phase 2,5, and 8 Revisions JEP
1/19 Page 2
B. Water Quality and Quantity Detention Basin Grading: Attached is as-built verification that there is
a minimum 2% positive fall into the concrete trickle pans or flow-line(s) from all areas in the bottom of
the detention pond. If there is a “soft pan” in the flow-line, all areas still must meet the minimum 2%
grade requirement.
1. Low Flow: Choose one of the following detention basin low flow options as applicable:
a. Turf swale for low flow path in detention basin.
There is a minimum 2% grade in the flow-line(s) of the detention basin. The flattest as-built grade
is .
b. Concrete pan for low flow in detention basin.
There is a concrete pan installed that meets the grades as shown on the approved construction
plans. (Show as-built spot elevations.)
c. Soft pan for low flow in detention basin.
• Verify and document the soft pan material gradation, trench width and depth - to be verified
during construction by engineer. Picture documentation is preferred or engineer’s statement of
visual inspection and compliance. (Choose one below.)
o There is a soft pan with an underdrain installed that meets the design on the approved
construction plans. (Show the underdrain grades, bedding material, geotextile, spot elevations,
bends, cleanouts, etc.)
o There is soft pan installed without an underdrain but there is a type A or B soil. The soil
type must be documented by supplying verification from a registered professional geotechnical
engineer.
NOTE: Spot elevations are to be within 0.2 ft. +/-.
2. Side Slopes: The as-built side slopes of the detention basin have been calculated and are shown.
Indicate the side slope with an arrow and a numerical value (e.g., 6.25:1). The maximum slope allowed
is 4:1. Small areas of 3:1 may be acceptable, but slopes steeper than 3:1 must be stabilized or re-
graded. Provide documentation if a variance was granted for steeper slopes during the design process.
3. Spillway: The following items must be field verified:
a. The location of the spillway is indicated on the as-built plan.
b. The width of the spillway is indicated on the as-built plan.
c. The elevation(s) of the spillway is shown on the as-built plan.
d. A concrete ribbon defines the location and grade of the spillway.
e. There is downstream scour protection in the spillway as per the construction plans. Indicate
type: (riprap size “D50” gradation and bedding type, geotextile, buried
riprap with inches of bury, etc.).
f. There are no obstructions in the spillway, such as trees, bushes, sidewalks, landscape
features, rocks, etc.
1/19 Page 3
4. Outlet Structure:
a. The orifice plate for the approved release rate is installed with the correct size and location of
the orifice.
b. The orifice plate for the water quality outlet is installed with the correct hole size, number of
rows and columns of holes.
c. The bottom hole on both the water quality and quantity outlets are at the bottom of the plate
so no water ponds in front of the plate.
d. The well screen is the correct material and is installed as shown on the construction plans.
e. 100-year overflow grate elevation is . (Elev. A on detail D-46)
f. The top elevation of the water quality capture volume is . (Elev. B on detail
D-46)
g. Overflow grate is made of the correct material, has the correct bar spacing, is hinged at the
top and bolted at the bottom.
h. The bottom of the outlet box has no obstructions or misalignments that will cause it to retain
runoff water and is sloped at 2% towards outlet.
II. Channels/Swales - FCSCM Ch. 8, Sec. 2.0 and Ch. 9, Sec. 5.0
A. Capacity: The as-built capacity of all the major channels and swales has been verified. They meet
or exceed capacity requirements shown in the approved drainage study for this project.
1. All swales are located within the drainage easements as shown on the construction plans.
2. Longitudinal slopes and side-slopes (cross-sections) have been verified. Design criteria requires
longitudinal slopes of 2% min. (on vegetated swales) and side-slopes no steeper than 4:1. If these
criteria are not met, the certification engineer will write a justification and propose mitigation for each
instance or have the issues corrected. If variances to these criteria have previously been approved and
are shown on the construction plans, no justification is needed.
3. As-built spot elevations on channels/swales are shown that correspond to spot elevations
shown on the approved construction plans.
4. All permanent erosion control measures are installed as shown on the approved construction
plans (e.g., drop structures, riprap, TRMs, etc.). (Include pictures and verification of the materials used
as part of this verification.)
5. All pans, curbs, storm pipes or other appurtenances appropriately tie into each other in the
system. (Pictures at tie-in points suggested.)
6. The minimum freeboard is provided for all channels and swales as shown on the approved
construction plans or as identified in the approved drainage study. (Show the freeboard provided on
the cross-sections as on the construction plan set or attached as separate documentation.)
7. The low flow portion of all channels or swales is clear of obstructions. (No landscaping, trees,
shrubs, sod, etc. infringe on the low flow portion of channels or swales.)
1/19 Page 4
III. Storm Pipes (aka storm drains) - FCSCM Ch. 9, Sec. 4.0
A. Storm Drain Pipe Capacity: The as-built capacity of all pipes installed on this project has been
verified and meets or exceeds the capacity requirements shown in the approved drainage study for this
project.
1. All storm drain pipe sizes and materials have been verified and are in conformance with the
approved construction plans. (Indicate on the plan and profile sheets that they have been verified.)
Material and size substitutions must be approved prior to installation. If a pipe size or material was
changed during construction, the certification engineer must attach the approval documents or supply
them with this certification. Approval documents must include a calculation documenting the capacity
equivalency (equal or greater) of the substituted size.
2. The longitudinal slope of the pipe is as shown on the approved construction plans. The
acceptable minimum slope is 0.4%. All slopes flatter than the designed slope on the construction plans
must be justified with capacity calculations on an attached sheet.
3. The as-built invert elevations have been verified and are shown on the plan and profile sheets of
the approved construction plans.
B. Storm Drain Pipe Installation Requirements: All pipes are installed in accordance with the
approved construction plans and construction specifications.
1. The minimum cover requirements for all pipes have been met as shown on the approved
construction plans. These will be called out in critical locations.
2. All encasements and clearances as specified on the approved construction plans have been met.
3. Any specific joint types or construction methods specified on the approved construction plans
have been met. (List on a separate sheet and attach to this certification.)
IV. Concrete Pans - FCSCM Ch. 8, Sec. 2.0
A. Construction/Installation: All concrete pans have been constructed in accordance with the
approved construction plans.
1. The concrete pans are the correct size/width as shown on the approved construction plans.
2. The longitudinal slopes of the pans are as shown on the approved construction plans. The
certification engineer must justify or mitigate longitudinal slopes less than the minimum of 0.4% unless
a flatter slope was approved and is shown on the approved construction plans. Provide mitigation or
justification by separate document.
3. The cross-section of the pan is as shown on the construction plans. (Specifically, the pan cross-
section is “V” shaped and meets the side slope shown on the detail.)
4. The concrete pans are a minimum of 6 inches thick without reinforcement and a minimum of 4
inches thick with a minimum of 6X6-W14xW14 reinforcement per detail D20B and D20C. (Provide
documentation of the reinforcement used if different than shown on the details or on the approved
construction plans.)
5. The spot elevations shown on the concrete pan(s) have been verified and are shown on the as-
built drawings.
8''SS
8''SS
8''SS
8''SS8''SS8''SS
12''W12''W12''W12''W12''W12''W12''W12''W
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''W
8''W
8''W
8'
'
W
8''SS
8''SS
12''W
12''W
8''W
12''W12''W12''W12''W12''W
8''W
8''W
8''W
103+78.30
99+90
100+00101+00102+00103+00
LO
T
1
LO
T
9
LO
T
8
LO
T
7
LO
T
6
LO
T
5
4
LO
T
1
5
LO
T
1
4
LO
T
LO
T
1
LO
T
8
TRACT
N
BL
O
C
K
5
VICOT WAY
SANITARY LINE 1-12
SEE SHEET SS21
4925
4930
4935
4940
4945
4950
4955
4925
4930
4935
4940
4945
4950
4955
99+00100+00101+00102+00103+00104+00104+50
18
"
M
I
N
.
18
"
M
I
N
.
ST
A
=
6
9
+
5
7
.
5
4
(
S
T
O
R
M
B
)
ST
A
=
1
0
0
+
0
0
.
0
0
S
T
O
R
M
B
8
SD
M
H
B
8
8'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
4
.
4
5
IN
V
I
N
(
5
4
"
W
)
=
4
9
3
5
.
5
7
IN
V
I
N
(
4
2
"
N
)
=
4
9
3
6
.
5
7
IN
V
O
U
T
(
6
0
"
S
)
=
4
9
3
5
.
0
7
DE
P
T
H
=
9
.
8
8
42''RCP 329.03 LF @ 0.48%
ST
A
=
1
0
3
+
2
9
.
0
3
SD
M
H
B
8
.
1
8'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
6
.
3
9
IN
V
I
N
(
4
2
"
W
)
=
4
9
3
8
.
