HomeMy WebLinkAboutLot Certifications - 09/10/2013 (6)Utilities City of ~~~~ij~~~ -'Fort Collins SEP 092013 electric • stormwater • wastewater • water 700Wood St. PO Box 580 Fort Collins , CO 80522 970,221 .6700 ~!!!!~-----............________ 970 .221 .6619 fax • 970.224 .6003 TDD utilities@fcgov.com • fcgov.com/utilities CERTIFICATION OF LOT GRADING Pursuant to City Code§ 26-544 and City Land Use Code§ 3.2.2 (e) Date : September 5, 2013 ,, Permit Application No . ~uoito1.7 Address : 616 Peterson Street Lot: North ½ of lot 9 Subdivision : City of Fort Collins Block :_1~5'-"6 _____ _ 1,(Print) Kevin E . Forbes _____________ , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins , Colorado , has been inspected by me or an appropriately qualified professional under my direct supervision , and verify that construction of all stormwater facilities and grading is complete , and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): July 24, 2013 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey . Based on this information , I certify that (check one): X The elevations and drainage patterns of the loUsite are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE . □ The elevations and drainage patterns of the loUsite as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the loUsite as constructed are functionally adequate and equivalent to the specifically approved drainage plan , and will affect stormwater drainage on and off the loUsite in a manner consistent with the approved drainage plan . . . ..~ ~•o.f .'.S:. 3 ••• NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Ce i , a o ~ u for the lot/site, including but not limited to drawings of the lot/site showing the approved design and as uilt surveye elevations of all structures, drainage and grading features (e,g , swales, retaining walls, lot corners), written information/explanation of discrepancies, and other information necessary to confirm the above certification to : Rev. 1/27/12 Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970) 221-6700 At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property ''AS-BUILT" GRADING ~~~~'lB~~RTH 1/2 OF LOT 9, BLOCK 156, CITY OF FORT COLLINS SEP O g 2013 616 PETERSON , STREET, FORT COLLINS, COLORADO , .. soo•tB'OO''W so oo· . --===;7l-------:; I ., h' 0., 0., SCALE: 1" = 30 1 . -\- I wood I framed garage ~ ---n· ~ Oj ·c,, -l \ / ~ . ~ - !:&J ~'!' :: ~ J: co r,+ !'-4 ~ U) wood 0, deck 0, "-.i ~ --Oj .5 hp 96 C) lri j "' l j two story ..... frame house with _.._ basement -~ 96 . .J hp ff=100.0 covered ... porch lo" Oj .. ~ 10 j 0, U\ ~ ~ 1- Peterson Street prepared by Stewart &: Associates