Loading...
HomeMy WebLinkAboutLot Certifications - 02/18/20212/14/17 Page 1 CERTIFICATION OF LOT GRADING Pursuant to Fort Collins City Code § 26-544 & City Land Use Code § 3.3.2 (e) Date: Address: Lot: Block: Subdivision: Permit Application #: Larimer County Parcel #: Larimer County Reception #: (on development agreement) I, (print) , a Colorado registered professional engineer, verify that construction of all stormwater facilities and grading is complete and hereby submit this certification. Please answer the following questions by initialing the appropriate response. For each question initialed “No,” attach an explanation detailing how this will affect stormwater drainage for this lot and any adjacent lots. 1.Certification includes attached Stormwater-approved grading plan. (NOTE: City’s Building Department does not approve grading plans). 2.Certification includes the attached as-built survey dated (must be within 60 days of the date the certification is submitted) accurately and truthfully depicting elevations for: Top of foundation/finished floor Finished grade on each side of the structure Quarter points along each lot line (not more than 50 feet apart) Break points/high points Swales Berms Retaining walls Air conditioning pads Window wells Any other appurtenance(s) within an easement 3.All elevations are within a 0.2 foot tolerance of the approved grading plan. 4.The top of foundation is at least 6 inches above the highest grade surrounding the structure. 5.There is a minimum grade of 5% away from the structure within the first 5 to 10 feet adjacent to the residence. 6.All slopes meet or exceed the minimum requirement of 2% (1% is acceptable on single family lots when the swale is draining the runoff from only two adjoining properties) and are not steeper than 33% (3:1). 7.All flow lines of stormwater drainage swales are a minimum of 6 inches below the elevation of ground adjacent to the structure and will direct drainage as shown on the Stormwater-approved grading plan. 8.All downspout locations and discharge directions are shown on the as-built survey. Runoff is directed into an appropriate drainage system or lot line swale, and it is not directed onto neighboring properties. No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes February 18, 2021 Bucking Horse Filing Three 2574 Nancy Gray B2010245 Fort Collins, CO 80525 8720368013 13 2 20140047537 Troy W. Campbell 02/17/2021 TC TC TC TC TC TC TC TC Homeowner after purchase i2 Consultants, Inc. 16911 Potts Place, Mead, CO 970.217.9148 troy@i2-consultants.com Exceptions to the Site Grading Policies/Requirements February 18, 2021 RE: 2574 Nancy Gray Ave, Fort Collins, CO Lot 13, Block 2, Bucking Horse Filing Three (Building Permit No. B2010245) EXCEPTIONS The record survey indicates the following elevations that are outside of the 0.2’ tolerance: · Western property line; · Eastern property line. There are existing residences to the east and west of this property. Also, the overlot grading for the lot varies from the approved development grading. The southeastern portion of the house has slopes away less than 5%. The slope away from the front porch has slopes away less than 5%. A short portion of the eastern property line is at a slope less than 1% (0.9% for roughly 15’ from the corner of the house to the southeastern property corner). The eastern property line matches existing grades and landscaping. A portion of the eastern lot line swale is less than 6” below the finished grade of the house. There is still positive drainage away from the house towards the swale. 2574 Nancy Gray Ave Fort Collins, CO Lot 13, Block 2 Bucking Horse Filing Three Sheet G2 Scale: 1"=40' North