3
5
IN
V
O
U
T
(
4
2
"
S
)
=
4
9
3
8
.
1
5
DE
P
T
H
=
8
.
2
4
42''RCP
39.27 LF
@ 0.40%
ST
A
=
1
0
3
+
6
8
.
3
0
FE
S
B
8
.
2
42
"
F
E
S
IN
V
O
U
T
(
4
2
"
E
)
=
4
9
3
8
.
5
0
STA=100+28.07
TOP=4934.83
12"WATER CROSSING
STA=100+11.20
INV=4933.02
8"SANITARY CROSSING
STA=102+78.78
INV=4934.76
8"SANITARY CROSSING
STA=102+89.67
TOP=4936.08
8"WATER CROSSING
HGL HGL HGL HGL HGL HGL HGL
EXISTING GRADE
PROPOSED GRADE
100 yr HGL
CONCRETE
CUT-OFF
WALL
SD06
JEP
CMG
Date Issue /Description#
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY,AND MAY NOT BE DUPLICATED,
DISCLOSED,OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF THE
ARCHITECT.COPYRIGHTS AND
INFRINGEMENTS WILL BE ENFORCED AND
PROSECUTED.
3760 E.15th Street,Suite 202
Loveland,CO 80538
970.800.3300 O
www.gallowayUS.com
C 2015.Galloway &Company,Inc.All Rights Reserved
Init.
OF 188 SHEETS
SHEET TITLE:
Date:
Drawn By:
Project No:
Checked By:
HFHLV0001.01
12.05.16
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath,CO 80547
970.674.1109
KEYMAP
STA:
SCALE:H:1"=V:1"=
toSTORMDRAINB8100+00.00 103+68.30
50 5
SD06
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG,GRADE,OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
R
DateCityEngineer
Date
Date
Date
Date
Stormwater Utility
Parks &Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water &Wastewater Utility
City of Fort Collins,Colorado
UTILITY PLAN APPROVAL
Environmental Planner
LEGEND:
NOTES:
1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY.IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES,PUBLIC OR PRIVATE,WHETHER SHOWN ON THE PLANS OR NOT,PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2.JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER
THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES.LAYING
LENGTH INCLUDES FLARED END SECTIONS.
4.RCP SHALL BE CLASS III OR GREATER.PIPE MATERIAL,BEDDING,AND INSTALLATION WITHIN PUBLIC
RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS.ALTERNATES (SUCH AS ADS N-12 OR
HP SANITITE)OUTSIDE OF THE R.O.W.SHALL BE APPROVED IN ADVANCE BY THE ENGINEER.ALL JOINTS
SHALL BE 'WATERTIGHT'USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER
ASTM F477 /D3212 FOR PLASTIC PIPE).
5.ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
6.MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3.CONTRACTOR SHALLVERIFY THAT
MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e.,WITHIN PRE-CASTER'S TOLERANCES,ETC.).
7.SEE DETAILS FOR RIPRAP PAD SIZING.
8.PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE.
9.MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED.
10.SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY.SEE SHEET SS01-SS35 FOR FINAL
ELEVATIONS.
11.WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY.THE CONTRACTOR SHALL VERIFY THAT 18"
VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS.
12.SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES.
13.ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER,CROSSPANS AND SIDEWALKS.
14.MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14"BELOW FINISHED GRADE IN PAVED AREAS.
15.SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL.
16.THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE
APPROVED LANDSCAPE PLAN.
S
PROPOSED STORM INLET
EASEMENT LINE
PROPOSED LOTLINE
PROPOSED RIGHT-OF-WAY
PROPERTY BOUNDARY
PROPOSED CURB &GUTTER
EXISTING GAS
EXISTING OVER-HEAD ELECTRIC
PROPOSED FIBER OPTIC
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED FIRE HYDRANT
PROPOSED RESIDETIAL SERVICE
PROPOSED SEWER SERVICE
EXISTING SANITARY SEWER
PROPOSED SANITARY SEWER
EXISTING WATER MAIN
PROPOSED WATER MAIN W 8"
SS SSSS8"
4900
4900
PROPOSED CONTOUR
EXISTING CONTOUR
PROPOSED WATER LINE LOWERING
(IN FEET )
1 inch =ft.
050 50
50
100 150
AB 01.18.19 Record Drawings JEP
INV OUT (24"S)=4912.20 4912.48
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E.LOCKWOOD,PLS
PLS.0038316
DATED:01.10.19
49
3
5
.
1
4
49
3
6
.
5
6
49
3
5
.
4
2
49
4
4
.
6
6
49
3
7
.
9
7
49
3
8
.
1
7
49
4
5
.
8
4
49
3
8
.
3
8
327.50 LF 0.43%
41.50 LF
0.51%
327.50 LF 0.43%
0.51%41.50 LF
RIM ELEVATION WILL BE RAISED TO GRADE WITH
PHASE 6 IMPROVEMENTS.
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''W
8''W
8''W
8''W
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
8''W
ALLEYA
ZEPPELINWAY
SYKESDRIVE
LOT 23
LOT 29
LOT 5 LOT 24
LOT 22
LOT 26
LOT 27
LOT 28
LOT 30
LOT 31
LOT 4LOT3
LOT 6
LOT 7
LOT 8
LOT 2
LOT 1
LOT 34
LOT 32
LOT 6
LOT 7
LOT 10
LOT 1
LOT 5
LOT 17
LOT 18
LOT 2
LOT 3
LOT 4
LOT 16
LOT 19
LOT 20
LOT 21
TRACTL
TRACTE
TRACTE
TRACTE
BL
O
C
K
1
2
BLO CK 4
STORM DRAIN B
SEE SHEET SD03
110+00
111+00
112+00
113+00
114+00
115+00
116+00
117+00
118+00
119+00
120+00
S
S
S
S
S
S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Y
Y
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
D
D
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
121.08LF@1.78%
149.52LF@2.11%
210.17LF@0.56%
DD
S
S
S
S
S
S
S
SS
SS
SS
SS
SS
SS
SS
SS
D
D
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
PROPOSED
GRADE
EXISTING GRADE
18
"
M
I
N
.
ST
A
=
1
1
4
+
7
5
.
6
6
IN
L
E
T
C
2
10
'
C
D
O
T
T
Y
P
E
R
I
N
L
E
T
TB
C
=
4
9
4
3
.
3
1
IN
V
I
N
(
5
4
"
N
E
)
=
4
9
3
2
.
9
0
IN
V
O
U
T
(
6
0
"
S
W
)
=
4
9
3
2
.
9
0
DE
P
T
H
=
1
0
.
4
1
54''RCP
10.60 LF
@ 0.40%
ST
A
=
1
2
0
+
0
0
.
0
0
(
S
T
O
R
M
C
3
)
ST
A
=
1
1
4
+
8
7
.
7
5
S
T
O
R
M
C
SD
M
H
C
3
8'
Ø
M
H
RI
M
=
4
9
4
3
.
2
6
IN
V
I
N
(
5
4
"
N
W
)
=
4
9
3
2
.
9
5
IN
V
I
N
(
1
8
"
N
E
)
=
4
9
3
5
.
9
5
IN
V
O
U
T
(
5
4
"
S
W
)
=
4
9
3
2
.
9
5
DE
P
T
H
=
1
0
.
3
2
54''RCP 261.71 LF @ 0.40%
4920
4925
4930
4935
4940
4945
4950
4920
4925
4930
4935
4940
4945
4950
109+50110+00111+00112+00113+00114+00115+00116+00117+00118+00119+00120+00
ST
A
=
1
1
0
+
0
0
.
0
0
OU
T
L
E
T
C
EN
D
O
F
P
I
P
E
A
T
H
E
A
D
W
A
L
L
IN
V
I
N
(
6
0
"
N
)
=
4
9
3
1
.
0
1
60''RCP 211.87 LF @ 0.40%
ST
A
=
1
1
2
+
1
1
.
8
7
SD
M
H
C
1
8'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
1
.
7
5
IN
V
I
N
(
6
0
"
N
E
)
=
4
9
3
1
.
8
6
IN
V
O
U
T
(
6
0
"
S
)
=
4
9
3
1
.
8
6
DE
P
T
H
=
9
.
9
0
60''RCP 262.28 LF @ 0.40%
ST
A
=
1
1
7
+
4
9
.
4
7
SD
M
H
C
4
8'
Ø
M
H
RI
M
=
4
9
4
4
.
7
7
IN
V
I
N
(
5
4
"
N
E
)
=
4
9
3
3
.
9
9
IN
V
O
U
T
(
5
4
"
S
E
)
=
4
9
3
3
.
9
9
DE
P
T
H
=
1
0
.
7
8
54''RCP
124.92 LF
@ 0.40%
ST
A
=
1
3
0
+
2
3
.
