Loading...
HomeMy WebLinkAboutLot Certifications - 08/24/20202/14/17 Page 1 CERTIFICATION OF LOT GRADING Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e) Date: Address: Lot: Block: Subdivision: Permit Application #: Larimer County Parcel #: Larimer County Reception #: (on development agreement) I, (print) , a Colorado registered professional engineer, verify that construction of all stormwater facilities and grading is complete and hereby submit this certification. Please answer the following questions by initialing the appropriate response. For each question initialed “No,” attach an explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots. 1.Certification includes attached Stormwater-approved grading plan. (NOTE: City’s Building Department does not approve grading plans). 2.Certification includes the attached as-built survey dated (must be within 60 days of the date the certification is submitted) accurately and truthfully depicting elevations for: Top of foundation/finished floor Finished grade on each side of the structure Quarter points along each lot line (not more than 50 feet apart) Break points/high points Swales Berms Retaining walls Air conditioning pads Window wells Any other appurtenance(s) within an easement 3.All elevations are within a 0.2 foot tolerance of the approved grading plan. 4.The top of foundation is at least 6 inches above the highest grade surrounding the structure. 5.There is a minimum grade of 5% away from the structure within the first 5 to 10 feet adjacent to the residence. 6.All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single family lots when the swale is draining the runoff from only two adjoining properties) and are not steeper than 33% (3:1). 7.All flow lines of stormwater drainage swales are a minimum of 6 inches below the elevation of ground adjacent to the structure and will direct drainage as shown on the Stormwater-approved grading plan. 8.All downspout locations and discharge directions are shown on the as-built survey. Runoff is directed into an appropriate drainage system or lot line swale, and it is not directed onto neighboring properties. No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes August 19, 2020 Bucking Horse Filing Three 2157 Yearling Drive B2001982 Fort Collins, CO 80525 8720367004 4 1 20140047537 Troy W. Campbell 08/12/2020 TC TC TC TC TC TC TC TC Undetermined - the house is being sold with no landscaping included. Home buyer to hire landscape company. i2 Consultants, Inc. 16911 Potts Place, Mead, CO 970.217.9148 troy@i2-consultants.com Exceptions to the Site Grading Policies/Requirements August 20, 2020 RE: 2157 Yearling Drive, Fort Collins, CO Lot 4, Block 1, Bucking Horse Filing Three (Building Permit No. B2001982) EXCEPTIONS The record survey indicates several elevations are outside of the 0.2’ tolerance: · The top of foundation elevation is 1.97’ below approved grading design; · The high point along the northern property line is 0.75’ below grading design; · The mid-point of the northern property line is 1.43’ higher than grading design; · The southern property corner is 0.24’ below grading design. The grade away from the southwestern side of the house is less than 5%; the minimum grade away from the house is 2.6%. 2157 Yearling Drive Fort Collins, CO Lot 4, Block 1 Bucking Horse Filing Three Sheet G1 Scale: 1"=40' North