Loading...
HomeMy WebLinkAboutGrading Plans - 08/28/2024X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXX X X X X 8' - 5" GATE GATE FENCE PARKING EXISTING GARAGE EXISTING RESIDENCE PORCH ALLEY ELIZABETH STREET SIDEWALK PROPOSED ADDITION PORTION OF EXISTING RESIDENCE TO BE DEMOLISHED WALL OF NEW ADDITION STEP BACK 12" FROM EXISTING WALL 12" DO W N DO W N SIDE ENTRY FRONT ENTRY REAR ENTRY EXISTING TREE PATIO 5' - 4" WALL OF NEW ADDITION STEP BACK FROM EXISTING WALL 29' - 0" 20 ' - 0 " W I N D O W W E L L W I N D O W W E L L W I N D O W W E L L PORTION OF EXISTING RESIDENCE TO BE DEMOLISHED = 152 sq ft W I N D O W W E L L RAISED GARDEN BED RAISED GARDEN BED DO W N 5' - 8" SE T B A C K 15 ' - 0 " SETBACK 5' - 0" SETBACK 5' - 0" 60 ' - 8 " SE T B A C K 5' - 0 " DN SE W E R L I N E WA T E R L I N E EL E C T R I C L I N E ELECTRIC METER OPTION #2 ADD ALTERNATE: REPLACE EXISTING PARKING PAD w/ NEW CONCRETE PAD GA S L I N E ABANDON EXISTING GAS LINE DS DS DS DS (E) DS (E) DS (EXACT SIZE/SHAPE/MATERIAL TBD BY LANDSCAPE DESIGN) ELECTRIC METER OPTION #1 EXISTING ELECTRICAL SERVICE C O D E D A T A Address: Site Area: Occupancy Classification: Construction Type: Number of Stories:2 + BASEMENT TYPE R-3 V-B 425 EAST ELIZABETH, FORT COLLINS, CO 80524 7000 SF 2021 I.R.C. w/ LOCAL AMMENDMENTS 2021 I.F.C. w/ LOCAL AMMENDMENTS 2021 I.E.C.C. w/ LOCAL AMMENDMENTS ROOF MIN R-60 WALLS MIN R-30 CAVITY (OR R-20 CAVITY + R-5 C.I.) BASEMENT WALLS MIN R-15 CONT. OR MIN. R-19 CAVITY WINDOW U-FACTOR MAX .28 0.25 MAX. U-VALUE ON ELEVATIONS WITH 30% GLAZING OR MORE Codes: Zone District:NCM -NEIGHBORHOOD CONSERVATION, MEDIUM DENSITY DISTRICT 983 sf 959 sf + 575 sf = 2517 sf Residence Main Level (to remain) Residence Upper Level (to remain) Garage (to remain) TOTAL EXISTING FLOOR AREA TO REMAIN 2517 sf + 580 sf = 3097 sf Total Existing Floor Area to Remain Proposed New Floor Area TOTAL PROPOSED FLOOR AREA: Max Allowable Floor Area (overall) = 7000 sf x .25 + 1000 sf = 2750 sf -250 sf detached accessory structure = 2847 sf = 3.5% greater than Max Allowable Floor Area Max Allowable Floor Area (on the rear half of the lot) = 3500 sf x .33 = 1155 sf 575 sf + 271 sf = 846 sf Garage Proposed New Floor Arear on the rear half TOTAL FLOOR AREA ON THE REAR HALF: 419 Canyon Ave Suite 200, Fort Collins, Colorado 80521 970.224.1191 | www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. CHECKED BY: DRAWN BY: COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE REVISIONS No.Description Date VAUGHT FRYE LARSON ARONSON TM TM NOT FOR CONSTRUCTION FOR REFERENCE ONLY A R C H I T E C T U R E + I N T E R I O R S PEN ENGINEERING, LLC (720) 347-0054 wthompson@pen-engineeringllc.com www.pen-engineeringllc.com CONTACT: WAYNE THOMPSON 7/ 5 / 2 0 2 4 1 : 1 4 : 0 2 P M 7/5/2024 1:14:02 PM C: \ U s e r s \ t a y l o r \ D o c u m e n t s \ O c e a n a k R e s i d e n c e _ t a y l o r 9 U2 C 7 . r v t A0.1 SITE PLAN OCEANAK RESIDENCE REMODEL & ADDITION 425 EAST ELIZABETH FORT COLLINS, CO 80524 CONSTRUCTION SET 07-05-2024 2023-21 1" = 10'-0"1 ARCHITECTURAL SITE PLAN 2 ABOVE SOUTHWEST 5 3 SOUTHEAST 5 4 SOUTHWEST 5 EAST ELEVATION SOUTH ELEVATION WEST ELEVATION PROJECT NORTH CHANGE IN IMPERVIOUS SURFACE AREA CHANGE IN IMPERVIOUS SURFACE AREA PORTION OF EXISTING RESIDENCE TO BE DEMOLISHED-152 sq ft = 580 sq ft = 428 sq ft = PROPOSED NEW FLOOR AREA 07-05-2024 DS = DOWNSPOUT, TYP. 425 East Elizabeth Street Building Permit B2405589 Crafts Resub W 20 FT OF LOT 3 & E 30 FT OF LOT 4, BLK 3 Grading/Stormwater Plan Accepted (Building Permit Released) Accepted by: Date : Dan Mogen 08/28/2024