5
0
(
S
T
O
R
M
C
5
)
ST
A
=
1
1
8
+
7
4
.
3
9
S
T
O
R
M
C
SD
M
H
C
5
7'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
3
.
8
7
IN
V
I
N
(
4
8
"
N
E
)
=
4
9
3
4
.
9
9
IN
V
I
N
(
1
8
"
N
W
)
=
4
9
3
7
.
4
9
IN
V
I
N
(
1
8
"
S
E
)
=
4
9
3
7
.
4
9
IN
V
O
U
T
(
5
4
"
S
W
)
=
4
9
3
4
.
4
9
DE
P
T
H
=
9
.
3
7
48''RCP
141.09 LF
@ 0.50%
18
"
M
I
N
.
STA=114+99.24
INV=4929.87
8"SANITARY CROSSING
STA=115+09.00
TOP=4931.01
8"WATER CROSSING
STA=117+39.22
INV=4931.13
8"SANITARY CROSSING
STA=117+60.57
INV=4931.12
8"SANITARY CROSSING
STA=117+72.06
TOP=4932.06
8"WATER CROSSING
100 yr HGL
HGL HGL
HGL HGL
HGL HGL HGL HGL HGL
HGL HGL HGL HGL HGL
HGL HGL HGL HGL
49
3
0
.
4
9
49
3
1
.
6
6
49
4
1
.
7
2
49
3
1
.
7
2
49
3
2
.
7
2
49
3
2
.
7
4
210.17 0.56%
259.94 0.38%
49
3
2
.
8
0
(
N
)
49
4
3
.
3
6
49
3
5
.
7
6
(
S
)
49
4
3
.
3
2
49
3
2
.
8
0
(
S
W
)
49
3
4
.
5
0
49
3
7
.
5
4
49
3
7
.
2
5
49
3
5
.
0
0
49
4
3
.
9
0
124.40 LF
@ 0.51%
146.10 LF
@ 0.52%
SD07
JEP
CMG
Date Issue /Description#
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY,AND MAY NOT BE DUPLICATED,
DISCLOSED,OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF THE
ARCHITECT.COPYRIGHTS AND
INFRINGEMENTS WILL BE ENFORCED AND
PROSECUTED.
3760 E.15th Street,Suite 202
Loveland,CO 80538
970.800.3300 O
www.gallowayUS.com
C 2015.Galloway &Company,Inc.All Rights Reserved
Init.
OF 188 SHEETS
SHEET TITLE:
Date:
Drawn By:
Project No:
Checked By:
HFHLV0001.01
12.05.16
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath,CO 80547
970.674.1109
KEYMAP
STA:
SCALE:H:1"=V:1"=
toSTORMDRAINC110+00.00 120+00.00
50 5
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
:
ST
A
:
SD
0
8
12
0
+
0
0
.
0
0
SD07
LEGEND:
NOTES:
1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY.IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES,PUBLIC OR PRIVATE,WHETHER SHOWN ON THE PLANS OR NOT,PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2.JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER
THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES.LAYING
LENGTH INCLUDES FLARED END SECTIONS.
4.RCP SHALL BE CLASS III OR GREATER.PIPE MATERIAL,BEDDING,AND INSTALLATION WITHIN PUBLIC
RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS.ALTERNATES (SUCH AS ADS N-12 OR
HP SANITITE)OUTSIDE OF THE R.O.W.SHALL BE APPROVED IN ADVANCE BY THE ENGINEER.ALL JOINTS
SHALL BE 'WATERTIGHT'USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER
ASTM F477 /D3212 FOR PLASTIC PIPE).
5.ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
6.MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3.CONTRACTOR SHALLVERIFY THAT
MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e.,WITHIN PRE-CASTER'S TOLERANCES,ETC.).
7.SEE DETAILS FOR RIPRAP PAD SIZING.
8.PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE.
9.MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED.
10.SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY.SEE SHEET SS01-SS35 FOR FINAL
ELEVATIONS.
11.WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY.THE CONTRACTOR SHALL VERIFY THAT 18"
VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS.
12.SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES.
13.ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER,CROSSPANS AND SIDEWALKS.
14.MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14"BELOW FINISHED GRADE IN PAVED AREAS.
15.SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL.
16.THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE
APPROVED LANDSCAPE PLAN.
S
PROPOSED STORM INLET
EASEMENT LINE
PROPOSED LOTLINE
PROPOSED RIGHT-OF-WAY
PROPERTY BOUNDARY
PROPOSED CURB &GUTTER
EXISTING GAS
EXISTING OVER-HEAD ELECTRIC
PROPOSED FIBER OPTIC
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED FIRE HYDRANT
PROPOSED RESIDETIAL SERVICE
PROPOSED SEWER SERVICE
EXISTING SANITARY SEWER
PROPOSED SANITARY SEWER
EXISTING WATER MAIN
PROPOSED WATER MAIN W 8"
SS SSSS8"
4900
4900
PROPOSED CONTOUR
EXISTING CONTOUR
PROPOSED WATER LINE LOWERING
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG,GRADE,OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
R
(IN FEET )
1 inch =ft.
050 50
50
100 150
268.19 LF @ 0.40%
49
4
4
.
7
5
49
3
3
.
8
6
49
3
3
.
8
6
AB 12.18.17 Record Drawings JEP
INV OUT (24"S)=4912.20 4912.48
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E.LOCKWOOD,PLS
PLS.0038316
DATED:10.05.17
AB2 01.18.19 Record Drawings JEP
0.51%
INV OUT (24"S)=4912.20 4912.48
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E.LOCKWOOD,PLS
PLS.0038316
DATED:01.10.19
60"RCP
15.10 LF
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
8''SS
12''W
12''W
12''W
12''W
12''W
12''W
12''W
18''SS
18''SS
18''SS
18''SS
18''SS
18''SS
18''SS
18''SS
8''W
8''W
8''W
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
8''W
8''W
8''W
8''SS
8''SS
8''SS
8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS
8''W
8''W
8''W
8''W
8''W
BI
P
L
A
N
E
S
T
R
E
E
T
LOT 8
LO
T
5
LO
T
1
6
LO
T
1
2
LO
T
1
LO
T
1
4
LO
T
7
LO
T
6
LO
T
1
3
LO
T
1
4
LO
T
4
LO
T
1
5
LO
T
1
4
LO
T
3
LO
T
1
7
LO
T
2
LO
T
1
8
LO
T
8
LO
T
1
1
LO
T
1
0
LO
T
9
.
LO
T
2
LO
T
1
3
LO
T
1
LO
T
1
LO
T
2
LO
T
1
3
LO
T
1
LO
T
LO
T
1
3
BL
O
C
K
9
BL
O
C
K
1
0
TR
A
C
T
O
BL
O
C
K
8
BL
O
C
K
1
1
BL
O
C
K
8
YEAGER STREET
STORM DRAIN C6
SEE SHEET SD09
CO
L
E
M
A
N
S
T
R
E
E
T
BA
R
N
S
T
O
R
M
E
R
S
T
R
E
E
T
CONQUESTSTREET
SANITARY LINE 1-15
SEE SHEET SS29
12"WATER LINE
SEE SHEET WT02
STORM DRAIN C10
SEE SHEET SD08
STORM DRAIN C9
SEE SHEET SD10
STORM DRAIN C7
SEE SHEET SD10
127+87.88
120+00
121+00
122+00123+00124+00125+00126+00
127+00
EXISTING GRADE
PROPOSED
GRADE
ST
A
=
1
8
0
+
0
0
.
0
0
(
S
T
O
R
M
C
1
0
)
ST
A
=
1
2
7
+
5
2
.
4
8
S
T
O
R
M
C
SD
M
H
C
1
0
6'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
8
.
2
5
IN
V
I
N
(
2
4
"
N
)
=
4
9
4
3
.
3
1
IN
V
I
N
(
2
4
"
S
)
=
4
9
4
3
.
3
1
IN
V
O
U
T
(
3
6
"
E
)
=
4
9
4
2
.
3
1
DE
P
T
H
=
5
.
9
4
24''RCP
24.15 LF
@ 0.50%
ST
A
=
1
2
7
+
7
6
.
6
3
IN
L
E
T
C
1
1
6'
D
O
U
B
L
E
T
Y
P
E
1
6
C
O
M
B
O
I
N
L
E
T
TB
C
=
4
9
4
8
.
4
6
IN
V
O
U
T
(
2
4
"
S
)
=
4
9
4
3
.
4
3
DE
P
T
H
=
5
.
0
3
4920
4925
4930
4935
4940
4945
4950
4920
4925
4930
4935
4940
4945
4950
120+00121+00122+00123+00124+00125+00126+00127+00128+00128+50
ST
A
=
1
4
0
+
0
0
.
