HomeMy WebLinkAboutLot Certifications - 04/26/2018 (3)Accepted 4/26/2018 WL
EM
EM
GM
GM
EM
BLDG 5
4025 Automation Way, Suite C4
Fort Collins, CO 80525
970-232-9645
www.WashburnSurveying.com
Sheet 1 of 1 Project #: 2017-002 Date: April 13, 2018 Scale: 1"=10' Drawn: CDB
Scale: 1"=10'
AS-BUILT EXHIBIT
BUCKING HORSE APARTMENTS BUILDING 5
ELEVATIONS SHOWN ARE FROM AN AS-BUILT SURVEY OF THE SITE
PERFORMED ON MARCH 2 AND APRIL 11, 2018
TF
6.
2
%
1.0%
1.0%
2.
0
%
1.
5
%
4.
9
%
6.0
%
1.1%
5-
5
"
S
T
E
P
S
2.0%
91
.
4
5
89.8
2
90.3
4
90
.
0
1
90.0
6
89.7
9
89
.
5
7
89
.
6
2
90
.
5
6
91.52
90.23
90
.
4
1
90
.
5
7
90.
6
7
90.
6
6
90
.
8
7
91.0
3
FFE=91.45
90.7
6
90.75
90.29
90
.
0
4
90.
1
2
(9
1
.
6
4
)
(91.
9
5
)
(9
2
.
0
0
)
(9
2
.
2
6
)
(9
2
.
0
0
)
(9
2
.
2
5
)
(9
2
.
8
7
)
(9
2
.
0
0
)
(9
2
.
3
7
)
(9
2
.
6
4
)
(92.31
)
(9
2
.
5
5
)
(92.
1
7
)
(92.
4
4
)
(93.9
0
)
90.7
9
90.32
90.55
89.72
90.
2
5
91.0190.11
92.8
3
90.88
90
.
3
5
90.0
490.56
90.04
90.92
90.1
5
91.98
92.3
6
92
.
6
9
92.2
3
91.37
90.9
5
90.95
91.38
90.8
1
90.
4
0
89
.
6
4
89.9
089.8
5
89.59
89.5
3
89.7
9
89.7
9
89.2
7
90.1
2
90.37
90.02
AREA
D
R
A
I
N
AD
1
89.62
90.23
89.
9
7
NANCY GRAY AVEN
U
E
BL
D
G
5
FFE=91.45
90.92
90.95
90.95
90.89
90.47
90.
6
4
90.
8
9
90
.
5
4
90
.
2
8
90
.
1
3
90.9
5
90.9
5
90.1
8
90
.
1
4
90.6
6
90.5
5
89.78
89.91
90.5
6
91
.
1
0
EXTEND FOUNDATION
W
A
L
L
3.
2
%
3.
2
%
2.3
%
7.
9
%
6.
0
%
2.0%
2.
1
%
0.9
%
2.0
%
2.
1
%
2.0
%
2.2
%
2.6
%
91
.
3
2
91
.
7
5
91
.
9
3
(92.
6
3
)
93.35
92
.
6
9
92.5
4
90.4
5
14.9%
89.51
90.17
91.3
7
91.2
9 91
.
3
6
91.
3
6
91.17
91.2891.03
90.
8
0
91.3
6
91.28
91.37
2-
6
"
S
T
E
P
S
90.3
7
91.
3
6
90.9
5
23
.
1
%
29
.
8
%
3.
4
%
2.3
%
0.9%
1.1%
1.0%
1.0%1.1%
1.0
%
0.
2
%
10
.
2
%
2.2%
4.4%
5.0
%
6.4
%
18.5%
BUCKING HORSE
APARTMENTS
SHEET NO:
\\
B
R
O
N
C
O
S
\
E
N
G
I
N
E
E
R
S
\
P
R
O
J
E
C
T
S
\
6
8
7
-
0
0
4
\
D
W
G
\
R
E
C
O
R
D
D
R
A
W
I
N
G
S
\
B
U
I
L
D
I
N
G
C
E
R
T
S
\
6
8
7
-
0
0
4
_
G
R
A
D
_
A
B
.
