Loading...
HomeMy WebLinkAboutSite Certifications - 03/05/201812/15 Page 1 OVERALL SITE and DRAINAGE CERTIFICATION Commercial, Multi-Family and Subdivision Certification Form and Checklist Project Name: Date: Building Permit Numbers: (Commercial or multi-family) Per the requirement in Fort Collins Stormwater Criteria Manual (FCSCM) Volume 1, Section 6.11, please fill in all applicable items in this Certification Form for Commercial, Multi-Family and Overall Single Family sites. NOTE: several items must be verified during construction. A copy of the approved grading plan must be submitted with the as-built grading plan. (As-built elevations must be written in red next to the approved elevations.) •Use “Yes” for items completed as described. •Use “N/A” for items that are not applicable to the site being certified. •If any blanks are “No,” attach an explanation referencing the item number below. Attach an explanation or description of the as-built condition for any items listed or for anything not listed but shown on the approved construction plans. Provide an as-built redline or Mylar drawing with the following: I.Water Quality and Quantity Detention Basin Certification - FCSCM Vol.2, Ch.10 For multiple detention basins on a site, provide the following for each basin separately: A. Volume: As-built topographic verification is attached at 1-foot (or less) contour intervals and volume verification calculations for the water quality capture volume and the 100-year detention storage volume. 1. Detention basin topography was prepared by a professional land surveyor registered in the state of Colorado. 2.Both proposed and as-built contours are shown on the same plan sheet (dashed lines for proposed and solid lines for as-built). 3.All critical spot elevations as shown on the approved construction plans have been verified and the as-built elevations are shown on the plan sheet. 4.Stage-storage-discharge tables are provided on a separate document. 5.Verification that designed drain time is in compliance with Colorado Revised Statute § 37-92- 602(8) is attached and has been uploaded to the Statewide Compliance Portal (tinyurl.com/COCompliancePortal) for approval. Uploaded documents must include: a.The cover sheet from the approved drainage report b.The stamped certification page from the approved drainage report c.As-built topographic survey d.Stamped certification page from the Overall Site & Drainage Certification e.PDF output from the Stormwater Detention and Infiltration Design Data Speadsheet Stormwater Facility Name: Facility Location & Jurisdiction: User (Input) Watershed Characteristics User Defined User Defined User Defined User Defined Watershed Slope =0.010 ft/ft Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs] Watershed Length-to-Width Ratio =1.00 L:W 0.00 0 0.00 0.00 Watershed Area =153.29 acres 0.44 0 0.44 0.00 Watershed Imperviousness =70.0%percent 0.66 103,233 0.66 5.00 Percentage Hydrologic Soil Group A =percent 1.66 129,505 1.66 5.00 Percentage Hydrologic Soil Group B =percent 2.66 150,774 2.66 5.00 Percentage Hydrologic Soil Groups C/D =100.0%percent 3.66 191,525 3.66 5.00 4.66 240,819 4.66 5.00 User Input 17 5.66 278,239 5.66 5.00 7.66 297,045 7.66 5.00 8.66 318,064 8.66 5.00 User Input: Detention Basin Characteristics 9.66 343,140 9.66 5.00 WQCV Design Drain Time =40.00 hours After completing and printing this worksheet to a pdf, go to: https://maperture.digitaldataservices.com/gvh/?viewer=cswdif create a new stormwater facility, and attach the pdf of this worksheet to that record. Routed Hydrograph Results Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 50 Year 100 Year One-Hour Rainfall Depth =0.43 0.88 1.16 1.47 2.48 3.05 in Calculated Runoff Volume =3.5 7.7 11.2 15.0 28.1 35.8 acre-ft OPTIONAL Override Runoff Volume =acre-ft Inflow Hydrograph Volume =3.475 7.669 11.200 15.025 28.048 35.812 acre-ft Time to Drain 97% of Inflow Volume =8.4 18.2 26.5 35.4 66.0 84.2 hours Time to Drain 99% of Inflow Volume =8.8 18.6 27.1 36.1 67.3 85.9 hours Maximum Ponding Depth =1.64 2.89 3.75 4.52 6.63 7.78 ft Maximum Ponded Area =2.958 3.668 4.481 5.360 6.594 6.87 acres Maximum Volume Stored =2.854 6.930 10.417 14.229 27.184 34.9 acre-ft Location for 1-hr Rainfall Depths (use dropdown): Workbook Protected Worksheet Protected Stormwater Detention and Infiltration Design Data Sheet East Ridge Second Filing (As-Built w/Interim Outfall) Fort Collins, Colorado HFHLV0001.01_SDI_Design_Data_v1.03_As-Built.xlsm, Design Data 1/24/2018, 12:01 PM Doing_Clear_Formatting =Yes CountA=1 0 1 2 3 #N/A #N/A 0 1 2 3 #N/A #N/A Check Data Set 1 Check Data Set 1 Area Discharge Stormwater Detention and Infiltration Design Data Sheet 0 100 200 300 400 500 600 700 800 900 0.1 1 10 FL O W [ c f s ] TIME [hr] 100YR IN 100YR OUT 50YR IN 50YR OUT 10YR IN 10YR OUT 5YR IN 5YR OUT 2YR IN 2YR OUT WQCV IN WQCV OUT 0 1 2 3 4 5 6 7 8 9 0.1 1 10 100 PO N D I N G D E P T H [ f t ] DRAIN TIME [hr] 100YR 50YR 10YR 5YR 2YR WQCV HFHLV0001.01_SDI_Design_Data_v1.03_As-Built.xlsm, Design Data 1/24/2018, 12:01 PM Project:East Ridge Second Filing Project Location:Fort Collins, Colorado Date: 1/10/2018 Calculations By:H. Feissner Pond Description:Detention Pond User Input Cell:Blue Text Required Volume, ac-ft Water Surface Elevation, ft Design Point:Outfall Design Storm:WQCV Approved Elevation Required Volume:0 ft3 N/A 4928.34 4928.50 Design Storm:2-year Required Volume:106010 ft3 2.4 4929.72 4929.79 Design Storm:1st 100-year Required Volume:1542290 ft3 35.4 4936.07 4936.11 Design Storm1:2nd 100-year Required Volume:3084580 ft3 70.8 4939.98 4940.01 1. 2nd 100-year storm required per Section 3.3.4 Retention Facilities of the FCSCM Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4927.90 0 0.0 0 0 0 0 4928.34 0 0.4 0 0 0 0 0.0 4929.00 103233 0.7 34067 34067 22711 22711 0.5 4930.00 129505 1.0 116369 150436 116121 138833 3.2 4931.00 150774 1.0 140140 290576 140005 278838 6.4 4932.00 191525 1.0 171149 461725 170744 449581 10.3 4933.00 240819 1.0 216172 677897 215702 665284 15.3 4934.00 278239 1.0 259529 937427 259304 924588 21.2 4935.00 297045 1.0 287642 1225068 287591 1212178 27.8 4936.00 318064 1.0 307554 1532622 307494 1519672 34.9 4937.00 343140 1.0 330602 1863224 330523 1850195 42.5 4938.00 382808 1.0 362974 2226199 362794 2212989 50.8 4939.00 437117 1.0 409963 2636162 409663 2622651 60.2 4940.00 503560 1.0 470339 3106500 469947 3092599 71.0 4941.00 757558 1.0 630559 3737059 626252 3718850 85.4 Not Closed 100-year storage voume, 35.4 ac-ft, provided at elev.4936.07 Detention Pond AS-BUILT Stage-Storage Calculations Average End Area Method: Design Storm Required Volume, ft3 Conic Volume Method: 1st 100-year 2nd 100-year 4926 4928 4930 4932 4934 4936 4938 4940 4942 0 500000 1000000 1500000 2000000 2500000 3000000 3500000 4000000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Detention Pond Project:East Ridge Second Filing Project Location:Fort Collins, Colorado Date: 12/19/2017 Calculations By:H. Feissner Pond Description:SF for B, E and F Basins User Input Cell:Blue Text Design Point:Outfall Design Storm:WQCV Approved Elevation Required Volume:32747 ft3 4933.87 4933.93 Design Storm:10-year Required Volume:0 ft3 N/A N/A Design Storm:100-year Required Volume:0 ft3 N/A N/A Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4931.00 7404 0.0 0 0 0 0 0.00 4932.00 10502 1.0 8953 8953 8908 8908 0.20 4933.00 12876 1.0 11689 20642 11669 20577 0.47 4934.00 15314 2.0 25817 34770 25666 34574 0.79 Sand Filter (SF) | B, E, F and Fut-B Basins AS-BUILT Stage-Storage Calculations Required Volume Water Surface Elevation Average End Area Method:Conic Volume Method: WQCV 4931 4932 4933 4934 4935 0 5000 10000 15000 20000 25000 30000 35000 40000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Sand Filter (SF) Tributary area includes the B, E and F developed basins plus the Fut-B basins Project:East Ridge Second Filing Project Location:Fort Collins, Colorado Date: 12/19/2017 Calculations By:H. Feissner Pond Description:EDB for C and D Basins User Input Cell:Blue Text Design Point:Outfall Design Storm:WQCV Approved Elevation Required Volume:26572 ft3 4931.55 4931.78 Design Storm:10-year Required Volume:0 ft3 N/A N/A Design Storm:100-year Required Volume:0 ft3 N/A N/A Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4928.56 0 0.0 0 0 0 0 0.00 4929.00 5303 0.4 1167 1167 778 778 0.02 4930.00 9899 1.0 7601 8768 7483 8260 0.19 4931.00 12187 1.0 11043 19811 11023 19284 0.44 4932.00 14433 1.0 13310 33121 13294 32578 0.75 Extended Detantion Basin (EDB) | C and D Basins AS-BUILT Stage-Storage Calculations Required Volume Water Surface Elevation Average End Area Method:Conic Volume Method: WQCV 4928 4929 4930 4931 4932 4933 0 5000 10000 15000 20000 25000 30000 35000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Sand Filter (SF) Tributary area includes the C and D developed basins Project:East Ridge Second Filing Project Location:Fort Collins, Colorado Date: 12/19/2017 Calculations By:H. Feissner Pond Description:EDB for G and H Basins User Input Cell:Blue Text Design Point:Outfall Design Storm:WQCV Approved Elevation Required Volume:40946 ft3 4931.99 4932.13 Design Storm:10-year Required Volume:0 ft3 N/A N/A Design Storm:100-year Required Volume:0 ft3 N/A N/A Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4928.60 0 0.0 0 0 0 0 0.00 4929.00 863 0.4 173 173 115 115 0.00 4930.00 8786 1.0 4825 4997 4135 4250 0.10 4931.00 19755 1.0 14271 19268 13905 18155 0.42 4932.00 26567 1.0 23161 42429 23077 41232 0.95 Extended Detention Basin (EDB) | G, H, Fut-G, Fut-H and Fut-TL2 Basins AS-BUILT Stage-Storage Calculations Required Volume Water Surface Elevation Average End Area Method:Conic