0
0
(
S
T
O
R
M
C
6
)
ST
A
=
1
2
0
+
1
5
.
4
8
S
T
O
R
M
C
SD
M
H
C
6
8'
Ø
M
H
RI
M
=
4
9
4
5
.
6
9
IN
V
I
N
(
4
8
"
N
E
)
=
4
9
3
5
.
7
0
IN
V
I
N
(
3
0
"
S
E
)
=
4
9
3
7
.
2
0
IN
V
O
U
T
(
4
8
"
S
W
)
=
4
9
3
5
.
7
0
DE
P
T
H
=
9
.
9
9
48''RCP
114.44 LF
@ 0.50%
ST
A
=
1
5
0
+
0
0
.
0
0
(
S
T
O
R
M
C
7
)
ST
A
=
1
2
1
+
2
9
.
9
3
S
T
O
R
M
C
SD
M
H
C
7
8'
Ø
M
H
RI
M
=
4
9
4
7
.
1
3
IN
V
I
N
(
4
8
"
N
)
=
4
9
3
7
.
2
2
IN
V
I
N
(
4
2
"
E
)
=
4
9
3
6
.
7
7
IN
V
O
U
T
(
4
8
"
S
W
)
=
4
9
3
6
.
2
7
DE
P
T
H
=
1
0
.
8
5
48''RCP 262.99 LF @ 0.80%
ST
A
=
1
2
3
+
9
2
.
9
4
SD
M
H
C
8
8'
Ø
M
H
RI
M
=
4
9
4
8
.
7
6
IN
V
I
N
(
4
2
"
N
)
=
4
9
3
9
.
5
2
IN
V
O
U
T
(
4
8
"
S
)
=
4
9
3
9
.
3
2
DE
P
T
H
=
9
.
4
4
42''RCP 262.32 LF @ 0.80%
ST
A
=
1
7
0
+
0
0
.
0
0
(
S
T
O
R
M
C
9
)
ST
A
=
1
2
6
+
5
5
.
2
5
S
T
O
R
M
C
SD
M
H
C
9
6'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
8
.
8
8
IN
V
I
N
(
3
6
"
W
)
=
4
9
4
1
.
8
2
IN
V
I
N
(
3
6
"
N
)
=
4
9
4
2
.
4
2
IN
V
O
U
T
(
4
2
"
S
)
=
4
9
4
1
.
6
2
DE
P
T
H
=
7
.
2
6
36''RCP 97.23 LF @ 0.50%
18
"
M
I
N
.
18
"
M
I
N
.
ST
A
=
1
2
7
+
6
1
.
3
2
IN
V
=
4
9
3
4
.
9
7
18
"
S
A
N
I
T
A
R
Y
C
R
O
S
S
I
N
G
STA=127+71.13
TOP=4939.63
12"WATER CROSSING
STA=120+29.86
INV=4932.08
8"SANITARY CROSSING
STA=120+41.85
TOP=4933.91
8"WATER CROSSING
100 yr HGL
HGL HGL
HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL
HGL HGL
49
3
5
.
7
6
49
3
7
.
3
4
49
3
5
.
7
6
49
4
5
.
8
4
12''W
12''W
12''W
12''W
18''SS
18''SS
18''SS
18''SS
18''SS
8''W 8''W 8''W
8''SS
LO
T
1
LO
T
1
7
LO
T
2
LO
T
1
8
STORM DRAIN C9
SEE SHEET SD10
YEAGER STREET
12"WATER LINE
SEE SHEET WT02
STORM DRAIN C
SEE SHEET SD08
BA
R
N
S
T
O
R
M
E
R
S
T
R
E
E
T
170+00
180+00
PROPOSED
GRADE
24''RCP
7.76 LF
@ 0.52%
EXISTING GRADE
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
179+00 180+00 181+00 181+50
ST
A
=
1
2
7
+
5
2
.
4
8
(
S
T
O
R
M
C
)
ST
A
=
1
8
0
+
0
0
.
0
0
S
T
O
R
M
C
1
0
SD
M
H
C
1
0
6'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
8
.
2
5
IN
V
I
N
(
2
4
"
N
)
=
4
9
4
3
.
3
1
IN
V
I
N
(
2
4
"
S
)
=
4
9
4
3
.
3
1
IN
V
O
U
T
(
3
6
"
E
)
=
4
9
4
2
.
3
1
DE
P
T
H
=
5
.
9
4
ST
A
=
1
8
0
+
0
7
.
7
6
IN
L
E
T
C
1
0
.
1
10
'
C
D
O
T
T
Y
P
E
R
I
N
L
E
T
TB
C
=
4
9
4
8
.
3
8
IN
V
O
U
T
(
2
4
"
N
)
=
4
9
4
3
.
3
5
DE
P
T
H
=
5
.
0
3
100 yr HGL
SD08
JEP
CMG
Date Issue /Description#
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY,AND MAY NOT BE DUPLICATED,
DISCLOSED,OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF THE
ARCHITECT.COPYRIGHTS AND
INFRINGEMENTS WILL BE ENFORCED AND
PROSECUTED.
3760 E.15th Street,Suite 202
Loveland,CO 80538
970.800.3300 O
www.gallowayUS.com
C 2015.Galloway &Company,Inc.All Rights Reserved
Init.
OF 188 SHEETS
SHEET TITLE:
Date:
Drawn By:
Project No:
Checked By:
HFHLV0001.01
12.05.16
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath,CO 80547
970.674.1109
KEYMAP
STA:
SCALE:H:1"=V:1"=
toSTORMDRAINC120+00.00 127+56.82
50 5
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
:
ST
A
:
SD
0
7
12
0
+
0
0
.
0
0
STA:
SCALE:H:1"=V:1"=
toSTORMDRAINC10180+00.00 180+07.76
50 5
SD08
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG,GRADE,OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
R
DateCityEngineer
Date
Date
Date
Date
Stormwater Utility
Parks &Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water &Wastewater Utility
City of Fort Collins,Colorado
UTILITY PLAN APPROVAL
Environmental Planner
LEGEND:
NOTES:
1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY.IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES,PUBLIC OR PRIVATE,WHETHER SHOWN ON THE PLANS OR NOT,PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2.JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER
THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES.LAYING
LENGTH INCLUDES FLARED END SECTIONS.
4.RCP SHALL BE CLASS III OR GREATER.PIPE MATERIAL,BEDDING,AND INSTALLATION WITHIN PUBLIC
RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS.ALTERNATES (SUCH AS ADS N-12 OR
HP SANITITE)OUTSIDE OF THE R.O.W.SHALL BE APPROVED IN ADVANCE BY THE ENGINEER.ALL JOINTS
SHALL BE 'WATERTIGHT'USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER
ASTM F477 /D3212 FOR PLASTIC PIPE).
5.ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
6.MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3.CONTRACTOR SHALLVERIFY THAT
MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e.,WITHIN PRE-CASTER'S TOLERANCES,ETC.).
7.SEE DETAILS FOR RIPRAP PAD SIZING.
8.PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE.
9.MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED.
10.SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY.SEE SHEET SS01-SS35 FOR FINAL
ELEVATIONS.
11.WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY.THE CONTRACTOR SHALL VERIFY THAT 18"
VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS.
12.SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES.
13.ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER,CROSSPANS AND SIDEWALKS.
14.MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14"BELOW FINISHED GRADE IN PAVED AREAS.
15.SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL.
16.THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE
APPROVED LANDSCAPE PLAN.
S
PROPOSED STORM INLET
EASEMENT LINE
PROPOSED LOTLINE
PROPOSED RIGHT-OF-WAY
PROPERTY BOUNDARY
PROPOSED CURB &GUTTER
EXISTING GAS
EXISTING OVER-HEAD ELECTRIC
PROPOSED FIBER OPTIC
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED FIRE HYDRANT
PROPOSED RESIDETIAL SERVICE
PROPOSED SEWER SERVICE
EXISTING SANITARY SEWER
PROPOSED SANITARY SEWER
EXISTING WATER MAIN
PROPOSED WATER MAIN W 8"
SS SSSS8"
4900
4900
PROPOSED CONTOUR
EXISTING CONTOUR
PROPOSED WATER LINE LOWERING
(IN FEET )
1 inch =ft.
050 50
50
100 150
AB 01.18.19 Record Drawings JEP
INV OUT (24"S)=4912.20 4912.48
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E.LOCKWOOD,PLS
PLS.0038316
DATED:01.10.19
PROPOSED
GRADE
EXISTING GRADE
18
"
M
I
N
.
4920
4925
4930
4935
4940
4945
4950
4920
4925
4930
4935
4940
4945
4950
119+00 120+00 121+00 121+50
ST
A
=
1
1
4
+
8
7
.
