Loading...
HomeMy WebLinkAboutLot Certifications - 01/23/2015Utilities Cityof electric• stormwater. wastewater. water Fort Collins 700 W°°n PO Box 580 Fort Collins,, CO 80522 970.221.6700 970.221.6619 tax . 970.224.6003 TDD u1i1xes@a)agov.corim . 1cgov.com/011ities CERTIFICATION OF LOT GRADING Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) Date: 03/30/15 CO a4or0,04 ors '/23/20rs Permit Application No. B1403003 1 Address: 399 Osiander Street Lot: 11 Block: 7 Subdivision: Old Town North Subdivision I,(Print) Wyatt M. Knutson , a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date): 03/30/15 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lottsite as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect storov exv- p -n and off the loUsite in a manner consistent with the approved drainage plan. SEWN By: PE party) CO NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certlflcate of Occupancy for the IoVslte, Including but not limited to drawings of the IoVslte showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Informationtexplanation of discrepancles, and other Information necessary to confirm the above certification to: Final Grade Assurance Observation: C T L I T H O M P S O N Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observations and opinions at the time of our visit. Client: FR Development Site Address: 399 Osiander Street Job#: WY00924.000 Lot: 11 Block: 7 Date: 3/30/2015 Contact: Kevin Dewlen Subdivision/tiling: Old Town North Backaround Information: Referenced Grading Plan: Shear Engineering Corporation Dated: Job* STA# MEASUREMENT ELEVATION REMARKS 1 0.00 65.84 BM/Prop. Comer 2 0.00 65.84 Prop. Comer 3 0.65 66.49 4 1.20 67.04 5 3.30 69.14 Fin. Floor 6 1.75 67.59 7 1.25 67:09 High Point 8 1.00 66.84 9 1.23 67.07 10 -0.20 65.64 11 -0.451 65.39 12 -0.70 65.14 Pro .'Comer 13 -0.90 64.94 Prop. Comer 14 -0.15 65.69 15 -0.45 65.39 16 1.20 67.04 17 0.851 66.69 High Point 18 19 20 21 22 Site: .di ."d LF .(lb North Si!mmary of opinions: It Is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitue. o Rejected (2nd observation required) Corrective action: CTL I Thompson, Inc. 1 1103 Old Town Lane, Cheyenne, WY 92009 JDB ra 25-01-29-01 06/09/14 SCALE 1'=20' DRAWN RS RADIUS: CHORD: aa.ry BRG: N66'10'29`W L9,gy Grown Zn tivi eer I llt. Structura(E ineari+u� ylnspec s 524 Stow St Phone (070) 498 — 9537 Fort CoBBu. Colorado 80524 Cell: (970) 691 — 4239 reyesss50man.eom NUS: 977.50' )RD: 39.71' N66'11'07"W SITE PLAN LOT AREA = 3,207.89 SF FR DEVELOPMENT LOT 11, BLOCK 7, 399 OSIANDER OLD TOWN NORTH SUB. No Text