Loading...
HomeMy WebLinkAboutGrading Plans - 01/17/2020STRUCTURAL OBSERVATION REPORT Job No. RCPP21-19114 - - " 38390 � � _`. � ; '�, Date signed: January 13, 2'019 l.•`v�=f '�;';�' F.� This is a verified password �' _ :1�' secured signature � � . , � Recycled Properties 1289 Main St., #4131 Windsor, Colorado 80550 .�P��.. ��c�s � ,��-�.k- E>EN�q� T``�c^ _> : .� ��• o .� Grading plan and drainage memo accepted and permit released 1 /17/2020 DJM Re: Site drainage observation at your residence at 727 Stover St, Fort Collins Dear Sir or Madam: On January 9, 2019 I observed the current site conditions at the subject property. Crown Jade Design and Engineering (CJDE) has been retained by Recycled Properties to provide a drainage memo to the City of Fort Collins regarding the subject property; subdivision 10177-FTC, Block 177; Lot description BEG AT PT 50 FT N OF SE COR, TH W 190 FT, N 50 FT, E 190 FT, S 50 FT TPOB; Building Permit Application No. B1915747; Parcel No. 9713119018. Photos from the site visit can be referenced in attachment A and a proposed grading plan, which matches the existing grading with the addition of storm water subdrain intercepts, can be referenced in attachment B. The current structure at the subject property will be completely removed and a new structure will be constructed. The new structure and proposed grading plan have been designed by CJDE. It is our understanding that an approved drainage plan is not on file at the City of Fort Collins as the existing construction permit predates that requirement. The improvements to the storm water drainage will allow storm water to flow off the lot and not impact the adjacent properties to the north, south and west. The new construction will maintain the historic drainage of the lot as closely as possible, ensure existing swales are maintained and add subdrain intercepts to conform to the City of Fort Collin's requirements. As shown in attachment A, the existing conditions of the lot vary in directing storm water to the east via swales along the north and south property lines. There are areas where the adjacent property looks to be flat and no swale is defined. To ensure proper drainage without affecting the adjacent property, perforated PVC pipe intercepts will be added at these locations on the north and south property lines (Attachment B). The Engineered for the way you build ... ... Designed for the way you live. intercepts will discharge into a leach pit on the southeast corner of the lot. If the leach pit fills during heavy rain events, water will flow east onto the adjacent street (Stover St.). A backflow preventor will be installed to ensure backflow does not happen in the event the leach pit fills. These installations will be constructed on the subject property and will not impact the adjacent properties to the north and south. The maximum slope west to east of the lot is lo which does not meet the required 2o by the City of Fort Collins. The historic elevation constraints of this lot limit the available drop of the overall lot. Looking at the limited historical data, this has been the maximum slope for the lot since the original approved building permit. To change the lot elevations would require extensive groundwork and the need to import large amounts of new soil. It is our opinion that, given the historic data of the existing lot, installation of the new subsurface intercept and maintenance of the swales along the north and south property lines, the 10 difference of slope will not cause storm water to impact the adjacent properties and the swales and subdrain intercepts will properly direct storm water to the east without the need to drastically change the existing lot. Please note that