Volume Method: WQCV 4929 4930 4931 4932 4933 0 5000 10000 15000 20000 25000 30000 35000 40000 45000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Extended Detention Basin Tributary area includes the G and H developed basins plus the Fut-G, Fut-H basins and Fut-TL2 (future east half of Timberline Road) Project:East Ridge Second Filing Project Location:Fort Collins, Colorado Date: 12/19/2017 Calculations By:H. Feissner Pond Description:SF for I and Fut-TL3 Basins User Input Cell:Blue Text Design Point:Outfall Design Storm:WQCV Approved Elevation Required Volume:14173 ft3 4931.82 4931.87 Design Storm:10-year Required Volume:0 ft3 N/A N/A Design Storm:100-year Required Volume:0 ft3 N/A N/A Contour Elevation Contour Area Depth Incremental Volume Cummulative Volume Incremental Volume Cummulative Volume Cummulative Volume ft ft2 ft ft3 ft3 ft3 ft3 ac-ft 4930.50 8854 0.0 0 0 0 0 0.00 4931.00 10355 0.5 4802 4802 4797 4797 0.11 4932.00 12649 1.0 11502 16304 11483 16280 0.37 Sand Filter (SF) | I and Fut-TL3 Basins AS-BUILT Stage-Storage Calculations Required Volume Water Surface Elevation Average End Area Method:Conic Volume Method: WQCV 4929 4930 4931 4932 4933 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 Contour Elevation, ft Cummulative Volume, ft3 Stage - Storage | Sand Filter (SF) Tributary area includes the I developed basins plus the Fut-I basins and Fut-TL3 (future east half of Timberline Road) 12/15 Page 2 B.Water Quality and Quantity Detention Basin Grading: Attached is as-built verification that there is a minimum 2% positive fall into the concrete trickle pans or flow-line(s) from all areas in the bottom of the detention pond. If there is a “soft pan” in the flow-line, all areas still must meet the minimum 2% grade requirement. 1.Low Flow: Choose one of the following detention basin low flow options as applicable: a. Turf swale for low flow path in detention basin. There is a minimum 2% grade in the flow-line(s) of the detention basin. The flattest as-built grade is . b.Concrete pan for low flow in detention basin. There is a concrete pan installed that meets the grades as shown on the approved construction plans. (Show as-built spot elevations.) c.Soft pan for low flow in detention basin. •Verify and document the soft pan material gradation, trench width and depth - to be verified during construction by engineer. Picture documentation is preferred or engineer’s statement of visual inspection and compliance. (Choose one below.) o There is a soft pan with an underdrain installed that meets the design on the approved construction plans. (Show the underdrain grades, bedding material, geotextile, spot elevations, bends, cleanouts, etc.) o There is soft pan installed without an underdrain but there is a type A or B soil. The soil type must be documented by supplying verification from a registered professional geotechnical engineer. NOTE: Spot elevations are to be within 0.2 ft. +/-. 2. Side Slopes: The as-built side slopes of the detention basin have been calculated and are shown. Indicate the side slope with an arrow and a numerical value (e.g., 6.25:1). The maximum slope allowed is 4:1. Small areas of 3:1 may be acceptable, but slopes steeper than 3:1 must be stabilized or re- graded. Provide documentation if a variance was granted for steeper slopes during the design process. 3.Spillway Certification: The following items must be field verified: a.The location of the spillway is indicated on the as-built plan. b.The width of the spillway is indicated on the as-built plan. c.The elevation(s) of the spillway is shown on the as-built plan. d.A concrete ribbon defines the location and grade of the spillway. e.There is downstream scour protection in the spillway as per the construction plans. Indicate type: (riprap size “D50” gradation and bedding type, geotextile, buried riprap with inches of bury, etc.). f.There are no obstructions in the spillway, such as trees, bushes, sidewalks, landscape features, rocks, etc. 12/15 Page 3 4.Outlet Structure Certification a.The orifice plate for the approved release rate is installed with the correct size and location of the orifice. b.The orifice plate for the water quality outlet is installed with the correct hole size, number of rows and columns of holes. c.The bottom hole on both the water quality and quantity outlets are at the bottom of the plate so no water ponds in front of the plate. d.The well screen is the correct material and is installed as shown on the construction plans. e.100-year overflow grate elevation is . (Elev. A on detail D-46) f.The top elevation of the water quality capture volume is . (Elev. B on detail D-46) g.Overflow grate is made of the correct material, has the correct bar spacing, is hinged at the top and bolted at the bottom. h.The bottom of the outlet box has no obstructions or misalignments that will cause it to retain runoff water and is sloped at 2% towards outlet. II.Channels/Swales - FCSCM Vol.1, Ch.7, Sect.3&4 A. Capacity: The as-built capacity of all the major channels and swales has been verified. They meet or exceed capacity requirements shown in the approved drainage study for this project. 1.All swales are located within the drainage easements as shown on the construction plans. 2.Longitudinal slopes and side-slopes (cross-sections) have been verified. Design criteria requires longitudinal slopes of 2% min. (on vegetated swales) and side-slopes no steeper than 4:1. If these criteria are not met, the certification engineer will write a justification and propose mitigation for each instance or have the issues corrected. If variances to these criteria have previously been approved and are shown on the construction plans, no justification is needed. 3.As-built spot elevations on channels/swales are shown that correspond to spot elevations shown on the approved construction plans. 4.All permanent erosion control measures are installed as shown on the approved construction plans (e.g., drop structures, riprap, TRMs, etc.). (Include pictures and verification of the materials used as part of this verification.) 5.All pans, curbs, storm pipes or other appurtenances appropriately tie into each other in the system. (Pictures at tie-in points suggested.) 6.The minimum freeboard is provided for all channels and swales as shown on the approved construction plans or as identified in the approved drainage study. (Show the freeboard provided on the cross-sections as on the construction plan set or attached as separate documentation.) 7.The low flow portion of all channels or swales is clear of obstructions. (No landscaping, trees, shrubs, sod, etc. infringe on the low flow portion of channels or swales.) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 06.30.2016 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 06.30.16 TOPSOIL & LANDSCAPE TREATMENT 5:1 SLOPE UNDERDRAINS SLOPE TO DRAIN TO DAYLIGHT POINT AT 0.50% MIN. CITY OF FORT COLLINS BIORETENTION SAND MEDIA LANDSCAPING WITH NON-FLOATING MULCH WQCV DEPTH: 2.96' 6-INCH LAYER PEA GRAVEL DIAPHRAGM DESIGN VOLUME: 0.75 ac-ft WATER SURFACE: 4933.96 6" (MIN.) TO 18" LAYER OF CDOT CLASS C FILTER MATERIAL (MUST BE DEEP ENOUGH TO ALLOW UNDERDRAIN TO BE PLACED WITH POSITIVE SLOPE TO DAYLIGHT POINT) SAND FILTER INFLOW SPILLWAY OUTLET WITH TRASH RACK EMBANKMENT 1 1 1 OUTFLOW REFER TO DT09 FOR RIP-RAP REQUIREMENTS AT INFLOW POINT(S) 4:1 SIDESLOPES WITH NO AREAS GREATER THAN 3:1. WHEN USING WALLS, THE DESIGN SHOULD ALLOW FOR REMOVAL AND REPLACEMENT OF THE FILTER LAYER WITHOUT JEOPARDIZING THE INTEGRITY OF THE WALL. CLEAN OUT (TYP) 6" SLOTTED PIPE AT 20' O.C. SEE TABLE SF-2. PROVIDE MAINTENANCE ACCESS TO FILTER FLAT AREA OF SAND FILTER WQCV RIPRAP FILL VOIDS WITH FILTER MATERIAL FILTER MATERIAL SEE TABLE SF-1 6" MIN. UNDERDRAIN MEETING TABLE SF-2 SLOPE AT 0.5% MIN. CLEAN OUT WITH (2) 45º BENDS AND WATERTIGHT CAP ORIFICE PLATE FOR 12 HOUR DRAIN OF WQCV NOTE: THIS DETAIL SHOWS A PARTIAL INFILTRATION SECTION. FOR FULL INFILTRATION ELIMINATE UNDERDRAIN AND PROVIDE 1'-6" OF FILTER MATERIAL. FOR NO INFILTRATION PROVIDE IMPERMEABLE MEMBRANE SECURED TO CAST-IN-PLACE CONCRETE WALL. *SEE DETAILS SF-2 AND SF-3. PROFILE NTS SURFACE INFLOW INFLOW PIPE DIAMETER D 1'-11" MIN. 11 MIDPOINT BETWEEN UNDERDRAINS 1 SLOPE (STRAIGHT GRADE) SUBGRADE (2-10%) TO UNDERDRAIN TO REDUCE SATURATED SOIL CONDITIONS BETWEEN STORM EVENTS (OPTIONAL) 1.50' 0.50' 0.50' TOPSOIL & LANDSCAPE TREATMENT 5:1 SLOPE UNDERDRAINS SLOPE TO DRAIN TO DAYLIGHT POINT AT 0.50% MIN. CITY OF FORT COLLINS BIORETENTION SAND MEDIA LANDSCAPING WITH NON-FLOATING MULCH WQCV DEPTH: 1.36' 6-INCH LAYER PEA GRAVEL DIAPHRAGM DESIGN VOLUME: 0.33 ac-ft WATER SURFACE: 4930.36 6" (MIN.) TO 18" LAYER OF CDOT CLASS C FILTER MATERIAL (MUST BE DEEP ENOUGH TO ALLOW UNDERDRAIN TO BE PLACED WITH POSITIVE SLOPE TO DAYLIGHT POINT) SAND FILTER 1.50' 0.50' 0.50' 4928.50 4932.13 N/A 4932.13 3.63 12.50 4.00 1.00 1-5/16 10 1CC A A B B SECTION C-C SECTION A-A SECTION B-B WELL SCREEN FLOW CONTROL PLATE PLAN GENERAL NOTES A A ABBREVIATIONS LEGEND 4928.61 4931.78 N/A 4931.78 3.17 12.50 4.00 1.00 1-1/8 9 1 BIOSWALE | TRAPEZOIDAL SECTION EDB OUTLET STRUCTURE SAND FILTER PLAN, PROFILE AND SECTION FIGURE SF-1 1 3 2 5 Minimum 8" Thick Layer of CDOT No. 4 Aggregate Minimum 4" Perforated PVC Pipe (Optional Depending on Underlying Soil Conditions) 12" Ponding Depth Minimum 12" Thick Layer of Bioretention Sand Media (see Bioretention Sand Media Specification from City of Fort Collins) Minimum 6" Thick Layer of Pea Gravel Diaphragm Water Surface Minimum CDOT No. 4 Aggregate Above and Below PVC Pipe Undisturbed Soil 2" SECTION A-A SECTION B-B WELL SCREEN FLOW CONTROL PLATE GENERAL NOTES A A ABBREVIATIONS