HomeMy WebLinkAboutGrading Plans - 07/05/2024X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X XXX
X
X
X X
8' - 5"
GATE
GATE
FENCE
PARKING
EXISTING
GARAGE
EXISTING
RESIDENCE
PORCH
ALLEY
ELIZABETH STREET
SIDEWALK
PROPOSED
ADDITION
PORTION OF EXISTING RESIDENCE
TO BE DEMOLISHED
WALL OF NEW ADDITION
STEP BACK 12" FROM
EXISTING WALL
12"
DO
W
N
DO
W
N
SIDE
ENTRY
FRONT
ENTRY
REAR ENTRY
EXISTING
TREE
PATIO
5' - 4"
WALL OF NEW ADDITION
STEP BACK FROM
EXISTING WALL
29' - 0"
20
'
-
0
"
W
I
N
D
O
W
W
E
L
L
W
I
N
D
O
W
W
E
L
L
W
I
N
D
O
W
W
E
L
L
PORTION OF EXISTING RESIDENCE
TO BE DEMOLISHED
= 152 sq ft
W
I
N
D
O
W
W
E
L
L
RAISED
GARDEN BED
RAISED
GARDEN BED
DO
W
N
5' - 8"
SE
T
B
A
C
K
15
'
-
0
"
SETBACK
5' - 0"
SETBACK
5' - 0"
60
'
-
8
"
SE
T
B
A
C
K
5'
-
0
"
DN
SE
W
E
R
L
I
N
E
WA
T
E
R
L
I
N
E
EL
E
C
T
R
I
C
L
I
N
E
ELECTRIC
METER
OPTION #2
ADD ALTERNATE:
REPLACE EXISTING
PARKING PAD w/
NEW CONCRETE PAD
GA
S
L
I
N
E
ABANDON
EXISTING
GAS LINE
DS
DS DS
DS
(E) DS
(E) DS
(EXACT SIZE/SHAPE/MATERIAL
TBD BY LANDSCAPE DESIGN)
ELECTRIC
METER
OPTION #1
EXISTING
ELECTRICAL
SERVICE
C O D E D A T A
Address:
Site Area:
Occupancy Classification:
Construction Type:
Number of Stories:2 + BASEMENT
TYPE R-3
V-B
425 EAST ELIZABETH,
FORT COLLINS, CO 80524
7000 SF
2021 I.R.C. w/ LOCAL AMMENDMENTS
2021 I.F.C. w/ LOCAL AMMENDMENTS
2021 I.E.C.C. w/ LOCAL AMMENDMENTS
ROOF MIN R-60
WALLS MIN R-30 CAVITY (OR R-20 CAVITY + R-5 C.I.)
BASEMENT WALLS MIN R-15 CONT. OR MIN. R-19 CAVITY
WINDOW U-FACTOR MAX .28
0.25 MAX. U-VALUE ON ELEVATIONS WITH 30% GLAZING OR MORE
Codes:
Zone District:NCM -NEIGHBORHOOD CONSERVATION,
MEDIUM DENSITY DISTRICT
983 sf
959 sf
+ 575 sf
= 2517 sf
Residence Main Level (to remain)
Residence Upper Level (to remain)
Garage (to remain)
TOTAL EXISTING FLOOR AREA TO REMAIN
2517 sf
+ 580 sf
= 3097 sf
Total Existing Floor Area to Remain
Proposed New Floor Area
TOTAL PROPOSED FLOOR AREA:
Max Allowable Floor Area (overall)
= 7000 sf x .25 + 1000 sf = 2750 sf
-250 sf detached accessory structure
= 2847 sf = 3.5% greater than Max Allowable Floor Area
Max Allowable Floor Area (on the rear half of the lot)
= 3500 sf x .33
= 1155 sf
575 sf
+ 271 sf
= 846 sf
Garage
Proposed New Floor Arear on the rear half
TOTAL FLOOR AREA ON THE REAR HALF:
419 Canyon Ave Suite 200, Fort Collins, Colorado 80521
970.224.1191 | www.VFLA.com
DRAWING NUMBER:
PROJECT NUMBER:
SEAL:
IN ASSOCIATION WITH:
Strength in design. Strength in partnership.
Strength in community.
VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC.
THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR
COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA.
CHECKED BY:
DRAWN BY:
COPYRIGHT:
SHEET ISSUANCES
DESCRIPTION DATE
REVISIONS
No.Description Date
VAUGHT FRYE LARSON ARONSON
TM
TM
NOT FOR CONSTRUCTION
FOR REFERENCE ONLY
A R C H I T E C T U R E + I N T E R I O R S
PEN ENGINEERING, LLC
(720) 347-0054
wthompson@pen-engineeringllc.com
www.pen-engineeringllc.com
CONTACT: WAYNE THOMPSON
7/
5
/
2
0
2
4
1
:
1
4
:
0
2
P
M
7/5/2024 1:14:02 PM
C:
\
U
s
e
r
s
\
t
a
y
l
o
r
\
D
o
c
u
m
e
n
t
s
\
O
c
e
a
n
a
k
R
e
s
i
d
e
n
c
e
_
t
a
y
l
o
r
9
U2
C
7
.
r
v
t
A0.1
SITE PLAN
OCEANAK
RESIDENCE
REMODEL &
ADDITION
425 EAST ELIZABETH
FORT COLLINS, CO
80524
CONSTRUCTION SET 07-05-2024
2023-21
1" = 10'-0"1 ARCHITECTURAL SITE PLAN
2 ABOVE SOUTHWEST 5
3 SOUTHEAST 5
4 SOUTHWEST 5
EAST
ELEVATION
SOUTH
ELEVATION
WEST
ELEVATION
PROJECT
NORTH
CHANGE IN IMPERVIOUS
SURFACE AREA
CHANGE IN IMPERVIOUS SURFACE AREA
PORTION OF EXISTING RESIDENCE TO BE DEMOLISHED-152 sq ft =
580 sq ft =
428 sq ft =
PROPOSED NEW FLOOR AREA
07-05-2024
DS = DOWNSPOUT, TYP.