7
5
(
S
T
O
R
M
C
)
ST
A
=
1
2
0
+
0
0
.
0
0
S
T
O
R
M
C
3
SD
M
H
C
3
8'
Ø
M
H
RI
M
=
4
9
4
3
.
2
6
IN
V
I
N
(
5
4
"
N
W
)
=
4
9
3
2
.
9
5
IN
V
I
N
(
1
8
"
N
E
)
=
4
9
3
5
.
9
5
IN
V
O
U
T
(
5
4
"
S
W
)
=
4
9
3
2
.
9
5
DE
P
T
H
=
1
0
.
3
2
ST
A
=
1
2
0
+
3
9
.
2
4
IN
L
E
T
C
3
.
1
12
'
Q
U
A
D
T
Y
P
E
1
6
C
O
M
B
O
I
N
L
E
T
RI
M
=
4
9
4
3
.
3
1
IN
V
O
U
T
(
1
8
"
S
W
)
=
4
9
3
6
.
7
0
DE
P
T
H
=
6
.
6
1
18''RCP
37.74 LF
@ 2.00%
STA=120+13.46
INV=4929.56
8"SANITARY CROSSING
STA=120+25.78
TOP=4934.75
8"WATER CROSSING
100 yr HGL
49
3
2
.
8
0
(
N
)
49
4
3
.
3
6
49
3
5
.
7
6
(
S
)
49
3
2
.
8
0
(
S
W
)
PROPOSED GRADE
EXISTING GRADE
4920
4925
4930
4935
4940
4945
4950
4920
4925
4930
4935
4940
4945
4950
129+00 130+00 131+00 131+50
ST
A
=
1
3
0
+
3
1
.
0
0
IN
L
E
T
C
5
A
10
'
C
D
O
T
T
Y
P
E
R
I
N
L
E
T
TB
C
=
4
9
4
4
.
0
7
IN
V
O
U
T
(
1
8
"
S
E
)
=
4
9
3
7
.
5
5
DE
P
T
H
=
6
.
5
1
18''RCP
5.99 LF
@ 1.00%
18''RCP
22.00 LF
@ 1.00%
ST
A
=
1
3
0
+
0
0
.
0
0
IN
L
E
T
C
5
.
1
15
'
T
Y
P
E
1
6
C
O
M
B
O
I
N
L
E
T
TB
C
=
4
9
4
4
.
0
6
IN
V
O
U
T
(
1
8
"
N
W
)
=
4
9
3
7
.
7
1
DE
P
T
H
=
6
.
3
5
ST
A
=
1
1
8
+
7
4
.
3
9
(
S
T
O
R
M
C
)
ST
A
=
1
3
0
+
2
3
.
5
0
S
T
O
R
M
C
5
SD
M
H
C
5
7'
Ø
F
L
A
T
T
O
P
M
H
RI
M
=
4
9
4
3
.
8
7
IN
V
I
N
(
4
8
"
N
E
)
=
4
9
3
4
.
9
9
IN
V
I
N
(
1
8
"
N
W
)
=
4
9
3
7
.
4
9
IN
V
I
N
(
1
8
"
S
E
)
=
4
9
3
7
.
4
9
IN
V
O
U
T
(
5
4
"
S
W
)
=
4
9
3
4
.
4
9
DE
P
T
H
=
9
.
3
7
100 yr HGL
18
"
M
I
N
.
PROPOSED GRADE
EXISTING GRADE
4925
4930
4935
4940
4945
4950
4955
4925
4930
4935
4940
4945
4950
4955
139+00 140+00 141+00 142+00
30''RCP
56.25 LF
@ 0.50%
ST
A
=
1
4
0
+
5
9
.
8
2
IN
L
E
T
C
6
.
1
6'
D
O
U
B
L
E
T
Y
P
E
1
6
C
O
M
B
O
I
N
L
E
T
TB
C
=
4
9
4
6
.
0
7
IN
V
I
N
(
2
4
"
N
E
)
=
4
9
3
7
.
9
8
IN
V
O
U
T
(
3
0
"
N
W
)
=
4
9
3
7
.
4
8
DE
P
T
H
=
8
.
5
9
24''RCP
31.94 LF
@ 0.50%
ST
A
=
1
4
0
+
9
1
.
7
5
IN
L
E
T
C
6
.
2
15
'
T
Y
P
E
1
6
C
O
M
B
O
I
N
L
E
T
TB
C
=
4
9
4
5
.
9
9
IN
V
O
U
T
(
2
4
"
S
W
)
=
4
9
3
8
.
1
4
DE
P
T
H
=
7
.
8
6
ST
A
=
1
2
0
+
1
5
.
5
0
(
S
T
O
R
M
C
)
ST
A
=
1
4
0
+
0
0
.
0
0
S
T
O
R
M
C
6
SD
M
H
C
6
8'
Ø
M
H
RI
M
=
4
9
4
5
.
6
9
IN
V
I
N
(
4
8
"
N
E
)
=
4
9
3
5
.
7
0
IN
V
I
N
(
3
0
"
S
E
)
=
4
9
3
7
.
2
0
IN
V
O
U
T
(
4
8
"
S
W
)
=
4
9
3
5
.
7
0
DE
P
T
H
=
9
.
9
9
STA=140+81.08
TOP=4936.34
8"WATER CROSSING
STA=140+67.14
INV=4931.83
8"SANITARY CROSSING
HGL
100 yr HGL
SD09
JEP
CMG
Date Issue /Description#
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY,AND MAY NOT BE DUPLICATED,
DISCLOSED,OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF THE
ARCHITECT.COPYRIGHTS AND
INFRINGEMENTS WILL BE ENFORCED AND
PROSECUTED.
3760 E.15th Street,Suite 202
Loveland,CO 80538
970.800.3300 O
www.gallowayUS.com
C 2015.Galloway &Company,Inc.All Rights Reserved
Init.
OF 188 SHEETS
SHEET TITLE:
Date:
Drawn By:
Project No:
Checked By:
HFHLV0001.01
12.05.16
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath,CO 80547
970.674.1109
KEYMAP
STA:
SCALE:H:1"=V:1"=
toSTORMDRAINC3120+00.00 120+39.24
50 5
STA:
SCALE:H:1"=V:1"=
toSTORMDRAINC5130+00.00 130+31.00
50 5
STA:
SCALE:H:1"=V:1"=
toSTORMDRAINC6140+00.00 140+91.75
50 5
SD09
LEGEND:
NOTES:
1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY.IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES,PUBLIC OR PRIVATE,WHETHER SHOWN ON THE PLANS OR NOT,PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION.
2.JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER
THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES.LAYING
LENGTH INCLUDES FLARED END SECTIONS.
4.RCP SHALL BE CLASS III OR GREATER.PIPE MATERIAL,BEDDING,AND INSTALLATION WITHIN PUBLIC
RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS.ALTERNATES (SUCH AS ADS N-12 OR
HP SANITITE)OUTSIDE OF THE R.O.W.SHALL BE APPROVED IN ADVANCE BY THE ENGINEER.ALL JOINTS
SHALL BE 'WATERTIGHT'USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER
ASTM F477 /D3212 FOR PLASTIC PIPE).
5.ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
6.MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3.CONTRACTOR SHALLVERIFY THAT
MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e.,WITHIN PRE-CASTER'S TOLERANCES,ETC.).
7.SEE DETAILS FOR RIPRAP PAD SIZING.
8.PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE.
9.MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED.
10.SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY.SEE SHEET SS01-SS35 FOR FINAL
ELEVATIONS.
11.WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY.THE CONTRACTOR SHALL VERIFY THAT 18"
VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS.
12.SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES.
13.ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER,CROSSPANS AND SIDEWALKS.
14.MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14"BELOW FINISHED GRADE IN PAVED AREAS.
15.SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL.
16.THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE
APPROVED LANDSCAPE PLAN.
S
PROPOSED STORM INLET
EASEMENT LINE
PROPOSED LOTLINE
PROPOSED RIGHT-OF-WAY
PROPERTY BOUNDARY
PROPOSED CURB &GUTTER
EXISTING GAS
EXISTING OVER-HEAD ELECTRIC
PROPOSED FIBER OPTIC
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED FIRE HYDRANT
PROPOSED RESIDETIAL SERVICE
PROPOSED SEWER SERVICE
EXISTING SANITARY SEWER
PROPOSED SANITARY SEWER
EXISTING WATER MAIN
PROPOSED WATER MAIN W 8"
SS SSSS8"
4900
4900
PROPOSED CONTOUR
EXISTING CONTOUR
PROPOSED WATER LINE LOWERING
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG,GRADE,OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
R
(IN FEET )
1 inch =ft.
050 50
50
100 150
49
3
6
.
