Loading...
HomeMy WebLinkAboutLot Certifications - 08/20/2019Accepted 8/20/2019 WL X X X X XX XXX X X X X X X X X X X X FD C TSALPOLYN DUCTILEIRON TSALPOLYN DUCTILEIRON TSALPOLYN DUCTILE IRON TSALPOLYN DUCTILEIRON S W W W W W W W W W W W W W W W W W W W F E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/T/C E/ T / C E/ T / C W W W W W W W W W W W W W BASIN A6 INV. OUT=4917.93 (NE) FG=4920.72 BASIN A5 INV. IN=4917.80 (SW) INV. OUT=4917.80 (E) FG=4920.66 BASIN A3.1 INV. OUT=4917.62 (SE) FG=4920.09 45° BEND A4 INV. IN=4917.74 (W) INV. OUT=4917.74 (NE) FG=4918.51 TEE A3 INV. IN=4917.49 (SW) INV. IN=4917.43 (NW) INV. OUT=4917.49 (NE) FG=4918.26 BASIN A2 INV. IN=4917.30 (SW) INV. OUT=4917.33 (E) FG=4919.24 38 . 4 4 L F 8" H D P E @ 0 . 5 0 % 12. 3 3 L F 8" H D P E @ 0 . 5 0 % 25.33 LF 8" HDPE @ 0.50% 49 . 7 6 L F 8 " H D P E @ 0 . 5 0 % 9.50 LF 8" HDPE @ 2.00% 10' 20'4.87' TRAIL 6.5' WALK 29.03 L F 8 " H D P E @ 4 . 3 0 % CONCRETE COLLAR A1 INV. IN=4916.08 (W) FG=4916.85 5.0%2.5% 0. 8 % 3.2% 2.4% 1.9% 2.1% 2.0% 4.6%3.4% 2. 0 % 1. 6 % 4.3%2.0% 2. 8 % 3.0% 2.1% 2.8 % 4.1% 19 . 8 % 3.7 % 7.0 % 2. 0 % 2.0% 3.9% 2.8 % 4. 5 % 4. 5 % 2. 0 % 2. 0 % 0.6% 1.7% (1 . 3 % ) (0.9%) (1 . 3 % ) (0.4%) (2.1%) (4 . 3 % ) (1.6%) (1 . 1 % ) 0.5% 0.9% 1.7% 4.8% 8. 1 % 0. 7 % 33 . 9 % 20 . 8 % 2.0% 6.2% 2. 0 % 9:1 20 : 1 9:1 9:1 9:1 4:1 4:1 4: 1 4.5' TRAIL 4.6% 4.8 % 4.9 % 1.9% 4:1 4' TRAIL 21 . 5 7 20.9 3 21.9 7 21.9 7 22.02 21.5 5 21 . 2 1 21 . 1 0 20.0 9 21.12 21.12 20.9 4 21.02 21.06 21.10 22 . 1 1 (21.04) 21.59 22. 1 1 22 . 1 2 22.39 22.4 7 (2 2 . 9 2 ) (2 2 . 7 5 ) 20.3 2 22.0 1 22.1 222. 1 2 22. 0 3 21 . 7 5 21 . 8 6 21. 6 8 22 . 0 2 21 . 3 3 21 . 5 0 21 . 5 8 21. 3 8 21. 3 0 20.8 2 20 . 6 8 20. 6 0 18.4 8 18.7 5 18.75 18.82 18.59 18.80 18.58 18.38 18.82 17 . 7 5 18.46 17. 3 4 16.8 4 17.6 2 21 . 4 4 21.4 4 21 . 6 2 HP 22 . 0 3 20 . 8 7 22. 7 0 24 . 3 5 22 . 1 2 21 . 4 5 21.1 2 20.9 7 20.9 7 21 . 6 3 21 . 7 1 21 . 4 4 21.34 21 . 3 4 22 . 1 1 22.11 22.11 21.44 22. 0 3 22.03 21 . 5 0 21.5 3 21 . 7 1 21. 4 4 21.43 22. 1 1 22. 1 2 22. 0 2 21. 4 4 20 . 6 6 22.12 (21.56) (21.78) (21 . 8 5 ) (21.11) (20.98) (20.9 3 ) (20.90) (2 0 . 6 6 ) (20 . 7 7 ) 20.99 (16 . 0 8 ) FFE=22.12 21.34 EMERGENCY OVERFLOW PATH 22 . 1 2 20.90 (1) 6" RISER SWALE FENCE (SEE LANDSCAPE PLANS) EXISTING METER PIT AND CURBSTOP TRASH ENCLOSURE (SEE ARCHITECT PLANS) GRAVEL TRAIL (SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION) RETAINING WALL HEIGHT VARIES 18"-30" (SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION) FENCE (SEE LANDSCAPE PLANS) RAMP 21.8 9 21.92 21 . 8 4 21 . 9 6 22. 0 9 SWALE EXISTING RIPRAP RUNDOWN (14 . 3 9 ) 18.8 0 (12.5 5 ) 22.1 2 22.13 23.4 6 22.09 20.8821. 1 2 23.85 23.53 20.33 (13 . 0 0 ) (1 8 . 0 0 ) 22.59 22.19 24.6 5 22.03 20 . 5 9 (15 . 5 9 ) 4: 1 22.04 22 . 0 4 22.04 15 . 8 % ( A B ) TSALPOLYN DUCTILEIRON TSALPOLYN DUCTILEIRON TSALPOLYN DUCTILEIRON TSALPOLYN DUCTILEIRON C.O . Sheet BU C K I N G H O R S E V E T C L I N I C Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . E N G I N E E R N G I E H T R O N R N FO R T C O L L I N S : 3 0 1 N o r t h H o w e s S t r e e t , S u i t e 1 0 0 , 8 0 5 2 1 GR E E L E Y : 8 2 0 8 t h S t r e e t , 8 0 6 3 1 97 0 . 2 2 1 . 