D
W
G
DRAWING REFERENCE:
BUILDING 5 CERTIFICATION M. Kuehnel
1in=20ft
04-20-18 AB-05
DRAWN BY:
SCALE:
ISSUED:
( IN FEET )
0
1 INCH = 20 FEET
20 20
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
E N G I N E E R N GI
EHTRON R N
970.221.4158
northernengineering.com
LEGEND:
EXISTING STORM SEWER
DESIGNED STORM SEWER
DESIGNED STORM INLET
DESIGNED CONTOUR
DESIGNED SWALE
DESIGNED OUTFLOW
CURB AND GUTTER
DESIGNED SPOT ELEVATION
EXISTING SPOT ELEVATION
AS-BUILT SLOPES
AS-BUILT SPOT ELEVATION
AS-BUILT SWALE
DIRECTION OF DOWNSPOUT
TF
TFTF
XXXXXXXXXXXXXXXXX
CUTTING HORSE DRIVE
(PRIVATE DRIVE)
TRACT
A
STORM DRAIN C
SEE SHEET ST2 STORM DRAIN D
SEE SHEET ST3
N:17203.96
E:12871.22
EXISTING 2' CONCRETE PAN
EXISTING 15" RCP
FUTURE CURB &
GUTTER
EXISTING 42" RCP
1.
0
%
1.
0
%
6.6%
12.5%
2.0%
1.5%1.5%1.5%1.6%
1.
5
%
1.
5
%
1.6%1.2%1.8%
1.5%1.4%
1.5%
1.
3
%
1.5%
2.
0
%
3.
0
%
3.
6
%
2.
0
%
3.
5
%
3.
2
%
4.
8
%
4.
5
%
2.
0
%
91
.
4
5
91.7
2
91
.
6
2
91
.
5
2
91.58
91.8
8
91.18
91
.
0
6
91.1
2
91.4
5
90.3
4
90
.
0
1
90.0
6
89.7
9
89
.
5
7
89
.
3
8
89
.
4
1
89
.
8
9
89.9
0
90.6
4
90
.
7
0
90.
6
9
91.0
9
90.99
90.35
90
.
2
9
91.
5
3
91.43
90
.
7
9
90
.
7
3
90
.
7
5
91.08
92.02
91.13
91.1
9
90.49
90.3
9
90
.
5
0
90
.
2
2
90
.
0
0
89
.
8
2 89.
5
7
89
.
2
9
89
.
6
2
90
.
5
6
90.23
90
.
4
1
90
.
5
7
90.
6
790.
6
691.26
91
.
1
7
91
.
3
0
91
.
4
9
91
.
5
9
91
.
5
4
91.2
5
90
.
8
7
91.0
3
(91.
5
0
)
FFE=91.45
90
.
7
6
90.
7
5
90.29
90
.
0
4
90.
1
2
89
.
4
8
89
.
5
3
89
.
4
0
GARAGE
OPENINGS=89.73
90.00
(9
1
.
6
4
)
(91.
9
5
)
(9
2
.
0
0
)
(9
2
.
2
6
)
(92.31
)
(9
2
.
5
5
)
(92.
1
7
)
(9
1
.
4
1
)
(9
2
.
1
9
)
90.7
9
90.32
91.
4
5
91.48 90.55
88.
9
4
(86
.
8
0
)
(86.18)
90.
2
5
91.01
90.1190.87
90
.
8
4
91.
4
2
91.13
90
.
9
1
91.2992.08
92.21
91.
2
8
91.
3
5
91.69
91.
9
7
91.76
92
.
1
7
91.66
93.
4
4
92.8
8
92
.
6
7
92.80
93.24
91.79
92.20
90.
3
5
90
.
0
4
90.56
90.0
4
(85.28)(86.39)
90.
8
5
90.1
5
92.93
93.1
5
93.1
5
93.6
0
92.94
92
.
7
4
93.8
2
92.75
91.98
92.5
9
92.6
5
92.3
6
92
.
2
7
92.
1
8
92
.
5
9
92.5
9 92
.
4
7
92.59
92.19
91.37
90.9
5
90.9
5
91.3
8
90.8
1
90.
4
0
89
.
6
4
89.9
0
89.8
5
89.59
89.5
3
89.7
9
89.7
9
89.2
7
89.2
8 88
.
7
9
89
.
9
5
90.1
2
90.
3
7
90.02
91.
7
9
92.
3
2
91.
9
8
92.
8
5
92.
3
2
91.
9
9
91.
6
6
AREA DRAIN
SEE SHEET AD1
AREA DRAIN
SEE SHEET AD1
AREA DRAIN
SEE SHEET AD1
90.22
90
.
2
3
90
.
7
2
90
.
2
2
90.2
3
89
.