5
3
49
4
3
.
4
3
37.10 LF
2.08%
37.10 LF
2.08%
AB 12.18.17 Record Drawings JEP
INV OUT (24"S)=4912.20 4912.48
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E.LOCKWOOD,PLS
PLS.0038316
DATED:10.05.17
49
3
4
.
5
0
AB2 01.18.19 Record Drawings JEP
INV OUT (24"S)=4912.20 4912.48
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E.LOCKWOOD,PLS
PLS.0038316
DATED:01.10.19
49
3
7
.
5
4
49
3
7
.
2
5
49
3
5
.
0
0
49
4
3
.
9
0
18.50 LF
@ 1.41%
49
3
7
.
8
0
49
4
4
.
1
0
49
3
7
.
3
9
FL
=
4
9
4
3
.
5
3
9.50 LF
@ 1.47%
18.50 LF @ 1.41%
9.50 LF @ 1.47%
49
3
8
.
1
0
FL
=
4
9
4
5
.
4
2
49
3
7
.
6
4
49
3
7
.
8
6
FL
=
4
9
4
4
.
4
5
49
3
5
.
7
6
49
3
7
.
3
4
49
3
5
.
7
6
49
4
5
.
8
4
55.10 LF
@0.54%
29.20 LF
@ 0.82%
29.20 LF
@ 0.82%
55.10 LF
@ 0.54%
10
'
C
D
O
T
T
Y
P
E
R
I
N
L
E
T
15
'
T
Y
P
E
1
6
C
O
M
B
O
I
N
L
E
T
1/19 Page 5
V. Storm Drain Inlets - FCSCM Ch. 9, Sec. 3.0
A. Construction/Installation: All storm drain inlets have been constructed in accordance with the
approved construction plans and construction specifications.
1. The size and type of inlets are consistent with the inlets shown on the approved construction
plan. Indicate by writing “Verified” on each inlet on the plan sheet or list on a separate document the
inlet number(s), type and size (length). If the inlet installed is other than the one on the approved
construction plan detail sheet, provide the name and source of the detail with justification for equal or
better capacity.
2. The size of the inlet opening is consistent with the approved detail. (Check height and width.)
3. The elevation of the grate (if applicable) is at the elevation shown on the street profile or as
indicated by a spot elevation on the construction plans.
4. The as-built invert elevations of all pipes entering and leaving the inlet are shown on the plan
and profile sheets within construction tolerance of 0.2 feet. If substantially different, provide
justification and capacity calculations to show the capacity is not affected or propose mitigation.
5. The as-built size of the inlet box is as shown on the construction plans or an explanation or
justification is attached.
6. All Type C, R, 13 and 16 inlet covers are stenciled or stamped with the following designation (or
an equivalent): NO DUMPING – DRAINS TO POUDRE RIVER.
VI. Culverts - FCSCM Ch. 9, Sec. 4.0
A. Construction/Installation: All culverts have been constructed and/or installed in accordance with
the approved construction plans and construction specifications.
1. All culvert sizes have been verified as indicated on the as-built construction plans as correct.
2. The culvert material type for all culverts installed is as on the approved construction plans and is
indicated on the as-built plans.
3. The as-built invert “in and out” elevations have been verified and are indicated on the as-built
construction plans.
4. The culvert headwalls or wing walls have been installed as shown on the approved construction
plans. Headwalls or wing walls may be needed in the as-built conditions onsite if the slopes adjacent to
the culvert are greater than 4:1. Please note areas needing stabilization in the certification narrative.
An alternative to consider is a turf reinforcement mat (TRM).
VII. Sub-Drains
A. Construction/Installation: All sub-drains shown on the construction plans have been installed in
accordance with those plans and the construction specifications. Sub-drains installed with the sanitary
sewer are to be verified on the sanitary sewer plan and profile sheets of the construction plans. (NOTE:
Indicate any sub-drains installed after the plans were approved on the as-built plans.)
1. The size of the sub-drains are as approved on the construction plans and are indicated on the as-
built plans.
2. The type of sub-drain, in particular the perforated and non-perforated sections of the drain, are
as indicated on the approved construction plans.
1
Herman Feissner
From:Heather McDowell <hmcdowell@fcgov.com>
Sent:Friday, November 2, 2018 11:30 AM
To:Herman Feissner; Wayne Lenard
Cc:jweber@crc-co.net
Subject:RE: East Ridge Second Filing | Storm Drain System C - Inlets C5A and C5.1
All, I’m fine with you proceeding as requested. Thanks,
Heather McDowell, P.E.
Water Utilities Engineering
City of Fort Collins
Office 970.224.6065
Mobile 970.218.9225
hmcdowell@fcgov.com
From: Herman Feissner <HermanFeissner@gallowayus.com>
Sent: Wednesday, October 31, 2018 9:57 AM
To: Heather McDowell <hmcdowell@fcgov.com>
Cc: jweber@crc-co.net
Subject: East Ridge Second Filing | Storm Drain System C - Inlets C5A and C5.1
Hi Heather,
I received a call on October 30th, 2018 from Jarrod Weber (Coyote Ridge Construction) about INLET C5A and INLET C5.1
(see below).
2
INLET C5.1 was installed on the west curb line and INLET C5A on the east curb line –opposite the approved construction
documents. I checked the capacity as-constructed and support leaving the inlets in the as-constructed condition. During
the minor storm event, the inlets have capacity for minor flows without overtopping the centerline; and during the major
storm event, the inlets function as designed (i.e., capacity checked at 6.5” depth at FL, 1.4” depth at the CL – the same
criteria I applied in the approved Final Drainage Report).
I’ll follow-up this message during the Overall and Site and Drainage Certification process for Phase 4 by noting the
change from the approved construction documents.
Can you follow-up with the field inspector and make him aware that I contacted you and support leaving the inlets as-
constructed.
Please let me know if you have questions.
Herman
Galloway
Herman
Feissner, PE
SR. CIVIL PROJECT ENGINEER
5265 Ronald Reagan Blvd., Suite 210
Johnstown,CO 80534
O 970.800.3300
3
HermanFeissner@GallowayUS.com
GallowayUS.com
COLORADO | CALIFORNIA | UTAH
Nationally Recognized. Locally Preferred.
1/19 Page 6
3. The cover requirements per the construction plans are provided.
4. The cleanouts have been installed at the locations shown on the construction plans and are
accessible for cleaning. (Cleanouts can be buried a maximum of 6 inches deep with their locations
marked.)
5. The backfill materials for sub-drains are as shown on the approved construction plans. (This
includes the type, depth and width.)
6. The geo-textile liner completely wraps the sub-drain and the permeable backfill material unless
shown otherwise on the approved construction plans. (Sub-drain pipe wrapped in a sock filter material
is accepted only if approved prior to installation.)
VIII. Curb Cuts
A. Construction: All curb cut openings are constructed in accordance with the approved construction
plans and construction specifications.
1. The size (width) of the curb cut opening is as shown on the approved construction plans.
2. The curb cut openings tie into a downstream swale, pipe, or other appurtenances with a smooth
transition and there no obstructions such as riprap or sod impeding the flow downstream of the curb
cut.
IX. Sidewalk Culverts & Chases
A. Construction/Installation: All sidewalk culverts have been installed at the locations shown on the
approved construction plans.
1. The size (width and length) of the culverts are as shown on the approved construction plans.
2. The cover plate is a minimum 5/8-inch galvanized plate bolted to a galvanized angle iron per the
detail shown on the approved construction plans or per the City’s detail.
3. The sidewalk culvert invert “in and out” elevations have been verified and are indicated on the
as-built plans.
4. The sidewalk culvert opening is as shown on the approved construction plans or per the City’s
detail.
5. There is a smooth transition both on the inlet and outlet ends of the sidewalk culvert with no
obstructions such as riprap or sod impeding the flow into or out of the sidewalk culvert.
X. Site Grading - FCSCM Ch. 8
A. Construction: All common open spaces have been graded in accordance with the approved
construction plans.
1. The grading on all common open spaces bordering private lots has been verified as correct and
the as-built rear lot corner elevations have been shown on the as-built plans.
ZEPPELINWAY
CONQUESTSTREET
53'R.O.W.
30'-
9'UTIL
EASEMENT
53'R.O.W.
30'-
9'UTIL
EASEMENT
9'UTIL
EASEMENT
53'R.O.W.
30'-
9'UTILEASEMENT
9'UTILEASEMENT
45.26
2.2%
2.3%
2.4%
2.2%
2.6%
2.6%
1.2%
1.8%
3.9%
0.6%
0.6%
45.06
2.0%
2.0%
45.37
1.2%
1.8%
45.96
45.93
30'
44.82
2.3%
2.4%
LOT 9
LOT 9
LOT 8
44.96
53'R.O.W.30'-
9'UTILEASEMENT
9'UTILEASEMENT
53'R.O.W.30'-
9'UTILEASEMENT
9'UTILEASEMENT
53'R.O.W.
