Loading...
HomeMy WebLinkAboutLot Certifications - 04/07/2014 (8)utilities CI}" Of electric. stormwater. wastewater. water ` �/ 700 Wood Sl. Fort Collins Fo Box 580 Fort Collins. CO 80522 970.221.6700 970,221,6619619 fax . 970.224.6003 TDD utilitiesCo fcgov.com . fogovcornlutildres CERTIFICATION OF LOT GRADING Pursuant to City Code 2§ 6-544 and City Land Use Code 6 3.2.2 (e) Date. April 2014 ict; ,,0 4 Permit Application No 81305086 Address 5657 Kadenwood Drive Lot. 3 Block 5 Subdivision: Kechter Crossing Planned Land Division 1.(Pnnt) Steven M. Strickling . a Colorado registered professional engineer. verify that the above referenced property in the City of Fort Collins, Colorado, has been inspected by me or an appropriately qualified professional under my direct supervision, and verify that construction of all stormwater facilities and grading is complete, and that the elevations and drainage patterns shown on the attached drawing(s) which were developed from a survey performed on (Date). March 31. 2014 . accurately and truly depict the elevations and drainage patterns as they existed on the date of the survey. Based on this information, I certify that (check one). ✓ The elevations and drainage patterns of the IoUsite are in substantial conformance with the City approved drainage and grading plan for the property (information attached). SEE NOTE. The elevations and drainage patterns of the lotlsite as measured are in general conformance with the City approved drainage plan with exceptions (information attached). In my professional judgment the elevations and grading of the lot/site as constructed are functionally adequate and equivalent to the specifically approved drainage plan, and will affect stormwater drainage on and off the lottsite in a manner consistent with the approved drainage plan SEE NOTE. By. 10056 Brisbane Lane. Littleton CO 80130 (address of signing party) NOTE: A COMPLETE certification must be submitted at least two weeks prior to a request for a Certificate of Occupancy for the IoUsite, including but not limited to drawings of the lotisite showing the approved design and as -built surveyed elevations of all structures, drainage and grading features (e.g. swales. retaining walls. lot comers). written inforrnation/explanation of discrepancies. and other information necessary to confirm the above certification to: Fort Collins Utilities 700 Wood Street Fort Collins, CO 80521 (970)221-6700 Rev t 2-1- At least Two Weeks Prior To Requesting A Certification Of Occupancy For The Property mz I LANE �� �� i q •� / W N atimeer •� r.. nrr-wrr--a� ar�� S _ O OD Oo j� WAIL Tw. -- ` A 4946.80 I �; : 4945.80 I . , I ' I-----i� — -�•--DIY �� c- - - �� ,► B5-L3 '-L2 A `' B5AL2 `j h Tf=4945.60 l TF=4945.10 4946.50 l t PAD=4944.3 PAD=4943.E :4945.39 f !� � � •� � � it � ` f I'. _ASA.3=- '--L3 4945 40 — I� 0 w v z Z ELEVATION Surveying d .� 6841 SOUTH YOSEMITE STREET 1100 CENTENNIAL, CO 80112 AND DRAINAGE CERTIFICATE NO.14-KCP-3-5 DNGTSPRPIRAIAEOINLET AUN PROPOSED DRAINAGE BACN OF CURB UNE 0 20 40 KADENWOOD DRIVE 53' R.O.W. LOT 3, BLOCK 5, KECHTER CROSSING PLANNING DIVISION, COUNTY OF LARIMER, STATE OF COLORADO; ALSO KNOWN AS-565T KADENWOOD DRIVE. ELEVATION AND DRAINAGE CERTIFICATE I HEREBY CERTIFY THAT THE GRADING AND DRAINAGE PATTERNS SHOWN HEREON WERE DEVELOPED FROM AN ELEVATION SURVEY OF THE PROPERTY DESCRIBED HEREON, PERFORMED ON THE DATE SHOWN, AND TO THE BEST OF MY KNOWLEDGE AND BELIEF, ACCURATELY DEPICT THE RELATIVE ELEVATIONS AS THEY EXISTED ON THE DATE OF THE SURVEY. THE RELATIVE ELEVATIONS WERE MEASURED TO THE NEAREST 0.1 FEET. THERE IS SUBSTANTIAL POSITIVE SURFACE DRAINAGE AWAY FROM THE FOUNDATION AND THE GRADING AND DRAINAGE PATTERNS SUBSTANTIALLY MEET THE REQUIREMENTS AS SHOWN ON THE PLOT PLAN. DATED 09-19-13 . THE ELEVATIONS DEPICTED HEREON MAY CHANGE SUBSEOUENT TO THE DATE HEREON DUE TO SUBSIDENCE OR UPHEAVAL OF SOILS, ADDITION OR REMOVAL OF SOILS, EROSION OF SOILS BY WIND OR WATER OR OTHER FACTORS. DRAINAGE DRAINAGE SWALES OR FLOW MAY BE BLOCKED BY FENCES, WALKS, LANDSCAPING OR OTHER IMPROVEMENTS, THEREFORE THIS SURVEY MAY NOT ACCURATELY DEPICT THE GRADING AND DRAINAGE PATTERNS SUBSEQUENT TO THE DATE OF THIS SURVEY. THIS DOCUMENT IS NOT AN IMPROVEMENI LOCATION CERTIFICATE OR LAVD SURVEY PUT. THE ABM STALLEMENT DOES NOT WARRANT THIS PROPERTY 10 BE FREE FROM INSTANCES OF STANDING OR SLOW CRANING WATER AWAY FROM THE FOUNWTgN.