7
2
90
.
3
3
90.3
5
89
.
1
2
89
.
8
7
89.62
5' SIDEWALK
CHASE
5' CURB
CUT
90.23
92.08
AREA DRAIN
SEE SHEET AD1
89.97
NA
N
C
Y
G
R
A
Y
A
V
E
N
U
E
BLDG 3
FFE=93.82 FFE=93.82 FFE=93.82
BLDG 4
FFE=93.26 FFE=93.26 FFE=93.26 FFE=93.26
BLDG 5
FFE=91.45
90.92
90.95
90.95
90.89
90.47
90.
6
4
90.
8
9
90
.
5
4
90
.
2
8
90
.
1
3
90.9
5
90.9
5
90.1
8 90
.
1
490.6
6
91.1
9
88
.
4
9
89.56
88
.
4
3
86
.
1
7
(85.54)
90.5
5
89
.
7
8
89
.
9
1
91.10
EXTEND FOUNDATION WALL
MIN. 6" ABOVE FG
EXTEND FOUNDATION WALL
MIN. 6" ABOVE FG
EXTEND FOUNDATION WALL
MIN. 6" ABOVE FG
EX
T
E
N
D
F
O
U
N
D
A
T
I
O
N
W
A
L
L
6"
A
B
O
V
E
F
F
E
1-6" STEP 2-6" STEPS
2-6" STEPS 92.8
8
91.4
7
93.8
2
93.82
93
.
2
6
93
.
2
6
93
.
2
6
93
.
2
6
90.
0
5
89.
8
5
89.
9
5
89.
7
2
4.
3
%
7.
5
%
5.
3
%
6.
1
%
8.
4
%
5.
8
%
2.
0
%
2.3
%
4.7%
PROPOSED
INTERIM TRAIL
RIPRAP CHANNEL
(TYPE M RIPRAP
±30' LONG x 8' WIDE)
GARAGE
OPENINGS=90.22
GARAGE
OPENINGS=90.72
GA
R
A
G
E
OP
E
N
I
N
G
S
=
8
9
.
6
2
3.2%3.2%
90
.
0
3
89.49 88.99
0.5%0.5%0.5%
2.
1
%
2.
1
%
2.
1
%
2.
1
%
2.3%2.
1
%
2.
1
%
7.9%
6.0%
14
.
5
%
10
.
3
%
8.
9
%
7.
8
%
7.5%
5.2%
13
.
3
%
7.
4
%
9.
6
%
8.3
%
6.
7
%
8.
0
%
9.
5
%
2.
1
%
2.0
%
2.1%
0.9%
2.0%
2.1%
2.0%
2.2%
2.6%
2.
1
%
2.1
%
2.1
%
2.
1
%
91
.
3
2
91
.
7
5
91
.
9
3
(92.
6
3
)
89.51
90.17
90.
5
9
91.3
7
91.2
9
91.3
6
91.3
6
91.1
7
91.
2
890.80
91.3
6
91.
2
8
91.37
2-6" STEPS
90.3
7
91.
3
6
90.9
5
5.9%
24.9%
6.3%
23.1%
29.8%
2.8%
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
G3
GR
A
D
I
N
G
P
L
A
N
Sheet
Of 39 Sheets
DR
A
W
I
N
G
F
I
L
E
N
A
M
E
:
D
:
\
P
r
o
j
e
c
t
s
\
6
8
7
-
0
0
4
\
D
w
g
\
G
r
a
d
\
6
8
7
-
0
0
4
_
G
R
A
D
.
d
w
g
L
A
Y
O
U
T
N
A
M
E
:
G
3
D
A
T
E
:
M
a
r
3
1
,
2
0
1
7
-
1
:
0
4
p
m
C
A
D
O
P
E
R
A
T
O
R
:
a
n
d
y
LI
S
T
O
F
X
R
E
F
S
:
[
6
8
7
-
0
0
4
_
x
U
T
I
L
]
[
6
8
7
-
0
0
4
_
x
E
X
S
T
]
[
6
8
7
-
0
0
4
_
x
G
R
A
D
]
[
6
8
7
-
0
0
4
_
x
S
I
T
E
]
[
6
8
7
-
0
0
4
_
x
T
O
P
O
]
[
N
E
S
-
x
b
o
r
d
e
r
]
[
6
8
7
-
0
0
4
_
K
E
Y
M
A
P
]
[
6
8
7
-
0
0
4
_
x
A
D
J
]
[
6
8
7
-
0
0
4
_
3
D
_
P
r
o
p
o
s
e
d
]
[
6
8
7
-
0
0
4
_
x
G
R
A
D
_
l
e
g
]
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
Ph
o
n
e
:
9
7
0
.
2
2
1
.
4
1
5
8
-
F
i
l
i
n
g
F
o
u
r
9.30.16
KEYMAP
LEGEND:
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED OUTFLOW CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5.CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7.TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE
PROPOSED OUTSIDE THE LIMITS SHOWN.
8.SEE SHEETS CS1 AND CS2 FOR PROJECT BENCHMARKS AND VERTICAL DATUM.
ADD 4800-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS,
WHERE TRUNCATED; EXCEPT IN WESTERN AREA OF SITE, WHERE ACTUAL
ELEVATIONS RANGE FROM 4900-FT TO 4910-FT.
NOTES:
PROPOSED STORM INLET
PEDESTRIAN ACCESS RAMPS
EXISTING SPOT ELEVATION
PROPOSED FIRE HYDRANT
PROPOSED ELECTRIC TRANSFORMER
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
EXISTING RIGHT OF WAY
PROPOSED INFLOW CURB AND GUTTER
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
2
MATCHLINE - SEE SHEET G6
G1
G2G4
G3G5
G6
G7
G8
G9
2
SI
T
E
P
L
A
N
U
P
D
A
T
E
S
AG
R
3/
2
9
/
3
0
2
REVISION #2 KEY
1 REVISED CURB LOCATION AND ELEVATIONS
2 REVISED GARAGE FOOTPRINT
3 ADDED MAIL KIOSK/RELOCATED BIKE RACKS
4 REVISED CLUBHOUSE FOOTPRINT AND FLATWORK
5 REVISED 'C' BUILDING FOOTPRINT AND FLATWORK
111
1
2
5
UD UD
UD
TF
TF
TF
TF
6.5%
6.2%
NA
N
C
Y
G
R
A
Y
A
V
E
N
U
E
CUTTING HORSE DRIVE
(PRIVATE DRIVE)
MILES HOUSE AVENUE
(PRIVATE DRIVE)
YE
A
R
L
I
N
G
R
O
A
D
(P
R
I
V
A
T
E
D
R
I
V
E
)
YE
A
R
L
I
N
G
R
O
A
D
(P
R
I
V
A
T
E
D
R
I
V
E
)
N:16814.86
E:12564.55
N:16899.16
E:12481.75
3.0%
1.
0
%
2.0%1.6%1.2%1.8%
4.9%
6.0%
1.1
%
1.5
%
1.5%
6.7%0.8
%
3.3
%
1.5%
1.5%1.5%
5-5" STEPS2.
0
%
2.
0
%
2.
0
%
1.
0
%
4.
5
%
3.
5
%
3.2%
89.8
290
.
4
7
90.85
91
.
3
9
91.44
91.53
91.6
2
91.
7
9
91
.
2
5
92.16
93
.
8
3
92.6
9
93.02
90.8
2
90
.
7
8
90
.
8
0
91.0
0
93.02
93.39
91.
9
8
91.5
6
91.4
5
91.03
92
.
0
7
92.75
91.62
91.52
90.23
90
.
4
1
90
.
5
7
90.
6
790.
6
691.26
91
.
1
7
91
.
3
0
91
.
4
9
91
.
5
9
91
.
5
4
91.6
7
91
.
5
7
91
.
0
7
91.26
91.2
5
(92.5
3
)
(92
.
4
6
)
(92.89)
(92
.
3
7
)
CLUBHOUSE
FFE=92.47
91.2
2
92.
0
0
91.88
91.
7
3
91
.
7
4
91.
8
4
92.
1
1
91.8
0
91.60
90
.
7
6
94.27
94.88
91.84
92
.
5
8
93
.
1
4
92.47
93.83
92
.
5
5
92.75
92
.
9
6
(92
.
1
3
)
(92
.
1
3
)
(92
.
5
6
)
(92
.
4
7
)
(92.27)91.76
92.38
91
.
1
2
92.1
0
91.56
91
.
7
5
(92.6
8
)
(93.
1
3
)
(93.9
0
)
(9
3
.
4
6
)
(93
.
4
5
)
(9
3
.
0
8
)
(93
.
0
8
)
91.
1
8
91.2
3
90
.