30'-
9'UTIL
EASEMENT
9'UTIL
EASEMENT
53'R.O.W.
30'-
9'UTIL
EASEMENT
9'UTIL
EASEMENT
R20'
R20'
R20'
R20'
0.7%
0.7%
0.7%
0.7%
1.5%
1.0%
0.3%
2.3%2.2%
0.8%
0.7%
0.7%
0.8%
1.6%
0.5%
0.1%
2.5%2.3%
CONQUESTSTREET
LOT 1
LOT 10
45.45
45.48
0.6%
2.3%
2.1%
2.1%
2.1%
72'
75'
0.5%
45.17
45.06
44.99
45.43
45.52
LOT 8
LOT 1
LOT 11
LOT 7
QUINBY
STREET
CONQUEST STREET
R20'R20'
R20'R20'2.2%
2.3%
1.4%
0.6%
2.2%
2.2%
1.4%
0.6%
30'-
53'R.O.W.
9'UTILITY
EASEMENT
9'UTIL
EASEMENT
30'-
30'
-
53'
R.O.W.
9'
UTILITY
EASEMENT
9'
UTIL
EASEMENT
53'
R.O.W.
9'
UTILITY
EASEMENT
9'
UTIL
EASEMENT
0.6%
1.5%1.4%
0.5%
0.7%
0.5%
2.3%
2.1%
2.2%
2.2%
50'
2.3%
2.3%
53'R.O.W.
9'UTIL
EASEMENT
9'UTIL
EASEMENT
2.3%
2.3%
LOT 8LOT 9
LOT 5 LOT 6 LOT 7
CONQUEST STREET
FAIRCHILD
STREET
53'R.O.W.
30'-9'UTIL
EASEMENT
9'UTIL
EASEMENT
53'
R.O.W.
30'
-
9'
UTIL
EASEMENT
9'
UTIL.
EASEMENT
53'
R.O.W.
30'
-
9'
UTIL.
EASEMENT
9'
UTIL
EASEMENT
R20'
R20'
75'
1.8%
1.1%
2.2%
2.1%
2.3%
2.3%
2.3%
2.3%
2.0%2.0%2.0%2.0%
2.0%
0.3%
CON
BLOCK 5
CONQUEST
WAY
57'R.O.W.
36'-
9'UTIL
EASEMENT
20'
R.O.W.
2.4%
2.4%
2.4%
2.4%
2.4%
2.4%
2.4%
2.4%
0.8%
0.8%
0.8%
ALLEY A
46.68
9'UTIL
EASEMENT
0" CURB FACE
TRANSITION
TO ROLLOVER
SIDEWALK CHASE
6" CURB FACE TO
0" CURB FACE
TRANSITION
36'-
57'R.O.W.
9'UTIL
EASEMENT
9'UTIL
EASEMENT
46.72
8'
UTIL
EASEMENT
8'
UTIL
EASEMENT
1.0%
1.2%
1.3%VICOT
WAY
53'R.O.W.
30'-9'UTIL
EASEMENT
53'R.O.W.
30'-9'UTIL
EASEMENT
9'UTIL
EASEMENT
LOT 7
LOT 6
LOT 1
LOT 15
2.2%
2.3%
2.3%
2.3%ALLEY A
ALLEY A
6" CURB FACE TO
0" CURB FACE
TRANSITION
0" CURB FACE
TRANSITION
TO ROLLOVER
9'UTIL
EASEMENT
SIDEWALK
CHASE
0.6%
0.6%
0.6%
0.6%
45.02
45.18
45.25 45.23
20'
R.O.W.
8'
UTIL
EASEMENT
8'
UTIL
EASEMENT
20'
R.O.W.
8'
UTIL
EASEMENT
8'
UTIL
EASEMENT
2.2%
2.2%45.12
2.2%1.1%
0.8%
0.8%
43.60
ZEPPELINWAY
53'R.O.W.
30'-
9'UTILEASEMENT
9'UTILEASEMENT
53'R.O.W.
30'-
9'UTILEASEMENT
9'UTILEASEMENT
20'R.O.W.
43.59
43.78
2.3%
2.2%
2.5%
2.5%
0.6%
0.7%
0.6%
0.6%
6" CURB FACE TO
0" CURB FACE
TRANSITION
0" CURB FACE
TRANSITION
TO ROLLOVER
SIDEWALK
CHASE
ALLEY A
ALLEY A
44.21
43.82
20'R.O.W.
8'UTIL
EASEMENT
8'UTIL
EASEMENT
8'UTIL
EASEMENT
8'UTIL
EASEMENT
44.11
43.74
2.0%
1.5%
44.22
1.3%
1.3%
43.18
43.35
RD50
JEP
CMG
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2.REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3.ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4.CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5.CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6.SEE DETAIL SHEET DT14 FOR LOT TEMPLATES.
7.4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
8.SEE SECTION 3.4.1 OF LANDUSE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE.
9.REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
10. LAND USE FOR THE WETLANDS AND THE UPLAND HABITATS SHALL BE MAINTAINED AS PART OF THE HOA. SEE LANDSCAPE PLANS
FOR INTENDED USES. /LANDSCAPING AND PLANTING
11. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
12. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
13. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN.
14. MOE: INDICATES MINIMUM OPEN ELEVATION APPLICABLE TO MAIN FLOOR OF RESIDENCE AND GARAGE AND SHALL BE MINIMUM 12"
ABOVE HIGH SIDE FRONT LOT CORNER.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND:NOTES:
4900
4900
LOT TEMPLATE A B
Date Issue / Description#
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF THE
ARCHITECT. COPYRIGHTS AND
INFRINGEMENTS WILL BE ENFORCED AND
PROSECUTED.
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2015. Galloway & Company, Inc. All Rights Reserved
Init.
OF 188 SHEETS
SHEET TITLE:
Date:
Drawn By:
Project No:
Checked By:
HFHLV0001.01
12.05.16
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
KEYMAP
DateCity Engineer
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
APPROVED:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
CHECKED BY:
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
R
RD50
S
RD50 T
RD50
U
RD50
V
RD50
W
RD50
X
RD50
ZEPPELIN WAY & CONQUEST STREET
(FOR PLAN AND PROFILES SEE SHEETS RD12 & RD09)
R
RD50
MARQUISE STREET & CONQUEST STREET
(FOR PLAN AND PROFILES SEE SHEETS RD21 & RD10)
S
RD50
CONQUEST STREET & QUINBY STREET
(FOR PLAN AND PROFILES SEE SHEETS RD11 & RD29)
T
RD50
ZEPPELIN WAY & ALLEY A
(FOR PLAN AND PROFILES SEE SHEETS RD12 & RD32)
X
RD50
VICOT WAY & ALLEY A
(FOR PLAN AND PROFILES SEE SHEETS RD05 & RD32)
W
RD50
CONQUEST WAY & ALLEY A
(FOR PLAN AND PROFILES SEE SHEETS RD11 & RD32)
V
RD50
FAIRCHILD STREET & CONQUEST STREET
(FOR PLAN AND PROFILES SEE SHEETS RD16 & RD11)
U
RD50
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E. LOCKWOOD, PLS
PLS.0038316
DATED: 05.09.19
43.51
AB3 05.09.19 Record Drawings JEP
LOT 12
LOT 1
SYKES DRIVE
CONQUEST
WAY
76'R.O.W.
50'-
9'UTIL
EASEMENT
9'UTIL
EASEMENT
46.07
R2.5'
R2.5'
36'-
57'R.O.W.
9'UTIL
EASEMENT
9'UTIL
EASEMENT
2.4%
2.4%
2.2%
2.3%
C2
L3
C3
2.3%
2.2%
1.3%
0.2%
75.01'
0.6%
0.6%
0.6%
0.6%
1.5%
2.2%
2.3%
1.0%
ACCESSEASEMENTBY
SEPARATEDOCUMENT
LOT 10
LOT 1 BL
ALLEYA
53'R.O.W.30'-
9'UTILEASEMENT
9'UTILEASEMENT
53'R.O.W.
30'-
9'UTILEASEMENT
ALLEYA
20'R.O.W.
LOT 11
2.3%
2.3%
0.8%
0.6%
0.7%
0.7%
6" CURB FACE TO
0" CURB FACE
TRANSITION
0" CURB FACE
TRANSITION
TO ROLLOVER
SIDEWALK
CHASE9'UTILEASEMENT 2.3%
2.3%
44.42
20'R.O.W.
8'UTIL
EASEMENT
8'UTIL
EASEMENT
8'UTIL
EASEMENT
8'UTIL
EASEMENT
44.91
44.27
1.58%2.02%
1.0%
BLOCK 24
QUINBY
STREET
ALLEY A
20'
R.O.W.