LEGEND EDB OUTLET STRUCTURE4C AND D BASINS (NOTE 3 ON DR01)G AND H BASINS (NOTE 4 ON DR01) 2" Pipe Size Slot Length Maximum Slot Width Slot Centers Open Area (per foot) 4"1-1/16"0.032"0.413"1.90 in2 6"1-3/8"0.032"0.516"1.98 in2 UDFCD TABLE SF-2 CC A A B B SECTION C-C PLAN *DETAILS SF-2 AND SF-3 ONLY APPLY TO NO INFILTRATION SECTION. CDOT Class B Filter Material CDOT Class C Filter Material Sieve Size Mass Percent Passsing Square Mesh Sieves 37.5mm (1.5")100 19.0mm (0.75")100 4.75mm (No. 4)20 - 60 60 - 100 1.18um (No. 16)30-Oct 300um (No. 50)0 - 10 0 - 30 150um (No. 100)0 - 10 75um (No. 200)0 -3 0 - 3 UDFCD TABLE SF-1 1 07.07.17 Pond Revisions JEP 4928.56 4931.80 4931.60 to 4931.83 ±1 5/16" 10 ±3.04 1 9 4928.60 4932.03 4932.00 to 4932.10 ±1 5/16" ±3.40 1 AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 10 6' 4 11.50' 4 1 1' 4' MIN 2-yearQ =94.22cfs 100-yearQ =311.50cfs 2.51' 1.5' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 06.30.2016 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 06.30.16 SAND FILTER2 EXTENDED DETENTION BASIN (EDB)3 EXTENDED DETENTION BASIN (EDB)4 SAND FILTER5 1 07.07.17 Pond Revisions JEP AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 12/15 Page 4 III.Storm Pipes (aka storm drains) - FCSCM Vol.1, Ch.6, Sec. 4 A. Storm Drain Pipe Capacity: The as-built capacity of all pipes installed on this project has been verified and meets or exceeds the capacity requirements shown in the approved drainage study for this project. 1.All storm drain pipe sizes and materials have been verified and are in conformance with the approved construction plans. (Indicate on the plan and profile sheets that they have been verified.) Material and size substitutions must be approved prior to installation. If a pipe size or material was changed during construction, the certification engineer must attach the approval documents or supply them with this certification. Approval documents must include a calculation documenting the capacity equivalency (equal or greater) of the substituted size. 2.The longitudinal slope of the pipe is as shown on the approved construction plans. The acceptable minimum slope is 0.4%. All slopes flatter than the designed slope on the construction plans must be justified with capacity calculations on an attached sheet. 3.The as-built invert elevations have been verified and are shown on the plan and profile sheets of the approved construction plans. B.Storm Drain Pipe Installation Requirements: All pipes are installed in accordance with the approved construction plans. 1.The minimum cover requirements for all pipes have been met as shown on the approved construction plans. These will be called out in critical locations. 2.All encasements and clearances as specified on the approved construction plans have been met. 3.Any specific joint types or construction methods specified on the approved construction plans have been met. (List on a separate sheet and attach to this certification.) IV.Concrete Pans - FCSCM Vol.1, Ch.7, Sec.4.1.3.4 A. Construction/Installation: All concrete pans have been constructed in accordance with the approved construction plans. 1.The concrete pans are the correct size/width as shown on the approved construction plans. 2.The longitudinal slopes of the pans are as shown on the approved construction plans. The certification engineer must justify or mitigate longitudinal slopes less than the minimum of 0.4% unless a flatter slope was approved and is shown on the approved construction plans. Provide mitigation or justification by separate document. 3.The cross-section of the pan is as shown on the construction plans. (Specifically, the pan cross- section is “V” shaped and meets the side slope shown on the detail.) 4.The concrete pans are a minimum of 6 inches thick without reinforcement and a minimum of 4 inches thick with a minimum of 6X6-W14xW14 reinforcement per detail D20B and D20C. (Provide documentation of the reinforcement used if different than shown on the details or on the approved construction plans.) 5.The spot elevations shown on the concrete pan(s) have been verified and are shown on the as- built drawings. 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 12''SS 12''SS 12''SS 8''SS 8''SS 8''SS 8''SS 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W S 8''SS 10+0011+00 12+00 13+0014+0015+0016+0017+00 STORM DRAIN A6 SEE SHEET SD01 STORM DRAIN A4 SEE SHEET SD02 VICOT WAY CRUSADER STREET (A) ZEPPELIN WAY LOT 15 LOT 14 LOT 13 LOT 12 LOT 21 LOT 20 LOT 19 LOT 18 LOT 15 LOT 14 LOT 13 LOT 12 LOT 11 LOT 32 LOT 31 LOT 30 LOT 29 LOT 28 LOT 27 LOT 26 LOT 25 LOT 24 LOT 17 LOT 18 LOT 19 LOT 20 LOT 23 LOT 22 LOT 21 LOT 16 LOT 17 LOT 16 TRACT D TRACT E TRACT E TRACT E TRACT B BLOCK 2 BLOCK 3 BLOCK 3PRIVATE DRIVE TIGERCAT WAY SANITARY LINE 1-4 SEE SHEET SS06 SANITARY LINE 1-4.3 SEE SHEET SS08 STORM DRAIN A3 SEE SHEET SD02 SANITARY LINE 1-4 SEE SHEET SS06 CONTACT DESIGN ENGINEER PRIOR TO CONSTRUCTION TO CONFIRM SIZE OF PIPE 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0019+00 54''RCP 156.15 LF @ 0.45% STA=11+57.65 INLET A1 9' TRIPLE TYPE 16 COMBO INLET TBC=4941.19 INV IN (48" W)=4931.20 INV OUT (54" E)=4931.20 DEPTH=9.99 48''RCP 34.24 LF @ 0.40% STA=11+93.39 SDMH A2 8'Ø MH RIM=4941.60 INV IN (48" W)=4931.34 INV OUT (48" E)=4931.34 DEPTH=10.27 48''RCP 94.55 LF @ 0.40% STA=12+87.93 SDMH A3 8'Ø MH RIM=4942.07 INV IN (48" W)=4931.71 INV IN (18" S)=4933.71 INV OUT (48" E)=4931.71 DEPTH=10.36 48''RCP 163.04 LF @ 0.40% STA=40+26.87 (STORM A4) STA=14+50.98 STORM A SDMH A4 8'Ø MH RIM=4940.93 INV IN (48" W)=4932.37 INV IN (30" N)=4933.87 INV IN (30" S)=4933.87 INV OUT (48" E)=4932.37 DEPTH=8.57 48''RCP 110.97 LF @ 0.40% STA=15+61.95 SDMH A5 6'Ø MH RIM=4941.63 INV IN (42" W)=4933.31 INV OUT (48" E)=4932.81 DEPTH=8.82 42''RCP 165.94 LF @ 0.40% STA=50+00.00 (STORM A6) STA=17+27.88 STORM A SDMH A6 8'Ø FLAT TOP MH RIM=4941.18 INV IN (36" N)=4933.97 INV IN (36" S)=4934.47 INV OUT (42" E)=4933.97 DEPTH=7.20 PROPOSED GRADE EXISTING GRADE STA=12+97.93 INV=4928.11 8" SANITARY CROSSING 18" MIN. STA=17+36.38 INLET A7 15' CDOT TYPE R INLET TBC=4941.33 INV IN (36" N)=4934.01 INV OUT (36" S)=4934.01 DEPTH=7.32 STA=15+54.94 INV=4929.34 8" SANITARY CROSSING STA=15+42.94 TOP=4930.82 8" WATER CROSSING STA=13+07.93 TOP=4929.88 8" WATER CROSSING STA=10+57.64 TOP=4927.76 8" WATER CROSSING STA=10+00.00 FES A 54" FES INV IN (54" W)=4930.50 STA=10+47.58 INV=4927.71 8" SANITARY CROSSING CONCRETE ENCASE EACH SIDE 36'' RCP 8.50 LF @ 0.40% 18" MIN.18" MIN. HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL 100 yr HGL 1.78' CONCRETE CUT-OFF WALL CONCRETE CUT-OFF WALL 36'' RCP 31.89 LF @ 0.40% STA=17+68.28 FES A8 30" FES INV OUT (36" S)=4934.13 4925 4930 4935 4940 4945 4950 4955 4925 4930 4935 4940 4945 4950 4955 49+25 50+00 51+00 STA=50+28.50 INLET A6.1 3' SINGLE TYPE 16 COMBO INLET TBC=4941.33 INV IN (24" SE)=4935.59 INV OUT (36" N)=4934.59 DEPTH=6.74 36'' RCP 28.50 LF @ 0.40% STA=17+27.88 (STORM A) STA=50+00.00 STORM A6 SDMH A6 8'Ø FLAT TOP MH RIM=4941.18 INV IN (36" N)=4933.97 INV IN (36" S)=4934.47 INV OUT (42" E)=4933.97 DEPTH=7.20 PROPOSED GRADE EXISTING GRADE 18" MIN. STA=50+14.25 TOP=4932.70 8" WATER CROSSING 100 yr HGL STA=50+71.70 FES A6.2 24" FES INV OUT (24" NW)=4935.76 24'' RCP 42.96 LF @ 0.40% CONCRETE CUT-OFF WALL # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN A 10+00.00 17+68.28 50 5 SD01 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN A6 50+00.00 50+71.70 50 5 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4930.58 4931.29 4931.29 158.2 LF 36.3 LF 0.39% 95.0 LF @ 0.41% 4941.66 4931.43 4931.43 4942.04 4931.79 4933.40 4931.79 163.0 LF @ 0.29% 4941.17 4932.27 4933.80 4933.80 4932.27 106.79 LF @ 0.21% 4941.92 4932.99 4932.49 169.14 LF @ 0.41% 5.5 LF 6.91% 4934.11 4941.44 4933.78 4934.16 32.3 LF @ -0.15% 4934.34 4934.26 4933.68 RIM=4941.41 158.2 LF 36.3 LF 0.39% 95.0 LF @ 0.41% 163.0 LF @ 0.29%106.79 LF @ 0.21%169.14 LF @ 0.41% 5.5 LF 6.91% 32.3 LF @ 0.71% 4935.64 41.5 LF 2.67% 4941.44 4933.78 4934.26 4933.68 4934.53 4934.53 RIM=4941.40 25.5 LF 1.06% 41.5 LF 2.67% 25.5 LF 1.06% 4931.16 AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 39+00 40+00 41+00 42+00 30'' RCP 25.37 LF @ 0.40% 30'' RCP 10.13 LF @ 0.41% STA=40+37.00 INLET A4.1 15' CDOT TYPE R INLET TBC=4941.04 INV IN (18" NE)=4934.91 INV OUT (30" S)=4933.91 DEPTH=7.13 STA=40+00.00 INLET A4A 9' TRIPLE TYPE 16 COMBO INLET TBC=4941.04 INV OUT (30" N)=4933.97 DEPTH=7.07 STA=14+50.98 (STORM A) STA=50+01.17 STORM A6 SDMH A4 8'Ø MH RIM=4940.93 INV IN (48" W)=4932.37 INV IN (30" N)=4933.87 INV IN (30" S)=4933.87 INV OUT (48" E)=4932.37 DEPTH=8.57 PROPOSED GRADE 18'' RCP 40.33 LF @ 0.38% STA=40+80.29 INLET A4.2 9' TRIPLE TYPE 16 COMBO INLET TBC=4941.66 INV OUT (18" SW)=4935.06 DEPTH=6.60 STA=40+07.69 TOP=4932.15 8" WATER CROSSING STA=40+17.69 INV=4928.69 8" SANITARY CROSSING 100 yr HGL 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 19+50 20+00 21+00 21+50 STA=20+94.98 INLET A3-2 6' DOUBLE TYPE 16 COMBO INLET TBC=4941.73 INV OUT (18" E)=4934.09 DEPTH=7.63 18'' RCP 28.50 LF @ 0.40% 18'' RCP 66.42 LF @ 0.40% STA=30+00.00 (STORM A3-1) STA=20+66.48 STORM A3 SDMH A3-1 5'Ø FLAT TOP MH RIM=4941.58 INV IN (18" E)=4933.98 INV IN (18" W)=4933.98 INV OUT (18" N)=4933.98 DEPTH=7.60 STA=12+89.66 (STORM A) STA=20+00.09 STORM A3 SDMH A3 8'Ø MH RIM=4942.07 INV IN (48" W)=4931.71 INV IN (18" S)=4933.71 INV OUT (48" E)=4931.71 DEPTH=10.36 STA=20+76.48 INV=4927.62 12" SANITARY CROSSING PROPOSED GRADE EXISTING GRADE STA=20+86.48 TOP OF CASING=4932.35 8" WATER CROSSING 100 yr HGL 18" MIN. 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 29+50 30+00 31+00 STA=20+66.48 (STORM A3) STA=30+00.00 STORM A3-1 SDMH A3-1 5'Ø FLAT TOP MH RIM=4941.58 INV IN (18" E)=4933.98 INV IN (18" W)=4933.98 INV OUT (18" N)=4933.98 DEPTH=7.60 18'' RCP 7.00 LF @ 0.40% STA=30+08.50 INLET A3-1A 10' CDOT TYPE R INLET TBC=4941.73 INV OUT (18" W)=4934.01 DEPTH=7.72 PROPOSED GRADE EXISTING GRADE # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN A4 40+00.00 40+80.33 50 5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN A3 20+00.00 20+92.86 50 5STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN A3-1 30+00.00 30+10.60 50 5 SD02 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4931.79 4933.40 4931.79 4942.04 4941.78 4933.93 4933.98 4933.82 4934.22 26.8 LF 0.89% 64.16 LF 0.65% 64.16 LF 26.8 LF 0.89% 4932.27 4933.80 4933.80 4941.17 4932.27 4935.06 4933.96 4933.94 38.4 LF @ 2.86% 11.8 LF @ 1.19% 24.1 LF @ 0.50% 4941.11 49433.92 4933.93 4933.98 4933.82 4941.87 4933.95 8.6 LF 0.23% 8.6 LF @ 0.23% 38.4 LF @ 2.86% 11.8 LF @ 1.19% 24.1 LF @ 0.50% 4941.87 4941.84 0.65% 4941.69 4941.16 AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 59+5060+0061+0062+0063+0064+0065+0066+0067+0068+00 18" MIN. 18" MIN. 18" MIN. STA=90+10.67 (STORM B6) STA=67+05.72 STORM B SDMH B6 8'Ø FLAT TOP MH RIM=4944.26 INV IN (60" NE)=4933.81 INV IN (24" SE)=4937.31 INV IN (36" NW)=4936.31 INV OUT (66" SW)=4933.81 DEPTH=10.96 66''RCP 34.07 LF @ 0.40% STA=66+71.65 SDMH B5 11'X10' BOX BASE MH RIM=4944.37 INV IN (66" NE)=4933.67 INV IN (36" W)=4933.67 INV OUT (66" SE)=4933.67 DEPTH=11.20 66''RCP 145.49 LF @ 0.40% STA=65+24.91 INLET B4 12' TYPE 16 COMBO INLET TBC=4944.68 INV IN (66" NW)=4933.09 INV OUT (66" SE)=4933.09 DEPTH=12.09 66''RCP 132.59 LF @ 0.40% STA=70+00.00 (STORM B3) STA=63+91.07 STORM B SDMH B3 8'Ø FLAT TOP MH RIM=4943.92 INV IN (66" NW)=4932.56 INV IN (24" NE)=4936.06 INV OUT (66" SE)=4932.56 DEPTH=11.86 66''RCP 121.83 LF @ 0.40% STA=62+67.74 INLET B2 9' TRIPLE TYPE 16 COMBO INLET TBC=4942.79 INV IN (66" NW)=4932.07 INV OUT (66" SE)=4932.07 DEPTH=10.72 66''RCP 118.81 LF @ 0.40% STA=61+47.43 SDMH B1 11'X10' BOX BASE MH RIM=4941.26 INV IN (66" NW)=4931.60 INV OUT (66" S)=4931.60 DEPTH=10.17 66''RCP 147.43 LF @ 0.40% STA=60+00.00 OUTLET B END OF PIPE AT HEADWALL INV IN (66" N)=4931.01 60''RCP 106.81 LF @ 0.50% STA=61+67.74 TOP=4929.57 8" WATER CROSSING STA=64+16.28 TOP=4930.56 8" WATER CROSSING STA=66+51.52 TOP=4931.49 8" WATER CROSSING HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL EXISTING GRADE PROPOSED GRADE 100 yr HGL 18" MIN. STA=67+77.03 TOP=4932.10 8" WATER CROSSING KEYMAP STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN B 60+00.00 68+00.00 50 5 MATCH LINE SEE SHEET: STA: SD04 68+00.00 SD03 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4932.40 4935.90 4932.38 4931.91 4931.82 4940.20 4931.40 4931.35 4931.08 121.08 LF @0.35% 149.52 0.18% 121.70 LF @0.39% TOC=4943.56 4933.01 4932.90 132.3 LF @ 0.38%145.0 LF @0.40% 4944.42 4933.74 4933.87 4933.59 4944.42 4933.98 4937.29 4936.02 4933.90 41.3 LF 102.8 LF 132.3145.0 41.3 LF 102.8 LF 0.41% 0.39% 4943.82 4942.70 0.38% 0.39% 0.41% AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''W 8''W 8''W 8''SS 8''SS 8''SS 8''W 8''SS 12''W 12''W 12''W 12''W 12''W 12''W 12''W 8''W S 8''W 8''W 8''W 8''W 8''W 68+00 69+00 70+00 71+00 72+00 73+00 SYKES DRIVE LOT4 LOT 3 LOT 2 LOT 1 LOT 12 LOT 11 TRACT N BLOCK 1 SANITARY LINE 1-11.5 SEE SHEET SS19 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 68+0069+0070+0071+0072+0073+0074+0074+50 STA=73+79.67 FES B12 36" FES INV OUT (36" S)=4939.19 36''RCP 71.59 LF @ 0.50% STA=73+08.09 SDMH B11 6'Ø FLAT TOP MH RIM=4945.81 INV IN (36" N)=4938.83 INV OUT (36" E)=4938.83 DEPTH=6.98 36''RCP 176.52 LF @ 0.50% STA=71+31.56 SDMH B10 6'Ø FLAT TOP MH RIM=4944.77 INV IN (36" W)=4937.94 INV OUT (36" E)=4937.94 DEPTH=6.83 36''RCP 114.88 LF @ 0.50% STA=90+13.45 (STORM B9) STA=70+16.69 STORM B SDMH B9 8'Ø FLAT TOP MH RIM=4944.17 INV IN (36" W)=4937.36 INV IN (42" N)=4936.20 INV IN (24" S)=4936.20 INV OUT (54" E)=4935.86 DEPTH=8.81 54''RCP 59.15 LF @ 0.50% STA=100+00.00 (STORM B8) STA=69+57.54 STORM B SDMH B8 8'Ø FLAT TOP MH RIM=4944.45 INV IN (54" W)=4935.57 INV IN (42" N)=4936.57 INV OUT (60" S)=4935.07 DEPTH=9.88 60''RCP 145.01 LF @ 0.50% 18" MIN. 60'' RCP 106.81 LF @ 0.50% STA=73+35.18 TOP=4937.13 12" WATER CROSSING STA=72+43.68 INV=4934.75 8" SANITARY CROSSING STA=68+12.53 SDMH B7 8'Ø FLAT TOP MH RIM=4944.85 INV IN (60" N)=4934.34 INV OUT (60" SW)=4934.34 DEPTH=11.01 HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL EXISTING GRADEPROPOSED GRADE 100 yr HGL 18" MIN. STA=72+58.68 TOP=4936.75 8" WATER CROSSING CONCRETE CUT-OFF WALL 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 69+00 70+00 71+00 72+00 24'' RCP 24.90 LF @ 1.00% STA=70+26.65 INLET B3.1 9' TRIPLE TYPE 16 COMBO INLET TBC=4944.10 INV IN (24" NW)=4936.51 INV OUT (24" SW)=4936.31 DEPTH=7.79 24'' RCP 34.08 LF @ 1.00% STA=70+63.74 INLET B3.2 15' TYPE 16 COMBO INLET TBC=4944.10 INV OUT (24" SE)=4936.85 DEPTH=7.25 STA=63+91.07 (STORM B) STA=70+00.00 STORM B3 SDMH B3 8'Ø FLAT TOP MH RIM=4943.92 INV IN (66" NW)=4932.56 INV IN (24" NE)=4936.06 INV OUT (66" SE)=4932.56 DEPTH=11.86 EXISTING GRADE PROPOSED GRADE 100 yr HGL STA=70+55.24 TOP=4935.03 8" WATER CROSSING18" MIN. KEYMAP STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN B 68+00.00 73+83.95 50 5 MATCH LINE SEE SHEET: STA: SD03 68+00.00 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN B3 70+00.00 70+63.74 50 5 SD04 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4932.38 4935.90 4932.38 4936.25 4936.15 4936.56 4939.14 4945.86 4938.81 4938.76 4944.77 4944.36 4944.66 4944.56 4934.46 4934.26 60.39 LF 146.93 LF @0.44% 4937.25 4936.12 4939.19 4935.69 4935.42 4936.56 4935.14 75.8LF@0.43% 75.8 LF @ 0.44% 177.73LF@0.49% 177.73 LF@ 0.49%117.46 LF @ 0.61% 4937.89 4937.79 0.45 % 60.39 LF 0.45 % 117.45LF@1.18% 33.05 LF 22.55 1.11% 0.94% 4943.82 4943.96 4944.07 AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 89+00 90+00 91+00 91+50 36'' RCP 9.17 LF @ 1.00% STA=90+00.00 INLET B6.1 5' CDOT TYPE R INLET TBC=4944.35 INV OUT (36" SE)=4936.40 DEPTH=7.95 24'' RCP 24.83 LF @ 1.00% STA=67+05.72 (STORM B) STA=90+10.67 STORM B6 SDMH B6 8'Ø FLAT TOP MH RIM=4944.26 INV IN (60" NE)=4933.81 INV IN (24" SE)=4937.31 INV IN (36" NW)=4936.31 INV OUT (66" SW)=4933.81 DEPTH=10.96 STA=90+37.00 INLET B6A 12' QUAD TYPE 16 COMBO INLET TBC=4944.35 INV OUT (24" NW)=4937.56 DEPTH=6.79 18" MIN. STA=90+30.43 TOP=4935.76 8" WATER CROSSING STA=90+20.43 INV=4934.34 8" SANITARY CROSSING EXISTING GRADE PROPOSED GRADE 100 yr HGL 4925 4930 4935 4940 4945 4950 4955 4925 4930 4935 4940 4945 4950 4955 89+0090+0091+0091+50 42'' RCP 39.23 LF @ 0.50% 24'' RCP 10.45 LF @ 1.00% STA=70+16.69 (STORM B) STA=90+13.45 STORM B9 SDMH B9 8'Ø FLAT TOP MH RIM=4944.17 INV IN (36" W)=4937.36 INV IN (42" N)=4936.20 INV IN (24" S)=4936.20 INV OUT (54" E)=4935.86 DEPTH=8.81 18" MIN.STA=90+41.71 TOP=4934.47 12" WATER CROSSING STA=90+23.54 INV=4933.28 8" SANITARY CROSSING EXISTING GRADE PROPOSED GRADE 100 yr HGL STA=90+01.50 INLET B9A 10' CDOT TYPE R INLET TBC=4944.16 INV OUT (24" N)=4936.31 DEPTH=7.85 STA=90+52.68 INLET B9.1 15' TYPE 16 COMBO INLET TBC=4944.21 INV OUT (42" S)=4936.40 DEPTH=7.81 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 109+50 110+00 111+00 111+50 CONCRETE CUT-OFF WALL 36''RCP 66.79 LF @ 0.40% STA=??? FES B5.1 24" FES INV OUT (36" E)=4933.94 STA=66+71.69 (STORM B) STA=110+72.29 STORM B5 SDMH B5 11'X10' BOX BASE MH RIM=4944.37 INV IN (66" NE)=4933.67 INV IN (36" W)=4933.67 INV OUT (66" SE)=4933.67 DEPTH=11.20 EXISTING GRADE PROPOSED GRADE # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN B6 90+00.00 90+78.12 50 5 STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN B9 90+01.50 90+52.83 50 5 SD05 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING ( IN FEET ) 1 inch = ft. 050 50 50 100 150 STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN B5 110+00.00 110+72.29 50 5 26.74 LF 4937.71 RIM=4943.31 4933.90 4936.02 4937.29 4933.98 26.74LF 4944.22 RIM=4942.78 4936.48 74.5 LF 4934.08 4944.42 4933.74 4933.87 49333.59 74.5 LF 0.28% 14.04 LF@ 0.78%35.94 LF@ 1.31% 4936.16 4935.69 4939.19 4936.12 4937.25 4944.36 4942.27 4936.59 14.04 LF @0.78% 35.94 LF @ 1.31% 0.28% 1.57% 8.12LF 5.67% @ 1.57% 4944.25 AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 109+50110+00111+00112+00113+00114+00115+00116+00117+00118+00119+00120+00 STA=110+00.00 OUTLET C END OF PIPE AT HEADWALL INV IN (60" N)=4931.01 60''RCP 211.87 LF @ 0.40% STA=112+11.87 SDMH C1 8'Ø FLAT TOP MH RIM=4941.75 INV IN (60" NE)=4931.86 INV OUT (60" S)=4931.86 DEPTH=9.90 60''RCP 262.28 LF @ 0.40% STA=114+75.66 INLET C2 10' CDOT TYPE R INLET TBC=4943.31 INV IN (54" NE)=4932.90 INV OUT (60" SW)=4932.90 DEPTH=10.41 54'' RCP 10.60 LF @ 0.40% STA=120+00.00 (STORM C3) STA=114+87.75 STORM C SDMH C3 8'Ø MH RIM=4943.26 INV IN (54" NW)=4932.95 INV IN (18" NE)=4935.95 INV OUT (54" SW)=4932.95 DEPTH=10.32 54''RCP 261.71 LF @ 0.40% STA=117+49.47 SDMH C4 8'Ø MH RIM=4944.77 INV IN (54" NE)=4933.99 INV OUT (54" SE)=4933.99 DEPTH=10.78 54''RCP 124.92 LF @ 0.40% STA=130+23.50 (STORM C5) STA=118+74.39 STORM C SDMH C5 7'Ø FLAT TOP MH RIM=4943.87 INV IN (48" NE)=4934.99 INV IN (18" NW)=4937.49 INV IN (18" SE)=4937.49 INV OUT (54" SW)=4934.49 DEPTH=9.37 48''RCP 141.09 LF @ 0.50% PROPOSED GRADE EXISTING GRADE 18" MIN. 18" MIN. STA=114+99.24 INV=4929.87 8" SANITARY CROSSING STA=115+09.00 TOP=4931.01 8" WATER CROSSING STA=117+39.22 INV=4931.13 8" SANITARY CROSSING STA=117+60.57 INV=4931.12 8" SANITARY CROSSING STA=117+72.06 TOP=4932.06 8" WATER CROSSING 100 yr HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL 4930.49 4931.66 4931.72 49341.72 4932.72 4932.74 210.17 0.56% 259.94 0.38% 4932.80 (N) 4943.36 4935.76 (S) 4943.32 4932.80 (SW) # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN C 110+00.00 120+00.00 50 5 MATCH LINE SEE SHEET: STA: SD08 120+00.00 SD07 LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R ( IN FEET ) 1 inch = ft. 050 50 50 100 150 268.19 LF @ 0.40% 4944.75 4933.86 4933.86 AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 119+00 120+00 121+00 121+50 STA=114+87.75 (STORM C) STA=120+00.00 STORM C3 SDMH C3 8'Ø MH RIM=4943.26 INV IN (54" NW)=4932.95 INV IN (18" NE)=4935.95 INV OUT (54" SW)=4932.95 DEPTH=10.32 STA=120+39.24 INLET C3.1 12' QUAD TYPE 16 COMBO INLET RIM=4943.31 INV OUT (18" SW)=4936.70 DEPTH=6.61 18'' RCP 37.74 LF @ 2.00% PROPOSED GRADE EXISTING GRADE 18" MIN. STA=120+13.46 INV=4929.56 8" SANITARY CROSSING STA=120+25.78 TOP=4934.75 8" WATER CROSSING 100 yr HGL 4932.80 (N) 4943.36 4935.76 (S) 4932.80 (SW) 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 129+00 130+00 131+00 131+50 PROPOSED GRADE EXISTING GRADE STA=130+31.00 INLET C5A 10' CDOT TYPE R INLET TBC=4944.07 INV OUT (18" SE)=4937.55 DEPTH=6.51 18'' RCP 5.99 LF @ 1.00% 18'' RCP 22.00 LF @ 1.00% STA=130+00.00 INLET C5.1 15' TYPE 16 COMBO INLET TBC=4944.06 INV OUT (18" NW)=4937.71 DEPTH=6.35 STA=118+74.39 (STORM C) STA=130+23.50 STORM C5 SDMH C5 7'Ø FLAT TOP MH RIM=4943.87 INV IN (48" NE)=4934.99 INV IN (18" NW)=4937.49 INV IN (18" SE)=4937.49 INV OUT (54" SW)=4934.49 DEPTH=9.37 100 yr HGL 4925 4930 4935 4940 4945 4950 4955 4925 4930 4935 4940 4945 4950 4955 139+00 140+00 141+00 142+00 18" MIN. 30''RCP 56.25 LF @ 0.50% STA=140+59.82 INLET C6.1 6' DOUBLE TYPE 16 COMBO INLET TBC=4946.07 INV IN (24" NE)=4937.98 INV OUT (30" NW)=4937.48 DEPTH=8.59 24'' RCP 31.94 LF @ 0.50% STA=140+91.75 INLET C6.2 15' TYPE 16 COMBO INLET TBC=4945.99 INV OUT (24" SW)=4938.14 DEPTH=7.86 STA=120+15.50 (STORM C) STA=140+00.00 STORM C6 SDMH C6 8'Ø MH RIM=4945.69 INV IN (48" NE)=4935.70 INV IN (30" SE)=4937.20 INV OUT (48" SW)=4935.70 DEPTH=9.99 PROPOSED GRADE EXISTING GRADE STA=140+81.08 TOP=4936.34 8" WATER CROSSING STA=140+67.14 INV=4931.83 8" SANITARY CROSSING HGL 100 yr HGL # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN C3 120+00.00 120+39.24 50 5 STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN C5 130+00.00 130+31.00 50 5 STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN C6 140+00.00 140+91.75 50 5 SD09 LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4936.53 4943.43 37.10 LF 2.08% 37.10 LF 2.08% AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 189+00190+00191+00192+00193+00194+00195+00196+00197+00198+00199+00200+00 18" MIN. 18" MIN. STA=190+00.00 FES D 66" FES INV IN (66" N)=4930.99 66''RCP 189.94 LF @ 0.40% STA=191+89.94 SDMH D1 8'Ø FLAT TOP MH RIM=4940.96 INV IN (66" NE)=4931.75 INV OUT (66" S)=4931.75 DEPTH=9.21 66''RCP 100.22 LF @ 0.40% STA=200+00.00 (STORM D2) STA=192+90.16 STORM D SDMH D2 8'Ø FLAT TOP MH RIM=4941.36 INV IN (66" N)=4932.15 INV IN (30" E)=4932.15 INV OUT (66" SW)=4932.15 DEPTH=9.21 66''RCP 119.45 LF @ 0.40% STA=194+09.62 SDMH D3 8'Ø FLAT TOP MH RIM=4941.84 INV IN (66" NE)=4932.63 INV OUT (66" S)=4932.63 DEPTH=9.21 66''RCP 137.51 LF @ 0.40% STA=210+00.00 (STORM D4) STA=195+47.13 STORM D SDMH D4 11'X10' BOX BASE MH RIM=4942.24 INV IN (60" N)=4933.18 INV IN (36" W)=4934.68 INV OUT (66" SW)=4933.18 DEPTH=9.06 60''RCP 148.66 LF @ 0.44% STA=196+97.29 INLET D5 12' QUAD TYPE 16 COMBO INLET TBC=4944.85 INV IN (60" N)=4934.04 INV OUT (60" S)=4933.84 DEPTH=11.01 60''RCP 123.09 LF @ 0.44% STA=198+21.88 INLET D6 10' CDOT TYPE R INLET TBC=4945.64 INV OUT (60" S)=4934.58 INV OUT (60" S)=4934.79 DEPTH=10.94 60'' RCP 7.12 LF @ 0.44% STA=230+00.00 (STORM D7) STA=198+29.00 STORM D SDMH D7 8'Ø FLAT TOP MH RIM=4945.43 INV IN (18" N)=4938.29 INV IN (60" E)=4934.79 INV OUT (60" S)=4934.79 DEPTH=10.64 60''RCP 53.37 LF @ 0.40% STA=198+82.37 SDMH D8 8'Ø FLAT TOP MH RIM=4945.71 INV IN (60" N)=4935.00 INV OUT (60" W)=4935.00 DEPTH=10.71 60''RCP 241.97 LF @ 0.40% STA=195+80.56 TOP=4931.26 8" WATER CROSSING STA=199+01.31 TOP=4933.02 WATER CROSSING STA=198+92.63 INV=4931.40 SANITARY CROSSING STA=195+60.64 INV=4926.61 18" SANITARY CROSSING PROPOSED GRADE EXISTING GRADE HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL 100 yr HGL CONCRETE CUT-OFF WALL 4931.00 4931.66 4931.64 4940.43 4931.94 4932.03 4932.00 4940.87 4932.41 4932.59 4941.39 120.82 0.31%98.22 0.31%191.09 0.35% 138.67 LF 0.39% # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN D 190+00.00 200+00.00 50 5 MATCH LINE SEE SHEET: STA: SD12 200+00.00 SD11 SD12 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4942.28 4933.14 4934.46 4933.12 AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 18" MIN. 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 199+50 200+00 201+00 201+50 STA=192+90.16 (STORM D) STA=200+00.00 STORM D2 SDMH D2 8'Ø FLAT TOP MH RIM=4941.36 INV IN (66" N)=4932.15 INV IN (30" E)=4932.15 INV OUT (66" SW)=4932.15 DEPTH=9.21 30'' RCP 27.58 LF @ 0.50% 30'' RCP 28.92 LF @ 0.50% STA=200+61.00 INLET D2.2 15' TYPE 16 COMBO INLET TBC=4940.08 INV OUT (30" W)=4932.63 DEPTH=7.44 STA=200+29.08 INLET D2.1 12' QUAD TYPE 16 COMBO INLET TBC=4940.02 INV IN (30" E)=4932.49 INV OUT (30" W)=4932.29 DEPTH=7.73 PROPOSED GRADE EXISTING GRADE STA=200+45.50 INV=4925.99 18" SANITARY CROSSING STA=200+55.50 TOP=4930.82 8" WATER CROSSING 100 yr HGL 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 209+50210+00211+00212+00 18" MIN. PROPOSED GRADEEXISTING GRADE STA=195+47.13 (STORM D) STA=210+00.00 STORM D4 SDMH D4 11'X10' BOX BASE MH RIM=4942.24 INV IN (60" N)=4933.18 INV IN (36" W)=4934.68 INV OUT (66" SW)=4933.18 DEPTH=9.06 36''RCP 62.19 LF @ 0.42% 36'' RCP 39.97 LF @ 0.41% STA=211+02.16 INLET D4.2 15' CDOT TYPE R INLET TBC=4942.06 INV OUT (36" S)=4935.30 DEPTH=6.76 STA=210+62.19 SDMH D4.1 6'Ø FLAT TOP MH RIM=4941.94 INV IN (24" S)=4936.14 INV IN (36" N)=4935.14 INV OUT (36" E)=4934.94 DEPTH=7.00 STA=210+92.24 TOP=4933.43 8" WATER CROSSING STA=210+75.66 INV=4926.71 18" SANITARY CROSSING HGL 100 yr HGL 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 229+50 230+00 231+00 18" MIN. STA=230+24.96 INLET D7.1 12' QUAD TYPE 16 COMBO INLET TBC=4945.56 INV OUT (18" S)=4938.41 DEPTH=7.16 18'' RCP 23.46 LF @ 0.50% STA=198+29.01 (STORM D) STA=230+00.00 STORM D7 SDMH D7 8'Ø FLAT TOP MH RIM=4945.43 INV IN (18" N)=4938.29 INV IN (60" E)=4934.79 INV OUT (60" S)=4934.79 DEPTH=10.64 PROPOSED GRADE EXISTING GRADE STA=230+19.91 TOP=4936.68 8" WATER CROSSING STA=230+09.96 INV=4931.08 8" SANITARY CROSSING 100 yr HGL 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 219+50 220+00 221+00 STA=210+62.19 (STORM D4) STA=220+00.00 STORM D4.1 SDMH D4.1 6'Ø FLAT TOP MH RIM=4941.94 INV IN (24" S)=4936.14 INV IN (36" N)=4935.14 INV OUT (36" E)=4934.94 DEPTH=7.00 STA=220+11.24 INLET D4.1A 15' CDOT TYPE R INLET TBC=4942.05 INV OUT (24" N)=4936.20 DEPTH=5.85 24'' RCP 11.24 LF @ 0.50% PROPOSED GRADE EXISTING GRADE 100 yr HGL # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN D2 200+00.00 200+61.00 50 5 STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN D4 210+00.00 211+02.44 50 5 STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN D7 230+00.00 230+24.96 50 5 SD13 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN D4.1 220+00.00 220+11.24 50 5 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4936.24 4935.22 4935.90 4940.87 4932.00 4932.03 4931.94 4932.50 4932.22 4932.58 12.9 LF 2.64% 4942.02 4935.90 4934.97 4934.74 12.9 LF 2.64% 41.9 LF 0.60% 67.81 LF 0.41% 4934.97 4934.74 4942.02 4933.14 4934.46 4933.12 4942.28 4940.19 4940.19 27.59 LF 1.30% 27.60 LF 0.69% 27.60 LF 0.69% 27.59 LF 1.30% 4942.29 4942.12 41.90 LF 0.60% 67.81 LF 0.41% AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 239+50 240+00 241+00 242+00 243+00 244+00 245+00 246+00 247+00 248+00 249+00 PROPOSED GRADE EXISTING GRADE STA=241+80.69 INLET E1 6' DOUBLE TYPE 16 COMBO INLET SEE NOTE IN PLAN VIEW ABOVE TBC=4939.72 INV IN (60" E)=4929.70 INV OUT (60" W)=4929.70 DEPTH=10.02 60'' RCP 29.27 LF @ 0.40% STA=242+13.04 INLET E2 9' TRIPLE TYPE 16 COMBO INLET TBC=4940.12 INV IN (60" E)=4929.82 INV OUT (60" W)=4929.82 DEPTH=10.30 60''RCP 445.60 LF @ 0.40% STA=240+00.00 (STORM E3) STA=246+60.14 STORM E SDMH E3 8'X8' BOX BASE MH SEE NOTE IN PLAN VIEW ABOVE RIM=4939.55 INV IN (60" N)=4931.60 INV IN (30" E)=4931.60 INV OUT (60" W)=4931.60 DEPTH=8.45 STA=248+12.56 INLET E5 12' QUAD TYPE 16 COMBO INLET TBC=4940.16 INV IN (54" N)=4932.19 INV OUT (54" S)=4932.19 DEPTH=7.97 STA=247+79.73 INLET E4 9' TRIPLE TYPE 16 COMBO INLET TBC=4940.16 INV IN (54" N)=4932.07 INV OUT (60" S)=4932.07 DEPTH=8.09 60''RCP 179.19 LF @ 0.40% 60''RCP 118.08 LF @ 0.40% 54'' RCP 29.83 LF @ 0.40% STA=240+00.00 FES E 60" FES INV IN (60" E)=4928.98 54''RCP 216.17 LF @ 0.48% 18" MIN. 18" MIN. STA=248+06.14 TOP=4930.15 8" WATER CROSSINGSTA=242+07.47 TOP=4927.74 8" WATER CROSSING STA=241+95.63 INV=4923.70 18" SANITARY CROSSING STA=247+96.14 INV=4927.79 8" SANITARY CROSSING HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL 100 yr HGL CONCRETE CUT-OFF WALL # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN E 240+00.00 249+00.00 50 5 MATCH LINE SEE SHEET: STA: SD15 249+00.00 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING ( IN FEET ) 1 inch = ft. 050 50 50 100 150 220.16 LF 0.40% 29.1 LF 0.48% 119.0 LF 0.42%448.30 LF 0.38% 28.2 LF 0.39% 180.40LF 0.40% 4928.83 4939.25 4929.56 4929.56 4940.12 4929.72 4929.67 4939.48 4931.43 4931.43 4931.43 4940.11 4931.93 4931.93 4940.29 4932.07 4932.07 448.30 LF 0.38% 119.0 LF 0.42% 29.1 LF 0.48% 180.40 LF 0.40% RIM 28.20 LF 0.39% AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 249+00250+00251+00252+00253+00254+00255+00256+00257+00258+00 18" MIN. STA=256+34.77 SDMH E14 8'Ø FLAT TOP MH RIM=4946.32 INV IN (36" N)=4938.49 INV OUT (36" W)=4938.29 DEPTH=8.03 STA=255+58.89 INLET E12 18' TYPE 16 COMBO INLET TBC=4945.89 INV IN (36" N)=4937.65 INV OUT (42" S)=4937.15 DEPTH=8.74 STA=254+56.89 SDMH E11 8'Ø FLAT TOP MH RIM=4944.87 INV IN (42" N)=4936.43 INV OUT (42" S)=4936.43 DEPTH=8.44 STA=254+26.15 INLET E10 12' QUAD TYPE 16 COMBO INLET TBC=4944.57 INV IN (42" N)=4936.22 INV OUT (42" S)=4936.22 DEPTH=8.36 STA=253+15.65 INLET E9 15' TYPE 16 COMBO INLET TBC=4942.96 INV IN (42" N)=4935.57 INV OUT (42" S)=4935.57 DEPTH=7.39 STA=252+83.73 INLET E8 12' QUAD TYPE 13 COMBO INLET TBC=4942.89 INV IN (42" N)=4935.41 INV OUT (54" S)=4934.41 DEPTH=8.48 STA=250+31.73 INLET E6 12' QUAD TYPE 16 COMBO INLET TBC=4942.03 INV IN (54" N)=4933.23 INV OUT (54" S)=4933.23 DEPTH=8.80 STA=250+64.56 INLET E7 12' QUAD TYPE 16 COMBO INLET TBC=4942.03 INV IN (54" N)=4933.37 INV OUT (54" S)=4933.37 DEPTH=8.66 54''RCP 216.17 LF @ 0.48% 54'' RCP 29.83 LF @ 0.48% 54''RCP 216.17 LF @ 0.48% 42'' RCP 28.92 LF @ 0.56% 42''RCP107.50 LF @ 0.60% 42''RCP29.24 LF@0.72% 42''RCP100.50 LF@0.72% 36'' RCP 14.00 LF @ 0.72% 36''RCP 60.38 LF @ 0.56% STA=250+00.00 (STORM E13) STA=255+74.39 STORM E SDMH E13 8'Ø FLAT TOP MH RIM=4945.94 INV IN (36" E)=4937.95 INV IN (24" N)=4938.95 INV OUT (36" S)=4937.75 DEPTH=8.19 36''RCP 271.96 LF @ 0.40% 18" MIN. 18" MIN. STA=250+58.15 TOP=4931.33 8" WATER CROSSING STA=253+10.15 TOP=4933.67 8" WATER CROSSING STA=256+54.77 TOP=4936.74 8" WATER CROSSING STA=253+00.15 INV=4929.74 8" SANITARY CROSSING STA=250+48.18 INV=4928.50 8" SANITARY CROSSING STA=256+44.77 INV=4931.67 8" SANITARY CROSSING HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL HGL 100 yr HGL EXISTING GRADE PROPOSED GRADE # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN E 249+00.00 258+00.00 50 5 MATCH LINE SEE SHEET: STA: SD16 258+00.00 MATCH LINE SEE SHEET: STA: SD14 249+00.00 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4946.24 4938.49 4938.39 4945.71 4937.97 4938.93 4937.91 4937.68 4937.15 274.72 LF 0.48%65.43 LF 0.64%104.58 LF 0.61%28.5 LF 0.74%111.65 LF 0.56% 220.35 LF 0.53%220.16 LF 0.40% 4942.04 4933.11 4933.11 4942.16 4933.25 4933.25 4942.81 4935.31 4934.43 4943.11 4935.57 4935.55 4944.81 4936.27 4936.19 4944.24 4936.51 4934.48 4945.87 274.72 LF 0.48% 104.58 LF 0.61% 63.43 LF 0.64% 28.5 LF 0.74% 111.65 LF 0.56% 28.09 LF 0.86% 28.09 LF 0.86% 220.35 LF 0.53%220.16 LF 0.40% 29.10 LF 0.48% 13.74 LF 1.67% 13.74 LF 1.67%29.10 LF 0.48% AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4925 4930 4935 4940 4945 4950 4955 4925 4930 4935 4940 4945 4950 4955 258+00259+00260+00261+00261+50 STA=259+06.73 SDMH E15 8'Ø FLAT TOP MH RIM=4948.35 INV IN (30" E)=4940.08 INV OUT (36" S)=4939.58 DEPTH=8.78 30''RCP 126.61 LF @ 0.40% 36''RCP 271.96 LF @ 0.40% STA=260+00.00 (STORM E16) STA=260+33.34 STORM E SDMH E16 6'Ø FLAT TOP MH RIM=4947.56 INV IN (30" N)=4940.78 INV IN (30" S)=4940.78 INV OUT (30" W)=4940.58 DEPTH=6.98 30'' RCP 24.96 LF @ 0.40% STA=260+59.80 INLET E17 15' TYPE 16 COMBO INLET TBC=4947.75 INV OUT (30" S)=4940.88 DEPTH=6.86 18" MIN. PROPOSED GRADE EXISTING GRADE STA=260+43.38 INV=4935.06 8" SANITARY CROSSING STA=260+53.38 TOP=4939.07 8" WATER CROSSING HGL HGL HGL HGL 100 yr HGL 4920 4925 4930 4935 4940 4945 4950 4920 4925 4930 4935 4940 4945 4950 239+50 240+00 241+00 242+00 243+00 244+00 245+00 245+50 24'' RCP 48.00 LF @ 0.40% 18" MIN. STA=244+47.34 TOP=4932.32 12" WATER CROSSING PROPOSED GRADE EXISTING GRADE STA=246+60.14 (STORM E) STA=240+00.00 STORM E3 SDMH E3 8'X8' BOX BASE MH RIM=4939.55 INV IN (60" N)=4931.60 INV IN (30" E)=4931.60 INV OUT (60" W)=4931.60 DEPTH=8.45 30''RCP 215.25 LF @ 0.40% STA=242+15.25 SDMH E3.1 4'Ø MH RIM=4942.10 INV IN (30" E)=4932.66 INV OUT (30" W)=4932.46 DEPTH=9.64 30''RCP 213.25 LF @ 0.40% STA=244+30.00 INLET E3.2 12' QUAD TYPE 16 COMBO INLET TBC=4939.89 INV IN (24" E)=4934.01 INV OUT (30" W)=4933.51 DEPTH=6.38 STA=244+81.00 INLET E3.3 9' TRIPLE TYPE 16 COMBO INLET TBC=4939.89 INV OUT (24" W)=4934.21 DEPTH=5.68 3' COVER MIN.HGL HGL HGL HGL HGL HGL HGL HGL HGL 100 yr HGL 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 21''SS 21''SS 21''SS 21''SS 21''SS 21''SS 12''W 12''W 12''W 12''W 12''W 21''SS 21''SS 21''SS 21''SS 21''SS 21''SS 21''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 21''SS 21''SS 16''SS 16''SS 16''SS 16''SS 16''SS 16''SS 16''SS 240+00 241+00 242+00 243+00 244+00 LOT 7 LOT 8 LOT 7LOT 6LOT 5LOT 4LOT 3LOT 2LOT 1 LOT 8 BLOCK 32 DELOZIER ROAD CRUSADER STREET (B) 3' STEEL SIDEWALK CHASE RIM OF MANHOLE EQUALS FLOWLINE OF CHASE. GRATE TO BE CENTERED IN SIDEWALK CHASE SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS 280.26 LF 8"PVC @ 0.43%292.05 LF 8"PVC @ 0.43% SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN E 258+00.00 260+59.80 50 5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING MATCH LINE SEE SHEET: STA: SD15 258+00.00 STA: SCALE: H: 1"=V: 1"= toSTORM DRAIN E3 240+00.00 244+81.00 50 5 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4939.95 4934.17 47.1 LF 0.63% 4939.91 4933.82 213.64 LF 0.40% 4933.51 4941.78 4932.43 4932.28 4939.48 4931.43 4931.43 4931.43 4940.88 4947.62 4940.63 4940.73 4940.44 4948.25 4939.90 4939.80 129.74 LF 0.42%274.72 LF 0.48% 4947.81 47.1 LF 0.63%213.64 LF 274.72 LF 0.48% 129.74 LF 0.42% 23.74 LF 1.05% 23.74 LF 1.05% 216.96 LF 0.50% 216.96 LF 0.50% AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4930 4935 4940 4945 4950 4955 4960 4930 4935 4940 4945 4950 4955 4960 259+00 260+00 261+00 PROPOSED GRADE EXISTING GRADE 30'' RCP 5.46 LF @ 1.00% STA=260+33.34 (STORM E) STA=260+00.00 STORM E16 SDMH E16 6'Ø FLAT TOP MH RIM=4947.56 INV IN (30" N)=4940.78 INV IN (30" S)=4940.78 INV OUT (30" W)=4940.58 DEPTH=6.98 STA=260+05.46 INLET E16.1 15' CDOT TYPE R INLET RIM=4947.82 INV OUT (30" N)=4940.84 DEPTH=6.98 100 yr HGL 4925 4930 4935 4940 4945 4950 4955 4925 4930 4935 4940 4945 4950 4955 249+00250+00251+00 24'' RCP 34.70 LF @ 1.00% EXISTING GRADE PROPOSED GRADE 18" MIN. STA=255+74.37 (STORM E) STA=250+00.00 STORM E13 SDMH E13 8'Ø FLAT TOP MH RIM=4945.94 INV IN (36" E)=4937.95 INV IN (24" N)=4938.95 INV OUT (36" S)=4937.75 DEPTH=8.19 STA=250+36.20 INLET E13.1 21' TYPE 16 COMBO INLET RIM=4945.95 INV OUT (24" S)=4939.30 DEPTH=6.65 STA=250+20.35 TOP=4937.40 8" WATER CROSSINGSTA=250+10.22 INV=4931.17 8" SANITARY CROSSING 100 yr HGL 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 269+50 270+00 271+00 272+00 272+50 STA=270+00.02 FES G 24" FES INV IN (24" E)=4931.29 24'' RCP 155.35 LF @ 1.50% STA=271+55.37 SDMH G1 4'Ø FLAT TOP MH RIM=4939.93 INV IN (24" N)=4933.82 INV OUT (24" W)=4933.62 DEPTH=6.31 24'' RCP 16.42 LF @ 1.50% STA=280+00.00 (STORM G2) STA=271+71.79 STORM G SDMH G2 4'Ø FLAT TOP MH RIM=4939.89 INV IN (24" E)=4934.27 INV IN (18" W)=4934.77 INV OUT (24" S)=4934.07 DEPTH=5.82 24'' RCP 24.06 LF @ 1.50% STA=271+95.86 INLET G3 12' TYPE 16 COMBO INLET TBC=4940.10 INV OUT (24" W)=4934.63 DEPTH=5.46 18" MIN. PROPOSED GRADE EXISTING GRADE STA=271+80.36 INV=4925.49 18" SANITARY STORM STA=271+90.36 TOP=4932.80 8" WATER CROSSING HGL HGL HGL 100 yr HGL CONCRETE CUT-OFF WALL 4931.21 4933.71 4933.52 4934.57 4934.63 4934.00 4935.00 154.39 14.81 1.96% 4940.08 4940.01 4940.14 4915 4920 4925 4930 4935 4940 4945 4915 4920 4925 4930 4935 4940 4945 279+00280+00281+00 STA=271+71.79 (STORM G) STA=280+00.00 STORM G2 SDMH G2 4'Ø FLAT TOP MH RIM=4939.89 INV IN (24" E)=4934.27 INV IN (18" W)=4934.77 INV OUT (24" S)=4934.07 DEPTH=5.82 18'' RCP 6.35 LF @ 2.00% STA=280+07.86 INLET G2.1 5' CDOT TYPE R INLET TBC=4940.02 INV OUT (18" E)=4934.90 DEPTH=5.13 PROPOSED GRADE EXISTING GRADE 100 yr HGL 4934.57 4934.63 4934.00 4934.78 6.40 2.34% 4940.17 4940.01 # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN E16 260+00.00 260+05.46 50 5 SD17 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN E13 250+00.00 250+36.20 50 5 STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN G 270+00.00 271+95.84 50 5 STA: SCALE:H: 1"=V: 1"= toSTORM DRAIN G2 280+00.00 280+07.86 50 5 SD17 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 4939.29 4945.71 4937.97 4938.93 4937.91 4940.63 4940.73 4940.44 4941.17 4947.61 4946.05 35.01 1.03% 35.01 1.03% 4947.81 7.08 6.21% 321.44 LF 2.01% 7.08 6.21% AB 12.18.17 Record Drawings JEP INV OUT (24" S)=4912.20 4912.48 REPRESENTS RECORD SURVEY DATA PROVIDED BY NORTHERN ENGINEERING MATT E. LOCKWOOD, PLS PLS.0038316 DATED: 10.05.17 06.30.1607.07.17 4915 4920 4925 4930 4935 4940 4945 4950 4955 4915 4920 4925 4930 4935 4940 4945 4950 4955 289+50290+00291+00292+00293+00294+00295+00296+00297+00298+00 STA=290+00.00 FES PO 18" FES INV IN (18" N)=4932.56 18'' RCP 295.72 LF @ 0.21% STA=292+95.72 SDMH PO1 4'Ø FLAT TOP MH RIM=4937.31 INV IN (18" N)=4933.17 INV OUT (18" S)=4933.17 DEPTH=4.14 18'' RCP 330.20 LF @ 0.20% STA=296+25.92 SDMH PO2 4'Ø FLAT TOP MH RIM=4939.92 INV IN (18" N)=4933.83 INV OUT (18" S)=4933.83 DEPTH=6.08 18'' RCP 303.89 LF @ 0.34% CITY OF FORT COLLINS 100-YR WATER SURFACE ELEVATION = 4935.81 CALCULATED 180 CFS WATER SURFACE ELEVATION = 4933.08 CONCRETE PAD TO BE FLUSH w/ EXISTING SURFACE IN DITCH CONCRETE PAD w/ CUTOFF WALLS (H:2.5'-S, 4.9'-N W:3' L:23') SEE NOTE 17 EXISTING GROUND LAKE CANAL # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toPOND OUTFALL 290+00.00 298+00.00 50 5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R MATCH LINE SEE SHEET: STA: SD19 298+00.00 SD18 SD19 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING 17. CONCRETE PAD TO BE DESIGNED TO SUPPORT H-20 LOADING. 