8
9
90.6
8
90.5
6
90.32
89.72
91
.
1
8
91
.
0
6
90
.
8
8
91
.
5
0
91.
0
9
91.5
6
91.
1
2
90.1190.87
90
.
8
4
91.
4
2
91.13
90
.
9
1
91.2992.08
91.76
92
.
1
7
91.66
93.
4
4
92.68
92.97
92.8
3
92.84
94.26
90.9
5
90.5
0
90.5
4
91.3
3
90.7
1
92.
8
9
90.88
91.84
94.28
92.0
1
90.0
4
90.92
92.93
91.9892.19
92.6
9
92
.
6
9
92.2
3
91.4
7
92.6
9
92.8
5
92.6
9
92.6592.65
92.11
92.69
92.54
94.19
94.08
93.96
93.96
93.98
92.32
91.81
91.8191.81
91
.
9
7
92
.
2
7
93.
9
4
93.5
1
94.51
94.
5
1
94.58
94
.
9
4
93.51
93.51
93.78
94.0
1
95.
2
6
94.
8
3
94.
8
3
91.37
90.9
5
90.
3
7
90.02
91.
7
9
92.
3
2
91.
9
8
91.62
91.8
7
91.65
91
.
2
9
91.3
4
91
.
7
4
91.7
5
91.
7
6
91.1
4
(92
.
0
0
)
(91
.
8
6
)
91
.
1
4
91.
2
9
91.
3
4
91
.
7
4
91
.
6
8
91
.
7
6
91.11
91.0
8
90.8
2
(92.
6
9
)
92
.
1
5
92
.
1
7
92
.
1
0
92.04
92.8
7
92.58
92.75
92
.
3
6
92.23
92.32
92.41
91.84
92.1
3
93.
8
4
90.
8
8
90.
8
5
91.87
91.
8
0
91.86
90.8
6
91.8
8
90
.
8
7
91.8
9
93.00
90
.
3
2
90
.
8
1
90
.
8
0
90
.
3
1
90.
3
090.
8
1
90.8
0
90
.
3
1
93.
6
5
RAIN GARDEN E
SEE SHEET RG1
RAIN GARDEN B
SEE SHEET RG1
AREA DRAIN
SEE SHEET AD1
AREA DRAIN
SEE SHEET AD1
AREA DRAIN
SEE SHEET AD2
93.
4
7
92.
6
5
92.
1
5
AREA DRAIN
SEE SHEET AD1
91
.
6
7
92
.
2
0
92
.
1
0
91
.
6
5
92.79
90.23
91.
8
0 91.2
3 90.9
2
91.28
90
.
8
2
5' SIDEWALK
CULVERT
91.50
91.34
91.4
6
5' SIDEWALK
CULVERT
92
.
2
0
5' SIDEWALK
CHASE
92.8
1
92.5
4
92.
5
8
89.97
BLDG 16
FFE=95.01
FFE=94.01
BLDG 10
FFE=93.35 FFE=93.35
FFE=91.45
93
.
5
0
93.
9
3
94.
0
1
93.
5
1
93.
4
3
94
.
9
2
94
.
9
2
94
.
9
3
94
.
8
4
92
.
9
3
2-6" STEPS
90.89
90.47
90.5
6
91.10
93.92
93.
9
2
91.45
5:1
8.9%
2.9%
9.6%
7.9%
5.5%
4-6" STEPS
91.4
7
14
.
5
%
8.
9
%
7.
8
%
8.
0
%
9.
5
%
13.9%
8.
4
%
8.
1
%
11
.
1
%
6.6
%
2.2%
2.3%
2.5%
7.6
%
4.3%
2.1%
2.2%2.2%
2.3%
2.1%
2.2%
2.1%
2.1%
2.1%
2.1
%
2.1
%
3.
0
%
2.
2
%
2.1
%
2.0
%
0.9%
93.35
93.35
93.35
93.35
92.8
5
92.8
5
92.
6
9
92.
5
3
92.
7
8
92.
6
8
92.08
91.
3
1
92.69
91.51
92
.
6
9
92.5
4
90.4
5
91.8
7
92.6
9 92.6
9
1.
0
%
5.8%
4.0%
15
.
3
%
5.
2
%
5.
4
%
6.
2
%
6.4%
14
.
8
%
11
.
2
%
14
.
9
%
92.5
6
93.93
94.40
91.3
7
91.2
9
91.3
6
91.3
6
91.1
7
91.