20'
R.O.W.
9'UTIL
EASEMENT
LOT 11 LOT 1
LO
LOT 12
2.2%
2.3%
0.7%
0.7%
0.7%
0.7%
ALLEY A
2.2%
2.3%6" CURB FACE
TO
0" CURB FACE
TRANSITION
0" CURB FACE
TRANSITION
TO ROLLOVER
SIDEWALK
CHASE
53'R.O.W.
9'UTIL
EASEMENT
9'UTIL
EASEMENT
30'-
53'R.O.W.
9'UTIL
EASEMENT
30'-
47.37
47.39
8'
UTIL
EASEMENT
8'
UTIL
EASEMENT
8'
UTIL
EASEMENT
8'
UTIL
EASEMENT
ALLEY A
ALLEY
A
R16'
R33.58'
20'
R.O.W.
2.4%0.1%
2.0%
2.2%
8'
UTIL
EASEMENT
8'
UTIL
EASEMENT
LOT 2
LOT 1
LOT 7 LOT 15
SYKES DRIVE
VICOT
WAY
76'
R.O.W.
50'
-
9'
UTIL
EASEMENT
76'
R.O.W.
50'
-
9'
UTIL
EASEMENT
9'
UTIL
EASEMENT
R20'
R20'
2.5%2.0%
57'R.O.W.
36'-
9'UTILEASEMENT
9'UTILEASEMENT
2.2%
2.2%
0.8%
0.2%
0.6%
44.38
44.37
0.6%0.6%0.6%
44.43
44.45
0.7%0.7%0.6%0.6%
2.2%
2.3%
2.5%
2.5%
2.2%
2.3%
1.2%
0.0%
LOT 7 LOT 15
75'
0.3%1.3%
75'
1.4%
0.4%
53'R.O.W.
30'-9'UTIL
EASEMENT
9'UTIL
EASEMENT
ACCESS
EASEMENTBY
SEPARATE
DOCUMENT
0.8
0.8%
SYKES DRIVE
76'R.O.W.
50'-
9'UTIL
EASEMENT
76'
R.O.W.
50'
-
9'
UTIL
EASEMENT
20'PRIVATEDRIVE
2.2%
2.2%
2.3%
2.3%
2.2%
2.3%
0.1%
0.3%
0.1%
0.2%
RD51
JEP
CMG
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED PAN
EXISTING CONTOUR
PROPOSED CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE
EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT,
PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY
LOCATION.
2.REFER TO THE PLAT FOR LOT, TRACT, EASEMENTS AND OTHER SURVEY INFORMATION.
3.ELEVATIONS SHOWN HAVE BEEN ABBREVIATED. THE ENTIRE ELEVATION IS THE ELEVATION SHOWN PLUS 4900 FEET (43.71 = 4943.71).
4.CONTOURS SHOWN OUTSIDE OF STREET RIGHT-OF-WAY ARE OVERLOT CONTOURS. CONTOURS SHOWN WITHIN THE STREET
RIGHT-OF-WAY ARE FINISHED GRADE.
5.CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE LOT CORNERS, OVERLOT OR FINISHED GRADE FOR
LANDSCAPE AREAS.
6.SEE DETAIL SHEET DT14 FOR LOT TEMPLATES.
7.4:1 MAX TIE TO EXISTING SURFACE AT END OF PHASE IF REQUIRED.
8.SEE SECTION 3.4.1 OF LANDUSE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE.
9.REVEGETATION SHALL BE PER THE APPROVED LANDSCAPE PLAN.
10. LAND USE FOR THE WETLANDS AND THE UPLAND HABITATS SHALL BE MAINTAINED AS PART OF THE HOA. SEE LANDSCAPE PLANS
FOR INTENDED USES. /LANDSCAPING AND PLANTING
11. FHA GRADING SHOWN FOR REFERENCE ONLY. LOT SPECIFIC PLOT PLANS TO BE SUBMITTED TO THE CITY FOR APPROVAL ONCE
INDIVIDUAL FOOTPRINTS ARE DETERMINED.
12. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR
STORM.
13. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN.
14. MOE: INDICATES MINIMUM OPEN ELEVATION APPLICABLE TO MAIN FLOOR OF RESIDENCE AND GARAGE AND SHALL BE MINIMUM 12"
ABOVE HIGH SIDE FRONT LOT CORNER.
PROPOSED STORM INLET
2.0%
(47.45)
EXISTING SPOT ELEVATION
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
PROPOSED RIGHT OF WAY
LEGEND:NOTES:
4900
4900
LOT TEMPLATE A B
Date Issue / Description#
THESE PLANS ARE AN INSTRUMENT OF
SERVICE AND ARE THE PROPERTY OF
GALLOWAY, AND MAY NOT BE DUPLICATED,
DISCLOSED, OR REPRODUCED WITHOUT
THE WRITTEN CONSENT OF THE
ARCHITECT. COPYRIGHTS AND
INFRINGEMENTS WILL BE ENFORCED AND
PROSECUTED.
3760 E. 15th Street, Suite 202
Loveland, CO 80538
970.800.3300 O
www.gallowayUS.com
C 2015. Galloway & Company, Inc. All Rights Reserved
Init.
OF 188 SHEETS
SHEET TITLE:
Date:
Drawn By:
Project No:
Checked By:
HFHLV0001.01
12.05.16
EAST RIDGE HOLDINGS
4801 Goodman Rd.
Timnath, CO 80547
970.674.1109
KEYMAP
BB
RD51
V
RD50
CC
RD51 DD
RD51
Y
RD51
Z
RD51
AA
RD51
ALLEY A & MARQUISE STREET
(FOR PLAN AND PROFILES SEE SHEETS RD33 & RD21)
Y
RD51
ALLEY A & QUINBY STREET
(FOR PLAN AND PROFILES SEE SHEETS RD34 & RD29)
Z
RD51
ALLEY A
(FOR PLAN AND PROFILES SEE SHEET RD34)
AA
RD50
SYKES DRIVE & CONQUEST WAY
(FOR PLAN AND PROFILES SEE SHEETS RD01 & RD10)
BB
RD51
SYKES DRIVE & VICOT WAY
(FOR PLAN AND PROFILES SEE SHEETS RD01 & RD05)
CC
RD51
SYKES DRIVE & PRIVATE DRIVE AA
(FOR PLAN AND PROFILES SEE SHEETS RD02 & RD35)
DD
RD51
1 03/29/17 Utility and Plan Revisions JEP
REPRESENTS RECORD SURVEY DATA
PROVIDED BY NORTHERN ENGINEERING
MATT E. LOCKWOOD, PLS
PLS.0038316
DATED: 05.09.19
43.51
AB3 05.09.19 Record Drawings JEP
1/19 Page 7
2. The as-built contours for “overlot grading” are shown on the as-built construction plans for all
common open spaces, tracts, outlots, etc. If not in compliance, please attach a narrative describing the
situation for noncompliance and when it may be corrected. An escrow for overlot grading may be
required. (NOTE: Residential Lot Grading Certification is a separate process from this Overall Site
Certification. It is understood that residential lots will be brought to final grade once the foundation is
backfilled so they may be lower than the plan shows at this Overall Site Certification stage.)
3. All turf reinforcement mats (TRMs) have been installed as shown on the approved construction
plans and the slopes are stabilized.
XI. Permanent Erosion Control BMPs - FCSCM Ch. 9, Sec. 7.0
A. Construction: All permanent erosion control BMPs have been installed per the approved
construction plans.
1. All riprap has been installed in the locations and sizes indicated on the approved construction
plans.
2. All fabric has been installed in the locations and sizes indicated on the approved construction
plans.
a. All fabric was installed per the details on the approved construction plans.
XII. Post-Construction Site Cleanup - FCSCM Ch. 3, Sec. 2.0
A. Construction: All construction debris and obstructions of any kind have been removed from
drainage paths.
1. All construction debris has been removed except in staging area(s).
2. All ruts have been smoothed out in all construction areas.
3. All areas needing reseeding have been identified and future stabilization goals have been
coordinated with the Erosion Control Inspector and in accordance with FCSCM Vol.2 Chapter 12. Note
the area needing stabilization in the narrative.
XIII. Certification of LID and Water Quality Facilities - FCSCM Ch. 7
A. Attached are the During Construction Inspection Checklist for Low Impact Development (LID) and
other items to be verified during construction, along with pictures and other required documentation.
XIV. Certification of Other Permanent BMPs
A. The construction of other permanent BMPs not specifically addressed in this certification is in
accordance with the approved plan. This may include grade control structures, rundowns, bridges, stream
access/improvements, etc.
Please specify other permanent BMPs included on this site: