CERTIFICATION OF LOT GRADING
Pursuant to City Code 26 6-544 and City Land Use Code 6 3.2.2 (e)
Date: June 5 2014 11 t,
Permit Application No. BP1306114 ISOr�" s �r / /t t
Address: 5721 C000ervein Street t�W
Lot. 4 Block: 2
Subdivision: Kechter Crossing Planned Land Division
(,(Print) Steven M. Stricklina , a Colorado registered professional engineer, verify that the above
referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified
professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete,
and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey
performed on (Date): June 2 2014 _. accurately and truly depict the elevations and drainage patterns as
they existed on the date of the survey. Based on this information, I certify that (check one):
The elevations and drainage patterns of the IoUsite are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
'tL The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved
drainage plan, and will affect stormwater drainage c
approved drainage plan. SEE NOTE.
By.
10056 Brisbane Lane Littleton_ CO 80130
(address of signing party)
with the
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the IoUsite, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed
elevations of all structuresdrainage and grading features (e.g. swales, retaining walls, lot comers), written
informationlexplanation of discrepancies, and other information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood street
Fort Collins, CO 80521
(970)221-6700
Rev 1127%12 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
CIVAS
June 5, 2014 engineering
FORT COLLINS UTILITIES
700 Wood Street
Fort Collins, Colorado 80521
Re: Lot 4, Block 2, Kechter Crossing Planned Land Division
Certification of Lot Grading
The elevations and drainage patterns for Lot 4, Block 2, Kechter Crossing Planned Land Division
are in general conformance with the City approved Final Grading Plan for Kechter Crossing Planned
Land Division, with one minor exception. The high point locations in the rear yard are approximately
10 feet from the rear property line instead of on the rear property line as shown on the Final Grading
Plan. This is because the rear property line elevations are approximately 0.7 feet to 0.8 feet lower
than those shown on the Final Grading Plan, due to the elevations of the concrete pan in Outlot B,
constructed as part of the subdivision drainage infrastructure improvements. Since Lot 4, Block 2 is a Type A draining lot, the high point elevations were located approximately 10 feet in from the rear
property line in order to provide the minimum 2% slope in the side yard swales draining to the front
yard. It is our professional opinion that this exception is not significant and will still allow for
stormwater drainage to be consistent with the City approved Final Grading Plan,
Sincerely,
CIVAS Engineering, LLC.
Steven N
Principal
10056 Brisbane Lane - Littleton -CC •80130
tel 720-240-5882 fax 720-223-6092
O
O
R Z I TF=4946.50 I '
9 I `. 4 PAD=4945.39
j
Too f
I� B2—L3 �.
M
AAT
TF=4947.20
PAD=4945.40
I� SA I
B2—L4
A
TF=4947.40 a
r1 `�1 PAD=4945.94 .4 1
`JJ .J � I y�
B2—L5
A ai c
TF=4947.60 rn I, jI
PAD=4946.69 _
Z
c
I B2—L6
jar A I t
TF=4947.91 I
PAD=4947.41 I. I
LOWNWH1RM�;
IQSurveyin; Inc.
W
6841 SOUTH YOSEMITE STREET X700
CENTENNIAL, CO 80112
4 CONCRETE PAN
80g,85'
V.E.
5LLE
CON5IRUCT BERM 46.0.0
w 5J
V $
N O
<
1
xl
Y E`1
N
6I
45.
f5.3
w! N
45.3
4
k „1
=, i
1
5f
�l.
18.T60SQFtf
f 4
1 {
Ir
I sao
..6'Tx
Iyr
5.9
5.9'
B 45.
45.2
46.4
4 A 6.1
4.1
T
5
3
(ORNNAGE CERTIRCATION
PASSEO ON 02_20-2014,)
46.9
#5721
(DRNNAGE CERTIFICATION
5.9F
PASSED ON OB-C2-2014.)
'6
TOF=4947.260
GUTUNE OF
nl ni wnr.
6.2.
PROPOSED DOUSE
COV'D
Ma PORCH
P
EyW CONC. DRIVE Ip
39_S
1 1.0 L-41..g2l
45A" X44.7E
B.M. 68.00' 4.S WALK
5.6' TREE/LAWN
COPPERVEIN STREET
53' R.O.W.
0 20 4D
I"
EACK OF CURB
uNE
LOT 4. BLOCK 2, KECHTER CROSSING PUNNED LAND DIVISION, COUNTY OF ARIMER. STATE OF COLORADO:
ALSO KNOWN AS:5721 COPPER VEIN STREET.
ELEVATION AND DRAINAGE CERTIFICATE
I HEREBY CERTIFY THAT THE GRADING AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY
OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF,
ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE
MEASURED TO THE NEAREST 0.1 FEET. THERE IS SUBSTANTIAL POSITIVE SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND
THE GRADING AND DRAINAGE PATTERNS SUBSTANTIALLY MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN, DATED
11-19-13 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE
OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRAINAGE
DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS. LANDSCAPING OR OTHER IMPROVEMENTS. THEREFORE THIS
SURVEY MAY NOT ACCURATELY DEPICT THE GRADING AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY.
THIS ooaMENr 6 NOT AN IMPRw6MENT LwnaN CERTIruArt OR u D fiumEY PUT
THIS ABOVE STATEMENT WES NOT WRIT THIS PROPERTY TO BE FREE FROM INSINCE5 OF STIHOMG OR SLOW ORAPIM WATER AYY FROM THE FOUNWON.