HomeMy WebLinkAboutLot Certifications - 03/13/2014 (2)utilities
t
electric. stormwater- wastewater. water
CI}" 01
or Wood St
PO Box 580
Fort
Collins
F
Fort Collins. CO 80522
970.221,6700
970 221 6619 fax . 970.224.6003 TDD
utilitiesCa)fcgoy.com . fcgovcom/utllirles
CERTIFICATION OF LOT GRADING
Pursuant to City Code 26 6.544 and City Land Use Code § 3.2.2 (e)
Date. March 10 2014 rJtow, ct Yrcll4
Permit Application No 61301899
Address. 5740 Coopervem Street
Lot: 4 Block 6
Subdivision Kechter Crossing Planned Land Division
l,(Print) Steven M. Stricklin0 a Colorado registered professional engineer, verify that the above
referenced property in the City of Fort Collins. Colorado, has been inspected by me or an appropriately qualified
professional under my direct supervision, and verify that construction of all stormwater facilities and grading is
complete. and that the elevations and drainage patterns shown on the attached drawing(s) which were developed
from a survey performed on (Date). February 27 2014 accurately and truly depict the elevations and drainage
patterns as they existed on the date of the survey. Based on this information, I certify that (check one):
ns
7 The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved
drainage and grading plan for the property (information attached). SEE NOTE.
The elevations and drainage patterns of the lot/site as measured are in general conformance with the City
approved drainage plan with exceptions (information attached). In my professional judgment the elevations
and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically
approved drainage plan. and will affect stormwater drainage on and off the IoUsite in a manner consistent
with the approved drainage plan. SEE NOTE.
By:
10056 Brisbane Lane, Littleton, CO 80130
(address of signing party)
NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy
for the lotisite, including but not limited to drawings of the lot/site showing the approved design and as -built surveyed
elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot corners), written
informationlexplanation of discrepancies, and other information necessary to confirm the above certification to:
Fort Collins Utilities
700 Wood Street
For, Collins, CO 80521
(9701 221-6700
Rev 1P27772 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property
iI I TF-4946.90
I PAD=4945.8
1
B6-L3
B
(, TF=4946.70 d
PAD=4946.54
Ii
B6-L4
B
j I1 =0 I
I { i I , PAD-4947.4947.2
L_ i J
imp COI
�R.m - -
B2-L9
A
TF=4949.12 r
P AD= 4948.62
R CREST LANE
• I
-•--4946' - � i
i-
I ,I
B2-L10
TF=4948.87
PAD=4948.37
1 i
ELEVATION AND DRAINAGE CERTIFICATE
ying, Inc.
N0. 14—KCP-4-6
-Surve
6841 SOUTH YOSEMITE STREET 1100
CENTENNIAL, CO 80112
CONN011 MUD 1
1 .3 7T.90' 45:4 15.2
n� �o� 8. SFr 01—
rn� ab
1rx145J N .5.6 46.4x x46.4 46.3XIBE
3 al 45.20 5' gl1IS' r1 z!
4 .B 0.4 I n
M U.4 I In
PROPOSED ORurvAGE 45.7
u�O
2" #5740 I a M
OUTLINE of TOF=4948.23
EXISTING HOUSE I al
ID I II U
6.)
1]3 16{ �Cpp
6.)I 46 TORCH
S` CONC- DRIVE N.K 7 I tas
1 4i5 +7-6 4 l
45,7
15' M.E.
S '19'34"E 457 sb
aB.M, SB.SD 4.5' w0.N
5'a. TTR /
TOP &1K OF CURB
FLOW-
COPPERVEIN STREET
53' R.O.W. ""I rj 116"
-
P '
N_��rEti� PROt 0 SLI F-QOR
0 20 40 E w1A...•%.'L
SCALE: 1'=20' PREPARED FOR: MERITAGE HOMES DA • 11
LOT 4, BLOCK 6. KECHTER CROSSING PLANNED LAND DMSION, COUNTY OF LARIMER, STATE OF COLORADO:
ALSO KNOWN AS:5740 COPPERVEM STREET,
ELEVATION AND DRAINAGE CERTIFICATE
i HEREBY CERTIFY THAT THE GRADING AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY
OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF,
ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE
MEASURED TO THE NEAREST 0.1 FEET. THERE IS SUBSTANTIAL POSITIVE SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND
THE GRADING AND DRAINAGE PATTERNS SUBSTANTIALLY MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN, DATED
03-24-13 THE- ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEQUENT TO THE DATE HEREON DUE TO SUBSIDENCE
OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRAINAGE
DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS, LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS
SURVEY MAY NOT ACCURATELY DEPICT THE GRADING AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY.
TNIS WCWENT IS NOT AN IMPROIEMENT LOCATION CERHF1CATE OR UND SURVEY PLAT,
THE ABME STATDAENT DOES NOT WARRANT THK PROPERTY TO BE FREE FROM INSTANCES OF STANDING OR SLOW DMNING WATER PWAY FROM THE FWNOATON.
Daniel Mogen
From:
Daniel Mogen
Sent:
Thursday, March 13, 2014 10:28 AM
To:
6Hazen@bjsurvey.net
Cc:
Jon.Tschetter@meritagehomes.com
Subject:
5740 Coppervein Street
Attachments:
photo 1.JPG; photo 2.JPG; photo 1.JPG; photo 2.JPG
The site inspection has been completed, and the SW Eng Final hold has now been released. We are accepting the
engineer stamp as evidence that the lot is in conformance with the approved plan; however, in the inspection, I did have
some concerns that are documented in the attached photos.
- The swale on the north side of the property appears to have been graded properly; however, traffic through the
back of lot has left ruts disrupting the intended drainage.
These concerns/photos are documented with the grading certification, which is public record. A remedy to these
concerns is not required to release the hold at this time; however, if you would like to provide documentation showing
any changes, I will add that to the certification.
Please share this information with the engineer of record.
Please let me know if there are any questions.
Thanks,
Dan
Dan Mogen, El
Engineering Technician
City of Fort Collins Utilities
700 Wood Street
Fort Collins, CO 80522
(970)224-6192
dmoeenCcDfcQov.com
Fort Collins
U1iL4,es
i
♦Wad--. .. _ `1` � � �:�•