CERTIFICATION OF LOT GRADING
Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e)
Date:
Address:
Lot: Block:
Subdivision:
Permit Application #:
Larimer County Parcel #:
Larimer County Reception #:
(on development agreement)
I, (print) , a Colorado registered professional engineer, verify that construction
of all stormwater facilities and grading is complete and hereby submit this certification.
Please answer the following questions by initialing the appropriate response. For each question initialed “No,” attach an
explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots.
1.Certification includes attached Stormwater-approved grading plan. (NOTE: City’s
Building Department does not approve grading plans).
2.Certification includes the attached as-built survey dated (must be within 60
days of the date the certification is submitted) accurately and truthfully depicting
elevations for:
Top of foundation/finished floor
Finished grade on each side of the structure
Quarter points along each lot line (not more than 50 feet apart)
Break points/high points
Swales
Berms
Retaining walls
Air conditioning pads
Window wells
Any other appurtenance(s) within an easement
3.All elevations are within a 0.2 foot tolerance of the approved grading plan.
4.The top of foundation is at least 6 inches above the highest grade surrounding the
structure.
5.There is a minimum grade of 5% away from the structure within the first 5 to 10 feet
adjacent to the residence.
6.All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single
family lots when the swale is draining the runoff from only two adjoining properties)
and are not steeper than 33% (3:1).
7.All flow lines of stormwater drainage swales are a minimum of 6 inches below the
elevation of ground adjacent to the structure and will direct drainage as shown on the
Stormwater-approved grading plan.
8.All downspout locations and discharge directions are shown on the as-built survey.
Runoff is directed into an appropriate drainage system or lot line swale, and it is not
directed onto neighboring properties.
No Yes
No Yes
No Yes
No Yes
No Yes
No Yes
No Yes
No Yes
July 27, 2021 Bucking Horse Filing Three
2151 Yearling Drive B2100253
Fort Collins, CO 80525 8720367003
3 1 20140047537
Troy W. Campbell
07/27/2021
TC
TC
TC
TC
TC
TC
TC
TC
2/14/17 Page 2
9.A smooth transition with no vertical offset (step) in grade is provided at the lot line to all
adjacent properties.
10.The grading of this lot does not adversely affect neighboring properties or City
infrastructure.
11.Landscaping has been completed prior to survey. If not, please indicate who will be
responsible for completing landscaping:
12.Final site cleanup has been completed.
13.I personally visited the site as part of the certification process, and in my professional
opinion, the as-built survey is an accurate representation of the site conditions..
No Yes
No Yes
No Yes
No Yes
No Yes
14.Based on this information, I certify that (check one):
□The elevations and drainage patterns of the lot/site are in substantial conformance with the City
approved drainage and grading plan for the property (information attached).
□The elevations and drainage patterns of the lot/site as measured are in general conformance with the
City approved drainage plan with exceptions (information attached). In my professional judgment the
elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the
specifically approved drainage plan, and will affect stormwater drainage on and off the lot/site in a
manner consistent with the approved drainage plan.
Name:
Email:
Phone:
Company:
Address:
NOTE: A complete certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lot/site, including, but not limited to, drawings of the lot/site showing the approved design and as-built surveyed
elevations of all structures, drainage and grading features, written information/explanation of discrepancies, and other
information necessary to confirm the above certification to:
Email (preferred)
WaterUtilitiesEng@fcgov.com
Mailing Address
Fort Collins Utilities
ATTN: Water Utilities Engineering
281 North College Avenue
Fort Collins, CO 80521
Questions?
970-221-6700
PE Stamp
Sign and date
homeowner after purchase
4
Troy W. Campbell
troy@i2-consultants.com
970.217.9148
i2 Consultants, Inc.
16911 Potts Place
Mead, CO 80542
TC
TC
TC
TC
TC
07/27/2021
i2
Consultants, Inc.
16911 Potts Place, Mead, CO
970.217.9148 troy@i2-consultants.com
Exceptions to the Site
Grading Policies/Requirements
July 27, 2021
RE: 2151 Yearling Drive, Fort Collins, CO
Lot 3, Block 1, Bucking Horse Filing Three
(Building Permit No. B2100253)
EXCEPTIONS
The record survey indicates several elevations are outside of the 0.2’ tolerance:
· The top of foundation elevation is below the approved grading design;
· The finished grade around the house is below the approved grading design;
· Several points on the eastern property line are either above or below the
approved grading design;
· The southwestern property corner is below the approved grading design.
The lots to the west and east of the subject property have been developed and have
existing landscaping.
The grade away from the northwestern corner of the garage is less than 5%; the
minimum grade away from the garage is 1.0%.
A portion of the swale in the northwestern area of the lot is less than 1%. The swale is
0.5% and not near the structure.
The swale flowline elevation near the northwestern corner of the garage is less than 6”
below the adjacent finished grade of the garage.
The swale along the western property line (common lot line with Lot 2) is inside Lot 3.
Runoff from Lot 2 reaches the swale on Lot 3. The difference in elevations between the
properties and existing landscaping necessitated the contractor to construct the swale
inside Lot 3 and not on the property line.
2151 Yearling Drive
Fort Collins, CO
Lot 3, Block 1
Bucking Horse Filing Three
Sheet G1
Scale: 1"=40'
North