HomeMy WebLinkAboutLot Certifications - 07/13/2023
KEEFE CIVIL, INC
3125 Crockett Street
Fort Collins, Colorado 80526
(970) 215-6808
July 7, 2023 Keefe Civil Project Number: 2022-027
Fort Collins Utilities
ATTN: Water Utilities Engineering
281 North College Avenue
Fort Collins, Colorado 80521
RE: 1620 La Eda Drive Certification of Lot Grading
Permit Application # B2209164
Larimer County Parcel # 9610306002
To Whom It May Concern:
The elevations and drainage patterns shown on the attached 1620 La Eda Drive grade exhibit by
Majestic Surveying (surveyed 06/21/23) are in general conformance with the city-approved 1620
La Eda Drive grading plan by Keefe Civil (11/30/22) with the following exceptions.
Item #3 in the attached certification of lot grading was initialed “No” because all as-built elevations
are not within 0.2 ft tolerance of the approved grading plan. The building was constructed slightly
lower than shown on the plans. Despite as-built elevations differing from the approved grading
plans, the elevations and drainage patterns are consistent with the site’s grading plan.
Item #4 in the attached certification of lot grading was initialed “No” because a foundation is not a
part of typical pole barn construction.
Items #5 and 7 in the attached certification of lot grading were initialed “No” because the following
highlighted elevation at the southeast corner is slightly higher than the building corner.
When I visited the site, there appeared to be a slight mound of dirt in this corner. Under my
supervision, the grading was adjusted in this corner to provide a positive slope away from the
building corner.
1620 La Eda Drive Certification of Lot Grading Keefe Civil Project No.: 2022-027
Page 2 of 2 July 7, 2023
Figure 1: Before photos
Figure 2: After photos
Item #8 in the attached certification of lot grading was initialed “No” because gutters were not
installed with the pole barn construction.
In my professional opinion, the elevations and grading at the site are functionally adequate and
equivalent to the specifically approved drainage plan and will affect stormwater drainage on and
off the site in a manner consistent with the approved grading and drainage plan.
Please do not hesitate to reach out to me if you have any questions or comments regarding this
certification of lot grading. (970) 215-6808
Best regards,
Megan L. Keefe, PE / Manager
Keefe Civil, Inc.
Enclosures
Cc: Ron Kapperman, Property Owner
5065
5066
5067
50
6
5
50
6
6
50
6
7
5067
5068
5069
50
6
6
50
6
7
50
6
8
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
SHEET
16
2
0
L
A
E
D
A
L
A
N
E
KE
E
F
E
C
I
V
I
L
,
I
N
C
31
2
5
C
R
O
C
K
E
T
T
S
T
R
E
E
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
6
(9
7
0
)
2
1
5
-
6
8
0
8
ME
G
@
K
E
E
F
E
C
I
V
I
L
.
C
O
M
1 OF 1
GR
A
D
I
N
G
P
L
A
N
PROPOSED 80'X50'
POLE BARN
DS DS
DS
DS