4933.80 4933.81 4939.40 4933.08 4933.10 4937.89 4932.49 296.0 LF 0.20% 330.00 LF 0.21% 303.00 LF 0.30% 0.21% 330.00 296.0 LF 0.20% 303.00 LF 0.30% AB 02.20.18 Record Drawings JEP 06.30.1607.07.17 4910 4915 4920 4925 4930 4935 4940 4945 4950 4910 4915 4920 4925 4930 4935 4940 4945 4950 298+00299+00300+00301+00302+00303+00303+50 18''RCP 303.89 LF @ 0.34% STA=299+29.81 SDMH PO03 4'Ø FLAT TOP MH RIM=4940.08 INV IN (15" W)=4934.86 INV OUT (18" S)=4934.86 DEPTH=5.21 PROPOSED GROUND EXISTING GROUND STA=299+19.81 INV=4924.66 12" SANITARY CROSSING STA=299+00.00 TOP=4931.91 16" WATER CROSSING 15''PIP145.56LF@7.22% 18''RCP 123.62 LF @ 1.01% STA=302+11.11 HEADWALL PO05 CONCRETE PAN W/HEADWALL REFER TO SHEET OG03 FOR DETAIL RIM=4932.00 INV OUT (18" SE)=4928.50 DEPTH=0.00 STA=300+75.36 INV=4923.00 BOTTOM FLOOR OF VAULT STA=300+87.70 INV=4932.33 TOP OF VAULT STA=300+80.87 INV=4937.00 TOP OF HATCH STA=300+75.36 INV=4932.33 TOP OF VAULT STA=300+87.70 INV=4923.00 BOTTOM FLOOR OF VAULT STA=300+87.64 PUMP VAULT PO04 (IN) 11'X19'X8.5' CONCRETE VAULT RIM=4928.96 INV IN (18" NW)=4927.25 CONSTRUCTION OF THIS LINE TO BE COORDINATED W/PUMP INSTALLER # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toPOND OUTFALL 298+00.00 302+13.80 50 5 MATCH LINE SEE SHEET: STA: SD18 298+00.00 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R SD18 SD19 ( IN FEET ) 1 inch = ft. 050 50 50 100 150 LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING 17. CONCRETE PAD TO BE DESIGNED TO SUPPORT H-20 LOADING. 1 07.07.17 Pond Revisions JEP 4928.35 4934.70 4934.70 4939.90 AB 02.20.18 Record Drawings JEP 0.30%303.00 4922.95 4922.95 4937.25 4927.28 06.30.1607.07.17 8''SS 8''SS 8''SS 8''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 6''W 6''W 6''W 8''W 8''W 8''W 8''W (UNPLATTED) 300+00 301+00 302+00 303+00 304+00 305+00 306+00 307+00 308+00 309+00 310+00 CRUSADER STREET (B)LOT 25 LOT 24 LOT 17 LOT 18 LOT 19 LOT 20 LOT 23 LOT 22 LOT 21 TRACT D TRACT C TRACT E BLOCK 3 PRIVATE DRIVE CRUSADER STREET PRIVATE DRIVE TIGERCAT WAY SANITARY LINE 1-4 SEE SHEET SS06 IRRIGATION LINE SEE SHEET SD21 STORM DRAIN A3 SEE SHEET SD02 30' 20' 4915 4920 4925 4930 4935 4940 4945 4950 4915 4920 4925 4930 4935 4940 4945 4950 299+50 300+00 301+00 302+00 303+00 304+00 305+00 306+00 307+00 308+00 309+00 310+00 310+50 STA=300+00.00 SDMH FPO-5 4'Ø MH RIM=4943.53 INV IN (24" E)=4926.45 DEPTH=17.07 24''RCP 329.27 LF @ 0.20%24''RCP 241.13 LF @ 0.20% STA=303+29.27 SDMH FPO-4 4'Ø MH RIM=4946.34 INV IN (24" E)=4927.11 INV OUT (24" W)=4927.11 DEPTH=19.23 STA=305+70.40 SDMH FPO-3 4'Ø MH RIM=4942.51 INV IN (24" E)=4927.59 INV OUT (24" W)=4927.59 DEPTH=14.91 24''RCP 204.00 LF @ 0.20% STA=308+79.65 SDMH FPO-1 4'Ø MH RIM=4941.62 INV IN (24" NE)=4928.21 INV OUT (24" W)=4928.21 DEPTH=13.41 24''RCP 143.49 LF @ 0.20% STA=310+23.14 FPO POND OUTLET STRUCTURE INV OUT (24" SW)=4928.50 STA=307+74.40 SDMH FPO-2 4'Ø MH RIM=4941.12 INV IN (24" E)=4928.00 INV OUT (24" W)=4928.00 DEPTH=13.12 24''RCP 105.25 LF @ 0.20% PROPOSED GRADE EXISTING GROUNDSTA=300+17.62 INV=4935.88 18" IRRIGATION CROSSING STA=305+60.27 TOP=4937.04 8" WATER CROSSING STA=308+09.76 TOP=4935.96 8" WATER CROSSING STA=309+01.03 INV=4925.65 12" SANITARY CROSSING # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP STA: SCALE: H: 1"=V: 1"= toFUTURE POND OUTLET 300+00.00 309+98.12 50 5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO R LEGEND: NOTES: 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEEER PRIOR TO CONSTRUCTION. 2. JOINTS ON ELLIPTICAL PIPES SHALL BE TONGUE AND GROOVE WITH FLEXIBLE JOINT SEAL COMPOUND PER THE PIPE MANUFACTURER STANDARDS AND AS APPROVED BY CITY INSPECTOR. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING LENGTH INCLUDES FLARED END SECTIONS. 4. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS. 6. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARD DETAIL D-3. CONTRACTOR SHALLVERIFY THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 7. SEE DETAILS FOR RIPRAP PAD SIZING. 8. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE. 9. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. 10. SANITARY SEWER INVERTS ARE SHOWN FOR INFORMATION ONLY. SEE SHEET SS01-SS35 FOR FINAL ELEVATIONS. 11. WATERLINE INVERTS ARE SHOWN FOR INFORMATION ONLY. THE CONTRACTOR SHALL VERIFY THAT 18" VERTICAL SEPARATION IS MAINTAINED BETWEEN WATER LINE AND STORM PER ELCO STANDARD DETAILS. 12. SEE SHEETS EX01-EX02 FOR EXISTING BOUNDARY CORNER COORDINATES. 13. ALL STORM MANHOLE LIDS TO BE ROTATED OUT OF CURB AND GUTTER, CROSSPANS AND SIDEWALKS. 14. MANHOLE RIM ELEVATION ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE IN PAVED AREAS. 15. SEE SHEET DT07 FOR HEADWALL DETAILS AND SHEET GR05 FOR SPOT ELEVATIONS OF HEADWALL. 16. THE NATURAL HABITAT BUFFER ZONE SHALL BE MAINTAINED AS A NATIVE LANDSCAPE PER THE APPROVED LANDSCAPE PLAN. S PROPOSED STORM INLET EASEMENT LINE PROPOSED LOTLINE PROPOSED RIGHT-OF-WAY PROPERTY BOUNDARY PROPOSED CURB & GUTTER EXISTING GAS EXISTING OVER-HEAD ELECTRIC PROPOSED FIBER OPTIC EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED FIRE HYDRANT PROPOSED RESIDETIAL SERVICE PROPOSED SEWER SERVICE EXISTING SANITARY SEWER PROPOSED SANITARY SEWER EXISTING WATER MAIN PROPOSED WATER MAIN W 8" SS SSSS 8" 4900 4900 PROPOSED CONTOUR EXISTING CONTOUR PROPOSED WATER LINE LOWERING ( IN FEET ) 1 inch = ft. 050 50 50 100 150 SD20 1 07.07.17 Pond Revisions JEP 4926.79 4926.79 4946.22 4928.35 0.36%143.24 4927.84 4927.84 4941.84 0.20%107.460.48%203.14 4927.62 4927.62 4940.92 0.20%241.130.37%327.38 4926.79 4926.79 4946.22 4925.57 4943.22 0.37%327.38 0.20% 241.13 0.48%203.14 0.20% 107.46 0.36% 143.24 AB 02.20.18 Record Drawings JEP 06.30.1607.07.17 LOT 19 LOT 18LOT 20 LOT 2LOT 1 BLOCK 25 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 18''SS 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W CHASE CL 4940.05 CHASE CL 4940.27 CHASE CL 4940.08 CHASE CL 4940.13 ALLEY B LOT 2 LOT 15LOT 1314 9 LOT 10 LOT 1 LOT 16 LOT 11 LOT 12 BLOCK 24 BLOCK 14 CHASE CL 4947.14 CHASE CL 4947.50 CHASE CL 4947.17 CHASE CL 4947.24 ALLEY A QUINBY STREET # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3760 E. 15th Street, Suite 202 Loveland, CO 80538 970.800.3300 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved SHEET TITLE: Date: Drawn By: Project No: Checked By: HFHLV0001.01 12.05.16 EAST RIDGE HOLDINGS 4801 Goodman Rd. Timnath, CO 80547 970.674.1109 KEYMAP ( IN FEET ) 1 inch = ft. 020 20 20 40 60 AB 02.20.18 Record Drawings JEP DASSAULT STREET AND ALLEY B SIDEWALK CHASEB QUINBY STREET AND ALLEY A SIDEWALK CHASEA 06.30.1607.07.17 12/15 Page 5 V. Storm Drain Inlets - FCSCM Vol.1, Ch.6, Sec. 3 A. Construction/Installation: All storm drain inlets have been constructed in accordance with the approved construction plans. 1.The size and type of inlets are consistent with the inlets shown on the approved construction plan. Indicate by writing “Verified” on each inlet on the plan sheet or list on a separate document the inlet number(s), type and size (length). If the inlet installed is other than the one on the approved construction plan detail sheet, provide the name and source of the detail with justification for equal or better capacity. 2.The size of the inlet opening is consistent with the approved detail. (Check height and width.) 3.The elevation of the grate (if applicable) is at the elevation shown on the street profile or as indicated by a spot elevation on the construction plans. 4.The as-built invert elevations of all pipes entering and leaving the inlet are shown on the plan and profile sheets within construction tolerance of 0.2 feet. If substantially different, provide justification and capacity calculations to show the capacity is not affected or propose mitigation. 5.The as-built size of the inlet box is as shown on the construction plans or an explanation or justification is attached. 6.All inlet covers are stenciled or stamped with the following designation: NO DUMPING – DRAINS TO POUDRE RIVER. VI.Culverts - FCSCM Vol.2, Ch.9 A. Construction/Installation: All culverts have been constructed and/or installed in accordance with the approved construction plans. 1.All culvert sizes have been verified as indicated on the as-built construction plans as correct. 2.The culvert material type for all culverts installed is as on the approved construction plans and is indicated on the as-built plans. 3.The as-built invert “in and out” elevations have been verified and are indicated on the as-built construction plans. 4.The culvert headwalls or wing walls have been installed as shown on the approved construction plans. Headwalls or wing walls may be needed in the as-built conditions onsite if the slopes adjacent to the culvert are greater than 4:1. Please note areas needing stabilization in the certification narrative. An alternative to consider is a turf reinforcement mat (TRM). VII.Sub-Drains A. Construction/Installation: All sub-drains shown on the construction plans have been installed in accordance with those plans. Sub-drains installed with the sanitary sewer are to be verified on the sanitary sewer plan and profile sheets of the construction plans. (NOTE: Indicate any sub-drains installed after the plans were approved on the as-built plans.) 1.The size of the sub-drains are as approved on the construction plans and are indicated on the as- built plans. 2.The type of sub-drain, in particular the perforated and non-perforated sections of the drain, are as indicated on the approved construction plans. 12/15 Page 6 3.The cover requirements per the construction plans are provided. 4.The cleanouts have been installed at the locations shown on the construction plans and are accessible for cleaning. (Cleanouts can be buried a maximum of 6 inches deep with their locations marked.) 5.The backfill materials for sub-drains are as shown on the approved construction plans. (This includes the type, depth and width.) 