Loading...
HomeMy WebLinkAboutLot Certifications - 02/20/2015 (43)CityOf Utilities electric. stonnwater. wastewater. water F6700 t Collins PO Box 580 ■ FWoons, Fort Collins, CO 80522 970.221.6700 970.221.6619 619fax . 970.224.6003 TDD ` utilities@fcgov.com , lcgovcom/utilities CERTIFICATION OF LOT GRADING Date: 02/18/15 Permit Application No. Pursuant to City Code § 26-544 and City Land Use Code § 3.2.2 (e) B1402599 Address: 875E Baum Street Lot: M20 Block: 7 Subdivision: Old Town North Subdivision CO rJe&'.*d 'Aahots I,(Print) Wyatt M. Knutson a Colorado registered professional engineer, verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed f m a survey performed on (Date): 02/18/15 , accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one): ❑ The elevations and drainage patterns of the lot/site are insubstantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. ® The elevations and drainage patterns of the lot/site as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect si consistent with the approved drainage plan. SEE By: 1103 Old off the lot/site in a manner Wyoming 82009 NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the lot/site, Including but not limited to drawings of the lot/site showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales, retaining walls, lot comers), written Informationlexplanation of discrepancies, and other Information necessary to confirm the above certification to: Final Grade Assurance Observation: Per the client's request, a representative of CTL has visually observed and measured elevations of the grading aruond the home at the site referenced below. The following summarizes our observafions and opinions at the time of our visit. CTLITHOMPSON Client: Phase V, LLC. Site Address : 875 Baum St., Fort Collins, CO Job#:. WY01035.001 Lot: M18-21 Block: 7 Date: 2/17/2015 Contact: Cleve Schenck Subdivision/filing: Old Town North Background Information: Referenced Grading Plan: Precision Drafting Dated: May 2014 Job#: 1180-01-13 STA# MEASUREMENT ELEVATION REMARKS 1 0.00 63.77 BM/Prop. Corner 2 1.70 65.47 3 1.25 65.02 4 0.20 63.97 Prop. Comer - 5 1.60 65.37 6 1.6 65.37 7 2.20 65.97 Slab 8 1.70 65.47 High Point/Slab 9 1.25 65.02 10 0.40 64.17 Prop. Corner 11 1.45 65.22 Slab 12 0.801 64.57 Prop. Comer 13 2.351 66.12 Finish Floor, 14 1.351 65.12 15 1.351 65.12 16 0.25 64.02 Prop. Comer 17 1.75 65.52 Slab 18 1.00 64.77 Prop. Corner 19 2.30 66.07 Finish Floor 20 1.20 64.97 21 1.251 65.02 22 0.351 64.12 Prop. Comer 23 1.851 65.62 Slab ' 24 1.85 65.62 Slab 25 1.25 65.021 Prop. Comer 26 2.30 66.071 Finish Floor 27 1.30 65.07 on A'Ir Rd 99 1 Prnn Cnrnor North Summary of opinions: X It is our opinion that the top of foundation and grades around the home are consistent with the above referenced grading plan or are a functionally adequate substitue. o Rejected (2nd observation required) Corrective action: Site: my E. ST E�ME 2S- N, N, ., IT *Aq 21 X A�, mi elf.57 M19 M20 PIP Id 2 s lil.117 M22 170 M23 SITE PLAN FOR UNITS 1-4, 675 BAUM STREET LOT M18-M21, BLOCK 7, OLD TOWN NORTH FORT COLLINS, COLORADO PHASE V, UC MAY. 2014