4 1 5 8 no r t h e r n e n g i n e e r i n g . c o m of 01 LEGEND: EXISTING WATER SERVICE EXISTING CURB/GUTTER FLOWLINE 4950 4:1PROPOSED SLOPE PROPOSED CROSS GRADE CONCENTRATED FLOW DIRECTION PROPOSED STORM DRAIN WITH INLET PROPOSED CONTOUR EXISTING CONTOUR 79.45PROPOSED FINISH GROUND ELEVATION (79.45) LIGHT POLE 2.0% PROJECT BOUNDARY EXISTING SANITARY SEWER LINE WEXISTING WATER LINE E/T/CEXISTING ELECTRIC, TELEPHONE, AND CABLE TSALPOLYN DUCTILEIRON SSEXISTING SANITARY SEWER LINE EXISTING GROUND ELEVATION GENERAL NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER AND SANITARY SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS CONSTRUCTION STANDARDS, LATEST EDITION. 3.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 4.ALL EXISTING SANITARY SEWER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO BE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700). 5.ALL EXISTING WATER SERVICES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ALL SEWER SERVICES TO THE UNUSED SHALL BE ABANDONED AT THE MAIN AND COORDINATED WITH FORT COLLINS UTILITIES (970-221-6700) 6.PRIOR TO ORDERING MATERIAL AND MOBILIZING, CONTRACTOR SHALL FIELD LOCATE AND VERIFY ELEVATIONS OF ALL CONCRETE AND ASPHALT TIE-INS, EXISTING SEWER MAINS, WATER MAINS, AND ALL OTHER UTILITIES AT THE POINTS OF CONNECTION SHOWN ON THE PLANS. 7.CONTRACTOR IS RESPONSIBLE FOR ALL THE REPAIRS AND REPLACEMENTS OF ANY DAMAGED CURB AND GUTTER. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8.ALL STORM SEWER SHALL BE PRIVATELY OWNED AND MAINTAINED. 9.ALL BASINS SHALL BE 12" NYLOPLAST DRAIN BASINS WITH 12" DOMED GRATE UNLESS OTHERWISE NOTED. 10.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 11.EROSION CONTROL PRACTICES, SITE PROTECTION, AND REVEGETATION METHODS SHALL FOLLOW CITY REGULATIONS. 12.REFER TO SITE PLAN, LANDSCAPE PLAN, AND PLAT FOR ADDITIONAL INFORMATION. 13.ALL SPOT ELEVATIONS ARE FINISH GRADE UNLESS CALLED OUT OTHERWISE. BENCHMARK/BASIS OF BEARING PROJECT DATUM: NGVD 29 BENCHMARK #1: CITY OF FORT COLLINS BENCHMARK 4-07 SOUTHWEST CORNER OF TIMBERLINE RD. AND BEAR MOUNTAIN DR. DUE NORTH OF NEW POLICE BUILDING ON SOUTHWEST CORNER OF A CATCH BASIN. ELEVATION = 4939.66 BENCHMARK #2: CITY OF FORT COLLINS BENCHMARK 17-92 300 FEET SOUTH OF THE SOUTHWEST CORNER OF EAST DRAKE RD. AND TIMBERLINE RD, IN THE TOP OF AN IRRIGATION STRUCTURE. ELEVATION = 4935.51 PLEASE NOTE: THIS PLAN SET IS USING NGVD29 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NAVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NAVD88 = NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) + 3.18 PROPOSED SWALE FLOWLINE GRAD GR A D I N G P L A N CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what's below. before you dig.Call R NORTH ( IN FEET ) 010 10 20 30 1 INCH = 10 FEET 01 RECORD DRAWING S W F FDC TSALPOLYN DUCTILEIRON TSALPOLYN DUCTILE IRON TSALPOLYN DUCTILEIRON TSALPOLYN DUCTILEIRON 4025 Automation Way, Suite C4 Fort Collins, CO 80525 970-232-9645 www.WashburnSurveying.com Sheet 1 of 1 Project #: 2019-0009 Date last revised: Aug 8, 2019 Scale: 1"=15' Drawn: CDB Scale: 1"=15' MOORE ANIMAL HOSPITAL AS-BUILT EXHIBIT LOT 3, BLOCK 4, BUCKINGHORSE FILING 2, LOCATED IN SECTION 20, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO ELEVATIONS SHOWN ARE FROM AN AS-BUILT SURVEY OF THE SITE PERFORMED ON JULY 22 AND AUGUST 8, 2019 DETAIL A SCALE: 1"=5'