6.The geo-textile liner completely wraps the sub-drain and the permeable backfill material unless shown otherwise on the approved construction plans. (Sub-drain pipe wrapped in a sock filter material is accepted only if approved prior to installation.) VIII.Curb Cuts A. Construction: All curb cut openings are constructed in accordance with the approved construction plans. 1.The size (width) of the curb cut opening is as shown on the approved construction plans. 2.The curb cut openings tie into a downstream swale, pipe, or other appurtenances with a smooth transition and there no obstructions such as riprap or sod impeding the flow downstream of the curb cut. IX.Sidewalk Culverts & Chases A. Construction/Installation: All sidewalk culverts have been installed at the locations shown on the approved construction plans. 1.The size (width and length) of the culverts are as shown on the approved construction plans. 2.The cover plate is a minimum 5/8-inch galvanized plate bolted to a galvanized angle iron per the detail shown on the approved construction plans or per the City’s detail. 3.The sidewalk culvert invert “in and out” elevations have been verified and are indicated on the as-built plans. 4.The sidewalk culvert opening is as shown on the approved construction plans or per the City’s detail. 5.There is a smooth transition both on the inlet and outlet ends of the sidewalk culvert with no obstructions such as riprap or sod impeding the flow into or out of the sidewalk culvert. X. Site Grading A. Construction: All common open spaces have been graded in accordance with the approved construction plans. 1.The grading on all common open spaces bordering private lots has been verified as correct and the as-built rear lot corner elevations have been shown on the as-built plans. 12/15 Page 7 2.The as-built contours for “overlot grading” are shown on the as-built construction plans for all common open spaces, tracts, outlots, etc. If not in compliance, please attach a narrative describing the situation for noncompliance and when it may be corrected. An escrow for overlot grading may be required. (NOTE: Residential Lot Grading Certification is a separate process from this Overall Site Certification. It is understood that residential lots will be brought to final grade once the foundation is backfilled so they may be lower than the plan shows at this Overall Site Certification stage.) 3.All turf reinforcement mats (TRMs) have been installed as shown on the approved construction plans and the slopes are stabilized. XI.Riprap - FCSCM Vol.1, Ch.7, Sec.4.4.4.3 A. Construction: All riprap has been installed in the locations and sizes indicated on the approved construction plans. XII.Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7 A. Construction: All fabric has been installed in the locations and sizes indicated on the approved construction plans. 1.All fabric was installed per the details on the approved construction plans. XIII.Post-Construction Site Cleanup - FCSCM Vol.3, Ch.7 A. Construction: All construction debris and obstructions of any kind have been removed from drainage paths. 1.All construction debris has been removed except in staging area(s). 2.All ruts have been smoothed out in all construction areas. 3.All areas needing reseeding have been identified and future stabilization goals have been coordinated with the Erosion Control Inspector and in accordance with FCSCM Vol.2 Chapter 12. Note the area needing stabilization in the narrative. XIV.Certification of Other Permanent BMPs - FCSCM Vol.2, Ch.8, Sec.2 & FCSCM Vol.2, Ch.12 A.The construction of channel drop structures is in accordance with the approved plan both in location, horizontal dimensions and cross-section. XV.Certification of LID and Water Quality Facilities - FCSCM Vol.3, Ch.4 A.Attached are the During Construction Inspection Checklist for Low Impact Development (LID) and other items to be verified during construction, along with pictures and other required documentation. 12/15 Page 1 This checklist is to be completed during construction and included with the Overall Site and Drainage Certification.  Use “Yes” for items completed as described.  Use “N/A” for items that are not applicable to the site being certified.  If any blanks are “No,” attach an explanation referencing the item number below. I. Compaction A. YES All berms and embankments meet the compaction requirements as specified in the project geotechnical report or comply with the City’s standard, which is “soils should be compacted within a moisture content range of 2% below to 2% above optimum moisture content and compacted to 95% of the Maximum Standard Proctor Density (ASTM D698).” Compaction requires verification during construction. Provide testing log from contractor/engineer. See attached compaction test results from Soilogic II. Storm Drain Pipe Installation Requirements A. YES The pipe trenches have been compacted in accordance with Section 02225-3.07.A.1. of the Fort Collins Development Construction Standards (e.g., the trenches in the roadways are to be 95% of maximum density and all other areas are to be at 90%, both in accordance with ASTM D698). See attached compaction test results from Soilogic III. Riprap - FCSCM Vol.1, Ch.7, Sec.4.4.4.3 A. YES The riprap bedding is a granular bedding of the gradation and thickness indicated on the approved construction plans. B. YES A filter fabric was installed instead of granular bedding and is the material shown on the approved construction plans or was an approved equal. Provide documentation for an approved equal. C. YES The riprap is the gradation shown on the approved construction plans with a D50 of D. YES The riprap thickness is as shown on the approved construction plans and extends to the horizontal limits shown. E. YES The riprap is buried to the depth indicated on the approved construction plans. (A minimum of 6 inches of soil is required.) IV. Permanent Erosion Control Fabric - FCSCM Vol.1, Ch.7 A. N/A All fabric was installed per manufacturer’s specifications. V. Certification of Other Permanent BMPs - FCSCM Vol.2, Ch.8, Sec.2 & FCSCM Vol.2, Ch.12 A. YES All cut-off walls have been installed in accordance with the approved construction plans. (Cut-off walls are required for irrigation ditch crossings of storm drain pipes and at the end of flared end sections.) DURING CONSTRUCTION INSPECTION CHECKLIST To be completed by Construction Superintendent 12/15 Page 2 Permeable Interlocking Concrete Pavers Item/Activity Yes No N/A Documentation/Submittal Requirements Excavation Post-excavation infiltration rates are consistent with design infiltration capacity (for “full or partial infiltration” designs) X Impermeable Liner Impermeable liner meets design specifications X Impermeable liner attached to concrete perimeter wall X Impermeable liner is not exposed X Any penetrations of the impermeable liner have been sealed and checked for water-tightness. X Concrete Cut-Off Wall Meets specifications for: X - Dimensions X - Reinforcement X - Footings X Underdrain System Underdrain pipe is per design specifications X At least one cleanout is provided per underdrain lateral X Cleanout pipe is not perforated X Cleanout covers are installed and watertight X Underdrain is NOT wrapped in geotextile fabric X Underdrain orifice plate installed at outlet structure X Underdrain integrity tested after backfilling using TV and/or water test X Aggregate Base coarse (e.g., #2/4) has 90% fractured faces X Bedding coarse (e.g., #89) is thoroughly washed X Sub-base materials are installed and compacted according to manufacturer’s specifications X Protection During Construction PICP area is protected from construction site sediment, including runoff from the upstream catchment and construction equipment traffic X Close Out Upstream catchment is stabilized prior to diverting runoff into PICP system X 12/15 Page 3 Bioretention Cells Item/Activity Yes No N/A Documentation/Submittal Requirements Excavation Heavy equipment did not travel over bioretention cell during excavation X Bottom of cell was “ripped” after excavation X Photograph before/after “ripping” Bottom of cell is flat and level X Photograph attached Excavated area is protected/surrounded by sediment/runoff control BMPs during construction X Photograph attached Inlet Overflow inlet elevation is set above bioretention media per plan (typically 12 inches) X Overflow inlet invert elevation is at least 3 inches below containment wall/berm (to direct overflow into inlet) X Measure/record distance between inlet and top of containment wall/berm Upstream catchment drains to inlet X Forebay Forebay is installed according to design specifications X Forebay has flat, concrete bottom X Outlet Structure/Overflow Outlet structure/overflow elevation is confirmed X Measure/record distance from overflow to top of media filter Impermeable Liner Impermeable liner meets design specifications X Impermeable liner attached to concrete perimeter wall X Impermeable liner is not exposed X Underdrain System Underdrain pipe is per design specifications X Photograph Attached At least one cleanout is provided per underdrain lateral X Photograph Attached Cleanout pipe is not perforated X Photograph Attached Cleanout covers are installed and watertight X Underdrain is NOT wrapped in geotextile fabric X Underdrain orifice plate installed at outlet structure X Underdrain integrity tested after backfilling using TV and/or water test X Water tested 12/15 Page 5 12/15 Page 6 12/15 Page 7 12/15 Page 8 12/15 Page 9 12/15 Page 10 12/15 Page 11 12/15 Page 12 12/15 Page 13 12/15 Page 14 12/15 Page 15 12/15 Page 16 12/15 Page 17 12/15 Page 18 No r t h W e s t No r t h E a s t So u t h W e s t So u t h E a s t