the Professional Engineer's seal on this cover letter is valid for all of the pages attached to it; if the items are separated electronically or physically, all of the individual pages are to be considered invalid. Thank you for retaining us to perform this structural evaluation service. Please feel free to contact our office if you have any further questions. Very truly yours, KEITH BOWHAN, EIT, BSCE MARK BENJAMIN, PE, MSCE, SECB, CPHC �Certified in the practice of structural engineering� �Certified Passive House Consultant� Copies: (1) verified password secured document. If submitting to a building department, provide CJDE with an email contact so that we may send it directly per most building department's request. Attachments: Two Attachment A — Resident Photos .—�,�,' "". I� , ... � �!� � _ ♦i, � �f � -� � � r �� � ��- � \ � \ �� ,.� ...� ��A . ' ,A "' ,q F .Y' � �."p`'Y� ' 4 �* ;C�.'` �'iy .: � ��t �, � .. � f ., � x ;. , .: : ;�' � � "�. ' `" ` � n� `i i`Y L - '` ;,� . A `t�` .� � �� � '�S. '�� r,x f r� ,� -...� .., �� �� ,� � � `�, �- � " '+ ° m'� c i+�� � . '%aF h ��,.',r��+sf � n�''�r `� �� k. ``.� A P h � .a .. _ Al ��F _� _ � ., . �..- . Figure 1a (left) & 1b (right) — North property line looking east (left) and west (right) �: � � S — 4� :i :�„'mS ,"�,! F� ' Figures 2a (left) & 2b (right) — South property line looking east (left) and west (right) 190' 9�_z- 9g--1" NORTH 1 JO.O� �RADE g DETAIL PS4 0 PVC — __ — _ ' —" '— �'— —.—� —.—� .. —� --�— — � _ . �. _ '—_— — — — — — _ . (((}�� - . . CAP ENU OF PIPE /' ��TOP (�il6" ELOW � /' � . . . T ----- 9fi A,/. _ /' —� �� Y _______ -- � -------------------------L_-- —.---- --- -----.--- ----..—. ....__....—_ ------ o I�� 2 CAR GARAGE 'i � 727 STOVER SL _. -_ � w lo � � f SUBFLOOR @ 100'-0 ' ia i � �,,, ��,, T.O. CONC. @ t 98'_10„ �_ T.O.W. CONC. `= i T.O. P RIMETER GRADE @ 98'-4" 3,502 sq. ft. W 99�I.. 'N G DER@99'4R N� f o NEW j o �m � ___ , RESIDENCE Q � I 98 8" � / II I ` � � � / CFlP END OF PIPE \ � T.O.P. @ 6" BELOW � / GRAUE I I � � / � . � � I � � � ,. ._.. .. �. - .:'J -65'BEND T.O.P. @ 10" BELOW GRAOF — — — ' — — ' i i i � i :i i i \ i � i � 4" SGH. AO PVC �I SI.OPF@1`/o 6ACK FILL wl I NATNE SOIL I \ I \ � � I I 1 \ 1� ti � I � RENo �--� \ la � S � � I~ � ¢ � IW W � I� O \� I (J� �SEC DCTAIL P55 / I T.O.P.Q�6.' \ I ' BELOW GRA�E �� �L f-----� -----� ----------------------- � ----- '' ---------='-- --------------- —\---------------\--� \ — — — . �v —_ �_--- 1 — � -- _ — 9fl, �.— — — — _ '— _ '— '_ '_ _ '_ _ '_ — _ — — —' .—�" 9I ✓�, — — 9�, � y..— _ '_ — 96' l l Y" — � — —' —' ' — — — — _' — —' ___ / � eXISiING InnPERVI0U5 nREAs: �OUSE o60 SFIEDS- 384 CONCFEfE- 8fi2 I'OiAL- 2196 NeW IMPER`/IOUS AREMS: �OUSF 2e20 GAFA6C 52V CONCR:iF- E53 � 1 10lAL- 3802 NO�c O(' 915CLAIMtR' ALI. OF -HE I�'FORMa�O�i pN iHU SIfE PLAN IS A('f'k(JkIMAIL P.NJ!sAS �+OT BE N VF2IFIE'J RV n 2FGISiERED LANUSJIVE Oh.MARXBE�JAMIN PEISNO 2f5PON5i8LCfOR�FE nccuen„vo. raissir�F�nN —.—.-- q,•l'EH�ORAi[D PVC � 4" SCHE. 64 PVC <" PERFORATFD PVC pF<AI�AGF BASIN SLOPEATt% N GRADING PLAN oE'^aPs° � a°MiNusncc.Mnx. oeTAi� Pss ve• = r � — / � r J / I !Y � � O ,� , . Q . utrr[ �� -- � : � ,; _ SURFACEINTERCEPTOR DRAIN SECTION PS4 .�:, ��«�� ='� � ��� ��,���. f�I . �..,.>ir � � ',J . �.nt n[ra PSS LEACH PIT FOR INTERCEPTOR DRAIN SECTION AO,L GRADING PLAN SCALE: 1 /8" = 1' � crswn jade �Es��N A�o FN�����N� CtiGINEERC� FnR iHE WAY YO'J BUII.D... ,. CESIGNEO FOn il�lE wAY YOU LIVE � w STOVER RESIDENCE NFw 2FSIocNGE Ai: I >^fOVERSi. �OR1..OLLINS. CC IAxIMER COUNi'! OW,�rF: RE��C,F� PROFERnEs 129+� MAIN S�. n4!31 WINCSOR,CO HONt' 0399P3595 scn�e I /A = I- J.N.O. GRADING PLAN FINAL DATE Ol 132020 � 0111312(t20 � ENGINEERS JOB H RCPP21-79114 SHEET A0.2