Loading...
HomeMy WebLinkAboutLot Certifications - 04/01/2015 (31)City of Utilities electric• stormwater. wastewater. water Fort Collins 700w°on PO Box 580 Fort Collins,, CO 80522 970.221.6700 970.221.6619 fax . 970.224.6003 TDD . utiGties6fcgov.com . %gov.com/utflitles CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 03/30/15 Permit Application No. B1403006 Address: 403 Osiander Street Lot: 12 Block: 7 Subdivision: Old Town North Subdivision CO CSC'r0'0Ld on Yt/1044;- etitaro.J rL{JrN�p on 4�i�7y(S I,(Print) Wyatt M. Knutson , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 03/30/15 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the properly (information attached). SEE NOTE. ® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwat and off the lot/site in a manner consistent with the approved drainage plan. SEE NO Kel1.Fti, 'Mir, _l� CO NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, Including but not limited to drawings of the toilette showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Infonnatlonlexplanatlon of discrepancies, and other information necessary to confirm the above certification to: Final Grade Assurance Observation: C T L I T H O M P S O N Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observations and opinions at the 0me of our visit. Client: FR Development Site Address: 403 Ostander Street Job#: WY00924.000 Lot: 12 Block: 7 Date: 3/30/2015 Contact: Kevin DeWen Subdivision/filing: Old Town North Backaround Information: Referenced Grading Plan: Shear Engineering Corporation Dated: Jotd: STA# MEASUREMENT ELEVATION REMARKS 1 0.00 65.88 BM/Prop. Corner 2 0.25 66.13 Prop. Comer 3 0.65 66.53 4 1.35 67.23 5 3.40 69.28 Fin. Floor 6 1.36 67.18 7 1.05 66.93 8 1.80 67.68 9 1.55 67.43 High Point 101 0.25 66.13 11 0.10 65.98 12 -0.50 65.38 Prop. Comer 13 490 64.98 Prop. Comer 14 0.20 66.08 15 -0.45 65.43 16 1.25 67.13 17 0.85 66.73 High Point 18 19 20 21 22 Site: �es/ S i 4J cx i,4, Ag7.ee o "- North Summary of opinions: It is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitue. o Rejected (2nd observation required) Corrective action: CTL I Thompson, Inc. 1 1103 Old Town Lane, Cheyenne, WY 82009 I • J9B NU 2 5-01-30-01 06/11/14 SCALE 1'=20' 6RAV10 IRS L9. RADIUS: CHORD: BRG: N6355'11"W \O'AA._ BRG: N62'48'46"W Growvcv�gtineertivc, tic. Strt7cts+ral E inedri" 4 Intyec Nns 524 Stover St. Phone. (970) 490 — 9537 Fort CoUbm, Colorado 80524 Cell: (970) 691 — 4239 reymfSOnsn.eom SITE PLAN LOT AREA - 3,176.22 SF FR DEVELOPMENT LOT 12. BLOCK 7, 403 OSIANDER OLD TOWN NORTH SUB. No Text