2
8
91.03
90.80
29.8%
28
.
9
%
4.3%
2.8%
91
.
3
1
91.
8
1
91
.
9
3
90.90
91.0
1
91.5
4
92
.
4
7
91.
9
3
92.08
92.08 91.99
92.01
92.
4
7
92.
3
6
92.2
0
91.
8
6
91.3
1
91.3
191
.
2
5
91.13
10.6
%
92
.
7
7
92.90
92.98
92.9
1
93.00
93.0514.
3
%
1' SIDEWALK
CHASE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
G6
GR
A
D
I
N
G
P
L
A
N
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G
5
MATCHLINE - SEE SHEET G3
Sheet
Of 39 Sheets
DR
A
W
I
N
G
F
I
L
E
N
A
M
E
:
D
:
\
P
r
o
j
e
c
t
s
\
6
8
7
-
0
0
4
\
D
w
g
\
G
r
a
d
\
6
8
7
-
0
0
4
_
G
R
A
D
.
d
w
g
L
A
Y
O
U
T
N
A
M
E
:
G
6
D
A
T
E
:
M
a
r
3
1
,
2
0
1
7
-
1
:
0
4
p
m
C
A
D
O
P
E
R
A
T
O
R
:
a
n
d
y
LI
S
T
O
F
X
R
E
F
S
:
[
6
8
7
-
0
0
4
_
x
U
T
I
L
]
[
6
8
7
-
0
0
4
_
x
E
X
S
T
]
[
6
8
7
-
0
0
4
_
x
G
R
A
D
]
[
6
8
7
-
0
0
4
_
x
S
I
T
E
]
[
6
8
7
-
0
0
4
_
x
T
O
P
O
]
[
N
E
S
-
x
b
o
r
d
e
r
]
[
6
8
7
-
0
0
4
_
K
E
Y
M
A
P
]
[
6
8
7
-
0
0
4
_
x
A
D
J
]
[
6
8
7
-
0
0
4
_
3
D
_
P
r
o
p
o
s
e
d
]
[
6
8
7
-
0
0
4
_
x
G
R
A
D
_
l
e
g
]
E
N
G
I
N
E
E
R
N
G
I
E
H
T
R
O
N
R
N
30
1
N
o
r
t
h
H
o
w
e
s
S
t
r
e
e
t
,
S
u
i
t
e
1
0
0
Fo
r
t
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
8
0
5
2
1
ww
w
.
n
o
r
t
h
e
r
n
e
n
g
i
n
e
e
r
i
n
g
.
c
o
m
Ph
o
n
e
:
9
7
0
.
2
2
1
.
4
1
5
8
-
F
i
l
i
n
g
F
o
u
r
9.30.16
KEYMAP
G1
G2G4
G3
LEGEND:
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED OUTFLOW CURB AND GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
4.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5.CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6.ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NGVD 29
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7.TRACT A IS BEYOND THE LIMITS OF THESE PLANS. NO IMPROVEMENTS ARE
PROPOSED OUTSIDE THE LIMITS SHOWN.
8.SEE SHEETS CS1 AND CS2 FOR PROJECT BENCHMARKS AND VERTICAL DATUM.
ADD 4800-FT TO PROPOSED CONTOURS, SPOT ELEVATIONS, AND FFE LABELS,
WHERE TRUNCATED; EXCEPT IN WESTERN AREA OF SITE, WHERE ACTUAL
ELEVATIONS RANGE FROM 4900-FT TO 4910-FT.
NOTES:
PROPOSED STORM INLET
PEDESTRIAN ACCESS RAMPS
EXISTING SPOT ELEVATION
PROPOSED FIRE HYDRANT
PROPOSED ELECTRIC TRANSFORMER
PROPOSED LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
EXISTING RIGHT OF WAY
PROPOSED INFLOW CURB AND GUTTER
MATCHLINE - SEE SHEET G9
G5
G6
G7
G8
G9
2
SI
T
E
P
L
A
N
U
P
D
A
T
E
S
AG
R
3/
2
9
/
3
0
2
REVISION #2 KEY
1 REVISED CURB LOCATION AND ELEVATIONS
2 REVISED GARAGE FOOTPRINT
3 ADDED MAIL KIOSK/RELOCATED BIKE RACKS
4 REVISED CLUBHOUSE FOOTPRINT AND FLATWORK
5 REVISED 'C' BUILDING FOOTPRINT AND FLATWORK
4
3
1
2
5